• 제목/요약/키워드: wall-floor joint

검색결과 13건 처리시간 0.086초

Thermal Analysis of Wall/Floor Intersections in Building Envelope

  • Ihm, Pyeongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.97-107
    • /
    • 2004
  • Wall/floor intersection is important parts of a building envelope system. These intersections can be sources of thermal bridging effects and/or moisture condensation problems. This paper provides a detailed analysis of the thermal performance of wall/floor intersection. In particular, two-dimensional steady-state and transient solutions of the heat conduction within the wall/floor joint are presented. Various insulation configurations are considered to determine the magnitude of heat transfer increase due to wall/floor joint construction.

Development and Structural Assessment of Joints of Permanent Uni-Wall System and Floor Systems in Substructure

  • Chun, Sung-Chul;Kim, Seung-Hun;Noh, Sam-Young;Kim, Kap-Soo;Han, Byum-Seok
    • 한국건축시공학회지
    • /
    • 제12권2호
    • /
    • pp.230-242
    • /
    • 2012
  • Recently the Permanent Uni-wall System (PUS) has been developed which improved the disadvantage of the Cast-In-Place Concrete Pile (CIP) and could be used as permanent retaining wall. In this study, joints between PUS and floor systems were developed. From analyses of the characteristics of design and construction of PUS, shear friction reinforcements with couplers were adopted for shear design of the joints. Twelve types of joints were developed which were classified according to the types of floor structures, wale, and piles of PUS. Two typical joints were tested and the joints showed satisfactory behaviors on the points of shear strength, stiffness, and serviceability. Especially the shear strengths were much higher than the design strengths due to the shear keys which were by-products in splicing shear reinforcements. However, the shear strength of the joint is recommended to be designed by only shear friction reinforcement because shear key is not reliable and too brittle.

내표면 온도차 비율(TDRi) 분석을 통한 현대 신한옥 외벽 모서리 부위 단열성능 평가 (Thermal Performance Evaluation at corners of the External wall of Modern New Han-oks using Temperature Difference Ratio inside)

  • 이주엽;송민정;이태강;김선우;천득염
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.103-112
    • /
    • 2016
  • Recently, many New Han-oks have been constructing in all over the country to popularize as a type of green house. But, achievement of thermal performance of external wall is still the very important issue to become popular. Purpose: The purpose of this study is to verify the thermal performance level of modern New Han-ok through Temperature Difference Ratio inside(TDRi) analysis at corners of the external wall in Han-ok. Method: To achieve this goal, measurements were carried out in 12 Han-oks(experimental mock-up(1), exhibition Han-ok(1), happy village Han-oks(10)) by taking a infra-red thermography using thermal video system. Following are analysis items about connection joint between wall and wood columns of external wall conditions; the part between external wall and external wall(2D), external wall and ceiling(or floor)(2D), 2 external walls and ceiling(or floor)(3D) and so on. Result: It was analyzed that the probability of condensation at most of connection joint appear high and TDRi of 3D corners is higher than that of 2D corners in general. It means that the development of construction techniques about connection joint between wood columns and external wall is still required. The results of this study may be used to improve the construction technology of new Han-ok and as a basis for the specifying the desired thermal comfort environment of dwelling.

경골목조주택의 벽체-바닥체 못결합부의 감쇠비에 관한 연구 (Studies on Damping Ratio of Nailed Joint Connecting Wall to Floor in Light Frame House)

  • 김광모;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제24권3호
    • /
    • pp.65-71
    • /
    • 1996
  • In the design of wood structures, the consideration of the dynamic load effect has been increased. Generally, damping ratio is presented as the method of considering dynamic load effect. So, the relationship between joint type and damping ratio was investigated. It has been known that the joint extremely damp the dynamic load in wood structures. Static test was performed to determine the effects of nail size and friction area on joint strength and stiffness. Joint strength and stiffness were increased with nail size. However, the static properties of joint was not affected by friction area. Cyclic test was performed to determine the effects of nail size, friction area and load magnitude on damping ratio, Damping ratio was affected by all factors. Increasing the width of the bottom plate was suggested as the most adequate method to increase the damping ratio without the reduction of the static properties of the structures.

  • PDF

외부치장적벽돌 벽체에 대한 콘크리트 보강브라켓의 보강효과에 관한 연구 (A Study on the Strengthening effect of Concrete Reinforcement Bracket on the External Clay Brick Wall)

  • 김선우;김양중
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.117-118
    • /
    • 2020
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware (connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. The purpose of this study is to provide numerical information on the reinforcement design by experimentally studying the structural performance of concrete reinforcement brackets that reinforce the vertical load of the exterior wall.

