• 제목/요약/키워드: wall-flow

검색결과 2,984건 처리시간 0.03초

원관내 유동에서의 준최적 제어의 평가 (Assessment of Suboptimal Control in Turbulent Pipe Flow)

  • 최정일;;성형진
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.345-352
    • /
    • 2002
  • A suboptimal control law in turbulent pipe flow is derived and tested. Two sensing variables ∂p/∂$\theta$$\_$w/ and ∂v$\_$$\theta$/∂γ│$\_$w/ are applied with two actuations ø$\_$$\theta$/ and ø$\_$γ/. To test the suboptimal control law, direct numerical simulations of turbulent pipe flow at Re$\_$$\tau$/=150 are performed. When the control law is applied, a 13∼23% drag reduction is achieved. The most effective drag reduction is made at the pair of ∂v$\_$$\theta$/∂γ│$\_$w/ and ø$\_$γ/. An impenetrable virtual wall concept is useful for analyzing the near-wall suction and blowing. The virtual wall concept is useful for analyzing the near-wall behavior of the controlled flow. Comparison of the present suboptimal control with that of turbulent channel flow reveals that the curvature effect is insignificant.

분무액적과 벽의 상호작용에 대한 연구 (Study of Spray Droplet/Wall Interaction)

  • 양희천;유홍선;정연태
    • 한국자동차공학회논문집
    • /
    • 제6권4호
    • /
    • pp.86-100
    • /
    • 1998
  • The impingement of the fuel spray on the wall within the combustion chamber in compact high-pressure injection engines and on the intake port wall in port-fuel-inje- ction type engines is unavoidable. It is important to understand the characteristics of impinging spray because it influences on the rate of fuel evaporation and droplet distrib- ution etc. In this study, the numerical study for the characteristics of spray/wall interaction is performed to test the applicability and reliability of spray/wall impingement models. The impingement models used are stick model, reflect model, jet model and Watkins and Park's model. The head of wall-jet eminating radilly outward from the spray impingement site contains a vortex. Small droplets are deflected away from the wall by the stagnation flow field and the gas wall-jet flow. While the larger droplets with correspondingly higher momentum are impinged on the wall surface and them are moved along the wall and are rolled up by wall-jet vortex. Using the Watkins and Park's model the predicted results show the most reasonable trend. The rate of increase of spread and the height of the developing wall-spray is predicted to decrease with increased ambient pressure(gas density).

  • PDF

곡면 벽을 지나는 고아음속 공동 유동에 관한 수치해석적 연구 (Numerical Analysis of the High-Subsonic Cavity Flows over a Curved Wall)

  • 예아란;;김희동
    • 한국추진공학회지
    • /
    • 제20권1호
    • /
    • pp.1-7
    • /
    • 2016
  • 공동 유동에 대한 연구는 유동이 균일하게 유입되는 수평면상에 설치된 공동에 대한 연구가 대부분이나, 곡면 벽상에 설치한 공동 유동에 관한 연구에 대해서는 거의 수행되지 않았다. 본 연구에서는 곡면 벽상에 설치한 공동 유동의 특성을 조사하기 위해 수치계산을 수행하였으며, 곡면의 형상, 곡면의 곡률 반경 그리고 유동의 마하수를 변화시켜 고아음속 유동에서의 공동 유동 특성을 조사하였다. 그 결과 공동 바닥의 압력은 L/R이 증가함에 따라 증가하였으며, 유동의 마하수가 높을수록 그 효과가 증가하였다. 공동 저항은 수평면 벽보다 곡면 벽에서 더 높은 값을 가졌다.

청수현상 추정을 위한 댐 붕괴 흐름의 유체동역학적 특성에 관한 실험적 연구 (Experimental Study on Hydrodynamic Characteristics of Dam Break Flow for Estimation of Green Water Loading)

  • 김형준;김종무;김재홍;정광효;이강남
    • 대한조선학회논문집
    • /
    • 제60권2호
    • /
    • pp.120-134
    • /
    • 2023
  • In this study, hydrodynamic characteristics of dam break flow were investigated by a series of experiments. The experiments were performed in a 2-D rectangular flume with obtaining instantaneous images of dam break flow to capture the free surface elevation, and pressure distributions on vertical wall and bottom of the flume. The initial water depth of the dam break flow was changed into 3 different heights, and the gate opening speed was changed during the experiments to study the effect of the gate speed in the dam break flow. Generation of dam break phenomena could be classified into three stages, i.e., very initial, relatively stable, and wall impact stages. The wall impact stage could be separated into 4 generation phases of wall impinge, run-up, overturning, and touchdown phases based on the deformation of the free surface. The free surface elevation were investigated with various initial water depth and compared with the analytic solutions by Ritter (1892). The pressures acting on the vertical wall and bottom were provided for the whole period of dam break flow varying the initial water depth and gate open speed. The measurement results of the dam break flow was compared with the hydrodynamic characteristics of green water phenomena, and it showed that the dam break flow could overestimate the green water loading based on the estimation suggested by Buchner (2002).

