• Title/Summary/Keyword: water meter

Search Result 642, Processing Time 0.026 seconds

A Study on Performance Characteristics of Wetted-type Multi Path Ultrasonic Flowmeter (습식 다회선 초음파유량계의 특성평가 연구)

  • Lee, Dong-Keun;Cho, Yong;Ko, Jae-Myoung;Park, Tae-Jin;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.4
    • /
    • pp.5-9
    • /
    • 2013
  • An experimental investigation has been carried out in order to evaluate characteristics of wetted-type multi-path ultrasonic flowmeters. The multi-path ultrasonic flowmeters were installed at various entrance and exit locations for several cases of pipe fitting(straight, $90^{\circ}$ double elbow) and valve(gate valve, butterfly valve). We measured the flow-rate at each location. The measurement data of test flowmeter were compared with the measured data of reference flowmeter. The uncertainties of reference flowmeter and test flowmeter are 0.3 %, 0.4 %, respectively. The results demonstrate the effects of flowmeter location as well as the measurement errors in flow rate. The distance between the flow disturbance factor and a flowmeter was an important element of the test.

Development of a device to improve the precision of water surface identification for MeV electron beam dosimetry

  • F. Okky Agassy;Jong In Park;In Jung Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1431-1440
    • /
    • 2024
  • The study aimed to develop a laser-based distance meter (LDM) to improve water surface identification for clinical MeV electron beam dosimetry, as inaccurate water surface determination can lead to imprecise positioning of ionization chambers (ICs). The LDM consisted of a laser ranging sensor, a signal processing microcontroller, and a tablet PC for data acquisition. I50 (the water depth at which ionization current drops to 50 % of its maximum) measurements of electron beams were performed using six different types of ICs and compared to other water surface identification methods. The LDM demonstrated reproducible I50 measurements with a level of 0.01 cm for all six ICs. The uncertainty of water depth was evaluated at 0.008 cm with the LDM. The LDM also exposed discrepancies between I50 measurements using different ICs, which was partially reduced by applying an optimum shift of IC's point of measurement (POM) or effective point of measurement (EPOM). However, residual discrepancies due to the energy dependency of the cylindrical chamber's EPOM caused remained. The LDM offers straightforward and efficient means for precision water surface identification, minimizing reliance on individual operator skills.

A Study on the Effect of Irrigation Water Temperature to the Growth and Harvest of Paddy Rice in Various Water Sources (수원별 관개용수의 수온이 수함생육과 수량에 미치는 영향에 관한 연구)

  • 조형용
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.2
    • /
    • pp.2634-2648
    • /
    • 1972
  • The aim of this Study is to bring Light on the effect of irrigation water temperature to the growth and harvest of Paddy rice in Various water Sources. 1. This research was completed in the writer's home nursery garden Located in Chungyoung-Ri, Hoeng sung-Myun, Hoengusung-Konn, Kangwan-Do. 2. The variety of Paddy rice was the IR667. 3. Practice was done by the treatment I .e river water, reservoir, tube well cold and tuke well warm with 3 riplications each. 4. The Paddy was transplanted in a pot 0.9 meter height and 1 meter Square without hottom filled with paddy soil to a planting depth 0.5 meter. The pot was laid underground and Covered with a film of polyethylene to keep of the rain. 5. The method of Cultivation was that used by the Filed Crops Experiment Station of the Office of Rural Development. 6. Atmospheric temperature was recorded every day of the growing period. The precipitation and Sun light was quoted by the KF-46 of Hoengsung. 7. The Soils in the test plots was relatively fortile, being Similar to ordinary paddy soils. 8. The charactor of irrigation water of surface and underground was both normal. 9. During the period of growth the average temperature of the underground water as $14.2^{\circ}C$ and that of the Surface was $24.1^{\circ}$. 10. The most useful water for the rice growing was that of river and reservoir while underground water was found to be generally injurious to the paddy growth because of low temperature. 11. In the case of underground water, there proved to be such harmful effects as reduction of culm length, rate of mature grain, panicle Length and grain weight and delay of tillering time, and heading time. Reading Therefore the writer conduded that the harvest of rice irrigated with underground water Showed a reduction of 15.8% compered with the rice irrigated by surface water.