  • PDF

국내 PC 아파트 접합부 누수 방지를 위한 마감상세 분석 (Analysis of finishing details to Prevent leakage of PC Apartment Joints in Korea)

  • 김태호;고효진
    • 한국공간구조학회논문집
    • /
    • 제21권4호
    • /
    • pp.81-89
    • /
    • 2021
  • Recently, interest in OSC(Off Site Construction) is increasing due to the trend of a decrease in skilled workers and an increase in labor costs. In this regard, PC(Precast Concrete) is being reviewed for apartments, the most common type of housing in Korea. As the biggest concern for PC apartment houses, civil complaints such as inter-floor noise and leakage were presented. In this study, the details of the joints were reviewed based on the past cases of PC apartments, and the details of the recently constructed or planned PC apartments were investigated. Through this, the leakage path in the past was analyzed through the existing research literature and data. And wall type RC and PC apartment joint leakage test was performed and we found the needs for a detail of waterproof steps, sealant. Also, joint details were investigated for a rahmen type apartment housing under construction. At last, A discussion was conducted on the direction for a detailed proposal of an improved joint in the future.

제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 - (Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment -)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.86-94
    • /
    • 2018
  • 제천 스포츠센터 화재로 29명이 사망하고 40명이 부상을 입었다. 이 논문에서는 스포츠센터 화재 사례에 대해 다수 사상자가 발생한 요인을 분석하기 위해 저자의 화재조사 결과를 토대로 건물과 설비의 구조적인 요인을 분석하고 있다. 건물과 설비의 구조적인 요인은 필로티 구조의 주차장, 필로티 주차장과 로비 사이 방화구획 미비, 필로티 주차장에 스프링클러설비 미설치, 1층 주계단에 방화문 미설치, 옥상에 소화수조 미설치, 2층 주출입구에 벽체 매립형 방화문 설치, EPS실 및 배관 피트 층별 방화구획 부실, 배수배관 연결부의 누수, 화물용 승강기의 승강로와 실내에 면하는 벽체에 합판 설치, 폐쇄형 옥상구조로 개조, 주차장 반자 안쪽 천장에 스티로폼 단열재 부착, 2층 여탕 무창층 강화유리 구조, 드라이비트 외벽으로 분석하였다.

지진에 의한 원전 보조건물 전단벽의동적 응답 특성 추정 (Seismic Response Characterization of Shear Wall in Auxiliary Building of Nuclear Power Plant)

  • 모터 라만;타미나 나하르;백건휘;김두기
    • 한국지진공학회논문집
    • /
    • 제25권3호
    • /
    • pp.93-102
    • /
    • 2021
  • The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.

건축물에너지 효율을 위한 조적조 열교 차단 브라켓의 성능 평가 연구 (A Study on Performance Evaluation of Masonry Thermal Bridge Blocking Brackets for Building Energy Efficiency)

  • 김웅회;김형규;이태규;이재현;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.175-176
    • /
    • 2023
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware(connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. As a result of the evaluation, it was confirmed that the performance was improved compared to the existing bracket, and we plan to carry out a real-life test and long-term performance review of the building using the bracket in the future.

  • PDF

목조건축물 구조부재의 열전도율에 따른 건물외피의 단열 성능 (Thermal Performance of Wooden Building Envelope by Thermal Conductivity of Structural Members)

  • 김석환;유슬기;서정기;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권6호
    • /
    • pp.515-527
    • /
    • 2013
  • 국내에서 주로 사용되고 있는 건물에너지 성능평가 시뮬레이션 마다 상이한 재료의 열전도율로 평가 되고 있음이 파악되었다. 시뮬레이션을 통한 정확한 건물에너지부하를 평가하기 위하여, 각 시뮬레이션에서 목조건축물의 스터드로 사용되고 있는 목재의 열전도율을 확인하고, 이에 따른 벽체의 열관류율과 부재 접합부위에서의 선형열교 차이를 연구하였다. 각 시뮬레이션은 동일 수종에 대해 상이한 열전도율을 채택 후, 각 시뮬레이션에서 추출한 열전도율 간의 차이가 가장 상이한 소나무의 열전도율을 스터드에 적용하였다. 시뮬레이션 간 지붕, 벽체, 지면 슬래브의 열관류율 중 최대오차는 $0.023W/m^2{\cdot}K$이었으며, 지붕의 서까래 접합부, 지붕-벽체 접합부, 지면슬래브-벽체 접합부 중 최대 선형열교 오차는 $0.025W/m{\cdot}K$이었다. 또한, HEAT2 정상상태전열해석 프로그램을 활용하여 선형열교 및 벽체의 온도변화에 대한 전열해석 이미지를 분석하였다. 구조체에 온도 분포를 선으로 표시하여 단열이 부족한 곳에서는 온도선이 급격하게 변하는 것이 확인되었고, 온도선이 급격하게 변하는 부위에서는 다른 곳보다 온도가 낮으며, 다른 구조체 부분보다 더 많은 열류가 손실됨이 확인되었다.