• 제목/요약/키워드: water environment

검색결과 13,308건 처리시간 0.034초

지진대비 댐안전관리를 위한 지진감시시스템 구축 및 계측기록 활용 (Development of Dam Earthquake Monioring System and Application of Earthquake Records for Dam Safety Management against Earthquake)

  • 하익수;이종욱;조성은;오병현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1389-1396
    • /
    • 2008
  • The recent Sichuan earthquake(2008) in China and Iwate-Miyazaki earthquake(2008) in Japan give Korea peninsula warning that it is no more safety zone against damage by earthquake events. So, rapid and appropriate countermeasures for dam operation and management against earthquake are needed. In Korea earthquake design standard(MOCT, 1997) has been revised after Kobe earthquake. Installation of seismometer and monitoring of earthquake for special class dams is requlated in dam aseismic design standard(MOCT, 2001). Accelerometer installation project for existing dams has been carrying out by K-water to establish an earthquake network for dam safety. Real-time dam earthquake monitoring network has also been developed to detect an earthquake efficiently and to warn to dam administrators as soon as possible. In this study, dam real-time earthquake monitoring system developed by K-water was introduced and applicability of real earthquake record measured by this system to dam safety management was illustrated.

  • PDF

격자기반의 강우유출모형을 통한 한강수계 다목적댐의 홍수유출해석 (Flood Runoff Analysis of Multi-purpose Dam Watersheds in the Han River Basin using a Grid-based Rainfall-Runoff Model)

  • 박인혁;박진혁;허영택
    • 한국물환경학회지
    • /
    • 제27권5호
    • /
    • pp.587-596
    • /
    • 2011
  • The interest in hydrological modeling has increased significantly recently due to the necessity of watershed management, specifically in regards to lumped models, which are being prosperously utilized because of their relatively uncomplicated algorithms which require less simulation time. However, lumped models require empirical coefficients for hydrological analyses, which do not take into consideration the heterogeneity of site-specific characteristics. To overcome such obstacles, a distributed model was offered as an alternative and the number of researches related to watershed management and distributed models has been steadily increasing in the recent years. Thus, in this study, the feasibility of a grid-based rainfall-runoff model was reviewed using the flood runoff process in the Han River basin, including the ChungjuDam, HoengseongDam and SoyangDam watersheds. Hydrological parameters based on GIS/RS were extracted from basic GIS data such as DEM, land cover, soil map and rainfall depth. The accuracy of the runoff analysis for the model application was evaluated using EFF, NRMSE and QER. The calculation results showed that there was a good agreement with the observed data. Besides the ungauged spatial characteristics in the SoyangDam watershed, EFF showed a good result of 0.859.

EPA-SWMM을 이용한 LID 기법의 비점오염 저감효과 분석 (Evaluation of the Effectiveness of Low Impact Development Practices in an Urban Area: Non-point Pollutant Removal Measures using EPA-SWMM)

  • 조선주;강민지;권혁;이재운;김상단
    • 한국물환경학회지
    • /
    • 제29권4호
    • /
    • pp.466-475
    • /
    • 2013
  • Non-point source pollution management is one of the most important issues in Korean water quality/watershed management. In recent years, Low Impact Development (LID) has emerged as an effective approach to control stormwater in an urban area. This study illustrates how to design and evaluate the effect of non-point pollutant management using EPA-SWMM LID module and suggests design parameters for modeling LID facilities. In addition, optimal installation locations of LID can be determined by a simple distributed hydrologic model by using SWMM for a long-term.

Improved Performance of Microbial Fuel Cell Using Membrane-Electrode Assembly

  • PHAM THE HAl;JANG JAE KYUNG;MOON HYUN SOO;CHANG IN SEOP;KIM BYUNG HONG
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권2호
    • /
    • pp.438-441
    • /
    • 2005
  • A mediator-less microbial fuel cell (MFC) was used to determine the performance effects of a membrane­electrode assembly (MEA). The MFC with an MEA generated a higher current with an increased coulomb yield when compared to an MFC with a separate cathode. Less oxygen was diffused through an MEA than through a Nafion membrane. The MFC performance was improved with a buffer, although a high-strength buffer reduced the performance.

필댐 파괴 특성에 따른 위험 요소 분석 (Risk factor analysis for failure characteristics of fill dam)

  • 임정열;오석훈;장봉석;김범주;임은상
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.794-799
    • /
    • 2006
  • For various historical reasons and some technical reasons, the safety of dams has been controlled by an engineering standards-based approach, which has developed over many years, initially for the design of new dams, but increasingly applied over the past few decades to assess the safety of existing dams. And some countries were asked for risk assessment on existing dam, which included structural, hydraulic safety of dam and social risk. So, Many countries were developed and could be adapted as an additional tool to assist in decision-making for dam safety management.

