• 제목/요약/키워드: water hammer

Search Result 165, Processing Time 0.024 seconds

Improved Suter Transform for Pump-Turbine Characteristics

  • Dorfler, Peter K.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.332-341
    • /
    • 2010
  • Standard dimensionless parameters cannot simultaneously represent all operation modes of a pump-turbine. They either have singularities at E=0 and multiple values in the 'unstable' areas, or else get singular at n=0. P. Suter (1966) introduced an alternative set of variables which avoids singularity and always remains unique-valued. This works for non-regulated pumps but not so well for regulated machines. A modification by C.S. Martin avoids distortion at low load. The present paper describes further improvements for the representation of torque, and for closed gate (where Suter's concept does not work). The possibility to interpolate across all operation modes is likewise useful for representing other mechanical parameters of the machine. Practical application for guide vane torque and pressure pulsation data is demonstrated by examples.

Propellants helium saturated efforts and its effects for HTV(H-II transfer vehicle) propulsion system ground firing tests

  • Nakai, Shunichiro;Ishizaki, Shinichiro;Yamamoto, Mio;Okudera, Hiroyuki;Imada, Takane;Matsuo, Shinobu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.399-402
    • /
    • 2008
  • It is well known that helium saturated propellants significantly effects the dynamics of propulsion system, thruster cross coupling, water hammer and thruster performance. Especially for the propulsion systems, which have multiple high thrust engines, such as HTV(H-II transfer vehicle), the effect is more important. Therefore full-saturated propellants should be used at ground tests of HTV propulsion system and evaluate its effects. HTV is an advanced space vehicle being developed by Japan Aerospace Exploration Agency(JAXA) to enhance cargo delivery capabilities of the fleet of vehicles visiting the International Space Station(ISS). This paper presents an overview of the successful effort of the testing with saturated propellants(MMH/MON3) for HTV propulsion system during the ground firing tests.

  • PDF

A Study on Combustion Characteristics of Pulverized Fuel Made from Food Waste (음식물쓰레기로 부터 제조한 분체연료 연소특성)

  • Son, Hyun-Suk;Park, Yung-Sung;Kim, Sang-Guk
    • New & Renewable Energy
    • /
    • v.4 no.4
    • /
    • pp.37-43
    • /
    • 2008
  • Three properties of food waste are water 80%, ash 3%, volatile matter 17%. When food waste goes through treatment process such as removal of foreign substances, removal of water as well as sodium, dryness, and pulverization, it transforms into 4,000 Kcal/kg purverized fuel if moisture content is below 13%. Fuel ratio (fixed carbon/volatile matter) of purverized fuel is low compared with bituminuous coal. Ignition temperature measured by thermogravimetry analyzer is about $460^{\circ}C$. Combustion test of purverized fuel have been performed using energy recovery facility which include storage tank of dewatered cake, dryer, hammer mill, combuster including burner, boiler, flue gas treatment equipment. When 160-180 kg/hr of fuel is steadily supplied to burner for 3 hours, combustor temperature reaches about $1000^{\circ}C$ and CO is 77-103 ppm at 1.55 excess air ratio and SOx and Cl are under 2 ppm and 1ppm, respectively. This experiment demonstrate that purverized fuel made from food waste could be an alternative clean energy at the age of high oil price.

  • PDF

A Study on Combustion Characteristics of Purverized Fuel Made from Food Waste (음식물쓰레기로부터 제조한 분체연료 연소특성)

  • Son, Hyun-Suk;Park, Yung-Sung;Yun, Jong-Deuk;Lee, Ho-Nam;Lee, Seung-Hoon;Kim, Sang-Guk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.149-152
    • /
    • 2008
  • Three properties of food waste are water 80%, ash 3%, volatile matter 17%. When food waste goes through treatment process such as removal of foreign substances, removal of water as well as sodium, dryness, and pulverization, it transforms into 4,000Kcal/kg purverized fuel if moisture content is below 13%. Fuel ratio(fixed carbon/volatile matter) of purverized fuel is low compared with bituminuous coal. Ignition temperature measured by thermogravimetry analyzer is about $460^{\circ}C$. Combustion test of purverized fuel have been performed using energy recovery facility which include storage tank of dewatered cake, dryer, hammer mill, combuster including burner, boiler, flue gas treatment equipment. When 160-180 kg/hr of fuel is steadily supplied to burner for 3 hours, combueter temperature reaches about $1000^{\circ}C$ and CO is 77-103ppm at 1.55 excess air ratio and SOx and Cl are under 2ppm and 1ppm, respectively. This experiment demonstrate that purverized fuel made from food waste could be an alternative clean energy for high oil price era

