• Title/Summary/Keyword: water primer

Search Result 163, Processing Time 0.029 seconds

A Study on the Toothbrush-Dentifrice Abrasion of Class V Restroations (치경부 5급 와동 수복의 잇솔질 마모에 관한 연구)

  • Hwang, Su-Jin;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.69-81
    • /
    • 2005
  • The objective of this study was to evaluate the toothbrush abrasion characteristics of class V restorations. Thirty extracted human premolars, which were collected from oral surgery clinics were used. We mounted five teeth in a metal ring mold of 50 mm in diameter and 15 mm in height using chemically cured acrylic resin. Class V cavities were prepared in lingual cervical root surfaces and restored using one of following restorative materials : Dentin Conditioner/Fuji II LC (Group FL), All Bond II/Z-250 (Group ZT), One-up Bond F/Palfigue Estelite (Group PE), F2000 Primer/Adhesive (Group FT), and Prime & Bond 2.1/Dyract AP (Group DR). They were stored under distilled water at $37^{\circ}C$ for seven days. The toothbrush abrasion test was conducted using a wear testing machine of pin-on disk type under a load of 1.5 N for 100,000 cycles. We have examined the bonded interfaces, the changes of surface roughness and color of abraded surfaces. From this experiment, the following results were obtained. 1. The change of surface roughness showed high degree: RMGIC>compomer>composite resin (p<0.05). 2. Because of the protrusion and missing of filler particles, SEM observation of abraded surfaces of RMGIC and compomers revealed the increase of surface roughness due to the selective removal of matrix resin. 3. The color change by toothbrush abrasion was affected in large part by the change of $L^*$ and $b^*$ of resin composites (p<0.05). 4. The color change by toothbrush abrasion was so small to detect by human eyes. 5. SEM observation of abraded surfaces revealed the interface bonding was the best in the FT group.

Several factors affecting on seed germination of Dracocephalum argunense Fischer ex Link

  • Chang, Young-Deug;Lee, Cheol-Hee;Song, Jeong-Seob;Hwang, Ju-Kwang
    • Korean Journal of Plant Resources
    • /
    • v.22 no.3
    • /
    • pp.236-241
    • /
    • 2009
  • Dracocephalum argunense Fischer ex Link (Labiatae) is a perennial herbaceous plant used as valuable materials for ornamentals, honey production, and pharmaceutics. Since seed germination of this species was quite difficult, present studies were conducted to improve the germination rate by subjecting the seeds to various environmental conditions (temperature and light) and treatments (scarification, priming and seed coating). Optimum temperature for adequate germination was 20$^{\circ}C$ though it ranged from 15$^{\circ}C$ to 25$^{\circ}C$, and low temperature treatment improved germination rate. Light was required for higher germination rate in this species. The scarification of seeds resulted in much higher germination, especially by the physical treatment with sandpaper or chemical treatment with sulfuric acid for 30 seconds. Various primers with different concentrations were treated on the seeds and it was demonstrated that low temperature enhanced germination rate, regardless of kinds and concentrations of the primers. Three treatment combinations of the primers, 0.5 mM $GA_{3}$ treated for 48 hours, 0.5 mM IAA for 24 hours, and 1.0 mM IAA for 24 hours, increased the seed germination rate profoundly. Soaking treatment of inorganic salts, $KNO_{3}$ and $KH_{3}PO_{4}$, promoted germination when seeds were subjected to low temperature. Water soluble primers such as sucrose at 0.5 and 3% concentration and solid primer talc powder were effective in enhancing germination rate.

tufA gene as molecular marker for freshwater Chlorophyceae

  • Vieira, Helena Henriques;Bagatini, Inessa Lacativa;Guinart, Carla Marques;Vieira, Armando Augusto Henriques
    • ALGAE
    • /
    • v.31 no.2
    • /
    • pp.155-165
    • /
    • 2016
  • Green microalgae from the class Chlorophyceae represent a major biodiversity component of eukaryotic algae in continental water. Identification and classification of this group through morphology is a hard task, since it may present cryptic species and phenotypic plasticity. Despite the increasing use of molecular methods for identification of microorganisms, no single standard barcode marker is yet established for this important group of green microalgae. Some available studies present results with a limited number of chlorophycean genera or using markers that require many different primers for different groups within the class. Thus, we aimed to find a single marker easily amplified and with wide coverage within Chlorophyceae using only one pair of primers. Here, we tested the universality of primers for different genes (tufA, ITS, rbcL, and UCP4) in 22 strains, comprising 18 different species from different orders of Chlorophyceae. The ITS primers sequenced only 3 strains and the UCP primer failed to amplify any strain. We tested two pairs of primers for rbcL and the best pair provided sequences for 10 strains whereas the second one provided sequences for only 7 strains. The pair of primers for the tufA gene presented good results for Chlorophyceae, successfully sequencing 21 strains and recovering the expected phylogeny relationships within the class. Thus, the tufA marker stands out as a good choice to be used as molecular marker for the class.

