• 제목/요약/키워드: water chemistry factors

검색결과 191건 처리시간 0.032초

Simultaneous Kinetic Spectrophotometric Determination of Sulfite and Sulfide Using Partial Least Squares (PLS) Regression

  • Afkhami, Abbas;Sarlak, Nahid;Zarei, Ali Reza;Madrakian, Tayyebeh
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권6호
    • /
    • pp.863-868
    • /
    • 2006
  • The partial least squares (PLS-1) calibration model based on spectrophotometric measurement, for the simultaneous determination of sulfite and sulfide is described. This method is based on the difference between the rate of the reaction of sulfide and sulfite with Malachite Green in pH 7.0 buffer solution and at 25 ${^{\circ}C}$. The absorption kinetic profiles of the solutions were monitored by measuring the decrease in the absorbance of Malachite Green at 617 nm in the time range 10-180 s after initiation of the reactions with 2 s intervals. The experimental calibration matrix for partial least squares (PLS-1) calibration was designed with 24 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range 0.030-1.5 and 0.030-1.2 $\mu$g m$L ^{-1}$ for sulfite and sulfide, respectively. The proposed method was successfully applied to simultaneous determination of sulfite and sulfide in water samples and whole human blood.

Evaluation of Loess Capability for Adsorption of Total Nitrogen (T-N) and Total Phosphorous (T-P) in Aqueous Solution

  • Kim, Daeik;Ryoo, Keon Sang;Hong, Yong Pyo;Choi, Jong-Ha
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권8호
    • /
    • pp.2471-2476
    • /
    • 2014
  • The aim of the present study is to explore the possibility of utilizing loess for the adsorption of total phosphorous (T-P) and total nitrogen (T-N) in water. Batch adsorption studies were performed to evaluate the influences of various factors like initial concentration, contact time and temperature on the adsorption of T-P and T-N. The adsorption data showed that loess is not effective for the adsorption of T-N. However, loess exhibited much higher adsorption capacity for T-P. At concentration of $1.0mgL^{-1}$, approximately 97% of T-P adsorption was achieved by loess. The equilibrium data were fitted well to the Langmuir isotherm model. The pseudo-second-order kinetic model appeared to be the better-fitting model because it has higher $R^2$ compared with the pseudo-first-order and intra-particle kinetic model. The theoretical adsorption equilibrium $q_{e,cal}$ from pseudo-second-order kinetic model was relatively similar to the experimental adsorption equilibrium $q_{e,exp}$. The thermodynamic parameters such as free energy ${\Delta}G$, the enthalpy ${\Delta}H$ and the entropy ${\Delta}S$ were also calculated.

역상 액체크로마토그래피에서 벤젠 일치환체들의 머무름 메카니즘에 관한 연구 (Ⅰ). 벤젠 일치환체들의 용리거동 (A Study of the Retention Mechanism of the Monosubstituted Benzenes in Reversed-Phase Liquid Chromatography (Ⅰ). The Elution Behavior of the Monosubstituted Benzenes)

  • 이대운;최용욱;김현주;정용순
    • 대한화학회지
    • /
    • 제31권1호
    • /
    • pp.55-63
    • /
    • 1987
  • 본 연구는 결합 정지상 컬럼을 이용한 역상 액체 크로마토그래피에서 치환기에 따른 시료의 용리거동을 알아 보기 위한 일련의 연구로서 비교적 극성인 치환체에서 비극성인 치환체까지 18종의 벤젠 일치환체를 대상으로 $\mu$-Bondapak $C_{18} 컬럼 및 $\mu$-Bondapak phenyl컬럼상에서 메탄올-물, 아세토니트릴-물, 및 THF-물의 혼합용액을 이동상으로 하여 시료의 용리거동을 알아 보았다. 극성인 치환기를 갖는 치환체들의 용량인자(k')는 벤젠에 k'값보다 적었으며, 반대로 비극성인 치환체들의 k'값은 벤젠보다 컸다. 이동상중의 유기용매의 농도가 감소함에 따라 모든 벤젠 일치환체들의 용량 인자값은 증가하였다. 혼합물의 분리의 가능성을 예측하고 치환체들의 용리거동을 설명하기 위하여 컬럼의 종류 및 이동상의 종류에 따라 달라지는 각 치환체들의 머무름의 변화를 벤젠을 기준으로 하여 용량인자의 절대치의 차(${\Delta}k$')로 도식화하였다. 두 컬럼과 세가지 용매시스템에서 치환체들의 용량인자를 상호 비교하므로써 선택성이 큰 용매시스템을 조사하였다.

