• 제목/요약/키워드: volumetric measurements

검색결과 122건 처리시간 0.03초

Identification of Green Alga Chlorella vulgaris Isolated from Freshwater and Improvement Biodiesel Productivity via UV Irradiation

  • Gomaa, Mohamed A.;Refaat, Mohamed H.;Salim, Tamer M.;El-Sayed, Abo El-Khair B.;Bekhit, Makhlouf M.
    • 한국미생물·생명공학회지
    • /
    • 제47권3호
    • /
    • pp.381-389
    • /
    • 2019
  • Chlorella vulgaris was isolated from the Nile River, Qalubia Governorate, Egypt, for possible use in biodiesel production. BG-II nutrient growth media was used for isolation and laboratory growth. Identification was performed via 18S rRNA gene amplification, followed by sequencing. The alga was exposed to UV-C (254 nm) for 15, 30, and 45 s to improve dry weight accumulation and to increase the oil production. Daily measurements of dry weight ($g{\cdot}l^{-1}$) were performed; oil content and volumetric lipid productivity were also determined. UV-C exposure led to an increase in the volumetric lipid productivity by 27, 27.3, and $32.4mg{\cdot}l^{-1}{\cdot}d^{-1}$ with 15, 30, and 45 s, respectively, as compared with the control, which resulted in $18mg{\cdot}l^{-1}{\cdot}d^{-1}$. Of the examined mutants, the one with the highest productivity was re-irradiated by UV-C (254 nm) for 15, 30, 45, and 60 s. For 15 s of exposure time, the oil content increased to 34%, while it was 31% at 30 s; further, it decreased to 22% at 45 and 60 s exposures. The fatty acid methyl ester profile was 82.22% in the first mutant at 45 s, compared with the wild strain that contained a total of 66.01% of FAs. Furthermore, the highest levels of polyunsaturated fatty acid methyl ester were observed in the mutant exposed for 45 s, and it reached 11.41%, which reduced the cetane number to 71.3.

Cone-beam CT를 이용한 제II급 부정교합 아동의 상기도 형태에 관한 3차원적 연구 (Three dimensional analysis of the upper airway and facial morphology in children with Class II malocclusion using cone-beam computed tomography)

  • 홍지숙;김대성;오경민;김윤지;이규홍;박양호
    • 대한치과교정학회지
    • /
    • 제40권3호
    • /
    • pp.134-144
    • /
    • 2010
  • 성장기 아동의 상기도 협착은 두개안면 성장에 영향을 미칠 수 있다. 본 연구는 3차원 cone-beam computed tomography (CBCT)를 이용하여 제II급 부정교합 아동의 상기도 부피 및 단면적 계측치와 측모두부계측치를 비교하여 상기도와 안면 형태와의 연관성을 알아보고자 하였다. 37명의 아동(남자 17명, 여자 20명, 평균 연령 11.02세)의 CBCT를 촬영하였다. 연구 결과, 상기도의 PNS-posterior plane에서의 단면적($S_{PP}$)은 제II급 부정교합군에서 유의하게 작았다 (p < 0.05). 상기도 부피 계측치는 제II급 부정교합군에서 제I급 부정교합군보다 작았으나, 두 군 간 통계적으로 유의한 차이는 없었다. 제II급 부정교합군은 후안모고경(PFH), mandibular body length (p < 0.05), Pog to Nperp (p < 0.01)에서 제I급 부정교합군보다 유의하게 작은 값을 보였고, FMA (p < 0.05), ANB, facial convexity (p < 0.01)는 유의하게 큰 값을 보였다. 제II급 부정교합군의 PNS 전방의 상기도 부피($W_N$)는 ANB difference 각도와 음의 상관관계를 보였다 (p < 0.05). 제II급 부정교합 아동은 상대적으로 좁은 상기도 부피를 가지며 이에 따른 감소 된 후안모고경(PFH)과 하악골의 divergent한 안면 성장 양상을 보였다.

