• 제목/요약/키워드: wastewater flow

검색결과 671건 처리시간 0.026초

응집제와 관형막을 활용한 CMP 폐수 처리 가능성 연구 (The Feasibility Study of CMP Wastewater Treatment Using Tubular Membrane and Coagulants)

  • 정호찬;정철중;송자연;김연국;이선용
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.639-645
    • /
    • 2012
  • The purpose of this study is to identify the possibility of the CMP wastewater treatment from semiconductor fabrication under operating tubular membrane with coagulants. To find suitable coagulants treating CMP wastewater, we conducted Jar-test. After Jar-test experiments suitable coagulants are PAC(17%), $Ca(OH)_2$ and optimum coagulant dosage is PAC(17%) 10mg/L, $Ca(OH)_2$ 110 ~ 120mg/L. Based on these results, the tubular membrane was applied to CMP wastewater, the turbidity removal efficiency is $Ca(OH)_2$ > PAC(17%) > Nothing. The fast cross-flow velocity and backwash process what are operating characteristics of tubular membrane can be stable CMP wastewater treatment. But when the coagulant and tubular membrane are used at the same time, the withdraw and treatment of the CMP wastewater are possibile. However further treatment process needs if treated water will be used for semiconductor fabrications.

한지자숙폐액을 이용한 Saccharomyces cerevisiae의 배양에서 온-라인 FIA시스템에 의한 Glucose의 자동분석 및 첨가에 의한 증균 (Increase of Cell Concentration by the Automatic Analysis and Addition of glucose with an On-line Flow Injection Analysis System int he Cultivation of Saccharomyces cerevisiae Using a Korean Paper Digestion Wastewater)

  • 이형춘
    • KSBB Journal
    • /
    • 제15권4호
    • /
    • pp.388-392
    • /
    • 2000
  • 한지자숙폐액을 이용한 Saccharomyces cerevisiae의 배양에 서 glucose의 자동분석 및 첨가에 의해 균농도를 증가시킴으로써 폐액의 재이용성을 향상시키파 하였다 배양액의 glucose를 자동분석하고 자동첨가하기 위하여 ceramic sampler, sampling, ralve, injection valve, glucose oxidase column, debubbler, flow cell과 백금전극, potentiostat, computer와 interface card, 및 tubing pump블로 구성된 glucose 자동분석 및 첨가시스템을 제작하였으며, glucose의 자동분석에는 glucose oxidase를 이용한 on-line FIA법을 채택하였다. 효모의 배양중 glucose자 동분석 및 첨가시스템을 사용하여 glucose를 자동첨가한 결과 배양액의 포도당농도가 $176{\pm}31 mg/L$ 의 낮은 농도로 제어 되었으며, glucose와 $>(NH_4)_2S0_4$의 첨가에 의해 총균수가 3.1 배 증가하였다.

  • PDF

중공사막 모듈을 이용한 정삼투 공정에서의 운영조건 변화에 따른 성능평가 (Performance evaluation of forward osmosis (FO) hollow fiber module with various operating conditions)

  • 김봉철
    • 상하수도학회지
    • /
    • 제32권4호
    • /
    • pp.357-361
    • /
    • 2018
  • Forward osmosis (FO) process has been attracting attention for its potential applications such as industrial wastewater treatment, wastewater reclamation and seawater desalination. Particularly, in terms of fouling reversibility and operating energy consumption, the FO process is assumed to be preferable to the reverse osmosis (RO) process. Despite these advantages, there is a difficulty in the empirical step due to the lack of separation and recovery techniques of the draw solution. Therefore, rather than using FO alone, recent developments of the FO process have adapted a hybrid system without draw solution separation/recovery systems, such as the FO-RO osmotic dilution system. In this study, we investigated the performance of the hollow fiber FO module according to various operating conditions. The change of permeate flow rate according to the flow rates of the draw and feed solutions in the process operation is a factor that increases the permeate flow rate, one of the performance factors in the positive osmosis process. Our results reveal that flow rates of draw and feed solutions affect the membrane performance, such as the water flux and the reverse solute flux. Moreover, use of hydraulic pressure on the feed side was shown to yield slightly higher flux than the case without applied pressure. Thus, optimizing the operating conditions is important in the hollow fiber FO system.

사이드스트림 오존 접촉조에서 수처리 효율 향상을 위한 정적혼합기와 미세기포에 관한 연구 (A Study on the Static mixer and Microbubble of the Sidestream Ozone Contact System to Improve Water Treatment Efficiency)

  • 김진훈;박종호
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.763-768
    • /
    • 2009
  • Ozone is a strong oxidant and a powerful disinfectant. In general, it has been used in drinking water treatment during last 100years. Ozone dissolution features are defined by the two categories of ozone contactors, bubble-diffuser and sidestream ozone contactor. Currently, sidestream-injection systems are gaining in popularity but operating cost might be slightly higher. Sidestream ozone system dissolve ozone into a sidestream flow via an injection setup or in the main process flow stream in some sidestream arrangements. The sidestream flow is subsequently mixed with the main process flow stream, which is directed to a reation tank or pipeline for oxidation and disinfection reactions. The purpose of this study is to suggest optimal operating pressure, to figure out the static-mixer effect and to understand the microbubble characteristics of ozone to improve dissolution efficiency.