Direct and indirect bonding of wire retainers to bovine enamel using three resin systems: shear bond strength comparisons (부착 유지장치의 직, 간접 부착법에 따른 전단 접착력 비교)

  • Kwon, Tae-Yub;Meina, Hu;Antoszewska, Joana;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.447-453
    • /
    • 2011
  • Objective: We compared the shear bond strength (SBS) of lingual retainers bonded to bovine enamel with three different resins using direct and indirect methods. Methods: Both ends of pre-fabricated twisted ligature wires were bonded to bovine enamel surfaces using Light-Core, Tetric N-Flow, or Transbond XT. Phosphoric acid-etched enamel surfaces were primed with One-Step prior to bonding with Light-Core or Tetric N-Flow. Transbond XT primer was used prior to bonding with Transbond XT. After 24 hours in water at $37^{\circ}C$, we performed SBS tests on the samples. We also assigned adhesive remnant index (ARI) scores after debonding and predicted the clinical performance of materials and bonding techniques from Weibull analyses. Results: Direct bonding produced significantly higher SBS values than indirect bonding for all materials. The SBS for Light-Core was significantly higher than that for Tetric N-Flow, and there was no significant difference between the direct bonding SBS of Transbond XT and that of Light-Core. Weibull analysis indicated Light-Core performed better than other indirectly bonded resins. Conclusions: When the SBS of a wire retainer is of primary concern, direct bonding methods are superior to indirect bonding methods. Light-Core may perform better than Transbond XT or Tetric N-Flow when bonded indirectly.

THE EFFECT OF DIFFERENT SURFACE TREATMENTS ON THE SHEAR BOND STRENGTH OF THE RESIN TO TYPE IV GOLD ALLOY (금속면의 표면처리 방법에 따른 금합금과 전장레진간의 전단결합강도에 관한 연구)

  • Park, Dong-Won;Lim, Ho-Nam;Woo, Yi-Hyung;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.685-692
    • /
    • 1995
  • The effect of five different surface treatments on the shear bond strength of the resin bond to Type IV Gold alloy was studied by bonding resin to metal. The metal surface was subjected to one of the following treatments and bonded ;(1) air abraded with $50{\mu}m$ alumina particles,(2) beads(3) beads and tin-plated at curreant density of 300mA/$cm^2$,(4) tin-plated at current density of 300mA/$cm^2$,(5) silicacoating with sililink, and bonded with an MDP Opaque primer, CESEAD resin system. The bonded specimens were immersed in water for 23 hours after 1 hour resin curing and shear bond strength were recorded. On the basis of this study, the following conclusions can be drawn; 1. Difference were found in the shear bond strength among all experimental groups. And bead glroup exihibited the highest shear bond strength and sand blasting group exhibited the lowest shear bond strength on five groups. 2. Bead group, mechanical bonding was significantly higher than that obtained with the samples, tinplating, silicacoating, and chemical bonding. 3. No statistically signiflcant difference was found between the shear bond strengths obtained with bead and bead-tinplating, and between tinplating and sili cacoating.

  • PDF

Pathogenicity and Occurrence of Pepper Seedling Anthracnose Caused by Colletotrichum acutatum (고추 유묘에 대한 Colletotrichum acutatum의 병원성과 탄저병 발생)

  • Han, Kyung-Sook;Park, Jong-Han;Han, You-Kyoung;Hwang, Jung-Hwan
    • Research in Plant Disease
    • /
    • v.15 no.2
    • /
    • pp.88-93
    • /
    • 2009
  • In 2008, leaf rot and blight on pepper seeding ("Dokya-chungchung") occurred in a pepper farm at Hwaseong-si, Gyeonggi-do, Korea. The typical symptom is water-soaking and dark brown leaf blight at edges and tips of leaves. The fungal colonies isolated from infected tissues were pinkish at first and turned gradually to gray. Conidia were fusiform, non-septum, and $8.1-17.0{\times}2.0-3.8{\mu}m$ in size. Several specific PCR primers derived from the sequence of the internal transcribed spacer (ITS) region of the rDNA, such as CaINT, CgINT and CcINT were used for the identification of the fungal pathogen. The C. acutatum-specific primer CaINT was amplified single fragment of 496 bp that discriminated C. acutatum from the other species. The pathogenicity test was performed on seedlings and fruits of red pepper. On the basis of the morphological, molecular characteristics and pathogenicity test, we identified as Colletotrichum acutatum. This is the first report on leaf rot and blight on pepper seedling caused by C. acutatum in Korea.

A Study on the Joint Property by the Surface Treatment Method on the Jointing Method of PET Film using the High Hardness Liquid (고경질 도막을 이용한 PET 필름 접합공법의 필름 표면처리 방법에 따른 접합특성 연구)

  • Lee, Jong-Suk;Kim, Young-Sam;Shin, Hong-Chol;Kim, Young-Geun;Kang, Chung-Mo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.153-159
    • /
    • 2014
  • This research reviewed the joint and duration characteristics depending on the surface treatment condition and lap spliced length in the PET film jointing method using the high hardness liquid material. As a result, the corona discharge treatment was improved to the contact angle, joint tensile strength, and joint peel resistance compared to non-treatment. Particularly, a surface treatment E (Corona discharge + Primer + PU bond + Polyester fabric) turned out to the best, and especially when the lap spliced length is longer than 15mm, stable joint performance was secured under the long term deterioration treatment of 16 weeks. Thus, the joint is considered to be applicable as the water-proof material.

