Managerial Strategy of the Water Environment in Great Britain (영국의 수환경관리와 그 발전 방안)

  • 조윤승
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.1
    • /
    • pp.1-16
    • /
    • 1994
  • Water environment is vital for our daily life, especially all living things, next to the air environment we breathe. In this regard, Great Britain is known as one of the most developed and well experienced countries which has developed a comprehensive system of the water environment management. In England and Wales, the National Rivers Authority was established in 1989, as an independent regulatory body taking over from the 10 Regional Water Authorities responsibility for the management of water environment. In Scotland, responsibility rests River Purification Boards and Island Council while, the Department of the Environment is the sole water authority for Northern Ireland. Overall results has made by the authority together with their strategies are reviewed in this paper.

  • PDF

Changes in the Water Environment Based on the Statistical Data in the Lake Paldang (통계로 보는 팔당호 물환경 변화)

  • Yu, Soonju;Lee, Eunjeong;Park, Minji;Kim, Kapsoon;Im, Jongkwon;Ryu, Ingu;Choi, Hwangjeong;Byeon, Myeongseop;Noh, Hyeran
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.6
    • /
    • pp.688-702
    • /
    • 2018
  • Since the 1970s regulations against the pollution of drinking water have been introduced in Lake Paldang watershed area. To understand the effects of water environment management policies and the impacts of climate changes on Lake Paldang, a long-term comprehensive study of this watershed and the changes in its water environment is required. In this study, we analyzed changes in the weather, hydrology, sources of pollution, water quality, and algal development from 2000 to 2015 year based on the statistical data provided by several national information systems. While the population and amount of sewage in the Lake Paldang watershed increased by about 1.5 times, the amount of animal manure showed a decreasing trend during the same period. The wastewater also increased by about 1.5 times while the amount of water intakes rose by about 1.14 times. The water quality in front of the Paldang Dam, which is the representative monitoring site of the Lake Paldang, was stable. The annual average BOD concentration remained within 2 mg/L, which is a "Good (lb)" level according to the environment standards of Republic of Korea. The development of phytoplankton and harmful cyanobacteria were largely influenced by meteorological factors.

The Various Factors which Should Be Considered in Classifying Toxic Substances in Water and Deriving Their Effluent Limits: Focusing on the Reduction of Risk (수질유해물질의 지정 및 배출허용기준 설정 시 고려해야 하는 복합적 요인에 대한 고찰: 위해성 저감을 중심으로)

  • Bae, Hyokwan;Chung, Yun-Chul;Yang, Hyungjae;Kim, Jaehoon;Lee, Hyun Dong;Jung, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.766-775
    • /
    • 2007
  • The use of toxic chemicals was extended as the industry in Korea has grown dramatically during the last three decades. However, list of toxic substances and limit concentrations in the water environment are not consistent within management of ambient water, drinking water and industrial effluent. This article suggests the systematic framework to classify toxic substances in the water environment and deriving their effluent limits. The most important factor for decision-making to classify toxic substances is whether their concentrations in the water environment are higher than the reference concentrations, estimated by considering human health risk and ecological risk. Using a risk-based reference concentration, the ambient water quality criterion, it is possible to derive the regulatory limit concentrations of toxic substances in drinking water and in industrial effluent. The goal concentrations in the effluent, which guarantee the human and ecological safety, should be determined with scientific investigation, balancing environmental benefit and economical effect, considering availability of treatment technology and identifying characteristics of wastewater from different industries.

Characteristics of Trend and Pattern for Water Quality Monitoring Networks Data using Seasonal-kendall, SOM and RDA on the Mulgeum in the Nakdong River (경향성 및 패턴 분석을 이용한 낙동강 물금지역의 수질 특성)

  • Ahn, Jung-Min;Lee, In-Jung;Jung, Kang-Young;Kim, Jueon;Lee, Kwonchul;Cheon, Seuk;Lyu, Siwan
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.361-371
    • /
    • 2016
  • Ministry of Environment has been operating water quality monitoring network in order to obtain the basic data for the water environment policies and comprehensively understand the water quality status of public water bodies such as rivers and lakes. The observed water quality data is very important to analyze by applying statistical methods because there are seasonal fluctuations. Typically, monthly water quality data has to analyze that the transition comprise a periodicity since the change has the periodicity according to the change of seasons. In this study, trends, SOM and RDA analysis were performed at the Mulgeum station using water quality data for temperature, BOD, COD, pH, SS, T-N, T-P, Chl-a and Colon-bacterium observed from 1989 to 2013 in the Nakdong River. As a result of trends, SOM and RDA, the Mulgeum station was found that the water quality is improved, but caution is required in order to ensure safe water supply because concentrations in water quality were higher in the early spring(1~3 month) the most.

