• 제목/요약/키워드: water temperature sensor

검색결과 292건 처리시간 0.028초

수위, 온도, 전도도 측정을 위한 다기능 One-Chip 센서의 제조 (Fabrication of a multi-functional one-chip sensor for detecting water depth, temperature, and conductivity)

  • 송낙천;조용수;최시영
    • 센서학회지
    • /
    • 제15권1호
    • /
    • pp.7-12
    • /
    • 2006
  • The multi-functional one-chip sensor has been fabricated to reduce output variation under various water environment. There were a temperature sensor, a piezoresistive type pressure sensor, and a electrode type conductivity sensor in the fabricated one-chip sensor. This sensor was measured water depth in the range of $0{\sim}180cm$, temperature in the range of $0{\sim}50^{\circ}C$, and salinity in the range of 0 $0wt%{\sim}5wt%$, respectively. Since the change of water depth in solution environment depends on various factors such as salinity, latitude, temperature, and atmospheric pressure, the water depth sensor is needed to be compensated. We tried to compensate the salinity and temperature dependence for the pressure in water by using lookup-table method.

고온용 플라스틱 필름 수위 센서 개발 (Development of Plastic Film Type Water Level Sensor for High Temperature)

  • 이영태
    • 반도체디스플레이기술학회지
    • /
    • 제18권4호
    • /
    • pp.124-128
    • /
    • 2019
  • In this paper, a high temperature plastic film type water level sensor was developed. The high temperature film type water level sensor was manufactured by attaching a copper film to a polyimide film which can be used for a long time at 250℃, by laminating process and patterning the electrode by etching process. For the performance evaluation of the developed film type water level sensor, the temperature dependence of the capacitance was measured, and the deformation was examined after standing for 8 hours in 150℃ air. The developed film type water level sensor can be used at up to 150℃, and can be applied to electric ports and steam devices.

냉각된 원전 2차계통수의 온도측정을 위한 비접촉식 광섬유 온도센서의 개발 (Development of a Fiber-optic Noncontact Temperature Sensor for Measuring the Temperature of Cooled Secondary Water in a Nuclear Power Plant)

  • 유욱재;이봉수;박병기;조영호
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1730-1734
    • /
    • 2010
  • 원전 2차계통수의 pH를 예측을 위해서는 샘플을 채취, 냉각시킨 후 pH를 측정하게 되는데 이 때 샘플의 온도는 pH를 변화시키는 중요한 요인이 된다. 본 연구에서는 할로겐화 은 광섬유를 이용하여 비접촉식 온도센서를 개발하였고, 열전쌍열을 이용하여 열원으로부터 방출되는 적외선을 측정하였다. 열원과 광섬유 끝단 사이의 거리 및 각도 변화에 따른 광섬유 온도센서의 출력신호를 분석하였으며, 광섬유 온도센서로 측정한 온도범위는 $25{\sim}60^{\circ}C$이다. 본 연구결과를 기초로 원전 2차계통수 pH 샘플의 온도를 측정하기 위해 할로겐화 은 광섬유를 이용한 비접촉식 온도센서의 개발이 가능할 것으로 기대된다.

다중온도센서를 통한 입체적인 호소 온도모니터링 평가 (Spatial Reservoir Temperature Monitoring using Thermal Line Sensor)

  • 황기섭;박동순;정우성
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1002-1006
    • /
    • 2006
  • Temperature monitoring techniques per depth have been recognized as important information in the reservoir environmental issues. However, old measurement method by single temperature sensor and cable type has demerits not only for its limited measuring location but for its inconvenience of users. In this study, multi-channel temperature monitoring system was introduced and executed experiment for actual application feasibility evaluation. Both type of new techniques such as multi-channel addressable built-in temperature sensor and fiber optic multi sensor were tested in Daechung and Imha reservoir. As a result, it was proved that these kinds of temperature monitoring skills had very good performance and availability for a output of spatial, simultaneous thermal distribution focused on the user's convenience. And these measuring method and thermal data will be useful for providing basic information in a water resources investigation like reservoir stratification and environmental problems.

  • PDF

다중 온도 모니터링을 통한 충적층 및 하상의 지열특성 평가 연구 (A Study on Geothermal Evaluation of Alluvium and Riverbed using Thermal Line Temperature Monitoring)

  • 정우성;김형수;박동순;안영섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.171-178
    • /
    • 2006
  • In advanced countries, state-of-the-art temperature monitoring technique is widely used for effective use of geothermal resources. But these kind of modern tools such as Thermal Line Sensor has not been applied to find geothermal characteristics of alluvium and riverbed in domestic area. In this research, state-of-the-art thermal line temperature sensor monitoring was introduced. And long term field test using this type of sensor was performed to find geothermal characteristics of alluvium and riverbed and evaluate the availability for heat energy source. As a result, temperature monitoring technique through thermal line sensor was very effective to obtain basic geothermal information of alluvium deposit and riverbed. Also, it was found that the groundwater temperature phase showed its potential of utilization as a energy source of heat pump. It is estimated that further study shows a specific corelation between temperature monitoring data and its availability as a energy source.

