• Title/Summary/Keyword: water leachate

Search Result 321, Processing Time 0.029 seconds

A Study on the Extent of the Pollution of an Illegal Landfill (불량폐기물 매립지의 오염에 관한 고찰)

  • 김동우;박성원;이재영;이평구
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.31-38
    • /
    • 2001
  • An illegal landfill In Korea was evaluated in a view of environmental quality to figure out reusing the area. The sampling spots were selected at a point in the landfill and three points in it's around area(two points in a paddy soils and one in a farm field). The eleven pollutants regulated in the Korean Soil Environmental Preservation Act (KSEPA) were analysed from the soil sample with the method of the KSEPA. As the results of the analysis the level of concentration with most samples indicated the requirement of the KSEPA. The concentration of soil samples met the standard: however, some pollutants in the ground water and leachate showed higher concentration than that of the requirement. Therefore, we must consider the treatments of the pollutants in the ground water and leachate when designing this landfill area for reusing.

  • PDF

Pulsed Power System for Leachate Treatment Application (침출수 처리 응용 펄스전원 시스템)

  • Jang, S.R.;Ahn, S.H.;Ryoo, H.J.;Rim, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.246-247
    • /
    • 2010
  • This paper deals with the water treatment of the leachate from sewage filled ground by a pulsed power technology. Leachate from sewage filled ground should be treated below regulation level of COD in order to prevent environmental pollution and usually treated by a chemical method. Among the pollutants mixed in the leachate, chemical compounds of benzene series are known to be difficult to break down, and need to use high cost treat methods. The treatment of the benzene compounds by high power pulsed power supply was studied. For the high-rate, cost-effective treatment of leachate, pulsed power supply should have high repetition rates and require switching devices of long lifetime. In order to meet the demands of the above condition, pulsed power generator based on semiconductor switches using IGBTs as primary switches were developed. The experimental results verified that benzene compounds can be treated effectively by high voltage electric pulses, and this fact indicates that the treatment method by pulsed power source is a promising substitute.

  • PDF

The Characteristics of water Quality on MSW Landfill Leachate with variation of the Oxidation-Reduction Potential (산화·환원 전위 변화에 따른 도시폐기물 매립지 침출수의 수질 변화 특성)

  • Huh, Mock
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.1
    • /
    • pp.127-133
    • /
    • 2001
  • It can be known that from leachate generated in the initial stage of landfill there are a lot of undecomposed orgainc materials, its sulfur component reduces to sulfide ion by sulfur reducing microorgarnisms as an anaerobic digestion proceeds, the sulfide ion makes the leachate discolor to black by forming metal sulfide sol, on condition that much more equivalent of sulfide ion than that of metal ion is present, and the metal sulfide sol can be generated to the precipitates by forming black-colored particulates. Therefore, we can confirm the important possibility for the economic and efficient treatment of leachate that it can be passivated, provided that much more equivalent of sulfide ion is present in the reaction of sulfide ion and metal ion.

  • PDF

A feasibility study of a pilot scale two-phase anaerobic digestion with ultra filtration for the treatment of garbage leachate (음식물 탈리액 처리를 위한 파일럿 규모의 막결합형 2상 혐기성 소화 공정 가능성 평가)

  • Lee, Eun-young;Heo, Ahn-hee;Kim, Hyung-kuk;Kim, Hee-jun;Bae, Jae-ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.539-545
    • /
    • 2009
  • A feasibility of a pilot scale two-phase anaerobic digestion with ultra filtration system treating garbage leachate were evaluated. The treatment system consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. The average COD removal efficiency of the treatment system was 95% up to the OLR of 3.1 g COD/L/d. The higher COD removal efficiency with membrane unit resulted from the removal of some portion of soluble organics by membrane as well as particulate materials. When the membrane unit was in operation, bulk liquid in acidogenic and methanogenic reactors was partially interchanged, which maintained the acidogenic reactor pH over 5.0 without external chemical addition. Also, with the production of methane in the acidogenic reactor, the organic loading rate of the methanogenic reactor reduced. The initial flux of the membrane unit was $50{\sim}60L/m^2/hr$, but decreased to $5 L/m^2/hr$ after 95 days of operation due to clogging caused by particulate materials such as fibrous materials in garbage leachate. To prevent clogging caused by particulate materials, a pretreatment system such as screening is required. With the improvement with membrane unit operation, the two-phase anaerobic digestion with ultra filtration system is expected to have the possibility of treating garbage leachate.

