• 제목/요약/키워드: water addition

검색결과 9,523건 처리시간 0.038초

데이터센터 냉방시스템 고효율화를 위한 국내 수열에너지 보급 제도 개선에 관한 연구 (A Study on the Improvement of the Water Source Energy Distribution Regulation for High Efficient Data Center Cooling System in Korea)

  • 조용;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.21-29
    • /
    • 2021
  • In this study, the current regulation of the water source energy, one of the renewable energy, was analyzed, and the improvement plan for the high efficient data center cooling system was suggested. In the improvement plan, the design and construction guidelines of the water source energy system permit to adopt the cooling and heating system with or without heat pump. In addition, it should also include the system operated in the cooling mode only all year-round. The domestic test standards to consider the water source operating conditions should be developed. Especially, it is highly recommended that the test standards to include the system with forced cooling and free cooling modes related with the enhanced data center cooling system adopting the water source energy.

물수요 중심 용수공급시스템 활용을 위한 국내 농업용수 공급체계 분석 (Analysis of Agricultural Water Distribution Systems for the Utilization of Water-Demand-Oriented Water Supply Systems)

  • 이광야;최경숙
    • Current Research on Agriculture and Life Sciences
    • /
    • 제31권2호
    • /
    • pp.139-147
    • /
    • 2013
  • This study analyzed agricultural water distribution systems for the utilization of water demand-oriented water supply systems. Three major TM/TC(telemeter/telecontrol) districts of agricultural water management were selected for analyzing the characteristics of the water distribution systems. In addition, the characteristics of the water supply systems for general water supply zones based on irrigation facilities were also investigated, along with the case of special water management during the drought season. As a result, high annual and monthly variations were observed for the water supply facilities, including the reservoirs and pumping stations. In particular, these variations were more obvious during the drought season, depending on the type of facility. The operations of the pumping stations and weirs were more sensitive to the stream levels than the reservoirs, and the smaller reservoirs were influenced more than the larger reservoirs. Therefore, a water-demand-oriented water supply system should consider the existing general practices of water management in the agricultural sector, and focus on achieving a laborsaving system rather than water conservation in the case of reservoirs. Equal water distribution from the start to the end point of irrigation channels could be an effective solution for managing pumping stations.

  • PDF

상수원 관망 부식 제어를 위한 부식성 수질 관리: 북미지역 관리 사례 및 국외 현황 (The Regulations and Guidelines for Management of Corrosive Water and Pipe Corrosion in Drinking Water Distribution System in North America)

  • 김민희;현승훈;이원석
    • 한국물환경학회지
    • /
    • 제33권3호
    • /
    • pp.359-369
    • /
    • 2017
  • Water distribution systems supply drinking water to consumers' taps. Internal corrosion of metallic pipe used in drinking water distribution systems has reduced water quality and led to increased levels of toxic heavy metals such as lead, copper and nickel. These problems have been experienced to varying degrees by water utilities in many countries. North America has successfully managed and controlled pipe corrosion and corrosive water in water distribution system based on various policies, regulations and rules. Practical and engineering guidelines for evaluation of pipe corrosion and determination of treatment options are also provided to assist drinking water supplies. In addition, the corrosion mechanism in water distribution systems, such as the complex effects of physical and chemical parameters on the corrosion pipes has been improved to accurately predict corrosion rates of metallic pipes in actual water distribution systems. This paper reviews various regulations, policy statement, and treatment produces on controlling corrosion in drinking water distribution systems in US and Canada and then offers suggestion for management of corrosive water and pipe corrosion in drinking water distribution system in Korea.

고주파유도결합에 의해 여기된 물플라즈마로부터 고효율 수소생산을 위한 메탄가스 첨가효과 (Effect of $CH_4$ addition to the $H_2O$ plasma excited by VHF ICP for production of $H_2$)

  • 김대운;추원일;장수욱;정용호;이봉주;김영호;이승헌;권성구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.442-442
    • /
    • 2008
  • Hydrogen was produced by water plasma excited in very high frequency inductively coupled tube reactor. Mass spectrometry was used to monitor gas phase species at various process conditions. Water dissociation rate depend on the process parameters such as ICP power, flow-rate and pressure. Water dissociation percent in ICP reactor decrease with increase of chamber pressure and $H_2O$ flow rate, while increase with increase of ICP power. In our experimental range, maximum water dissociation rate was 65.5% at the process conditions of 265 mTorr, 68 sccm, and 400 Watt. The effect of $CH_4$ addition to a water plasma on the hydrogen production has been studied in a VHF ICP reactor. With the addition of $CH_4$ gas, $H_2$ production increases to 12% until the $CH_4$ flow rate increases up to 15 sccm. But, with the flow rate of $CH_4$ more than 20 sccm, chamber wall was deposited with carbon film because of deficiency of oxygen in gas phase, hydrogen production rate decreased. The main roles of $CH_4$ gas are to reacts with O forming CO, CHO and $CO_2$ and releasing additional $H_2$ and furthermore to prevent reverse reaction for forming $H_2O$ from $H_2$ and $O_2$. But, $CH_4$ addition has negative effects such as cost increase and $CO_x$ emission, therefore process optimization is required.