  • PDF

Preparation of diffusion dialysis membrane for acid recovery via a phase-inversion method

  • Khan, Muhammad Imran;Wu, Liang;Hossain, Md. Masem;Pan, Jiefeng;Ran, Jin;Mondal, Abhishek N.;Xu, Tongwen
    • Membrane and Water Treatment
    • /
    • 제6권5호
    • /
    • pp.365-378
    • /
    • 2015
  • Herein, the preparation of anion exchange membrane (AEM) from brominated poly(2,6-dimethyl 1,6-phenylene oxide) BPPO and dimethylaniline (DMA) by phase-inversion process is reported. Anion exchange membranes (AEMs) are prepared by varying the DMA contents. Prepared AEMs show high thermal stability, water uptake (WR) around 202% to 226%, dimensional change ratios of 1.5% to 2.6% and ion exchange capacities (IECs) of 0.34 mmol/g to 0.82 mmol/g with contact angle of $59.18^{\circ}$ to $65.15^{\circ}$. These membranes are porous in nature as confirmed by SEM observation. The porous property of membranes are important as it could reduce the resistance of transportation of ions across the membranes. They have been used in diffusion dialysis (DD) process for recovery of hydrochloric acid (HCl) from the mixture of HCl and ferrous chloride ($FeCl_2$). Presence of $-N+(CH_3)_2C_6H_5Br^-$ as a functional group in membrane matrix facilitates its applications in DD process. The dialysis coefficients of hydrochloric acid ($U_H$) of the membranes are in range of 0.0016 m/h to 0.14 m/h and the separation factors (S) are in range of 2.09 to 7.32 in the $HCl/FeCl_2$ system at room temperature. The porous membrane structure and presence of amine functional group are responsible for the mechanism of diffusion dialysis (DD).

분극곡선 측정을 통한 전해부상조의 설계인자 평가 (Evaluation on Design Factors of Electrolytic Flotation Reactor by Measuring Polarization Curve)

  • 임봉수;김경수;최찬수
    • 한국물환경학회지
    • /
    • 제23권2호
    • /
    • pp.244-250
    • /
    • 2007
  • This study was carried out to obtain the optimum design factors for an eletrolytric flotation reactor. When the effluent of the leachate treatment facility was treated under the condition of 10 volts, 30 minutes, at the Al-Al electrode system; COD removal efficiency was 45%, and total phosphorus removal efficiency was 98%. The high removal efficiency was caused by the fact that phosphate was removed by leaching $Al^{3+}$ from two electrodes. The leachate containing high ammonium nitrogen concentration was treated by a batch test under the condition of 60 minutes reaction time and added chloride ion; ammonium nitrogen removal efficiency was 89%. This high efficiency was affected by added chloride ion to wastewater. To find the optimum current density and voltage of the leachate containing chloride ion (ratio of $Cl^-/NH_4-N$ is 11) a electrochemical polarization curve was used. These values were found to be $4.5mA/cm^2$ and about 2.1 V, respectively. When C-Al electrode system was used at a batch test, the total nitrogen removal efficiency was increased by 1.8 to 3.3 times, compared to Al-Al electrode system due to high $Cl_2$ gas production.

염소이온의 확산모델에 의한 염해를 받는 콘크리트 구조물의 내구성 예측연구 (A Study on the Prediction of Durability of Concrete Structures Subjected to Chloride Attack by Chloride Diffusion Model)

  • 오병환;장승엽;차수원;이명규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.254-260
    • /
    • 1997
  • Chloride-induced corrosion of reinforcement is one of the main factors which cause the deterioration of concrete structures. Durability and service lives of the concrete sturctures should be predicted in order to minimize the risk of corrosion of reinforcement. The objective of this study is to suggest the basis of analytical methods of predicting the corrosion threhold time of concrete structures. Based on the chemistry and physics of chloride ion transport and corrosion process, chloride intrusion with various exposure conditions, variability of diffusivity and transport of pore water in concrete are taken into consideration in applying finite element formulation to the predicion of corrosion threhold time. The effects of main factors on the prediction of chloride intrusion and corrosion threhold time are examined. In addition, after chloride diffusivities of several mixture proportions with different parameters are measured by chloride diffusion test, the exemplary anayses of corrosion threhold time of those mixture proportions are carried out.

  • PDF

Dithiopyr(MON-7200)의 제초작용특성(除草作用特性)에 관(關)한 연구(硏究) - 2. Dithiopyr의 제초효과(除草效果) 변동요인(變動要因) (Studies on the Herbicidal Properties of Dithiopyr(MON-7200) - 2. Variation of Weeding Effect of Dithiopyr)