도시화(都市化)에 의한 지하수환경(地下水環境)의 변화(變化) (Environmental Change of Groundwater due to Urbanization)

  • 김수원;배상근
    • 상하수도학회지
    • /
    • 제10권1호
    • /
    • pp.69-77
    • /
    • 1996
  • To evaluate the change of the groundwater flow and the water table response resulting from urbanization, two cases of the transient three-dimensional numerical simulations were performed. Variations of the groundwater flow system caused by withdrawals were analyzed. Two cases of infiltration rates were applied in this study to verify the water table changes. One is the rate under the circumstance during 1994 and the other is the revised rate. The numerical results from this study indicated that groundwater flow was influenced by human impacts. Groundwater flow has been concentrated to Taegu Textile Complex area where had large amount of pumping. Water table so far decreased -2.76m a year due to withdrawals. Water tables of many points were increased more than 30cm when the surface was reformed by infiltrating the rainfall. It was appeared that the improvement of surface to recharge the precipitation was very important to preserve and manage for the groundwater.

  • PDF

CFD에 의한 와류방지장치(AVD)가 설치된 흡수정내 펌프의 성능평가에 관한 연구 (Study on Performance Analysis of Pump within Sump Model with AVD installation by CFD)

  • 최종웅;박노석;김성수;박상수;이영호
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.463-469
    • /
    • 2012
  • The efficiency of the flow mixed pump installed within the bell-mouth in the sump is reduced by the flow characteristics of around intakes. Strong submerged vorticies can be successfully suppressed by installing an AVD(anti-submerged vortex device) on the bottom of pump intake channel just below the bell-mouth. Sump model with AVD device basin is designed and the characteristics of submerged vortex is investigated in the flow field by numerical simulation. In this study, a commercial CFD code is used to predict the efficiency of the pump with the AVD installation in the pump station accurately.

갈수기(渴水期) 하천(河川)에서의 오염물질(汚染物質)의 확산(擴散) 및 이동(移動) (Low Flow Pollutant Transport in Natural Rivers)

  • 서일원
    • 상하수도학회지
    • /
    • 제7권1호
    • /
    • pp.29-36
    • /
    • 1993
  • The complex nature of low flow mixing in natural channels has been investigated using both laboratory experiments and the numerical solution of a proposed mathematical model that is based on a set of mass balance equations describing the mixing and mass exchange mechanisms. Laboratory experiments, which involved collection of channel geometry, hydraulic, and dye dispersion test data, were conducted in a model of four pool and riffle sequences in a 49-m long tilting flume. The experimental results show that flow over the model pool-riffle sequences is highly non-uniform. Concentration-time curves are significantly skewed with long tails. Comparison between measured and predicted concentration-time curves shows good agreement in the general shape, peak concentration and time to peak. The proposed model shows significant improvement over the conventional one-dimensional dispersion model in predicting natural mixing processes in open channels under low flow conditions through pools and riffles.

  • PDF

Jet flow 발생지역에서의 퇴사 거동 (A Study on the Movement of Sediment in Jet Flow Zone)

  • 정병건;이관수;이영석
    • 상하수도학회지
    • /
    • 제11권3호
    • /
    • pp.105-111
    • /
    • 1997
  • Taken from the entrance of Juam Dam to 11km long as survey, this study predicted the bed change according to the movement of sediment in jet flow zone. The result of applying compound model and jet model turned out to be satisfactory, though the latter was the better. The jet constant of Juam Dam could be controlled between 0.5 and 0.65. In the jet flow zone of the dam, the prediction of the bed change by the numerical motel showed almost the same to the observed data.

  • PDF

전기투석을 이용한 구리이온의 제거 시 운전인자의 영향 (Effect of Operating Parameters on the Removal Performance of Copper Ion by Electrodialysis)

  • 정효상;이강춘
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.54-60
    • /
    • 2011
  • To evaluate the feasibility of electrodialysis for copper removal from industrial wastewater, the effect of operating parameters on the removal of copper was experimentally estimated. The limiting current density (LCD) linearly increased with the copper concentration and the flow rate. The time when the copper concentration of diluate reaches to 3 mg/L was linearly proportional to initial concentration of diluate, and the concentration of concentrate did not affect the removal rate. Increase in the flow rate gave a positive effect on the removal rate and became insignificant at flow rates greater than 2.4 L/min. The removal rate increased with the applied voltage. From the operation of the electrodialysis module used in this research, the flow rate of 2.4 L/min and the voltage corresponding to the 80~90% of LCD were found be the optimum operating condition for the copper removal from highly concentrated copper solutions.

오존처리수의 전기응집처리 연구 (Study of Wastewater Treatment in the Continuous Electro-Coagulation Plug Flow Reactor after Ozone Treatment)

  • 박영규
    • 환경위생공학
    • /
    • 제16권2호
    • /
    • pp.1-8
    • /
    • 2001
  • The water treatment by electrochemical method was performed to increase the yield of production. Continuous plug flow reactor was operated to treat poultry and domestic wastewaters. Experimental results were compared with experimental results of the wastewater treatment by chemical coagulation, they were increased over 10% in the removal efficiency of COD and the production rate of sludge was reduced by 30%. Ozone utilized to degrade or change the organic chemical structures, which removal efficiency increased to 20% in the electro-coagulation reactor. Economic evaluation was performed to estimate total cost of electro-coagulation reactor in comparison with that of chemical coagulation method. The total cost to treat 1000 ton/day of domestic wastewater was reduced by 50%.

  • PDF