Determination of Major Reduced Sulfur Gases Emitted from Wastes Stored in Environmental Facility Using GC/FPD (GC/FPD를 이용한 환경기초시설 폐기물의 대기중 황계열 악취물질 배출특성에 관한 연구)

  • Lee, Taeyoon;Lee, Jeakeun;Lee, Junki
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.37-43
    • /
    • 2009
  • With the economic development of Korea, sewage treatment facilities and waste food treatment facilities have been steadily increased. These facilities have positive effects such as the conservation of the water resources quality and waste food recycling while they also affect the neighborhood life with severe odor problems. Therefore, it was first collected sludge samples from 5 sewage treatment facilities and 5 waste food treatment facilities where the amounts of waste produced from above sites are relatively immense in Busan and estimate the $H_2S$ emission rates. Then it was selected 1 sample which has the highest emission rate of $H_2S$. Using flux chamber and GC/FPD analyses, it was tried to quantify the emitted amount of sulfonic gas concentration under anoxic condition. The sludge sample obtained from Noksan sewage treatment facility has the highest emission rate of $H_2S$. This sample contained 156.18 mg/kg $H_2S$. The odor compounds were analyzed using GC/FPD and the concentrations were converted to odor quotient. Among odor compounds the ratio of $CH_3SH$ (methylmercaptan) for the total odor quotient was 47.3% and considered to be the main odor compound in the sample.

  • PDF

Membrane Technology for Waste Water Recovery

  • Okazaki, Minoru
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.22-33
    • /
    • 1996
  • With the experience of the 1994 drought, and the shortage of water resources in Japan, it has been re-informed upon us ensure and maintain the stability of water resources. Accordingly, with each plant, a serious appraisal has begun looking at the re-use of waste water. Membrane technology is an important process for waste water recovery. Effluent kom waste water facilities changes the quality of water significantly. The conventional pre-treatment of RO is hard to supply good quality feed water to RO in the waste water recovery system. The microfiltration system as a pre-treatment of RO in the paper overcomes the fouling with the air backwash and is operated in direct flow mode at a low pressure producing a high flux. The paper will focus the waste water recovery using membrane technology and many examples will be given.

  • PDF

Nanowastes treatment in environmental media

  • Kim, Younghun
    • Environmental Analysis Health and Toxicology
    • /
    • v.29
    • /
    • pp.15.1-15.7
    • /
    • 2014
  • Objectives This paper tried to review a recent research trend for the environmental exposure of engineered nanomaterials (ENMs) and its removal efficiency in the nanowaste treatment plants. Methods The studies on the predicted environmental concentrations (PEC) of ENMs obtained by exposure modeling and treatment (or removal) efficiency in nanowaste treatment facilities, such as wastewater treatment plant (WTP) and waste incineration plant (WIP) were investigated. The studies on the landfill of nanowastes also were investigated. Results The Swiss Federal Laboratories for Materials Science and Technology group has led the way in developing methods for estimating ENM production and emissions. The PEC values are available for surface water, wastewater treatment plant effluents, biosolids, sediments, soils, and air. Based on the PEC modeling, the major routes for the environmental exposure of the ENMs were found as WTP effluents/sludge. The ENMs entered in the WTP were 90-99% removed and accumulated in the activated sludge and sludge cake. Additionally, the waste ash released from the WIP contain ENMs. Ultimately, landfills are the likely final destination of the disposed sludge or discarded ENMs products. Conclusions Although the removal efficiency of the ENMs using nanowaste treatment facilities is acceptable, the ENMs were accumulated on the sludge and then finally moved to the landfill. Therefore, the monitoring for the ENMs in the environment where the WTP effluent is discharged or biomass disposed is required to increase our knowledge on the fate and transport of the ENMs and to prevent the unintentional exposure (release) in the environment.

A Case Study on Simplified Assessment Method for Site Selection of the Waste Treatment Facilities in Korea (폐기물 처리시설 입지선정의 효율화 방안에 관한 연구 - 여주군 폐기물 매립지 입지선정 사례를 중심으로 -)

  • Lee, Mu Choon;Koo, Ja Kon;Kim, Ki Cheol;Kwon, Yeon Jeong
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.1
    • /
    • pp.71-79
    • /
    • 1999
  • The comparative evaluation is the most effective method for site selection because the selection of waste treatment facility is to determine the optimum site out of limited candidate sites. This study adopted the ordinal scale evaluation, one of methods of comparative evaluation. The ordinal scale evaluation aims to determine the investigating items referring to the character of sites, to determine the importance factors for investigating items, and to determine the optimum site according to the quantitative evaluation. As a result of this study, the defects of the former reports on the environmental characteristics, such as obscurity of meaning and subjective statement, were reduced by the ordinal scale evaluation which is one of the quantitative evaluation methods. This ordinal scale evaluation method has some valuable advantages, such as, to be able to consider the cost-effect efficiency, to consider the objectiveness and the clearness of the reports on the environmental characteristics. Therefore the reducement of social complications about site selection of the indisposed facilities could be expected by this study.

  • PDF

A Study on Odor Dispersion Prediction of Waste Treatment Facilities Using CFD (CFD를 이용한 쓰레기 처리시설의 악취확산 예측에 관한 연구)

  • Kyung, Seo-Kyung;Kim, Kong-Sook;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.342-349
    • /
    • 2009
  • The purpose of this study is to estimate efficiently an odor dispersion from waste treatment facility for a crematory and a neighborhood facility, then propose planning, a location of an opening or the arrangement of the trees. Hence, offer a comfortable environment for a resident. For this, first the research data about estimating odor dispersion from waste treatment facility and odor are analyzed, then research an ingredient, characteristic, a direct effect for human and a method of measurement. Second, with on-site survey, check odorimetry and the source of odor dispersion, then apply this to the boundary condition of CFD simulation. Third, analyse by the hour for the 2008 standard weather data of Cheon-an, then apply summer data that odor dispersion is active, winter data relatively slow and an annual mean velocity and wind to the simulation. Even if a crematory and neighborhood facility located on south and north from waste treatment facility are at the low rate, the south and north wind will be applied to the simulation. Fourth, with CFD simulation result, predict an odor dispersion, then propose a solution which is considered an odor dispersion, a location of an opening and the arrangement of the trees. Consequently, this study will have an effect on an environment of a resident.