  • PDF

Submarine Discharge of Fresh Groundwater Through the Coastal Area of Korea Peninsula: Importance as a Future Water Resource (한반도 주변 연안 해저를 통한 담지하수의 유출: 미래 수자원으로서의 중요성)

  • Hwang, Dong-Woon;Kim, Gue-Buem;Lee, Jae-Young
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.15 no.4
    • /
    • pp.192-202
    • /
    • 2010
  • Submarine groundwater discharge (SGD) has been recognized as a provider for freshwater, nutrients, and dissolved constituents from continents to the oceans and paid more attention with regard to the mass balance of water or dissolved constituents on local and global scales. The submarine discharge of fresh groundwater (fresh SGD) through seepage or springs in coastal ocean may be especially important in aspects of water resource and marine environment managements in the future. Based on the worldwide compilations of observed fresh SGD, our review reveals that fresh SGD occurs in various marine environments along most shoreline of the world and the global estimates of fresh SGD were approximately 0.01-17% of surface runoff. In addition, the input of fresh SGD calculated and investigated in this study were about 50%, 57%, 89%, and 420% of total river discharge in Jeju Island, Yeongil Bay, Masan Bay, and Yeoja Bay, respectively. These inputs from fresh SGD along the shoreline of Korea Peninsula are much higher than those of the whole world, greatly vary with the region. However, since these estimates are based on the water balance method mainly used in coastal ocean, we have to perform continuous monitoring of various parameters, such as precipitation, tide, evapotanspiration and water residence time, which have an impact on the water balance in a lot of areas for evaluating the precise input of fresh SGD. In addition, since the method estimating the input of fresh SGD has brought up many problems, it is required to make an intercomparison between various methods such as hydrogeological assumption, numerical modeling, and seepage meter.

Comparison of Soil Moisture Changes Based on the Installation Position of Soil Moisture Sensors in the Korean Orchard Field Soils (노지 과수원에서 토양수분센서 설치 위치에 따른 토양수분 변화 비교)

  • Jong Kyun Kim;Hyunseok Kim;Kyeong-Jin Kang;Jongyun Kim
    • Journal of Bio-Environment Control
    • /
    • v.33 no.2
    • /
    • pp.107-113
    • /
    • 2024
  • For efficient soil water management in open fields, the proper use of soil moisture sensors is a prerequisite. Particularly in open-field environments like orchards with extensive root systems, the appropriate positioning of sensors is very important. The present study was conducted to identify the optimal placement of soil moisture sensors by assessing changes in soil water potential across various positions within orchard field soils after installing tensiometers. In apple and Asian pear orchards located in two regions of Korea, nine soil water potential sensors (TEROS 21, METER Group) were installed at distances of 20, 40, and 60 cm from the tree trunk and depths of 10, 20, and 30 cm from the soil surface, and monitored the soil water potential changes over two years. Results indicated that the positions closer to the tree trunk and the soil surface exhibited more pronounced changes in soil water potential. The greatest magnitude of change in soil water potential was observed at a distance of 20 cm and a depth of 10 cm, suggesting this position as the most suitable for soil moisture sensor installation. However, variations in the degree and pattern of changes in soil water potential were noted across sensor positions due to root system growth over time. Therefore, periodic observation and adjustments in sensor placement would be advisable to accurately monitor the soil moisture condition in long-term crops such as fruit trees in open fields.

An Application of the SRTM Dataset in Inland Water Stage Measurement

  • Bhang, Kon Joon;Lee, Jin-Duk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.06a
    • /
    • pp.83-84
    • /
    • 2014
  • For hydrologic applications, lake levels is very important. As a first step in developing a remote-sensing based approach, lake stage estimation using remote sensing was proposed with the SRTM data from February 2000, which was providing a one-time snapshot. After several steps using contouring, masking, and CED, it was found that iterative contour fitting to a lake outline provided the outstanding result with the operator's decision. If the lake size is large enough, a constant meter of the difference removal due to bias found by Bhang et al. (2007) might be useful for more accurate estimations for the methods. A lake-level snapshot using SRTM data could provide estimates within 0.5 m level of accuracy for large lakes (> $10km^2$) with contouring. Also, even if the processing algorithm is complex, the accuracy was reliable. Overall, we confirmed that this study would provide useful information to ameliorate the quality of the SAR-derived DEMs specifically for water areas and if more expanded, SAR images can fruit result in water monitoring.

