• 제목/요약/키워드: wall-slab joint

검색결과 26건 처리시간 0.023초

탄소섬유와 L형강을 이용한 벽-슬래브 접합부의 보강성능 (Structural Performance of Seismic Resistance Capacity of Carbon Sheet-Angle Retrofitting Method in Wall-Slab Joint)

  • 노공기;박태원;박현수;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.65-68
    • /
    • 2004
  • In the seismical capacity evaluation for RC structure wall-slab joint is very important factor. Because lateral load is resistance element and gravity load resistance element are acted mutually in the wall-slab joint. In this paper, to improve the seismic capacity of the wall-slab joint in the existing wall type apartments experiment which improve and retrofit a seismic capacity by unequal angle bracing and carbon sheet attachment are carried out. These methods are also economic and simple in mitigating seismic hazard, improve earthquake-resistance performance, and reduce risk level of building occupants. From the experimental results, the change of strength, degration of stiffness, and energy dissipation are evaluated. It can be concluded that these methods are effective in improving the seismic performance.

  • PDF

트러서메쉬 보강 하프 슬래브의 구조적 거동에 관한 실험적 연구 (An Experimental Study on Structural Behavior of Half Slab Reinforced by Truss Mesh)

  • 고만영;김용부;박현수;정란
    • 콘크리트학회지
    • /
    • 제7권4호
    • /
    • pp.119-128
    • /
    • 1995
  • 이 연구는 최근 건설공사에서의 인력 및 원가의 절감, 공기의 단축 등을 도모하기 위하여 도입되고 있는 하프슬래브의 실용화를 위한 구조거동을 알아보기 위한 실험적 연구이다. PC 패널의 두께, 트러스메쉬의 형사, 가력하중의 형태를 변수로 총 17개의 시험체를제작하여 PC 패널, 하프슬래브, 하프슬래브-벽체 접합부의 휨성능 실험을 하였다. 실험결과, 부방향 하중을 받는 PC 패널의 휨강도가 설계강도보다 작게 나타났으나 정방향 하중을 받는 PC판넬과 덧침콘크리트의 분리현상이 발견되지 않았으며 휨강도 또한 일체로 타설한 부재와 같은 휨내력을 발현하였다. 따라서, 본 연구에서는동바리를 2.0-2.5m간격으로 설치하고, PC판넬과 덧침콘크리트와의 접합면을 조면처리하고 청결을 유지하면 사용상 문제가 없는 것으로 판단되었다.

리브 보강된 SC구조 벽-바닥 접합부의 거동 및 내력 평가 (Behavior and Strength of Rib Stiffened SC Wall-slab Connection)

  • 박정학
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.349-359
    • /
    • 2014
  • 강판콘크리트(SC)구조 벽-바닥접합부는 표면 강판에 의해 콘크리트가 나뉘게 되며 이 때문에 바닥 단부의 응력 전달기구가 RC구조의 것과 다를 것으로 예상된다. 따라서 본 연구에서는 리브가 부착된 SC구조 벽-바닥 실험체의 거동 및 내력평가를 수행하였다. 리브가 부착된 SC벽바닥 접합부의 접합성능을 확인하기위하여 7가지의 접합부 모형을 제작하고 단조 가력실험을 수행하여 구조내력 및 거동특성을 실험결과분석을 통해 고찰하였다. 제안식의 신뢰성을 확보하기위해 유한요소 해석을 수행하였다. 실험체 변수로는 가력지점, 마찰계수이며 이들의 영향에 대해 검토되었다. 실험체 파괴모드 분석을 통해 접합부 내력을 확인하였다. 제안식은 대부분 보수적인 값으로 확인되었다.

