Browse > Article

Effect of Coagulation Condition on Coagulation/Ultrafiltration Membrane Process  

Moon, Seong-Yong (Water Environment and Remediation Center, Korea Institute of Science and Technology)
Lee, Sang-Hyup (Water Environment and Remediation Center, Korea Institute of Science and Technology)
Kim, Seung-Hyun (Department of Civil Engineering, Kyungnam University)
Moon, Byung-Hyun (Department of Environment Engineering, Changwon University)
Publication Information
Abstract
In this research, coagulation was employed as the pretreatment for membrane process. The effective coagulation conditions were decided after the discussion of different coagulant doses and mixing conditions, etc. Raw water was taken from Nakdong River. The best operation occurred when G value was $230s^{-1}$ and the slow mixing lasted around 5 minutes at G value was $23s^{-1}$. To investigate the optimum coagulant dosage, the optimum organics removal was target as organic removal reduces membrane fouling effectively than particle removal. This result indicated that organics are more important causes than turbidity for membrane fouling. However, turbidity becomes an important factor after certain amount of organic matters is removed.
Keywords
Coagulation; Fouling; Mixing condition; Ultrafiltration; Membrane process;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Jimbo, 막: 정수처리 공정의 새로운 전환, 한국물환경학회 물환경-막분리기술 심포지움, 서울, pp. 81-87 (2003)
2 Edzwald, J. K. and Benschoten, J. E., Aluminum Coagulation of Natural Organic Matter, Chemical water of wastewater treatment, Springer-Verlag, Berlin, pp. 341-359 (1990)
3 Lin, C. F., Huang, Y. J. and Hao, O. J., Ultrafiltration processes for Removing Humic Substances, Water Research, 33(5), pp. 1252-1264 (1999)   DOI   ScienceOn
4 김미숙, 정영륜, 서의훈, 송원섭, 낙동강 부영양화와 수질환경요인의 통계적 분석, 한국조류학회지, 17(2), pp. 105-115 (2002)
5 APHA, AWWA, WPCF, Standard Method for the Examination of Water and Wastewater 20th Ed., Washington DC, USA (1998)
6 권은미, 유명진, UF를 이용한 용존성 유기물질 제거시 운전조건이 파울리에 미치는 영향, 대한환경공학회지, 22(7), pp. 1183-1191 (2000)
7 US EPA, Enhanced Coagulation and Enhanced Precipitative Softening Guidance Manual, EPA 815-R-99-012, chapter 2 (1999)
8 Collins, M. R., Amy, G. L. and King, P. H., Removal of Organic Matter in Water Treatment, ASCE National Conference on Environmental Eng., Boston, July 1-3, pp. 850-864 (1985)
9 Krasner, S. W. and Amy, G., Jar-test Evaluation of Enhanced Coagulation, J. AWWA, 87(10), pp. 93-107 (1995)
10 강임석, 정철우, 한승우, 막의 재질에 따른 유기물질 성상별 흡착 특성, 대한환경공학회, 24(8). pp. 1339-1348 (2002)
11 문병현, 김승현, 이향인, 응집 현상에 따른 오염물질 제거 및 입자 형태 특성: Alum을 사용한 경우, 대한환경공학회지, 22(7), pp. 1263-1271 (2000)
12 Mulder, M., Basic Principles of Membrane Technology, KLUWER ACAD-EMIC PUBLISHERS, chapter 2-4 (1996)
13 황덕홍, 김동윤, 낙동강 수계에 대한 정수처리공정에서 응집공정의 DOC 제거특성, 상하수도학회지, 13(2), pp. 66-73 (1999)
14 Mallevialle, J., Odendaal, P. E. and Wiesner, M. R., Water Treatment Membrane Processes, McGraw-Hill, chapter 4, 16 (1996)
15 Carroll, T., King, S., Gary, S. R., Bolto, B. A. and Booker, N. A., The Fouling of Microfiltration Membranes by NOM after Coagulation Treatment, Water Research, 34(11), pp. 2861-2868 (1999)   DOI   ScienceOn
16 Fan, L., Harris, J. L., Roddick, F.A. and Brooker, N. C., Influence of the Characteristics of Natural Organic Matter on the Fouling of Microfiltration Membrane, Water Research, 35(18), pp. 4455-4463 (2001)   DOI   ScienceOn