  • PDF

헤이즐넛 첨가에 따른 청국장의 품질 특성 변화 (Changes in the Quality Characteristics of Cheonggukjang prepared with Hazelnut)

  • 김종덕;이영현;이난희;김대현;최웅규
    • 한국식품영양학회지
    • /
    • 제31권6호
    • /
    • pp.926-932
    • /
    • 2018
  • This research was conducted to investigate the changes in quality characteristics of cheonggukjang fermented with the addition of hazelnut (10, 20, 30 and 40%) including; water content, pH, hydrophilic and lipophilic substances, color, viscosity and angiotensin converting enzyme inhibition activity. There was no significant change in pH with the addition of hazelnut. The water content significantly decreased with the addition of hazelnut. Hazelnut was also found to brighten the color of cheonggukjang. L-value and b-value increased with the addition of cheonggjuang. There was an insignificant change in the a-value. There was a slight decrease in the content of hydrophilic with addition of hazelnuts. Where there was more than 20% addition of hazelnut to soybean, the viscous substance content in cheonggukjang decreased significantly. Angiotensin converting enzyme inhibitory activity increased proportionally to the amount of hazelnut added. It was identified that the addition of 40% of hazelnut made its angiotensin converting enzyme inhibitory activity 10% point higher than that of control. These results suggests that the addition of hazelnut makes it possible to produce cheongkukjang of excellent angiotensin converting enzyme inhibitory activity.

강변여과에서의 은나노입자의 영향 : 실험실규모 컬럼 실험 (Effect of silver nanoparticles on the performance of riverbank filtration: Column study)

  • 이동현;노진형;김현철;최재원;최일환;맹승규
    • 상하수도학회지
    • /
    • 제29권1호
    • /
    • pp.77-88
    • /
    • 2015
  • Soil column experiments were evaluated effects of silver nanoparticles (i.e., 0, 2.5, 5, and 10 mg/L) on the microbial viability which is strongly associated with the degradation of organic matter, pharmaceutically active compounds(PhACs) and biological oxidation of nitrogenous compounds during river bank filtration. The addition of silver nanoparticles resulted in almost no change in the aqueous matrix. However, the intact cell concentration decreased with addition of silver nanoparticles from 2.5 to 10 mg/L, which accounted for 76% to 82% reduction compared to that of control (silver nanoparticles free surface water). The decrease in adenosine triphosphate was more pronounced; thus, the number and active cells in aqueous phase were concurrently decreased with added silver nanoparticles. Based on the florescence excitation-emission matrix and liquid chromatograph - organic carbon detection analyses, it shows that the removal of protein-like substances was relatively higher than that of humic-like substances, and polysaccharide was substantially reduced. But the extent of those substances removed during soil passage was decreased with the increasing concentration of silver nanoparticles. The attenuation of ionic PhACs ranged from 55% to 80%, depending on the concentration of silver nanoparticles. The attenuation of neutral PhACs ranged between 72% and 77%, which was relatively lower than that observed for the ionic PhACs. The microbial viability was affected by silver nanoparticles, which also resulted in inhibition of nitrifiers.

미세물분무 작동에 대한 FDS 예측 성능 평가 (Estimation of FDS Prediction Performance on the Operation of Water-Mist)

  • 고권현
    • 한국산학기술학회논문지
    • /
    • 제15권8호
    • /
    • pp.4809-4814
    • /
    • 2014
  • 본 논문은 미세물분무 작동에 따른 화재 거동 및 제압 특성을 예측하는 데 있어서 FDS(Fire Dynamic Simulator)의 예측 성능을 평가하는 것을 목적으로 한다. 미세물분무의 초기액적분포 입력을 위해 Rosin-Rammler /log-normal 분포를 사용하였으며 모델 상수의 영향을 살펴보았다. 또한 미세물분무의 분사압력에 따른 화재 제압특성을 이전의 실험 결과와 비교함으로써 해석 모델을 검증하고 열유동 특성 및 가스 농도 변화를 분석하였다. 결과로부터 동일한 평균입경을 갖는 미세물분무도 액적분포의 특성에 따라 하부 위치에서의 액적 크기 및 속도에 큰 영향을 받고 있음을 확인할 수 있었다. 분무특성에 대한 실험결과와의 비교를 통해 적절한 초기입경분포를 결정하였으며 이를 이용하여 화재 시뮬레이션을 진행하였다. FDS 화재 시뮬레이션 결과는 온도의 변화 및 화재 제압 특성에 대하여 실험 결과와 좋은 일치를 보여주었다. 또한 미세물분무의 작동압력에 따른 열유동장 변화, 가스상 농도 변화의 예측에 있어 유용한 데이터를 제공할 수 있음을 확인하였다.