  • PDF

거대자기저항 스핀밸브 소자를 이용한 의료용 냉각기 수위 및 수온 센서의 제작과 특성 (Fabrication and Property of Water Level and Temperature Sensor for Medical Cooling System Using a Highly Sensitive GMR-SV Device)

  • 박광준;최종구;이상석;이범주
    • 한국자기학회지
    • /
    • 제21권1호
    • /
    • pp.32-36
    • /
    • 2011
  • DC 마그네트론 스퍼터링을 이용하여 제작한 고감도 거대자기저항 스핀밸브 박막 소자를 이용하여 수위 및 수온을 측정할 수 있는 센서를 제작하였다. 제작한 센서의 수위 및 수온 분해능은 각각 $400\;m{\Omega}/mm$$100\;m{\Omega}/^{\circ}C$ 이었으며, 이는 전립선 비대증 KTP(potassium titanyl phosphate) 레이저 치료기에서 냉각기의 수위 및 수온을 조절하는 센서로써 응용이 가능하다.

보일러용 정전용량형 수위센서 시스템 개발 (Development of Capacitive Water Level Sensor System for Boiler)

  • 이영태;권익현
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.103-107
    • /
    • 2021
  • In this paper, a capacitive water level sensor for boilers was developed. In order to accurately monitor the water level in a high-temperature boiler that generates a lot of precipitates, the occurrence of precipitates on the surface of the water level sensor should be small, and a sensor capable of measuring even if the sensor surface is somewhat contaminated is required. The capacitive water level sensor has a structure in which one of the two electrodes is insulated with Teflon coating, and the stainless steel package of the water level sensor is brought into contact with the water tank so that the entire water tank becomes another electrode of the water level sensor. A C-V converter that converts the capacitance change of the capacitive water level sensor into a voltage change was developed and integrated with the water level sensor to minimize noise. The performance of the developed capacitive water level sensor was evaluated through measurement.

개방회로 상태 PEMFC 내부 온도와 습도 측정을 통한 수분투과 분석 (Analysis of Water Transport through Measurement of Temperature and Relative Humidity in PEMFC at OCV)

  • 김태형;한재수;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.353-362
    • /
    • 2022
  • In this study, water diffusion in proton exchange membrane fuel cell at open circuit voltage (OCV) was analyzed through experiment. First, the reliability of the micro-sensor (SHT31) was verified. It was concluded the micro-sensor has an excellent reliability at 60℃ and 70℃. After the sensor reliability test, the temperature and relative humidity measurement in bipolar-plate was conducted at OCV. To analyze water distribution and water flux, the temperature and relative humidity was converted into dew point. To the end, it was found water concentration affects water diffusion.

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • 제3권4호
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

도금 공장의 화재 예방을 위한 도금장비 개선에 관한 연구 (A Study on improvement of plating equipment for fire prevention)

  • 김성재;김성곤;유우식
    • 대한안전경영과학회지
    • /
    • 제19권4호
    • /
    • pp.35-42
    • /
    • 2017
  • A number of plating companies have been exposed to the risk of fire due to unexpected temperature increasing of water or other reasons in a plating bath. Since the companies are not able to forecast the unexpected temperature increasing of plating bath and most of raw materials in the bath have low ignition temperature, it is easy to be exposed to the risk of fire. Thus, in previous study, we tried to monitor and notice the dangerous change of temperature of water immediately to prevent the risk of fire from plating process. However, unfortunately previous studies were not able to shut out the fundamental cause of fire since bath temperature sensor can detect air temperature when the level sensor was malfunctioned. In this paper we developed the Teflon heater which contains a built in temperature sensor and improved plating equipment system. Teflon heater is improved using Pt $100{\Omega}$ sensor which can detect until $600^{\circ}C$. When the bath temperature sensor detects over $60^{\circ}C$ or the Teflon heater sensor detects over $240^{\circ}C$ they temporarily shut down the heater to control temperature. Also relay completely shuts down main power when detects instant temperature is detected over 5% of $240^{\circ}C$ by the heater sensor to prevent teflon melting down and fire spreads. Developed plating equipment system can monitor a real time temperature in the teflon tube and bath water. Therefore we think the proposed plating equipment can eliminate the possibility of fire in plating processes fundamentally.