풀 핵비등시 단일 기포 성장에 대한 벽면 과열도의 영향에 관한 연구 (Wall Superheat Effect on Single Bubble Growth During Nucleate Boiling at Saturated Pool)

  • 김정배;이한춘;김무환
    • 대한기계학회논문집B
    • /
    • 제29권5호
    • /
    • pp.633-642
    • /
    • 2005
  • Nucleate pool boiling experiments for R11 under a constant wall temperature condition were carried out. A microscale heater array was used for the heating and the measurement of high temporal and spatial resolution by the Wheatstone bridge circuit. Very sensitive heat flow rate data were obtained by the control for the surface condition with high time resolution. The measured heat flow rate shows a discernable peak at the initial growth stage and reaches an almost constant value. In the thermal growth region, bubble shows a growth proportional to $t^{\frac{1}{5}}$. The bubble growth behavior is analyzed with a dimensionless parameter to compare with the previous results in the same scale. As the wall superheat increases, the departure diameter and the departure time increase, and the waiting time decreases. But the asymptotic growth rate is not affected by the wall superheat change. The effect of the wall superheat is resolved into the suggested growth equation. Dimensionless parameters of time and bubble radius characterize the thermal growth behavior well, irrespective of wall condition. The comparison between the result of this study and the previous results shows a good agreement at the thermal growth region. The quantitative analysis for the heat transfer mechanism is conducted with the measured heat flow rate behavior and the bubble growth behavior. The required heat flow rate for the volume change of the observed bubble is about twice as much as the instantaneous heat flow rate supplied from the wall.

수직벽 화재 자연대류에 의한 난류 경계층 열유동 특성 해석 (ANALYSIS OF TURBULENT BOUNDARY LAYER OF NATURAL CONVECTION CAUSED BY FIRE ALONG VERTICAL WALL)

  • 장용준;김진호;류지민
    • 한국전산유체공학회지
    • /
    • 제21권4호
    • /
    • pp.1-10
    • /
    • 2016
  • The analysis of characteristics of turbulent flow and thermal boundary layer for natural convection caused by fire along vertical wall is performed. The 4m-high vertical copper plate is heated and kept at a uniform surface temperature of $60^{\circ}C$ and the surrounding fluid (air) is kept at $16.5^{\circ}C$. The flow and temperature is solved by large eddy simulation(LES) of FDS code(Ver.6), in which the viscous-sublayer flow is calculated by Werner-Wengle wall function. The whole analyzed domain is assumed as turbulent region to apply wall function even through the laminar flow is transient to the turbulent flow between $10^9$<$Gr_z$<$10^{10}$ in experiments. The various grids from $7{\times}7{\times}128$ to $18{\times}18{\times}128$ are applied to investigate the sensitivity of wall function to $x^+$ value in LES simulation. The mean velocity and temperature profiles in the turbulent boundary layer are compared with experimental data by Tsuji & Nagano and the results from other LES simulation in which the viscous-sublayer flow is directly solved with many grids. The relationship between heat transfer rate($Nu_z$) and $Gr_zPr$ is investigated and calculated heat transfer rates are compared with theoretical equation and experimental data.

Parameter Study of Boiling Model for CFD Simulation of Multiphase-Thermal Flow in a Pipe

