• Title/Summary/Keyword: volumetric loading rate

Search Result 68, Processing Time 0.023 seconds

Nitrogen removal characteristics of pigment wastewater using PAC-A/O process (PAC-A/O 공정을 이용한 안료폐수의 질소 제거 특성)

  • Jeong, Jongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.19-25
    • /
    • 2018
  • The objectives of this study were to evaluate the removal characteristics of total nitrogen, the influence factor of denitrification and the optimum operating condition in the pigment wastewater treatment using PAC-A/O process. The operating conditions of PAC-A/O process were mean BOD volumetric loading $0.86kgBOD/m^3/day$, mean F/M ratio 0.072~0.13 kgBOD/kgMLVSS/day and mean C/N ratio 3.47, respectively. The conditions of anoxic process in the field plant test were mean pH 8.3~8.7 and mean temperature $34.1{\sim}44.0^{\circ}C$. The ORP bending point knee was eventually appeared in the ORP -107 mV and $NO_3{^-}-N$ removal efficiency was increased according to the ORP decrease. In the ORP -107 mV below condition, the removal efficiency of T-N and $NO_3{^-}-N$ was 92.3~95.0% and 98.5~99.7%. Denitrification rate was calculated to be 1.581~1.791 mg $NO_3{^-}-N/gMLSS/hr$. The experimental results showed that the ORP control in the PAC-A/O process could be an effective method for treatment of pigment wastewater.

Applicability of the lenten's Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant (석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성)

  • Lee, Kyu-Hoon;Kim, Mi-Hwa;Park, Tae-Joo
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.115-115
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton''s reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

Applicability of the lenten류s Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant (석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성)

  • Lee, Kyu-Hoon;Kim, Mi-Hwa;Park, Tae-Joo
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.501-508
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton's reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

  • PDF

Nitrogen Removal from Wastewater by a Multi-stage Bio-reactor (다단 생물반응기에 의한 질소제거)

  • 최규철;정일현
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.91-103
    • /
    • 1998
  • Design data for COD and nitrogen removal from wastewater were collected from Pilot's Multi-stage Bio-reactor. Hyraulic conditions and pollutant loadings were varied in order to optimize the biological and operational parameters. Pilot's experimental results summarize as followings. 1. T-N removal efficiency in the organic volumetric loading 0.2 kgCOD/m$^{3}$·d was obtained as maxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.. 2. Nitrification reaction was shown as maxium in the SCOD$_{cr}$/NH$^{+}$-N ratio of 6.5 and in more ratio than this it was decreased. Denitrification rate was the maxium as 85% in more than 7.5 of SCOD$_{cr}$/NO$_{x}$-N ratio and in the ratio over this ratio it becomes constant. 3. By utilizing an applied new model of Stover-Kincannon from Monod's kinetic model, concentration of T-N in the effluent according to flow quanity in the influent was estimated as 8.74 and -67.5 respectively. The formula for estimating T-N concentration of effluent was obtained like this: N$_e$=N$_0$(1- $\frac{8.74}{(QN$_0$/A)-67.05}$)

  • PDF

Influence factors and Efficiencies Characteristics for Treatment of Wastewater Containing Phenol (Phenol 함유폐수의 처리를 위한 영향인자와 성능특성)

  • Kang, Sun-Tae;Kim, Jeong-Mog
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.119-126
    • /
    • 1996
  • Influence factors and efficiency characteristics for treatment of wastewater containing phenol were studied with using Pseudomonas sp. B3. It took 130 hours to remove phenol, when only activated sludge of terminal disposal palnt of sewage was innoculated in batch culture, but it was required just 36 hours, when bacteria degrading phenol and activated sludge were simultaneously innoculated. If only phenol an carbon source was used, it necessary 36 hours for biodegradation of phenol, while glucose was added to medium, it took 73 hours. It was revealed as excellent effluent and SVI, when the F/M ratio, COD and phenol concentration were 53mg/l and 1.2mg/l, respectively, and optimum F/M ratio was revealed 0.31. The reactor were seriously shocked as reducing hydraulic retention time at constant phenol concentration more than increasing phenol concentration at constant hydraulic retention time, when volumetric loading rate was increased to $0.8kg\;phenol/m^3{\codt}d$ from $1.6kg\;phenol/m^3{\codt}d$. And also the effluent phenol concentration was 34mg/l after starting 12 hours of shocking and reactor was recovered as steady state after 65 hours of changing in the former test. Although the effluent phenol concentration was maximum value with 12mg/l after starting 20 hours of shocking and reactor was recovered as steady state after 54 hours of changing in the later test.