Using Reverse Dot Hybridization Method and 16S rRNA Gene (16S rDNA) for Identifying the Food Poisoning Microorganism in Foods (Reverse dot hybridization 방법과 16S rRNA gene(16S rDNA)을 이용한 식품에서 식중독균의 탐색)

  • Kim, Min-Seong;Shin, Kyu-Chul;Lee, Hyung-Gu;Han, Myung-Soo;Min, Byung-Re;Choi, Yong-Keel
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.470-474
    • /
    • 2003
  • DNA sequence information on small-subunit rRNA gene (16S rDNA) obtained from food-poisoning bacterial culture was used to investigate the presence of bacterial pathogens in food. By reverse dot blot detection method, presence of food-poisoning bacteria could be confirmed on hybridization of digoxigenin-labeled 16S rDNA Polymerase Chain Reaction (PCR) primer product and biotin-labeled specific oligonucleotide probe. Escherichia coli, Bacillus cereus. and Salmonella sp. were used as the representative food-poisoning bacterial microorganisms. An oligonucleotide probe, based on the variable region of 16S rRNA gene, was used as the specific probe. These tools may be more useful than classic biochemical method for rapid identification of contaminated food.

A COMPARATIVE STUDY OF SHEAR BOND STRENGTH OF FLOWABLE RESIN ASSOCIATED WITH DENTIN ADHESIVE SYSTEMS WITH THERMOCYCLING EFFECT (상아질접착제와 열순환에 따른 유동성 레진의 전단결합강도 비교 연구)

  • Nam Ki-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.383-393
    • /
    • 2006
  • Statement of problem : Limited research on flowable resin has been undertaken on its application directly on dentin associated with the adhesive systems. Purpose : This study was to evaluate the shear bond strengh and fracture aspect of flowable resin on human dentin with various types of dentin bonding adhesives with thermo cycling effect. Materials and methods: Filtek-Flow(3M ESPE, USA) was used as flowable resin and Eighty human molars were randomly divided into 4 groups : three dentin bonding adhesives (Scotchbond-Multipurpose : 3-step contentional system, One-Step : One-bottle system. Prompt L-Pop : All-in-one, self-etching primer) and 32% etching treatment without bonding adhesive as a control group. For evaluating their durability of bonding, each group was subdivided : storaging in the water at 37$^{\circ}C$(24 hours) and thermocycling (0$^{\circ}C$-55$^{\circ}C$, 30 seconds intervals, 1000 cycle). Shear bond strength tests were performed and resin-dentin interface and fracture mode were observed. Results were analysed by one-way ANOVA and Scheffe's multiple range test. Results and Conclusion : 1. At 0 cycle, the mean shear bond strength of One-Step exhibited the highest value of all groups(p<0.05), and there were no significant differences between Prompt L-Pop and Scotchbond-Multipurpose, Scotchbond-Multipurpose and control(p>0.05). After 1000 thermocycling, One-Step exhibited higher value than other groups(p<0.05), and there were no significant differences among other groups (p>0.05). 2. The shear bond strength of each group was significantly decreased after thermocycling except Scotchbond-Multipurpose (p>0.05). 3. The most common failure mode was adhesive type and mixed type, next in order.

Influence of modeling agents on the surface properties of an esthetic nano-hybrid composite

  • Kutuk, Zeynep Bilge;Erden, Ecem;Aksahin, Damla Lara;Durak, Zeynep Elif;Dulda, Alp Can
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.13.1-13.10
    • /
    • 2020
  • Objective: The aim of this study was to evaluate the influence of different modeling agents on the surface microhardness (Vickers hardness number; VHN), roughness (Ra), and color change (ΔE) of a nano-hybrid composite with or without exposure to discoloration by coffee. Materials and Methods: Sixty-four cylinder-shaped nano-hybrid composite specimens were prepared using a Teflon mold. The specimens' surfaces were prepared according to the following groups: group 1, no modeling agent; group 2, Modeling Liquid; group 3, a universal adhesive (G-Premio Bond); and group 4, the first step of a 2-step self-adhesive system (OptiBond XTR). Specimens were randomly allocated into 2 groups (n = 8) according to the storage medium (distilled water or coffee). VHN, Ra, and ΔE were measured at 24 hours, 1 week, and 6 weeks. The Kruskal-Wallis test followed by the Bonferroni correction for pairwise comparisons was used for statistical analysis (α = 0.05). Results: Storage time did not influence the VHN of the nano-hybrid composite in any group (p > 0.05). OptiBond XTR Primer application affected the VHN negatively in all investigated storage medium and time conditions (p < 0.05). Modeling Liquid application yielded improved Ra values for the specimens stored in coffee at each time point (p < 0.05). Modeling Liquid application was associated with the lowest ΔE values in all investigated storage medium and time conditions (p < 0.05). Conclusion: Different types of modeling agents could affect the surface properties and discoloration of nano-hybrid composites.