  • PDF

Dynamic Characteristic of Coastal Reclaimed Land through Shaking Table Test (실내 진동대 실험을 통한 해안매립지반의 동적 특성 평가)

  • Shin, Eun-Chul;Kang, Hyoun-Hoi;Park, Jeong-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.640-648
    • /
    • 2009
  • Recently the truction of coastal reclaimation work has been extensively implemented in Korea. The Sondo New City is being established on the reclaimed land from the sea, construction companies of metro construction are planing to pull-out the sheet pile for saving the construction cost. In the case of soft marine clay, it is very difficult to pull-out the sheet pile by using the hydraulic hammer difficult. Therefore, the man of the field must be aware of vibration effect to the ground and the structure. For understanding the vibration effect to the ground during subway construction, the model was formulated with 1/25 braced-cut for subway construction. Scott and Iai(1989) proposed the law of the similarity for other experimental conditions. The laboratory model test was conducted under the vibration condition of sheet pile pulling out. The settlement on the ground surface was measured during the shaking table test. The pore water pressure was also monitored in the upper, middle, and lower layers of soil. The field settlement level and the pore water pressure can be predicted by using the results of the laboratory shaking table test.

  • PDF

A Residents' Mechanical Equipment Remodeling Preferences Study on the Aged Apartment Housing by Questioning Survey (설문조사를 통한 노후 공동주택의 설비 리모델링 의식조사)

  • Kim, Ji-Hyun;Yoo, Seon-Yong;Lee, Sang-Youp;Jeong, Cha-Su;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1061-1068
    • /
    • 2006
  • This study has been conducted to provide the basic datum to draw mechanical equipments needed for aged apartment housing remodeling by questioning survey and interview for residents who has been lived in the aged apartment housing. To preferences survey, we prepare four forms of sheets - questioning survey and interview for residents, interview for managers, and visiting interview for residents. The questioning survey results shows that some residents feel discomfort for water hammer and water supply noise and for noise and stink transmission from air duct installed ceiling to ventilate bathroom. The interview results for residents and managers shows typically two major problems. The first is insulation and heating problems when balcony extended in each household. The second is piping and shaft layouts problem for maintenance and remodeling flexibility. It is important to study indepth each problems because these problems will increase more in the future.

  • PDF

Low-frequency modes in the fluid-structure interaction of a U-tube model for the steam generator in a PWR

  • Zhang, Hao;Chang, Se-Myong;Kang, Soong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1008-1016
    • /
    • 2019
  • In the SG (steam generator) of PWR (pressurized water reactor) for a nuclear plant, hundreds of U-shaped tubes are used for the heat exchanger system. They interact with primary pressurized cooling water flow, generating flow-induced vibration in the secondary flow region. A simplified U-tube model is proposed in this study to apply for experiment and its counterpart computation. Using the commercial code, ANSYS-CFX, we first verified the Moody chart, comparing the straight pipe theory with the results derived from CFD (computational fluid dynamics) analysis. Considering the virtual mass of fluid, we computed the major modes with the low natural frequencies through the comparison with impact hammer test, and then investigated the effect of pump flow in the frequency domain using FFT (fast Fourier transform) analysis of the experimental data. Using two-way fluid-structure interaction module in the CFD code, we studied the influence on mean flow rate to generate the displacement data. A feasible CFD method has been setup in this research that could be applied potentially in the field of nuclear thermal-hydraulics.