  • 양환승;최연철;최은석;김창봉
    • 한국잡초학회지
    • /
    • 제9권3호
    • /
    • pp.238-244
    • /
    • 1989
  • 신규(新規) 제초제(除草劑)에 dithiopyr의 제초효과(除草效果) 변화(變化)에 미치는 각종(各種) 재배(栽培) 화경조건(環境條件)의 영향(影響)에 대하여 조사(調査)한 바 다음과 같은 결과(結果)를 얻었다. Dithiopyr는 추천약량(推薦藥量)의 1/3수준(水準)인 0.04kg a.i./ha 약량(藥量)에서도 피, 물달개비 등에 대하여 89.3% 이상의 효과(效果)가 있었고, 0.08kg a.i./ha 약량(藥量) 이상부터는 100%의 방제율(防除率)을 보였다. 제초효과(除草效果)는 토성(土性), 누수량(漏水量), 온도(溫度), 담수심(湛水深), 관수시간(換水時間)의 차이(差異)에 따른 영향을 거의 받지 않았다. 제초효과(除草效果)는 이앙전(移秧前) 처리(處理) 혹은 이앙(移秧) 후(後) 12일 이상(以上)의 처리(處理)보다는 5-8일 처리(處理)가 높았다.

  • PDF

초연약 준설토의 증발 및 건조특성 분석 (Evaporation and Desiccation of Soft Dredged Clay)

  • 정하익;오인규;지성현;이승원;이영남;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.217-222
    • /
    • 2000
  • An understanding of the behaviour of soft clay soils is important in a large number of civil engineering applications, including dredging operations, land reclamation and slurry management such as disposal and storage. Although the details of the behaviour depend on parameters such as the soil mineralogy, the pore water chemistry, the organic content and the microbiology, there are general features that are typical in many cases. The purpose of this paper is to present and discuss some of evaporation and desiccation observed in laboratory experiments under controlled conditions. Desiccation of dredged material is basically removal of water by evaporation which is controlled by weather and material type, etc. This study shows that (1) solar radiation, (2) wind velocity, (3) material depth, (4) trench depth are important factors in desiccation of dredged ultra soft clay.

  • PDF

Degradation of 1,4-Dioxane using $O_3$/$H_2O_2$

  • Suh, Jung-Ho;Mohseni, Madjld
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.139-144
    • /
    • 2003
  • 1, 4-dioxane is a recalcitrant pollutant found in contaminated ground waters and industrial effluents. Conventional water treatment techniques are limited to treat this compound effectively. In this study, $O_3$$H_2O_2$ oxidation process was used to eliminate 1, 4-dioxane in water and to enhance the biodegradability. Several factors affecting biodegradability enhancement were investigated. The relationship between initial oxidation rate of 1 A-dioxane and BOD enhancement rate has been determined, a kinetic model has been proposed. $H_2O_2$ concentration and pH had a proportional relation with biodegradability of 1, 4-dioxane, but in case of ozone, there was no relationship with biodegradability. 1, 4-Dioxane removal efficiencies had good agreement with the biodegradability.

  • PDF

청주지역의 도심하천인 미호천에서 시공간적 수질변이 특성 및 유입지천의 영향 (Spatial and Temporal Variations of Water Quality in an Urban Miho Stream and Some Influences of the Tributaries on the Water Quality)

  • 김지일;최지웅;안광국
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.433-445
    • /
    • 2014
  • The objective of study was to analyze seasonal and inter-annual patterns of water chemistry of Miho Stream watershed during 2004 - 2007 along with some influences of tributaries and summer monsoon on the stream water quality. For the study, eight physico-chemical parameters such as nitrogen, phosphorus, BOD, COD and chlorophyll-a (CHL) etc. were analyzed in relation to spatial and temporal variability of seven sampling sites of the mainstream and some tributaries in the watershed. In the upstream reach, Mean of BOD, COD and TP averaged 3.2 mg/L, 6.5 mg/L and $186{\mu}g/L$, respectively, indicating an eutrophic conditions as a III-rank in the stream water quality criteria from the Ministry of Environment, Korea(MEK). The eutrophic water was due to a combined effect of Chiljang tributary with high nutrients ($TP=844{\mu}g/L$, TN=8.087 mg/L) and the point sources from some wastewater treatment plants. In the meantime, BOD, TN, and TP in the downstream reach were about > 1.2-1.5 folds than the values of the midstream reaches. This was mainly attributed to effluents of nutrient rich-water (mean TN: 11.980 mg/L) from two tributaries of Musim Stream and Suknam Stream, which is directly influenced by nearby wastewater disposal plants. Seasonal analysis of water chemistry showed that summer monsoon rainfall was one of the important factors influencing the water quality, and water quality had a large spatial heterogeneity during the rainfall period. In the premonsoon, BOD in the downstream averaged $6.0{\pm}2.47mg/L$, which was 1.4-fold greater than the mean of upstream reach. Mean of CHL-a as an indicator of primary productivity in the water body, was > 2.2 - 2.9 fold in the downstream than in the upstream, and this was a result of the high phosphorus loading from the watershed. Overall, our data suggest that some nutrient controls in point-source tributary streams are required for efficient water quality management of Miho Stream.