• Title/Summary/Keyword: volume estimate

Search Result 877, Processing Time 0.034 seconds

Topological optimized design considering dynamic problem with non-stochastic structural uncertainty

  • Lee, Dong-Kyu;Starossek, Uwe;Shin, Soo-Mi
    • Structural Engineering and Mechanics
    • /
    • v.36 no.1
    • /
    • pp.79-94
    • /
    • 2010
  • This study shows how uncertainties of data like material properties quantitatively have an influence on structural topology optimization results for dynamic problems, here such as both optimal topology and shape. In general, the data uncertainties may result in uncertainties of structural behaviors like deflection or stress in structural analyses. Therefore optimization solutions naturally depend on the uncertainties in structural behaviors, since structural behaviors estimated by the structural analysis method like FEM need to execute optimization procedures. In order to quantitatively estimate the effect of data uncertainties on topology optimization solutions of dynamic problems, a so-called interval analysis is utilized in this study, and it is a well-known non-stochastic approach for uncertainty estimate. Topology optimization is realized by using a typical SIMP method, and for dynamic problems the optimization seeks to maximize the first-order eigenfrequency subject to a given material limit like a volume. Numerical applications topologically optimizing dynamic wall structures with varied supports are studied to verify the non-stochastic interval analysis is also suitable to estimate topology optimization results with dynamic problems.

A Study on Free Spray Patterns of Diesel with Ultra High Pressure (극초고압 디젤 자유분무의 분무양상에 관한 연구)

  • Jeong Daeyong;Lee Jongtai
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.3
    • /
    • pp.131-137
    • /
    • 2005
  • Ultra high pressure injection equipment was developed to estimate and analyze the spray characteristics in ultra high pressure injection. Spray patterns were visualized by schlieren method and analyzed in ultra high pressure. Spray tip penetration, spray thickness, spray volume, and entrained air mass increased with the increase of the injection pressure. But over 2,800 bars of the injection pressure region, it was shown that the rate of improvement was not increased remarkably ,and the spray characteristics such as spray penetration, volume, and entrained air mass were reversed and got worse at 4,140 bars.

A study of the performance on large capacity screw compressors (중대형 스크루 압축기의 성능에 관한 연구)

  • Park, D.S.;Yang, S.H.;Lee, D.J.;Shin, J.K.;Yoo, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.668-671
    • /
    • 2001
  • For the saving of energy consumption, it is necessary that the high efficient energy transfer machine. We found the optimum operating condition of screw water chiller during this performance test. The specifications of compressor for this performance test are as follows. Built-in volume ratio; Vi=2.4, using refrigerant; HCFC-22, nominal motor output; 60kW(80Hp). We found the test results on water cooled chiller standard test condition that the evaporating capacity is increased 8% maximum and 5.6% under same operating condition. and COP is increased 11 % max. and 8% under same operating condition with change of the evaporating inlet/outlet condition. For the results of these test, we can estimate the optimum operating condition of water cooled type screw chiller.

  • PDF

Ground water in the four major basins in Korea (사대강유역의 지하수)

  • 최승일
    • Water for future
    • /
    • v.12 no.1
    • /
    • pp.21-27
    • /
    • 1979
  • Ground water stored in the alluvium and the rocks provides the vase flow of the streams and can be withdraw from wells and infiltration galleries. And it is also recharge naturallyby precipitation. The amount of ground water in the four major basins it is estimated to be about 137,000 million cubiv meters(Table1), while nationwide ground water storage to be about 232,000 million cubic meters. The estimation of storage volume has been made on the basis of assumed thickness of the saturated zone of the different rocks and assumed porosities of those rocks. The values of the porosity of alluvium and saprolite were assumed to be 25% and 40% respectivvely which are based on tests made of similar materials in Georgia, U.S. The volume of water in storage is believed to be a conservative estimate. Detailed geologic and hydrologic investigation should be made where and when water resources are needed.

  • PDF

Effects of Washing of Food Wastes on Aerobic Composting (음식물쓰레기의 세척이 호기성 퇴비화에 미치는 영향)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • This study was performed to estimate the effects of washing of food wastes on temperature, pH, weight and volume reduction and salinity in aerobic composting of food wastes. Weight ratios of food wastes to water in washing were 1:0(Control), 1:1 (W-1), 1:2(W-2), 1:3(W-3) and :4(W-4), respectively. Ratios of food wastes to wood chips in reactor of Control, W-1, W-2, W-3 and W-4 were 5 kg:5 1, respectively. Reactors were operated for 24 days with 1 hour stirring by 1 rpm and 2 hours aeration per day. The increase in the ratio of food wastes to water used in washing resulted in the decrease of the highest reaction temperature and the elongation of the high temperature reaction period. The lowering of the ratio of food wastes to water used in washing resulted in faster pH increase and the steady state in the weight reduction rate and the volume reduction rate of composts. The final salinities of Control, W-1, W-2, W-3 and W-4 were 0.95%, 0.73%, 0.65%, 0.57% and 0.41%, respectively.