  • PDF

Flood control analysis of the sea dike at estuary. (하구방조제의 홍수조절 해석)

  • 서승덕
    • Water for future
    • /
    • v.10 no.2
    • /
    • pp.113-124
    • /
    • 1977
  • Alone the southwesten coast of Korean peninsula, the extensive available arable acreages suited for forming are found in the development of tidal flats in the geographically curved bays with a motable tidal emplitude. It was found that the developments of these tidal flats cover an estimated area more than 276,000ha. In this paper, a flood control system by Pul's Storage Indication Method and Pul's Graphical Method at Return Periods-50 yrs, design rainfall-267mm per 48hrs and design flood-926c.m.s. and at 0.2meter control height above the High Water Ordinary Spring Tide Level (+11.0m) was studied. At the result, the flood demage in the reservoir at Return Periods-50 yrs and the tidal level at H.W.O.S.T.L. were satisfied to the below E.L. 11.20m (Flood Level in the reservoir). Well skilled flood control technique and management and control of draining sluice gate should be required for the disaster prevention from the flood and tide damage.

  • PDF

Bubble Wake Measurement by Acoustic Bubble Spectrometer Generated by Planing Hull at Circulating Water Channel (회류수조에서의 ABS에 의한 활주선 후류 기포항적계측)

  • Shin, Myung-Soo;Moon, Il-Sung;Nah, Young-In;Park, Jong-Chun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • This paper presents bubble wake measurement results generated by the planing hull. The bubble was generated by SNAME TMB model(No. 4876) with hard chine at the CWC(Circulating Water Channel). ABS(Acoustic Bubble Spectrometer) was used to measure bubble wake measurement. The manufactured model is one meter in length and uniform velocity to generate the bubble at CWC is 3m/s, relatively higher speed than conventional hull form. Measurements were performed successfully and measured results show well the general characteristics of bubble wake generated by planing hull. Furthermore, experimental equations are proposed for the practical use.

Preparation of water-swollen-hydrogel membrane for gas separation. I. (기체 분리용 수팽윤성 분리막 제조. I.)

  • 박유인;이규호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.43-44
    • /
    • 1996
  • Water-swollen-hydrogel membranes for gas separation were prepared by dipcoating and thermal crosslinking of poly(vinylalcohol) (PVA) - poly(acrylacid) (PAA) blends on asymmetric porous polyetherimide(PEI) supporters. The polyetherimide supporters, prepared by phase inversion of polyetherimide solutions in N-methylpyrrolidone(NMP) (composition of PEI/NMP=25/75), had good heat and chemical resistane. The coating materials with different blending ratios of PVA/PAA(=90/10, 80/20, 70/30) were characterized with differential scanning calorimetry (DSC), infrared spectroscopy(IR) and the water swelling ratios. The permeabilities and the separation factors of carbon dioxide through these membranes were measured by a mass flow meter and gas chromatograph at different temperatures, respectively, under a vacuum mode of downstream.

  • PDF

Development of a measurement device of water level at the bottom of fuel tanks using an optical cable sensor

  • Kim, Hiesik;Lee, Byoungsuk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.95.1-95
    • /
    • 2002
  • <1. New level meter inside the fuel tank> Ultrasound level sensors are widely applied as level meters of liquid tank. Measurement instrument of level between water and fuel is developed. Since the fuel is inflammable, the sensor system doesn't allow to include any electric circuit inside the fuel tank. The optical cable sensor can satisfy this explosive condition. The measurement method with ultrasonic sensor is attached on the tank wall or tank manhole lid. The pressure sensor can't be applied inside the gasoline fuel tank. An ultra-sonic sensor doesn't detect a enough signal reflected from water level deep under gasoline fuel. The pressure sensor is difficult to measure the height o...

  • PDF