철근격자망을 사용한 슬래브-벽체 접합부의 구조성능 (Structural Performance of RC Slab-Wall Joints Reinforced by Welded Deformed Steel Bar Mats)

  • 박성식;윤영호;이범식
    • 토지주택연구
    • /
    • 제2권1호
    • /
    • pp.61-68
    • /
    • 2011
  • 본 연구는 벽식구조 아파트의 슬래브와 벽체를 철근격자망으로 배근할 경우 접합부의 구조성능을 검증하기 위해 수행되었다. 이를 위해 벽체와 연결된 불연속단의 캔틸레버형 슬래브 시험체를 사용하여 철근격자망 상부근의 정착길이와, 철근격자망의 정착부에 일반 구부림 철근을 사용하여 정착한 경우의 정착방법 및 길이를 변수로 실험을 수행하였다. 결과는 다음과 같다. (1) 슬래브-벽체 외부접합부의 철근망 시공에서 슬래브 철근망은 벽체의 철근 선까지 배근하고 이음길이를 확보한 별도의 철근을 $90^{\circ}$ 표준갈고리로 정착하는 경우, 정착길이와 단면적이 확보되면 강도 발현에 문제가 없는 것으로 나타났다. (2) 슬래브 철근망을 접합부에서 이음할 때 철근망의 철근을 벽체 속으로 매입하면 강도는 더욱 증가한다. 그러나 최고강도에 도달한 이후의 연성은 이음이 없는 것과 동일한 것으로 나타났다. (3) 슬래브-벽체 외부접합부에서 단부 모멘트에 대한 슬래브 하부 압축콘크리트의 파괴시 변형률은 일반 콘크리트 보와 비교할 때 훨씬 큰 것으로 나타났다. 이는 슬래브-벽체 접합부가 $90^{\circ}$를 이루고 있어 이에 따른 구속효과가 있기 때문인 것으로 판단된다.

지하주차장과 아파트 연결 벽체의 균열 원인 분석 및 저감방안 연구 (A Study on the Cause and Reduction of Cracks in the Wall Connecting the Underground Parking Lot and the Apartment)

  • 심학보;박순전
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.161-162
    • /
    • 2020
  • Cracks are caused by drying shrinkage between the upper part of the underground parking lot and the apartment wall. As a result of the investigation, the distance between the apartment and the apartment is more than 45m, and the top slab of the underground parking lot is usually flat when there is not with steps. Therefore, the crack occurs more when the underground parking lot is a PC slab than a RC slab. In this study, the reduction of cracks was conducted by extending the slab, expanding the beam size, increasing the wall thickness, and installing a delay joint on slab. In each case, a finite element analysis was performed to examine the crack reduction method.

  • PDF

SC구조 벽-바닥 접합부의 내력 및 거동 특성 (Behavior and Strength of Wall-Slab Connection in SC Structure)

  • 김형국;김우범;김원기
    • 한국강구조학회 논문집
    • /
    • 제20권2호
    • /
    • pp.347-354
    • /
    • 2008
  • SC 구조는 시공 및 제작성이 우수하여 최근 국내외 원자력 발전소 건설에 적용되고 있는 구조이다. SC 구조의 벽 -바닥 접합부가 갖는 전단력 전달기구를 확인하기 위하여 4개의 실험체에 대하여 실험을 수행하고, 접합부의 거동특성을 분석하였다. 이를 바탕으로 접합부의 전단내력 평가를 위한 해석적 연구를 수행하였다. 그 결과, 실험 결과와 해석결과 간의 근접성을 확인하였고, 접합부의 내력 및 파괴모드를 도출하였다. 그리고 전단플레이트의 두께와 벽면 마찰력의 변화가 접합부 전단내력에 미치는 영향을 파악한 결과, 제안한 접합부 내력식이 보수적인 값을 제시하고 있음을 확인하였다.