Experimental Study on the Effect of Air Chamber Size and Operation Parameters on the Performance of a Hydraulic Ram Pump (압력실의 크기와 운전 조건에 따른 수격펌프의 성능에 대한 실험적 고찰)

  • Ngolle, Enongene Ebong George;Hong, Seong Gu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.4
    • /
    • pp.55-61
    • /
    • 2019
  • Motor pumps cannot be used in those areas where electricity is not accessible such as remote rural areas in many African countries. Hydraulic ram pump is one of the solutions for supplying water for irrigation or domestic uses. The hydraulic ram pumps are working based on the water hammer effect for pumping without external power or electricity. This study was conducted to investigate the effect of air chamber volume and operation parameters on the performance of the hydraulic ram pump which was assembled with common plumbing parts. The experimental results showed the volume of the air chamber did not affect the performance such as discharge rate and head. When drive heights were 1.7 and 2.35 m, the maximum discharge heads were up to 7 m and 10 m, respectively. When the air chamber volume was 1 L, discharge rates were 0.23 and 2.12 L/min under the drive heights of 1.7 and 2.35 m, respectively. The average energy efficiency of the hydraulic ram pump assembled in this study was about 60% for all the experimental conditions.

Development and Application of TDR Penetrometer for Evaluation of Soil Water Content of Subsoil (지반의 함수비 평가를 위한 관입형 TDR 프로브의 개발 및 적용)

  • Hong, Won-Taek;Jung, Young-Seok;Lee, Jong-Sub;Byun, Yong-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.2
    • /
    • pp.39-46
    • /
    • 2015
  • Dielectric constant depends on the variation of soil water content, and the estimation of soil water content using time domain reflectometry (TDR) has been studied by many researchers. The purpose of this study is the development and application of TDR penetrometer (TDRP) in order to evaluate the soil water content according to the penetration depth. The TDRP consists of cone, sleeve, driving rod, hammer, and guide. Three electrodes, which are used to measure the dielectric constant of soils, are mounted on the surface of sleeve and, in turn, connected with coaxial cable and time domain reflectometer. To establish the relationship between the volumetric water content and dielectric constant, several laboratory tests by using the TDRP are performed in the specimens with a variety of volumetric water content. The experimental results show that the dielectric constant is strongly correlated to volumetric water content as polynomial equations with an order of 3. In addition, the volumetric water content calculated from the dielectric constant is similar to that obtained from the sample weight. In the field, a small sampler is used to compare the volumetric water content calculated from the dielectric constant with the volumetric water content obtained from the sample. The results of field application demonstrate that the volumetric water content estimated by the TDRP shows similar trend to the gravimetric water content of sample. This study suggests that the TDRP is effectively used to evaluate the volumetric water content of unsaturated soils according to the penetration depth.

Groundwater of bed rocks in South Korean Penninsula (한반도의 암반 지하수에 관한 연구)

  • 한정상
    • Water for future
    • /
    • v.14 no.4
    • /
    • pp.73-81
    • /
    • 1981
  • More than 650 numbers of water well ranging in depth from 100M to 200M were installed in South Korean Penninsula during the last decade for the purpose of industrial use and municipal water supply. Those data were compiled and synthesized by writer to determine their hydrogeologic occurences in accordance with their geologic and areal characteristics. Rocks yielding the deep seated ground water beared in the geologic primary and secondary porosities are classified into 6 groups according to their geologic, hydrogeologic, and topographic characteristics, that are: volcanic, sedimentary, meta-sediment and/or schist, andesitic, gneissic, and granitic rocks. The order of ground water productivity of the groups is as written above. Even granitic rocks including porphyries, granite, and intermediate and basic plutonic rocks is considered to be the most poorest ground water yielding group among 6, it's average yield form a single well with average drilling depth of 116M is about 225 cubic meters per day if it's drilling site is properly located. Generally speaking, seizable geologic structures such as fractured, sheared, and faulted zone at the flat surface and valley center yield almost 310% more of deep seated bet rock ground water in comparision with minor structures of joints, bedding planes, and so on that are occured at high land. 50 numbers of water well drilled at crystalline rocks were specially checked and measured it's ground water yie 1ds at each drilled depth to determine each interval's productivity while hammer drilling was going on. The results indicate that the specific capacity and yield of each water well at a depth below 70M to 80M was almost neglegible. It means that optimum well depth of crystalline rocks, except the area having seizable geologic structures, shall be not deeper than 80M.

  • PDF