  • PDF

응집·한외여과 공정에서 응집조건 결정에 관한 연구 (Effect of Coagulation Condition on Coagulation/Ultrafiltration Membrane Process)

  • 문성용;이상협;김승현;문병현
    • 한국물환경학회지
    • /
    • 제21권4호
    • /
    • pp.379-384
    • /
    • 2005
  • In this research, coagulation was employed as the pretreatment for membrane process. The effective coagulation conditions were decided after the discussion of different coagulant doses and mixing conditions, etc. Raw water was taken from Nakdong River. The best operation occurred when G value was $230s^{-1}$ and the slow mixing lasted around 5 minutes at G value was $23s^{-1}$. To investigate the optimum coagulant dosage, the optimum organics removal was target as organic removal reduces membrane fouling effectively than particle removal. This result indicated that organics are more important causes than turbidity for membrane fouling. However, turbidity becomes an important factor after certain amount of organic matters is removed.

자외선 처리시의 의약품류의 분해도에 관한 연구 (A Study on the Degradability of Pharmaceuticals during UV Treatment)

  • 김일호
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.902-910
    • /
    • 2012
  • The photodegradation characteristics of 30 pharmaceuticals were investigated by batch experiments using Ultraviolet (UV) reactor. The investigated pharmaceuticals include antibiotics, analgesics and antiarrhythmic agents etc. Tested water was prepared by simultaneously spiking 30 pharmaceuticals into pure water, and each experiment was conducted using 3 types of UV lamps. As a result, batch experiments showed that reactions of all the investigated pharmaceuticals followed pseudo-first order reaction regardless of the applied UV lamps. Among the pharmaceuticals, Cyclophosphamide, 2-Quinoxaline carboxylic acid and Clarithromycin proved to be the most UV-resistant compounds. Contrarily, Ceftiofur, Diclofenac and Ketoprofen were easily degraded by all the UV lamps. Dissolved organic carbon (DOC) concentration hardly changed although the concentration of the pharmaceuticals concentration gradually decreased with time, indicating that the degradation of parent pharmaceuticals may produce their intermediates during UV treatment.

비균질한 천해에서의 수중음파 전파 (Underwater Sound Propagation in a range-dependent Shallow water environment)

  • 나정열
    • 한국음향학회지
    • /
    • 제6권4호
    • /
    • pp.64-73
    • /
    • 1987
  • 비균질한 천해에서의 저주파 수중음파의 전파 특성을 수치모델을 이용 분석하였다. 특히 전파매질의 비균질성이 독특한 대한해협의 겨울철 해수특성을 고려하여 음속의 수평변화, 저질두께 및 감쇠계수의 변화, 수심의 변화등 천혜의 독특한 환경 변화요인을 거의 망라한 경우를 모델로 삼았다. 음원과 수신기의 수심을 수면가까이에 둔 경우소위Mode function의 수심에 따른 특성에 의한 손실이 일반적인 손실원인보다 크게 나타났으며 Adiabatic approximation을 이용한 Mode coupling효과는 High Mode의 감쇠특성에 의해 천해에서의 모델 적용 가능성을 보여주었다.

  • PDF

비점오염원 관리지역 도출에 관한 연구 (A Study on the Designation of Nonpoint Pollution Management Region)

  • 최지용
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.434-439
    • /
    • 2007
  • Amended Water Quality Environment Preservation Law enacted that the areas where nonpoint pollution is serious can be designated as Nonpoint Source Management Region. According to Section 54 of Water Quality Environment Preservation Law, corresponding watersheds are areas where runoff from nonpoint pollution source may deteriorate river and lake water quality, residents' health and property, and ecosystem. The criteria are as followings; i) where nonpoint source contribution result in or will result in significant ecological destruction, iii) national or local industrial complexes and cities having population greater than one million where nonpoint source managements are necessary, iv) where specific measurement is necessary because of its geological and stratigraphic characteristics. In this research, detailed designation criteria was developed reflecting current nonpoint source management situation and its discharge characteristics. Depending on the result, target regions were also suggested. In additions, it will be desirable that the target regions are prioritized considering institutional execution availability, stakeholder's agreement, and connection with existing nonpoint source pollution management measures.