• Title/Summary/Keyword: water pipe

Search Result 1,710, Processing Time 0.03 seconds

Struvite Crystallization of Swine Wastewater using Bittern (간수를 이용한 축산폐수의 struvite 결정화)

  • Ryu, Hong-Duck;Kim, Tae-Su;Park, Hyoung-Soon;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.138-143
    • /
    • 2007
  • This study goes in for the observation of the characteristics of nitrogen removal from swine wastewater by struvite crystallization. In addition, the struvite formation potential in supernatants after struvite crystallization was investigated. In the study for nitrogen removal by struvite crystallization, the effects of pH and molar ratio of magnesium (Mg) injected using bittern as Mg source were investigated. Also, the potential of struvite formation in the supernatant with amount of Mg added was carefully observed. As the results, the optimum pH in the removal of nitrogen was 8.8 and sludge volume was increased as pH was raised from 7 to 12 under the condition that the molar ratio of $Mg^{2+}$ to ${NH_4}^+$-N to ${PO_4}^{3-}$-P was 1:1:1. An optimum removal efficiency of ammonia-N was observed at 1 molar ratio of Mg to ${NH_4}^+$-N, showing no further increase at over 1 molar ratio and dramatical deterioration at under 1 molar ratio. However, the sludge volume was increased by increasing the molar ratio of Mg. In the experiments for the potential of struvite formation in the supernatants, initial -log([$Mg^{2+}$][${NH_4}^+$][${PO_4}^{3-}$]) value was much lower than $pK_{sp}$ and gradually reached $pK_{sp}$ at 2 days, as the molar ratio of Mg increased over 1.2. At 31 days, -log([$Mg^{2+}$][${NH_4}^+$][${PO_4}^{3-}$]) value was returned to the initial value. In addition, the supernatants had a potential precipitation of hydroxylapatite due to calcium contained in bittern, $K_2Mg(SO_4)_3$ and $K_3Na(SO_4)_2$ resulting from the decrease of sodium and potassium in supernatants formed after struvite crystallization as times go by. Based on the results, it appears that some retention time and proper dosage of Mg may be needed for the prevention of scale in pipe line.

Development and Applications of Multi-layered Harmony Search Algorithm for Improving Optimization Efficiency (최적화 기법 효율성 개선을 위한 Multi-layered Harmony Search Algorithm의 개발 및 적용)

  • Lee, Ho Min;Yoo, Do Guen;Lee, Eui Hoon;Choi, Young Hwan;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.1-12
    • /
    • 2016
  • The Harmony Search Algorithm (HSA) is one of the recently developed metaheuristic optimization algorithms. Since the development of HSA, it has been applied by many researchers from various fields. The increasing complexity of problems has created enormous challenges for the current technique, and improved techniques of optimization algorithms are required. In this study, to improve the HSA in terms of a structural setting, a new HSA that has structural characteristics, called the Multi-layered Harmony Search Algorithm (MLHSA) was proposed. In this new method, the structural characteristics were added to HSA to improve the exploration and exploitation capability. In addition, the MLHSA was applied to optimization problems, including unconstrained benchmark functions and water distribution system pipe diameter design problems to verify the efficiency and applicability of the proposed algorithm. The results revealed the strength of MLHSA and its competitiveness.

Biodegradability of Artificial Bait for Blue Crab Pots and Its Effect on Seawater Quality (꽃게 통발용 인공미끼의 생분해도 및 해양수질 영향)