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.

강우재현 모형실험과 SWCC Cell 실험에 의한 화강암질 풍화토의 함수특성곡선 (Soil Water Characteristic Curve of the Weathered Granite Soil through Simulated Rainfall System and SWCC Cell Test)

  • 기완서;김선학
    • 지질공학
    • /
    • 제18권4호
    • /
    • pp.523-535
    • /
    • 2008
  • 강우재현장치를 제작하고, 강우 및 사면조건에 따라 강우재현 모형실험과 함수특성곡선실험(SWCC Cell Test)을 실시하여 불포화 특성에 관해 연구하였다. 그 결과를 이용하여 강우에 따른 침투거동 특성과 함수특성곡선 모델들의 불포화된 화강암질 풍화토에 대한 적용을 검토하였다. 강우재현 모형실험의 습윤과정(강우재현)과 건조과정(방치)에서 계측된 체적함수비와 모관흡인력을 비교한 결과 체적함수비는 $2{\sim}5%$, 모관흡인력은 $3{\sim}10\;kPa$ 정도 값의 차이를 보여 이력현상을 확인 할 수 있었다. 또한, 모관흡인력의 값이 체적함수비의 값에 비해 상대적으로 큰 차이를 보여 모관흡인력에 이력거동이 더 큼을 확인할 수 있었다. 강우재현 모형실험과 함수특성곡선실험에서 얻은 결과로부터 구한 함수특성곡선을 비교하면, 습윤과정과 건조과정에서 두 방법 모두 근접한 함수특성곡선을 얻을 수 있었으나, 두 방법 모두 습윤과정과 건조과정에서의 결과는 차이가 있었다. 이로써 불포화토의 특성을 고려한 보다 합리적인 설계나 안정검토에 함수특성곡선을 적용시킬 때에는 습윤과정에서는 습윤과정 함수특성곡선을 건조과정에서는 건조과정 함수특성곡선을 적용하는 것이 합당할 것으로 여겨진다.

Tc-99m DMSA SPECT for Follow-Up of Non-Operative Treatments in Renal Injuries: A Prospective Single-Center Study

  • Sang-Geon Cho;Ki Seong Park;Jahae Kim;Jang Bae Moon;Ho-Chun Song;Taek Won Kang;Seong Hyeon Yu
    • Korean Journal of Radiology
    • /
    • 제24권10호
    • /
    • pp.1017-1027
    • /
    • 2023
  • Objective: The assessment of cortical integrity following renal injuries with planar Tc-99m dimercaptosuccinic acid (DMSA) scintigraphy depends on measuring relatively decreased cortical uptake (i.e., split renal function [SRF]). We analyzed the additive values of the volumetric and quantitative analyses of the residual cortical integrity using single-photon emission computed tomography (SPECT) compared to the planar scintigraphy. Materials and Methods: This prospective study included 47 patients (male:female, 32:15; age, 47 ± 22 years) who had non-operatively managed renal injuries and underwent DMSA planar and SPECT imaging 3-6 months after the index injury. In addition to planar SRF, SPECT SRF, cortical volume, and absolute cortical uptake were measured for the injured kidney and both kidneys together. The correlations of planar SRF with SPECT SRF and those of SRF with volumetric/quantitative parameters obtained with SPECT were analyzed. The association of SPECT parameters with renal function, grades of renal injuries, and the risk of renal failure was also analyzed. Results: SPECT SRF was significantly lower than planar SRF, with particularly higher biases in severe renal injuries. Planar and SPECT SRF (dichotomized with a cutoff of 45%) showed 19%-36% of discrepancies with volumetric and quantitative DMSA indices (when dichotomized as either high or low). Absolute cortical uptake of the injured kidney best correlated with glomerular filtration rate (GFR) at follow-up (ρ = 0.687, P < 0.001) with significant stepwise decreases by GFR strata (90 and 60 mL/min/1.73 m2). Total renal cortical uptake was significantly lower in patients with moderate-to-high risk of renal failure than those with low risk. However, SRF did not reflect GFR decrease below 60 mL/min/1.73 m2 or the risk of renal failure, regardless of planar or SPECT (count- or volume-based SRF) imaging. Conclusion: Quantitative measurements of renal cortical integrity assessed with DMSA SPECT can provide more clinically relevant and comprehensive information than planar imaging or SRF alone.