Fluorescence Properties of Size Fractions of Dissolved Organic Matter Originated From Different Sources (생성 기원에 따른 용존 자연유기물질 분자량별 형광특성 비교)

  • Hur, Jin;Park, Min-Hye
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.482-489
    • /
    • 2007
  • Fluorescence properties and carbohydrate content were investigated using ultrafiltrated size fractions of dissolved organic matters (DOM) originated from different sources. The materials included a treated sewage, an algal organic matter, and a soil leachate, all of which are major constituents of dissolved organic matter in a typical urban river. Four different size fractions were separated from the three sources of each DOM. The size distribution demonstrated that a higher molecular weight fraction was more present in soil leachate compared to two other source DOMs. A higher content of carbohydrates was observed in the following order - algal DOM > treated sewage > soil leachate. A wide range of specific UV absorbance was observed from size fractions of a single source DOM, indicating that aromatic carbon structures are heterogeneously distributed within one source of DOM. The structural heterogeneity was the most pronounced for the soil leachate. The fluorescence index ($F_{450}/F_{500}$) of the treated sewage was similar to that (2.0) typically obtained from autochthonous DOM, suggesting that the treated sewage exhibited autochthonous organic matter-like properties. No protein-like fluorescence intensities were observed for all of the soil leachate size fractions whereas they were observed with two other source DOMs. Based upon the fluorescence peak ratios from fluorescence excitation-emission matrix (EEM), two discrimination indices could be suggested to distinguish three different source DOMs. It is expected that the suggested discrimination indices will be useful to predict the sources of DOM in a typical urban river affected by treated sewage.

Application of Electrical Resistivity Survey For Contaminant Evaluation at Uncontrolled Landfills

  • Lee Seong-Soon;Yoon Hee-Sung;Lee Kang-Kun;Lee Jin-Young;Kim Chang-Gyun;Yu Young-Chul
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.432-435
    • /
    • 2006
  • To evaluate geology and extent of leachate migration around the landfills, electrical resistivity survey were conducted in area of uncontrolled landfills in Cheonan and Wonju. The Cheonan landfill is located above the paddy fields and the resistivity survey lines were crossed to confirm possible pollution of the paddy fields by leakage of the landfill leachate. In Wonju, the landfill and the downgradient paddy fields are divided by a concrete barrier wall. At the bottom of the landfill, there is a leachate settlement system but has not been in operation. And a total of 4 survey line installed (1 parallel and 3 perpendicular to mean groundwater flow direction). According to the resistivity survey results, the landfill leachate in Cheonan appeared to be restricted only within the interior of the landfill, not to migrate into the subsurface of the paddy fields. These results are well consistent with electrical conductivity values of groundwaters obtained from a periodic analysis of water qualities. In Wonju, however, it was inferred that the leachate emanating from the landfill migrated beneath the abandoned leachate settlement system and it would reach the downgradient paddy field.

  • PDF

Bioaugmentation Treatment of Mature Landfill Leachate by New Isolated Ammonia Nitrogen and Humic Acid Resistant Microorganism

  • Yu, Dahai;Yang, Jiyu;Teng, Fei;Feng, Lili;Fang, Xuexun;Ren, Hejun
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.7
    • /
    • pp.987-997
    • /
    • 2014
  • The mature landfill leachate, which is characterized by a high concentration of ammonia nitrogen ($NH_3$-N) and humic acid (HA), poses a challenge to biotreatment methods, due to the constituent toxicity and low biodegradable fraction of the organics. In this study, we applied bioaugmentation technology in landfill leachate degradation by introducing a domesticated $NH_3$-N and HA resistant bacteria strain, which was identified as Bacillus cereus (abbreviated as B. cereus Jlu) and Enterococcus casseliflavus (abbreviated as E. casseliflavus Jlu), respectively. The isolated strains exhibited excellent tolerant ability for $NH_3$-N and HA and they could also greatly improved the COD (chemical oxygen demand), $NH_3$-N and HA removal rate, and efficiency of bioaugmentation degradation of landfill leachate. Only 3 days was required for the domesticated bacteria to remove about 70.0% COD, compared with 9 days' degradation for the undomesticated (autochthonous) bacteria to obtain a similar removal rate. An orthogonal array was then used to further improve the COD and $NH_3$-N removal rate. Under the optimum condition, the COD removal rate in leachate by using E. casseliflavus Jlu and B. cereus Jlu increased to 86.0% and 90.0%, respectively after, 2 days of degradation. The simultaneous removal of $NH_3$-N and HA with more than 50% and 40% removal rate in leachate by employing the sole screened strain was first observed.