슬립폼 공법으로 건설된 벽식 구조의 거동에 관한 연구 (Structural Behavior of Wall-Type Structure with the Application of Slip-Form System)

  • 문정호;이리형
    • 콘크리트학회지
    • /
    • 제7권4호
    • /
    • pp.157-168
    • /
    • 1995
  • Slip-Form시스템을 사용하였을 때 공기단축 및 우수한 품질의 벽체타설이 가능하기 때문에, 그 적용성 및 구조적 거동을 평가하는 연구가 수행되었다. 그러나 슬래브를 벽체와 동시에 타설할 수 없기 때문에 벽체-슬래브 접합부의 주변에 취약점이 생기게 될 가능성이 있으므로, 본 연구는 Slip-Form시스템을 사용한 벽식 구조의 성능을 평가하고, 효과적인 접합부를 개발하는 것을 목적으로 하였다. 이를 위하여 7개의 벽체 실험체와 8개의 벽체-슬래브 접합부 실험체를 제작하여 실험을 실시하였다. 그리고 실험결과들을 설계식 및 이론적인 해석 결과와도 비교하였다. 벽체압축 실험으로부터 그 구조적 거동이 일체식 구조와 유사함을 알 수 있었으며, 벽체-슬래브 접합부 실험으로 부터는 철근연결용 철물이 있는 경우는 제외하고는 좋은 성능을 나타냄을 알 수 있었다. 그러나 외벽에 철근연결용 철물을 사용한 경우에는 벽체의 강도을 검토하여 설계에 반영하여야 함을 알 수 있었다.

CT형강 전단연결재가 적용된 합성형 PHC벽체파일-하부슬래브 연결부 성능에 관한 실험적 연구 (An Experimental Study on Structural Capacity of Joint Between Composite PHC Wall Pile and Bottom Slab with CT Shear Connector)

  • 마호성;원정훈;이종구
    • 한국강구조학회 논문집
    • /
    • 제25권5호
    • /
    • pp.531-541
    • /
    • 2013
  • 본 연구에서는 합성형 PHC 벽체파일의 CT형강 전단연결재가 벽체파일과 하부 슬래브와의 연결부에서 인장력에 저항하는 앵커의 성능을 갖는지 직접 인발실험을 통해 분석하였다. 다양한 실물 크기 실험체들의 파괴형상과 하중-변위 곡선으로부터 CT형강의 인발파괴를 방지하기 위해서는 CT형강 복부 홀에 관통철근을 배치하여 강도를 증가시켜야 함을 알 수 있다. 관통철근이 설치된 다양한 단면의 실험체들을 대상으로 지지점 거리를 변화시켜 파괴형상과 극한강도를 분석한 결과, CT형강의 인발파괴 전에 벽체파일 자체의 콘크리트 인장파괴가 모든 실험체에서 발생하므로 적용된 CT형강 전단연결재는 벽체파일과 하부 슬래브 연결부의 발생 인장력에 대해 충분히 저항할 수 있다.

철근콘크리트 프리캐스트 대형판 접합부의 설계 및 해석 (Design and Analysis on The Connections of RC Precast Large Panel)

  • 박강근
    • 한국공간구조학회논문집
    • /
    • 제6권2호
    • /
    • pp.85-92
    • /
    • 2006
  • 본 연구에서는 철근콘크리트 프리캐스트 대형판의 접합부 설계방법 및 해석방법에 대해서 연구를 수행하였다. 접합부의 설계방법은 수평접합부와 수직접합부의 구조적 거동에 대한 안정성 및 일체성을 확보하기 위한 설계법을 제시하였고, 접합부의 해석은 강체스프링 모델에 의한 탄소성해석을 수행 하였다.

  • PDF

SC구조의 벽-바닥 접합부의 정착강도에 관한 연구 (A Study on the Bond Strength of Wall-Slab Joint of Steel Plate-Concrete Structures)

  • 최경민;김기성;김병국;김원기;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.321-324
    • /
    • 2006
  • An experimental study on the bond strength of wall-slab joint in SC(steel plate-concrete) structure was performed. Six-full scale specimens were tested. Specimens were constructed with key variables, such as, development length, location of the bar and quantity of the shear bar. The experimental results, show that as the development length and quantity of the shear bar increase, the bond strength increases. As the bars is located on the inside the stud bolt, the bond performance was highly increased compared to the bars located out of plane of the stud bolts.

  • PDF