  • PDF

DETAILED EXAMINATION OF INVERSE-ANALYSIS PARAMETERS FOR PARTICLE TRAPPING IN SINGLE CHANNEL DIESEL PARTICULATE FILTER

  • Jung, S.C.;Park, J.S.;Yoon, W.S.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.165-177
    • /
    • 2007
  • Predictions of diesel particulate filtration are typically made by modeling of a particle collection, and providing particle trapping levels in terms of a pressure drop. In the present study, a series of single channel diesel particulate filter (DPF) experiments are conducted, the pressure traces are inversely analyzed and essential filtration parameters are deducted for model closure. A DPF filtration model is formulated with a non-linear description of soot cake regression. Dependence of soot cake porosity, packing density, permeability, and soot density in filter walls on convective-diffusive particle transportation is examined. Sensitivity analysis was conducted on model parameters, relevant to the mode of transition. Soot cake porosity and soot packing density show low degrees of dispersion with respect to the Peclet number and have asymptotes at 0.97 and $70\;kg/m^3$, respectively, at high Peclet number. Soot density in the filter wall, which is inversely proportional to filter wall Peclet number, controls the filtration mode transition but exerts no influence on termination pressure drop. The percolation constant greatly alters the extent of pressure drop, but is insensitive to volumetric flow rate or temperature of exhaust gas at fixed operation mode.

Treatment of Ethylene Glycol in Polyester Weight Loss Wastewater(I) - Reaction Characteristics - (Polyester감량폐수 중에 존재하는 Ethylene Glycol의 처리(I) - 반응 특성 -)

  • Kim, Jeong-Mog;Huh, Man-Woo;Han, Myung-Ho
    • Textile Coloration and Finishing
    • /
    • v.8 no.5
    • /
    • pp.84-89
    • /
    • 1996
  • This study carried out batch and continuous experiments using calcium hydroxide as neutralization agent and immobilization media for removing the ethylene glycol in the pretreated polyester weight loss wastewater. The $TCOD_{Mn}$ concentration in the treated wastewater using culture of iramobilization and suspension for the synthetic wastewater were found as 650mg/l and 1,250mg/l after 48hours, respectively. SVI(Sludge Volume Index) and $TCOD_{Mn}$ concentration were 74 and 73mg/l at optimum F/M ratio, 1.32kg-TCO $D_{Mn}$ /day. kg-MLVSS. The $TCOD_{Mn}$ concentration and removal efficiency were 213mg/l and 93.5% by continuous experiments in the air-lift bioreactor, respectively. The $TCOD_{Mn}$ concentration was 82mg/l, and also the MLVSS concentration was 2,550mg/l, when the volumetric loading rate was 3.04kg-$TCOD_{Mn}/m^{2}$ day for real polyester weight loss wastewater.

  • PDF

Numerical analysis of offshore monopile during repetitive lateral loading

  • Chong, Song-Hun;Shin, Ho-Sung;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • v.19 no.1
    • /
    • pp.79-91
    • /
    • 2019
  • Renewed interest in the long-term pile foundations has been driven by the increase in offshore wind turbine installation to generate renewable energy. A monopile subjected to repetitive loads experiences an evolution of displacements, pile rotation, and stress redistribution along the embedded portion of the pile. However, it is not fully understood how the embedded pile interacts with the surrounding soil elements based on different pile geometries. This study investigates the long-term soil response around offshore monopiles using finite element method. The semi-empirical numerical approach is adopted to account for the fundamental features of volumetric strain (terminal void ratio) and shear strain (shakedown and ratcheting), the strain accumulation rate, and stress obliquity. The model is tested with different strain boundary conditions and stress obliquity by relaxing four model parameters. The parametric study includes pile diameter, embedded length, and moment arm distance from the surface. Numerical results indicate that different pile geometries produce a distinct evolution of lateral displacement and stress. In particular, the repetitive lateral load increases the global lateral load resistance. Further analysis provides insight into the propagation of the shear localization from the pile tip to the ground surface.