  • Jeong, Byung-Gon;Koo, Jae-Geun;Chang, Ho-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.2
    • /
    • pp.96-103
    • /
    • 2009
  • The biodegradability in water of the artificial baits for blue crab pots which were made of intestines of mackerel, tuna and grinded krill were studied. The biodegradability of artificial bait was evaluated with the effective capacity of 10L water tank which was made of acryl pipe at the velocity of 1m/d and hydraulic retention time of 12 hours. For the 23 days operation time, all artificial baits were degraded fast at the early stage of operation time and stabilized within 5 days after start up. The rates of biodegradation were different depending on the raw materials of artificial baits. In terms of degradation rate of organic matter which can be expressed as COD, artificial bait made of tunas intestine showed the fastest degradation rate. On the other hand, in terms of degradation rate of nitrogenous matter which can be expressed as ammonia nitrogen, artificial bait made of mackerels intestine showed the fastest degradation rate. In order to evaluate the effect of artificial bait on marine ecosystem, seawater qualities including SS, COD, DO, nitrogen, phosphorus were determined depending on depth and location during 2 days test operation period. It is apparent that the effect of artificial bait on seawater quality was negligible when comparing seawater quality of test operation area with control area.

  • PDF

Characteristics of Spray Deposit Pattern and Flow Rate in the Air-Center Nozzle System (Air-center nozzle의 분무살포도(噴霧撒布度)와 분무량(噴霧量)의 특성(特性))

  • Lee, Sang Woo;Hur, Yun Kun
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.156-168
    • /
    • 1980
  • The air-center nozzles, being specially designed to supply air into the central part of water stream at seven levels of air volume, were tested for spray deposit pattern and flow-rate at each of the twelve pressure levels ranging from $0.35kg/cm^2$ (5 psi) to $6.33kg/cm^2$ (90 psi) in comparison with those of standard nozzles. The air-center nozzles produced comparatively more stable spray deposit patterns than the standard nozzles. The spray deposit patterns of the air-center nozzle were concentrated gradually in the central region with increase of air volume as a component of spray mixture. The degree of concentration of spray deposit on the central region from the air-center nozzle was higher than that of the standard nozzle, which suggested the possibility of obtaining farther travel distance spraying system at a given performance level. The flow rate of the air-center nozzle was not as much as that of the standard nozzle due to the air within certain limits. The rate of decrease of water flow became smaller with an increase in operating pressure although it changed rapidly in the beginning stage, ranging up to two or three percent of the air flow rate due to the compressive properties of air.

  • PDF

A Study on the Application of Hydraulic Calculations considering the Corrosion Coefficient of Steel Piping for Fire Protection (소방용 강관배관 부식계수를 고려한 수리계산 적용방안에 관한 연구)

  • Mun, Chul-Hwan;Kang, Ho-Jung;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.69-77
    • /
    • 2020
  • With the recent enlargement and complication of buildings, damage caused by the incidents of fires breaking out are escalating. Consequently, the use of sprinkler facilities is increasing among water-based fire extinguishing systems. Piping materials used in fire prevention systems include carbon steel (for general or pressure pipeline), CPVC, copper, and stainless-steel. Among these, the steel and CPVC pipes, which are commonly employed in fire prevention, were considered for testing the reliability of the water-based systems. This analysis was performed using the PIPENET software to perform hydraulic calculations in order to examine the flow and pressure at the terminal head when the corrosion coefficient was applied; this coefficient was applied considering the aging of pipes. Assuming a uniform pipe diameter in the steel pipes, the rated flow in the pump installed on the first floor of the basement was reduced by over 10% after 20 years had passed (C value of 90); moreover, the reduction in pressure and flow at its terminal head exceeded 30% and 16.5%, respectively. The results indicate that it is difficult to ensure the reliability of these fire prevention facilities. Furthermore, according to our estimation, considering 30 years had passed (C value of 80), the rated flow of the pump was reduced by over 15%, and the corresponding reduction in pressure and flow at its terminal head exceeded 42% and 24%, respectively.