Change of the airway space in mandibular prognathism after bimaxillary surgery involving maxillary posterior impaction

  • Lee, Woo-Young;Park, Young-Wook;Kwon, Kwang-Jun;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.23.1-23.7
    • /
    • 2016
  • Background: The purpose of this retrospective study was to develop a two- and three-dimensional analysis of the airway using cone-beam computed tomography (CBCT) and to determine whether the airway space would be changed in mandibular prognathism after bimaxillary surgery involving maxillary posterior impaction. Methods: Patients requiring orthognathic surgery from 2012 to 2014 were recruited for this study. CBCT scans were obtained at three points: preoperatively (T0), immediate postoperatively (T1), and after 6 months postoperatively (T2). The nasopharynx, oropharynx, and hypopharynx were measured on the CBCT scan for each patient in a repeatable manner. With the midsagittal plane, linear measurements in the middle of each were obtained. For the CBCT, volumetric measurements of each and total airway were obtained. Results: A total of 22 consecutive patients (11 men and 11 women) were included in the present study. The total volume was significantly reduced (p < .001). However, the change of the diameter and volume of the nasopharynx was not statistically significant (p = .160, p = .137, respectively). In the oropharynx, the change of both the diameter and volume showed statistical significance between preoperatively and immediate postoperatively (p < .001, p = .001, respectively) and also preoperatively and after 6 months postoperatively (p = .001, p = .010, respectively). In the hypopharynx, the change of both the diameter and volume showed statistical significance between preoperatively and immediate postoperatively (p = .001, p < .001, respectively) and also preoperatively and after 6 months postoperatively (p = .001, p < .001, respectively). Conclusions: The bimaxillary surgery involving maxillary posterior impaction can reduce the volume of airway in the patients of mandibular prognathism. Although total airway volume was reduced significantly, the changes in the volume and diameter of the nasopharynx were not statistically significant. The maxillary posterior impaction affects on the nasopharyngeal airway minimally.

머시닝센터의 다축오차 평가 방법 (Evaluation Method of the Multi-axis Errors for Machining Centers)

  • 황주호;심종엽;고태조
    • 한국정밀공학회지
    • /
    • 제28권8호
    • /
    • pp.904-914
    • /
    • 2011
  • The volumetric errors of CNC machining centers are determined by 21 errors, including 3 linear errors, 6 straightness errors, 3 perpendicular errors, 9 angular errors and non-rigid body errors of the machine tool. It is very time consuming and hard to measure all of these errors in which laser interferometer and other parts are used directly. Hence, as many as 21 separate setups and measurements are needed for the linear, straightness, angular and perpendicular errors. In case of the 5-axis machining centers, two more rotary tables are used. It can make 35 error sources of the movement. Therefore, the measured errors of multi movements of the 5-axis tables are very complicated, even if the relative measured errors are measured. This paper describes the methods, those analyze the error sources of the machining centers. Those are based on shifted diagonal measurements method (SDM), R-test and Double ball bar. In case, the angular errors of machine are small enough comparing with others, twelve errors including three linear position errors, six straightness errors and three perpendicular errors can be calculated by using SDM. To confirm the proposed method, SDM was applied to measuring 3 axes of machine tools and compared with directly measurement of each errors. In addition, the methods for measuring relative errors of multi-axis analysis methods using R-test and Double Ball Bar are introduced in this paper.