  • PDF

A Study on the Appropriate Management of Specific Hazardous Industrial Waste (특정유해산업폐기물의 적정관리에 관한 연구)

  • 양재윤;김원만;박재주
    • Environmental Analysis Health and Toxicology
    • /
    • v.6 no.1_2
    • /
    • pp.83-93
    • /
    • 1991
  • The specified industrial wastes increased 26% annually during the last 5 years from 1984 to 1988 in Korea, and the special treatment and proper management are required. The effective methods are studied on the process of generation, keeping, transportation, and treatment/disposal for specified industrial wastes and materials. Also, in this paper, the author describes the plans to develop the public disposal facilities and manage specific industrial waste properly in Korea.

  • PDF

Review and Suggestion for Waste Transfer Stations in Seoul (서울시 생활폐기물 적환장 운영실태 분석 및 제언)

  • Yoo, Kee-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.4
    • /
    • pp.21-29
    • /
    • 2016
  • This study was conducted to review Waste Transfer Stations(WTSs) in Seoul, especially focusing on three aspects, main roles, neighbor friendly and regulation compliance, and to draw out recommendation for improvement. The 46 units of all 65 WTSs treated large amount of waste on a day shipping-out schedule, the other 19 WTSs treated small amounts of wastes which were transported after 3~30 days stock. About 57% of WTSs are located in residential or commercial area. Other 57% of WTSs were open without walls. 79% of WTSs were placed alone. Just 17% of WTSs were permitted as environmental infrastructures by urban planning law, and 31% of WTSs were operated by private waste haulers who were permitted by waste management law. Most WTSs in Seoul seemed to go well with on-going policy demand, such as regionalizing waste treatment facilities, expanding waste recycling, and so on. However lots of WTSs did not implement sufficient environmental protection measures, and partly not compliant with regulations related to urban infrastructures. In the future, the issue on sealing facilities and integrating functions of waste management facilities could be considered in order to fit in urban environment.

Investigation on Posssiblility of Composting by Properties Analysis of Organic Sludge Composts (각종 유기성오니의 성상분석에 의한 퇴비화가능성의 검토)

  • Han, E.J.;Choi, H.G.;Lee, J.A.;Kim, K.Y.;Lee, C.K.;Park, K.H.;Phae, C.G.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.1
    • /
    • pp.109-120
    • /
    • 2000
  • In the analysis of the common categories, moisture contents and organic concentrations were not much different according to the types of industry or treatment facilities. When heavy metals contribution of the sludge from domestic and industrial wastewater treatment facilities was analyzed, As, Hg and Cr concentrations were relatively high among 42 standards of the fertilizer law. As concentration war higher in 28 of 42 facilities (67%) than limits of the fertilizer law. Hg concentration was not acceptable in the 21 of 42 facilities (50%). Cr concentration was not acceptable in 9 of 42 facilities (21%). From these results, It is found that As is the most frequently detectable component and contaminant than any other heavy metals in sludges. The data from this experiment was also compared with the guidelines of harmful organics and the rest of heavy metals that are regulated by some of the foreign countries. Be, Se and Mo concentrations were lower than the limits. Among the organics, the average concentration of PCB (10 samples) was 26.2 ppb. The highest concentration was 162.6 ppb in the sludge of the municipal wastewater treatment facilities and the lowest concentration was 2.14 ppb from the skin manufacturing industry. From the leaching analysis of re-manufacturing goods from the sludge, most of them was acceptable on the regulation law but Cr concentration was over the limit.

  • PDF

Development of Composting Technology in Animal Waste Treatment - Review -

  • Haga, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.4
    • /
    • pp.604-606
    • /
    • 1999
  • Solid animal wastes in Japan are treated mainly by composting. The composting process under controlled conditions is able to convert the wastes into high-quality organic fertilizer. Various types of composting facilities with/without forced aeration and turning device are available. Characterization of the maturing process during composting was studied, to improve the quality of compost and to make the degree of maturity. Recycling of animal wastes as compost without any environmental pollution will be closely related to the development of sustainable agriculture with organic fertilizer in Japan.

A Study on an Improvement for Management System of Municipal Sewage Sludge through an investigation of MSS Treatment Facilities (하수오니 처리시설 현황분석을 통한 처리체계 개선 방안 연구)

  • Kim, Young-Koo;Phae, Chae-Gun;Ryu, Don-Sik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.2
    • /
    • pp.121-128
    • /
    • 2006
  • In this study, the existing MSS facilities were investigated for examination the the present condition of MSS treatment system. There are 23 MSS treatment facilities across the country, In total facilities, 6 facilities have economical problems, and 2 facilities were stopped the operation of establishments for technical problems, and most facilities are suffering from environmental problems, for example, odor and waste water. These kinds of problems play a role as obstacle to treat MSS efficiently. Accordingly, to reform current MSS treatment system, a few adequate measures are required. First a Guide line, which is a manual for establishment of MSS treatment facilities efficiently and environmentally friendly, must be offered from the agencies concerned of the Ministry of Environment to local governments. Second, to devise a plan for MSS treatment, Ministry of Environment and all local governments should devise a long-range policy synthetically not fragmentarily and temporarily.

  • PDF