A Study on Efficiency of Water Supply through Conjunctive Operation of Reservoirs and Multi-function Weirs in the Nakdong River (낙동강수계 댐과 다기능보의 연계운영을 통한 용수공급효율화에 관한 연구)

  • Ahn, Jung Min;Im, Toe Hyo;Lee, In Jung;Lee, Kyung-Lak;Jung, Kang Young;Lee, Jae Woon;Cheon, Se Uk;Park, In Hyeok
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.2
    • /
    • pp.138-147
    • /
    • 2014
  • In order to determine the best operating rules for the Nakdong River, three cases were applied to analyze the simulated results of water supply capacity by HEC-ResSim model. This study discussed to present the best operating rules for conjunctive operating of existing the dams and new constructed the weirs through system network. The system network was constructed considering the water supply, the river environment and the operating facility. The water supply capacities are separately evaluated for each case applying the best rules. It is case1 that the dams are operated individually, case2 that the dams are operated in conjunction with the others dams, and case3 that dams and weirs are operated in conjunction with the others dams-weirs. Comparing the cases, case 3 has shown the best water supply capacity of the Nakdong River.

Manganese Removal of Bank Filtrate using Manganese Sand Filtration (망간모래여과를 이용한 강변여과수의 망간제거)

  • Kim, Chung-Hwan;Kim, Hak-Chul;Kim, Han-Seung;Kim, Berm-Soo;Ahn, Hyo-Won
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.409-414
    • /
    • 2004
  • Pilot-scale experiments were performed for the treatment of bank filtrate contammg high manganese concentration around 2mg/L using rapid manganese sand filtration to investigate effects of oxidant dose and pH control on the removal efficiency of manganese. For theoretical dose ranges of oxidant (sodium hypochlorite) between 3 and 4mg/L, the manganese concentration of effluent was 0.57 mg/L, which corresponded to 72.5% removal and was higher than drinking water quality standards of 0.3mg/L. For excess dose ranges of oxidant between 4 and 8mg/L, the manganese concentration of effluent was reduced to 0.14mg/L, which corresponded to 94.5% removal, but the residual chlorine concentration was over 1.0mg/L. On the other hand, manganese removal efficiency drastically increased up to the value of 98.0%, which is equivalent to the effluent concentration of 0.03mg/L by controling pH to the range between 7 and 8 for the theoretical dose of oxidant. Consequently, these results indicated that appropriate dose of chemicals, such as oxidant and alkali, and continuous monitoring of manganese should be necessary to obtain efficient removal of manganese and to optimize the maintenance of treatment facilities for the treatment of bank filtrate with high concentration of manganese.

A study on the effects of environmental investment and costs on environmental performance (환경 투자 및 비용이 기업의 환경성과에 미치는 영향)

  • Park, Gwang-Dueg;Park, No-Suk;Kim, Seong-Su;Seo, In-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.315-320
    • /
    • 2009
  • This study found that introduction of environmental systems and increased environmental investment have a major impact on K company's sustainable development. The analysis indicated that the environmental investment variable has a close relationship with production quantity, sales, and the amount of sludge treatment variables in K company. However, all other variables including the cost of disinfection chemicals, and the expenditure of sludge treatment have no relationship with the environmental investment variable. Additionally, short-term results show that the company's environmental expenditure variable is conversely related with the environmental performance variable.

Study on Seepage Behavior of Concrete Faced Gravel-Fill Dam (표면차수벽형사력댐의 침투거동에 관한 연구)

  • Cho, Sung-Eun;Kim, Ki-Young;Park, Han-Gyu;Ha, Ik-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.836-841
    • /
    • 2008
  • CFRD (Concrete Faced Rockfill Dam) has been world-widely constructed due to a lot of advantages compared with rockfill dam and recently, sand/gravel materials, instead of crushed rock materials, are also utilized as a main rockfill material to overcome geological and environmental problems. In this paper, the process of water infiltration into the originally unsaturated sand/gravel-fill dam is studied using two-dimensional saturated-unsaturated seepage theory. According to the results of seepage analysis, if the effective drainage zone is installed in the dam, the reservoir water infiltrate into the dam along a downward flow path towards the lower drainage area. The main body constructed with sand/gravel materials, therefore, remains unsaturated.

  • PDF

Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju (광주지역 바닥분수의 수질특성 평가)

  • Kim, Jong-Min;Kim, Ha-Ram;Jang, Seo-Eun;Choi, Yeong-Seop;Kang, Yu-Mi;Jung, Sook-Kyoung;Cho, Young-Gwan;Kim, Eun-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.143-156
    • /
    • 2017
  • The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.