Development of head loss coefficient formula at surcharged four-way combining square manhole with variation of inlet flow (유입유량 변화를 고려한 과부하 4방향 사각형 합류맨홀에서의 손실계수 산정식 개발)

  • Jo, Jun Beom;Kim, Jung Soo;Yoon, Sei Eui
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.12
    • /
    • pp.877-887
    • /
    • 2017
  • The energy losses due to surcharged flow at four-way combining manhole, which is mainly installed in the downstream of urban sewer system, is the main cause of inundation in urban area. Surcharged four-way combining manholes form various flow configuration such as straight through, T-type, and four-way manholes depending on variation of inflow discharge in inlet pipes. Therefore, it is necessary to analyze change of energy loss and estimate head loss coefficients at surcharged four-way combining manhole with variation of inflow discharge ratio. The hydraulic experimental apparatus which can change inflow ratios were installed to analyze the flow characteristics at four-way combining manhole. In this study, to calculate the head loss coefficient according to change of the inflow discharge ratios at the surcharged four-way combining square manhole, the discharge conditions of 40 cases which the inflow ratios of each inlet pipe were changed by 10% interval was selected. The head loss coefficient at surcharged square manhole showed the lowest value of 0.40 at the straight manhole and the highest value of 1.58 at the $90^{\circ}$ junction manhole. In the combining manholes (T-type and four-way), the head loss coefficients were calculated more higher as the lateral flow rate was biased. The contour map of head loss coefficient range was constructed by using the estimated head loss coefficients and the empirical formula of head loss coefficients was derived to consider the variation of inflow discharge ratios at the surcharged square manhole. The empirical formula could be applied to the design and assessment of the urban drainage system.

Application of the Poisson Cluster Rainfall Generation Model to the Urban Flood Analysis (포아송 클러스터 강우 생성 모형을 이용한 도시 홍수 해석)

  • Park, Hyunjin;Yang, Jungsuk;Han, Jaemoon;Kim, Dongkyun
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.9
    • /
    • pp.729-741
    • /
    • 2015
  • This study examined the applicability of MBLRP (Modified Bartlett-Lewis Rectangular Pulse) rainfall generation model for an urban flood simulation which is a type of Poisson cluster rainfall generation model. This study constructed XP-SWMM model for Namgajwa area of Hongjecheon basin, which is a two-dimensional pipe network-surface flood simulation program and computed a flood discharge and a flooded area with input data of synthetic rainfall time series of 200 years that were generated by the MBLRP model. This study compared the data of flood with synthetic rainfall and flood with corresponding values which were based on design rainfall. The results showed that the flooded area computed with MBLRP model was somewhat smaller than the corresponding values on the basis of the design. A degree of underestimation was from 8% (5 year) to 34% (200 year) and the degree of underestimation increased as a return period increased. This study is meaningful in that it proposes methodology that enables quantifiability of uncertain variables which are related to a flooding through Monte Carlo analysis of urban flooding simulation and applicability and limitations thereof.

Evaluation of High-Resolution QPE data for Urban Runoff Analysis (고해상도 QPE 자료의 도시유출해석 적용성 평가)

  • Choi, Sumin;Yoon, Seongsim;Lee, Byongju;Choi, Youngjean
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.9
    • /
    • pp.719-728
    • /
    • 2015
  • In this study, urban runoff analyses were performed using high resolution Quantitative Precipitation Estimation (QPE), and variation of rainfall and runoff were analyzed to evaluate QPE data for urban runoff analysis. The five drainage districts (Seocho3, 4, 5, Yeoksam and Nonhyun) around Gangnam station were chosen as study area, the area is $7.4km^2$. Rainfall data from KMA AWS (34 stations), SKP AWS (156 stations) and Gwanduk radar were used for QPEs in Seoul area. Four types of QPE(QPE1: KMA AWS, QPE2: KMA+ SKP AWS, QPE3: Gwangduk radar, QPE4: QPE2+QPE3) of 6 events in July 2013 were generated by using Krigging and conditional merging. The temporal and spatial resolution of QPEs are 10 minutes and 250 m, respectively. The complex pipe network were treated as 773 manholes, 772 sub-drainage districts and 1,059 pipelines for urban runoff analysis as input data. QPE2 and QPE4 show spatial variation of rainfall by sub-drainage districts as 1.9 times bigger than QPE1. The peak runoff of QPE2 and QPE4 also show spatial variation as 6 times bigger than Gangnam and Seocho AWS. Thus, the spatial variation of rainfall and runoff could exist in small area such as this study area, and using high-resolution rainfall data is desirable for accurate urban runoff analysis.