Modeling of heated concrete-filled steel tubes with steel fiber and tire rubber under axial compression

  • Sabetifar, Hassan;Nematzadeh, Mahdi;Gholampour, Aliakbar
    • Computers and Concrete
    • /
    • v.29 no.1
    • /
    • pp.15-29
    • /
    • 2022
  • Concrete-filled steel tubes (CFSTs) are increasingly used as composite sections in structures owing to their excellent load bearing capacity. Therefore, predicting the mechanical behavior of CFST sections under axial compression loading is vital for design purposes. This paper presents the first study on the nonlinear analysis of heated CFSTs with high-strength concrete core containing steel fiber and waste tire rubber under axial compression loading. CFSTs had steel fibers with 0, 1, and 1.5% volume fractions and 0, 5, and 10% rubber particles as sand alternative material. They were subjected to 20, 250, 500, and 750℃ temperatures. Using flow rule and analytical analysis, a model is developed to predict the load bearing capacity of steel tube, and hoop strain-axial strain relationship, and axial stress-volumetric strain relationship of CFSTs. An elastic-plastic analysis method is applied to determine the axial and hoop stresses of the steel tube, considering elastic, yield, and strain hardening stages of steel in its stress-strain curve. The axial stress in the concrete core is determined as the difference between the total experimental axial stress and the axial stress of steel tube obtained from modeling. The results show that steel tube in CFSTs under 750℃ exhibits a higher load bearing contribution compared to those under 20, 250, and 500℃. It is also found that the ratio of load bearing capacity of steel tube at peak point to the load bearing capacity of CFST at peak load is noticeable such that this ratio is in the ranges of 0.21-0.33 and 0.31-0.38 for the CFST specimens with a steel tube thickness of 2 and 3.5 mm, respectively. In addition, after the steel tube yielding, the load bearing capacity of the tube decreases due to the reduction of its axial stiffness and the increase of hoop strain rate, which is in the range of about 20 to 40%.

Biological Treatment of Ethylene Glycol in Polyester Weight-Loss Wastewater Using Jet-Loop Reactor (Jet-Loop Reactor를 이용한 Polyester 감량폐수중 Ethylene Glycol의 생물학적 처리)

  • 류원률;최장승;조무환
    • KSBB Journal
    • /
    • v.14 no.1
    • /
    • pp.119-123
    • /
    • 1999
  • A jet-loop reactor was used for the biological treatment of ethylene glycol(EG) which is a main component of polyester weight-loss wastewater, and is difficult to be removed by physicochemical treatments. Volumetric oxygen coefficient(kLa) of jet-loop reactor was significantly larfgeer that of air-lift reactor. When organic loading rates of synthetic polyester weight-loss wastewater were 2.64 $kgOD_{Mn}/m^3$.day and 3.07 $kgCOD_{Cr}/m^3$.day, the effluent concentrations were measured as 154 $mgCOD_{Mn}/L$ and 156$mgCOD_{Cr}/L$, and removal efficiencies were found as 93%and 93.6%, respectively. The specific removal rate was proportionally increased from 0.25 to 1.60 $kgCOD_{Mn}$-removed/kgMLVSS.day as specific loading rate was increased from 0.25 to 1.72 $kgCOD_{Mn}$/kgMLVSS.day. Also, kinetics constants such as $K_s$, k, $K_d$, and Y were estimated as 89 mg/L, $0.05 hr^{-1}$, 0.1$day^{-1}$ and 0.78 respectively. When the organic loading rates of real polyester weight-loss wastewater were 2.64 $kgOD_{Mn}/m^3$. and 5.24 $kgCOD_{Cr}/m^3$. day, the effluent concentrations were measured as 150 $mgCOD_{Mn}$/L, and 306 $mgCOD_{Cr}$/L, and removal efficiencies were found as 93.2% and 93%, respectively. This study demonstrated that EG in the wastewater could be efficiently removed biologically using a jet-loop reactor.

  • PDF