One Step Measurements of hippocampal Pure Volumes from MRI Data Using an Ensemble Model of 3-D Convolutional Neural Network

  • Basher, Abol;Ahmed, Samsuddin;Jung, Ho Yub
    • 스마트미디어저널
    • /
    • 제9권2호
    • /
    • pp.22-32
    • /
    • 2020
  • The hippocampal volume atrophy is known to be linked with neuro-degenerative disorders and it is also one of the most important early biomarkers for Alzheimer's disease detection. The measurements of hippocampal pure volumes from Magnetic Resonance Imaging (MRI) is a crucial task and state-of-the-art methods require a large amount of time. In addition, the structural brain development is investigated using MRI data, where brain morphometry (e.g. cortical thickness, volume, surface area etc.) study is one of the significant parts of the analysis. In this study, we have proposed a patch-based ensemble model of 3-D convolutional neural network (CNN) to measure the hippocampal pure volume from MRI data. The 3-D patches were extracted from the volumetric MRI scans to train the proposed 3-D CNN models. The trained models are used to construct the ensemble 3-D CNN model and the aggregated model predicts the pure volume in one-step in the test phase. Our approach takes only 5 seconds to estimate the volumes from an MRI scan. The average errors for the proposed ensemble 3-D CNN model are 11.7±8.8 (error%±STD) and 12.5±12.8 (error%±STD) for the left and right hippocampi of 65 test MRI scans, respectively. The quantitative study on the predicted volumes over the ground truth volumes shows that the proposed approach can be used as a proxy.

인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향 (Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom)

  • 왕지환;이희천
    • 한국임상수의학회지
    • /
    • 제31권6호
    • /
    • pp.495-501
    • /
    • 2014
  • 본 연구는 다양한 전산화단층촬영기기와 촬영 프로토콜의 차이에 따른 모형물의 부피와 Hounsfield unit (HU) 수치의 차이를 평가하고 이 후 전산화단층촬영술을 이용하여 결석의 부피와 HU 수치를 포함한 다양한 인자들을 평가하고 이 중 체외충격파쇄석술에 의한 결석의 분쇄를 예측할 수 있는 인자를 찾고자 하였다. 다양한 직경의 100 HU 인공종양 5개를 (직경 3.0-12.0 mm) 이용하여 모형물을 만들었으며, 이 모형물의 부피와 HU 수치를 Siemens사의 2채널, GE사의 4채널과 64채널, 그리고 Philips사의 64채널 전산화단층촬영기기를 사용하여 평가하였다. 또한 각각의 전산화단층촬영기기에서 동일한 조건으로 collimation만 thin collimation과 thick collimation으로 변화를 주어 모형물을 촬영한 후 모형물의 부피와 HU 수치를 평가하였다. 평가자간 (inter-observer) 재현성을 평가하기 위해 3명의 수의영상의학 전공의가 연구에 참여하였으며 이중 한 명의 수의사가 평가자내 (intra-observer) 재현성을 평가하기 위해 모형물의 부피와 HU 수치를 2주 간격으로 총 3번 측정하였다. 부피의 평가자간 재현성과 평가자내 재현성은 k=0.9994, k=0.9969로 아주 우수하였으며, HU 수치의 평가자간 재현성과 평가자내 재현성 역시 k=0.9984, k=0.9655로 아주 우수하였다. 다양한 전산화단층촬영기기와 collimation 차이에 따른 부피와 HU 수치의 차이는 모두 통계학적으로 유의적인 차이를 나타내지 않았다. 그러나 부피의 경우 collimation이 얇을수록 부피의 정확도가 증가하는 경향을 보였다. 본 연구 결과를 토대로 향후 진행될 결석의 부피 및 HU 수치의 평가 시 전산화단층촬영기기의 차이에 따른 영향을 받지 않으리라 판단되어 Siemens사의 2채널 전산화단층촬영기기만을 사용하였으며, 비록 통계학적으로 유의적인 차이는 없었지만 부피의 정확도를 더 높이기 위하여 얇은 collimation을 사용하였다.

2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구 (A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters)

  • 최종오;이완규;임기원
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.