Development of Novel Joint Device for a Disposal Canister in Deep Borehole Disposal (고준위폐기물 심부시추공 처분을 위한 처분용기 접속장치의 개발)

  • LEE, Minsoo;LEE, Jongyoul;JI, Sung-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.261-270
    • /
    • 2018
  • In this study, to replace the 'J-slot joint', a joint device between a disposal canister and an emplacement jig in Deep Borehole Disposal process, a novel joint device was designed and tested. The novel joint device was composed of a wedge on top of a disposal canister and a hook box at the end of a winch system. The designed joint device had merits in that it can recombine an emplaced canister freely without the replacement of the joint component. Moreover, it can be applied to various emplacement jigs such as drill pipes, wire-lines, and coiled tubing. To demonstrate the designed joint device, the joint device (${\Phi}110mm$, H 148 mm), a twin canister string (${\Phi}140mm$, H 1,105 mm), and a water tube (${\Phi}150mm$, H 1,500 mm) as a borehole model were manufactured at 1/3 scale. As deployment muds, Na-type bentonite (MX-80) and Ca-type (GJ II) bentonite muds were prepared at solid contents of 7wt% and 28wt%, respectively. The manufactured joint device showed good performance in pure water and viscous muds, with an operation speed of $10m{\cdot}min^{-1}$. It was concluded that the newly developed joint device can be used for the emplacement and retrieval of a deep disposal canister, below 3~5 km, in the future.

Composting Effectiveness of A Sundry System with A Bin-type Composter for Recyle of Animal Wastes (축분뇨처리를 위한 Bin형 부숙조- Sundry 시스템의 퇴비화효율 평가)

  • 최홍림;김현태;정영윤
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.2
    • /
    • pp.92-103
    • /
    • 1993
  • A sunday system with a horizontal bin-type composter was constructed and operated to evaluate its composting performance for four days for each test in October, 1992. A sundry system is one of popular systems for composting livestock manure, of which main benefit is to utilize unlimited, clean, and free solar radiation. A rectangular concrete bin(composter) with dimension of 300cm(length) X90cm(width) X60cm(height) was bedded alternatively with four lanes of aeration pipes and heating pipes, and was insulated at three walls with 50mm styrofoam. Each aeration pipe of a diameter of 25mm had 4mm perforated holes at every 15cm longitudinally, and supplied air of about 2m$^3$/min to the composter to maintain aerobic condition . A stirrer rotating at 1 rpm made one round trip every 20 minutes on the conveying chain along the the length of the composter. Five tests (Test 1~Test 5) were implemented to evaluate the composting effectiveness of a sundry system with a horizontal bin-type composter. Treatments of two levels of the mixture ratio of swine manure and paper sludge cakes(manure : paper sludge cakes= 1 : 4 and 1 : 2) and two levels of the water content(W/C ; 70% and 50%) were made to test the significance of the physicochemical properties for decomposition of the mixture materials. Temperature, C/N ratio, water content, microbial activity of the composting materials were taken measurements to evaluate its performance with the lapse of composting time for tests. A small-scale sundry system with a bin-type composter did not appear to be an appropriate system for composting livestock manure. Since heat generation by the composting materials could not overcome heat loss due to areation in a small-scale composter, a proper thermal enviroment could not be maintained to propagate massively thermopilic microorganism relatively in a short period of time. Different from the result of Chol et al.(1992) 6), a temperature variation of the composting materials did not show the peak clearly and C/N ratio didn't lower with time as expected. Mesophilic microoragnism seemed to play an important role for decomposition of the mixture materials. A sundry system with a bin-type composter may be good for a large-scale livestock farm household which may produce enough animal manure. Therefore a decision should be made very carefully to choose a system for composting livestock waste.

  • PDF