추출시간, 추출온도 및 가수율이 쇠고기의 열수추출물에 미치는 영향 (Effects of Extraction Time, Temperature and Amount of Added Water on Beef Extracts by Hot Water)

  • 유익종;김경환;김영언;박우문
    • 한국식품과학회지
    • /
    • 제22권7호
    • /
    • pp.858-864
    • /
    • 1990
  • 본 실험은 쇠고기로부터 열수추출물을 효과적으로 얻기 위하여 추출시간. 추출온도 및 가수율 등이 쇠고기 열수추출물의 추출율에 미치는 영향을 검토하기 위하여 실시하였다. 쇠고기 열수추출물은 3가지 서로 다른 추출조건에 따라 추출되었으며, 각 추출조건에서의 총질소, 비단백태 질소 및 콜라젠 단백질의 추출함량 및 수율을 측정하였다. 열수추출방법으로 쇠고기로부터 쇠고기 추출물을 생산하기 위해서는 추출온도 $97^{\circ}C$, 가수량 2.5배, 추출시간 75분의 추출조건이 가장 효율적이었으며 가압 추출의 경우에는 가수량 2배로서 가압추출온도는 $125^{\circ}C$에서 30분간 추출하는 것이 효율적으로 나타났다.

  • PDF

투과증발 PVA 분리막의 물 흡수 거동 및 물성 연구 (A Study on Water Uptake Behavior and Properties of Pervaporation PVA Membrane)

  • 김광제;박인준;김동권;이수복
    • 멤브레인
    • /
    • 제5권2호
    • /
    • pp.74-80
    • /
    • 1995
  • 상번전법의 침적조건을 변화시켜 poly(vinyl alcohol)(PVA) 분리막을 제조하고 침적조건이 분리막의 물 흡수에 미치는 영향을 조사하였다. 침적시간의 증가에 딸 분리막의 물 흡수도는 증가하다가 감소하는 경향을 보였으며, 침적온도가 낮을수록 분리막의 물 흡수도가 다소 증가하는 경향을 보였다. 침적용액에 비이온 계면활성제를 첨가하는 것은 침적용액의 표면장력을 감소시켜 침적시간 단축에는 효과적이었으나, 분리막의 물 흡수도의 최고치를 변화시키지 못하였다. 또한, 분리막의 물 흡수도와 분리막의 분리 특성 및 기계적 물성과의 관계를 조사하였다. 분리막의 물 흡수도가 증가함에 다라 분리막의 투과증발 분리 특성의 선택도는 감소하고 투과속도는 증가하였다. 분리막의 물 흡수도의 증가에 따라 분리막의 인장강도와 신율은 증가하다가 최고값을 정점으로 하여 급격히 감소하였다.

  • PDF

하수처리시설 고상시료 중 잔류의약물질 분석을 위한 전처리법 평가 및 적용 (Evaluation and application of pretreatment methods for pharmaceuticals and personal care products in the solid phase of sewage samples)

  • 박준원;김창수;주병규;이원석;정현미;정동환
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.559-572
    • /
    • 2018
  • The aim of this study was to evaluate pretreatment methods for 27 pharmaceuticals and personal care products (PPCPs) in various sewage samples using a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) and online solid-phase extraction with LC-MS/MS. Extraction efficiencies of PPCPs in the solid phase under different experimental conditions were evaluated, showing that the highest recoveries were obtained with the addition of sodium sulfate and ethylenediaminetetraacetic acid disodium salt dehydrate in acidified conditions. The recoveries of target compounds ranged from 91 to 117.2% for liquid samples and from 61.3 to 137.2% for solid samples, with a good precision. The methods under development were applied to sewage samples collected in two sewage treatment plants (STPs) to determine PPCPs in liquid and solid phases. Out of 27 PPCPs, more than 19 compounds were detected in liquid samples (i.e., influent and effluent) of two STPs, with concentration ranges of LOQ-33,152 ng/L in influents and LOQ-4,523 ng/L in effluents, respectively. In addition, some PPCPs such as acetylsalicylic acid, ibuprofen, and ofloxacin were detected at high concentrations in activated sludge as well as in excess sludge. This methodology was successfully applied to sewage samples for the determination of the target compounds in STPs.