Investigation of the Thermal Characteristics of LED Bulb Utilizing Simulation of Finite Volume Method (FVM) (유한체적법(FVM)의 시뮬레이션을 활용한 LED 벌브의 열 특성 고찰)

  • Park, Kyoung-Min;Moon, Cheol-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.1-8
    • /
    • 2014
  • Heat dissipation of the high power LED is a critical issue. To estimate the junction temperature of the LED chip is most important in characterizing the heat dissipation, but it is impossible to directly measure it. In this study, surface temperatures of the 12.8W LED bulb was measured for 5 points using a data logger and compared with the simulated results using a thermal simulator based on FVM (finite volume method) to secure a reliability of the simulation. Effects of some factors such as lens, emissivity and air inlet were investigated using simulation works and then the results were analysed.

Development of the Pre-Release Simulation System Using Generic Agricultural System Simulator(GASS) (범용적 농업 시스템 시뮬레이터(GASS)를 이용한 예비방류 모의 시스템의 개발)

  • Song, Sang-Ho;Lee, Jeong-Jae;Kim, Han-Joong;Yi, Ho-Jae
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.539-542
    • /
    • 2003
  • In South Korea, flooding is controlled with large or small reservoirs scattered spatially over the territory. Because recent unexpected hard-rain events requires more flood control capacities, the pre-release system is considered with the most economical alternative. In this case time and volume of discharge should be determined by the simulation. But, existing pre-release simulation system has the problem of specificity. Therefore, GASS is considered to estimate the pre-release time and volume with different configurations of pre-release system. This paper shows that pre-release simulation system could be constructed with arranging GASAtmosphere, GASWatershed, Reservoir, Gate components using GASS. It is also shows that GASS could be used as a foundation for constructing pre-release simulation system that is easy to use and is flexible to reflect the changing configurations of reservoir systems.

  • PDF

Finite Element Analysis for Pearlite Transformation of Carbon Steel (탄소강의 펄라이트 변태에 대한 유한요소 해석)

  • 탄소강
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.69-75
    • /
    • 2000
  • The object of the research is to estimate for pearlite structure of quenched carbon steels. The effects of temperature on physical properties metallic structures and the latent heat by phase transformation were considered. In this study a set of constitutive equations relevant to the analysis of thermo-elasto plastic materials with pearlite phase transformation during quenching process way presented on the basis of continuum thermo-dynamics. The iso-thermal transformation curve of the SM50C was formlated by cubic spline curve. The formulated equations of evolution in pearlite transformation was used for structure analysis. The volume fraction of pearlite was obtained from the results of calculated metallic structure by Finite element equation.

  • PDF

A note on the Geostrophically Controlled Volume Transport of the Tgushima Current

  • Seung, Young-Ho
    • Journal of the korean society of oceanography
    • /
    • v.34 no.4
    • /
    • pp.231-235
    • /
    • 1999
  • A simple analytic model for estimating the volume transport of the Tsushima Current is considered by assuming that the transports through the connecting channels, the Korea and Tsugaru Straits, are geostrophically controled. The model gives a much simpler form of solution than that by Minato and Kimura (1980). It depends no longer on the geometry of the marginal sea and on the thickness of western boundary layer relative to the dimension of the ocean, but considers the geometry of the connecting channels ignored by Nof (1993). The external parameters turn out to be the oceanic meridional sea level difference between the two channels, the depth of the channels and the meridional position of the marginal sea. For typical value of the depth ratio of the channels to the ocean, the model gives an estimate of the Tsushima Current transport of acceptable magnitude.

  • PDF

Performance Analysis of a Heat Pump Using Refrigerant Mixtures (II) (혼합냉매를 사용한 열펌프의 성능해석 (II))

  • Kim, M.S.;Kim, T.S.;Won, S.P.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.218-225
    • /
    • 1990
  • Studies on the performance of a heat pump using non-azeotropic refrigerant mixtures are done. In order to estimate the thermodynamic properties for the selected non-azeotropic refrigerant mixtures including R22/R152a, R22/R142b, R22/R114 and R13B1/R152a, Peng-Robinson equation of state is adopted. The pressure-enthalpy diagram and the temperature-entropy diagram are plotted for each refrigerant mixture. Considerations on the capacity modulation for the heat pump system using refrigerant mixtures are taken into. Results show that when the heating load varies, the possibility for the capacity modulation is found in the heat pump system using a compressor with constant volume flow rate. Under a constant heating capacity condition in the heat pump system, the coefficient of performance increases when the refrigerant mixtures are used. The volume flow rate decreases as the mass fraction of lower boiler increases in this case.

  • PDF