Organic Matter Analysis and Physicochemical Properties of Leachate from a Foot-and-Mouth Disease Landfill Site (구제역 가축 매몰지 침출수의 물리 화학적특성과 유기물질 성상분석)

  • Kang, Mee-A;Kim, Mi-Sun;Choi, Byung-Woo;Sohn, Ho-Yong
    • Microbiology and Biotechnology Letters
    • /
    • v.40 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • Foot and mouth disease (FMD) is one of the most notorious and contagious viral diseases afflicting cloven-hoofed animals. In this study, the physicochemical properties of leachate from a FMD landfill site at 773-1, Waryong, Andong, Korea and the ground water from 777, Waryong, Andong, Korea, were analyzed for 1 year from December $10^{th}$ 2010 to November $17^{th}$ 2011. The leachate was collected from the FMD landfill site during March, May, July, September and November, 2011 and changes in pH, brix, water content, insoluble solids, crude proteins, crude lipids, total and reducing sugars and ash content were determined. Considering the annual profiles of temperature and rainfall at the FMD landfill site, the dramatic changes in the physicochemical properties of the leachate from March to July, and especially from May to July, such as increases in pH, and a rapid reduction of brix and organic matter, may be closely linked to the growth of microorganisms in the leachate. The sharp decreases in the concentration of biominerals, such as Mg, Ca, and Fe from 1073, 4311 and 56.2 ppm in March to 151, 78, and 0.1 ppm in November, further suggest that decreases in organic matter in the leachate result from degradation by microorganisms originating from the intestines of the livestock. Analysis of the profiles of the organic materials in the leachate revealed that the properties of the leachate were similar to those of excremental matter-derived water. These results could be applied to a number of fields for the analysis of organic matter behavior, the development of the degradation process, and risk analysis in the environment for hygiene and food industries, of leachate from FMD landfill sites.

Pulsed-Power System for Leachate Treatment Applications

  • Jang, Sung-Roc;Ryoo, Hong-Je;Ok, Seung-Bok
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.612-619
    • /
    • 2011
  • This paper presents a water treatment system for leachate from sewage-filled ground that uses a pulsed-power modulator developed based on semiconductor switches in order to realize a long life, a high repetition rate, and a fast rising time. The specifications of the developed pulsed-power modulator are the pulsed output voltage, the output current, the pulse repetition rate (PRR), the pulse width, and an average output power of $60\;kV_{max}$, $300\;A_{max}$, 3000, $50\;{\mu}s$, and 15 kW, respectively. The pulsed-power water treatment system was introduced and analyzed using an equivalent electrical circuit model to optimize the output voltage waveform. The experimental results verify that the proposed water treatment system can be effectively used for industrial applications.

Ecotoxicity Assessment of Leachate from Disposal Site for Foot-and-Mouth Disease Carcasses (구제역 가축 매몰지 침출수 독성영향평가)

  • Kim, Dongwoo;Yu, Seungho;Chang, Soonwoong;Lee, Junga
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.8
    • /
    • pp.5-11
    • /
    • 2014
  • In this study, chemical analysis and ecotoxicity tests of leachate from disposal site for foot-and-mouth disease carcasses (FMD leachate) were conducted to collect fundamental data that will be used to develop environmental risk assessment tools for FMD leachate. For chemical analysis, concentration of $Cl^-$, $NH{_4}{^+}-N$, Korea standard method indicators for detection of leachate released from animal carcasses burial site into groundwater and NRN (Ninhydrin-Reactive Nitrogens), a newly suggested screening test indicator to detect groundwater contamination by FMD leachate, were assessed. For ecotoxicity tests, luminescent bacteria (V. fischeri), micro-algae (P. subcapitata) and water flea (D. magna) were selected as test species. Correlation analysis between the concentration of $Cl^-$, $NH{_4}{^+}-N$, NRN and the toxicity to V. fischeri was performed to identify the better indicators to monitor FMD leachate contamination. From regression analysis, the concentration of the indicators in FMD leachate contaminated sample that induced halfmaximal toxic effect to V. fischeri was evaluated. Results obtained from this study can be applied to assess the risk by FMD leachate and to establish the guideline to manage risk in relation to FMD leachate.