  • Chung, Soh-Myung;Seo, Yong-Seok;Jeon, Gyu-Mok;Kim, Jae-Won;Park, Jong-Chun
    • 한국해양공학회지
    • /
    • 제35권1호
    • /
    • pp.50-58
    • /
    • 2021
  • The demand for eco-friendly energy is expected to increase due to the recently strengthened environmental regulations. In particular, the flow inside the pipe used in a cargo handling system (CHS) or fuel gas supply system (FGSS) of hydrogen transport ships and hydrogen-powered ships exhibits a very complex pattern of multiphase-thermal flow, including the boiling phenomenon and high accuracy analysis is required concerning safety. In this study, a feasibility study applying the boiling model was conducted to analyze the multiphase-thermal flow in the pipe considering the phase change. Two types of boiling models were employed and compared to implement the subcooled boiling phenomenon in nucleate boiling numerically. One was the "Rohsenow boiling model", which is the most commonly used one among the VOF (Volume-of-Fluid) boiling models under the Eulerian-Eulerian framework. The other was the "wall boiling model", which is suitable for nucleate boiling among the Eulerian multiphase models. Moreover, a comparative study was conducted by combining the nucleate site density and bubble departure diameter model that could influence the accuracy of the wall boiling model. A comparison of the Rohsenow boiling and the wall boiling models showed that the wall boiling model relatively well represented the process of bubble formation and development, even though more computation time was consumed. Among the combination of models used in the wall boiling model, the simulation results were affected significantly by the bubble departure diameter model, which had a very close relationship with the grid size. The present results are expected to provide useful information for identifying the characteristics of various parameters of the boiling model used in CFD simulations of multiphase-thermalflow, including phase change and selecting the appropriate parameters.

축류홴 익단누설와류의 수치적 해석 (Numerical Analysis of a Tip Leakage Vortex in an Axial Flow Fan)

  • 장춘만;김광용
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.36-44
    • /
    • 2004
  • Three-dimensional vortical flow and separated flow topology near the casing wall in an axial flow fan having two different tip clearances have been investigated by a Reynolds-averaged Navier-Stokes (RANS) flow simulation. The simulation shows that the tip leakage vortex formed close to the leading edge of the blade tip on suction side grows in the streamwise direction. On the casing wall, a separation line is formed upstream of the leakage vortex center due to the interference between the leakage vortex and main flow. The reverse flow is observed between the separation line and the attachment line generated downstream of the trailing edge, and increased with enlarging tip clearance. The patterns of a leakage velocity vector including a leakage flow rate are also analyzed according to two tip clearances. It is noted that the understanding of the distribution of a limiting streamline on the casing wall is very important to grasp the characteristics of the vortical flow in the axial flow fan.

원형 실린더 주위의 공기로 국소 대류 열전달에 대한 열전도의 영향 (The effect of wall heat conduction on local convection heat transfer from a cylinder in cross flow of air)

  • 이승홍;이억수
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.440-448
    • /
    • 1998
  • This paper considers the influence of circumferential wall heat conduction for the case of forced convection around a circular cylinder in cross flow of air. Keeping uniform heat generation from the inner surface of the cylinder in radial direction, heat is transferred by wall conduction in the circumferential direction due to the asymmetric nature of the temperature distribution of the cylinder and by convection around the perimeter of the cylinder. The wall conduction depends on conductivity of the cylinder and size of the cylinder radius and thickness and affects the local convective heat transfer rate significantly for geometrically similar surfaces and flow conditions. A nondimensional conjugation parameter K. (=k$_t$R/k$_w$b) has been used to characterize the effect of the circumferntial wall heat conduction. The small values of conjugation parameter K are found to be associated with large effect of wall conduction on the local convective heat transfer rate.

  • PDF

과냉비등류에 있어서 동블록을 이용한 과도적 냉각실험 (Transient cooling experiments with a cooper block in a subcooled flow boiling system)

  • 정대인;김경근;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.72-79
    • /
    • 1987
  • When the wall temperature is very high, a stable vapor film covers the heat transfer surface. The vapor film creates a strong thermal resistance when heat is transferred to the liquid though it. This phenomenon, called "film boiling" is very important in the heat treatment of metals, the design of cryogenic heat exchangers, and the emergency cooling of nuclear reactors. In the practical engineering problems of the transient cooling process of a high temperature wall, the wall temperature history, the variation of the heat transfer coefficients, and the wall superheat at the rewetting points, are the main areas of concern. These three areas are influenced in a complex fashion such factors as the initial wall temperature, the physical properties of both the wall and the coolant, the fluid temperature, and the flow state. Therefore many kinds of specialized experiments are necessary in the creation of precise thermal design. The object of this study is to investigate the heat transfer characteristics in the transient cooling process of a high temperature wall. The slow transient cooling experiment was carried out with a copper block of high thermal capacity. The block was 240 mm high and 79 mm O.D.. The coolant flowed throuogh the center of a 10 mm diameter channel in the copper block. In the copper block, three sheathed thermocouples were placed in a line perpendicular to the flow. These thermocouples were used to take measurements of the temperature histories of the copper block.

  • PDF