• 제목/요약/키워드: voltage stress factor

검색결과 133건 처리시간 0.025초

불평형 전압 운전시의 역률보상용 커패시터 특성 연구 (A Study on the Characteristics for Power Capacitor under the Voltage Unbalance Operation)

  • 김일중;김종겸
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.36-40
    • /
    • 2008
  • Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor.

High Step-up DC-DC Converter by Switched Inductor and Voltage Multiplier Cell for Automotive Applications

  • Divya Navamani., J;Vijayakumar., K;Jegatheesan., R;Lavanya., A
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.189-197
    • /
    • 2017
  • This paper elaborates two novel proposed topologies (type-I and type-II) of the high step-up DC-DC converter using switched inductor and voltage multiplier cell. The advantages of these proposed topologies are the less voltage stress on semiconductor devices, low device count, high power conversion efficiency, high switch utilization factor and high diode utilization factor. We analyze the Type-II topologies operating principle and mathematical analysis in detail in continuous conduction mode. High-intensity discharge lamp for the automotive application can use the derived topologies. The proposed converters give better performance when compared to the existing types. Also, it is found that the proposed type-II converter has relatively higher voltage gain compared to the type-I converter. A 40 W, 12 V input voltage and 72 V output voltage has developed for the type-II converter and the performances are validated.

전압 불평형에서 콘덴서와 리액터의 직렬 연결시의 콘덴서의 특성 분석 (A Study on Condenser Characteristics at the Series Connection of Condenser and Reactor Under Voltage Unbalance)

  • 김일중;김종겸;박영진;김성헌
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.325-329
    • /
    • 2010
  • Capacitor has been used principally for the power factor compensation long ago. However now it does as passive filter to reduce harmonics of nonlinear load with reactor. Most of the customer's low-voltage feeder has been designed with approximately balanced and connected at the 3 phase four wire system. But voltage and current unbalance is appeared by the mixing operation of single or three phase load etc. The addition of reactor at the condenser may rise its terminal voltage. Voltage and current values above rating can act on electrical stress on the condenser. In this paper, we calculated and measured that voltage, current and capacity of condenser are changed under the voltage balance. We conclude that magnitude and deviation of phase voltage act on major point of electrical stress.

입력전류와 커패시터 전압의 맥동저감을 위한 개선된 LCCT Z-소스 DC-AC 인버터 (Improved LCCT Z-Source DC-AC Inverter for Ripple Reduction of Input Current and Capacitor Voltage)

  • 신연수;정영국;임영철
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1432-1441
    • /
    • 2012
  • In this study, an improved LCCT(Inductor-Capacitor-Capacitor-Trans) Z-source inverter(Improved LCCT ZSI) with characteristics of Quasi Z-source inverter(QZSI) and LCCT Z-source inverter(LCCT ZSI) is proposed. The proposed inverter can also reduce the voltage stress and input current/capacitor voltage ripples compared with conventional LCCT ZSI and Quasi ZSI. A two winding trans in Z-impedance network of the conventional LCCT ZSI is replaced by a three winding trans in the proposed inverter. To verify the validity of the proposed inverter, a DSP controlled hardware was made and PSIM simulation was executed for each method. Comparing the current and voltage ripples of each method under the condition of input DC voltage 70[V] and output AC voltage 76[Vrms], the input current and capacitor voltage ripple factors of the proposed inverter were low as 11[%] and 1.4[%] respectively. And, for generation of the same output AC voltage of each method, voltage stress of the proposed inverter was low as 175[V] under the condition of duty ratio D=0.15. As mentioned above, we could know that the proposed inverter have the characteristics of low voltage stress, low ripple factor and low operation duty ratio compared with the conventional methods. Finally, the efficiency according to load change/duty ratio and the transient state characteristics were discussed.

3상 Switched Trans Z-소스 직류/교류 전력변환기의 스트레스 및 과도상태 특성 (Characteristics of Transient State and Stress of Three-Phase Switched Trans Z-Source DC/AC Power Converter)

  • 임영철;김세진;정영국
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.57-66
    • /
    • 2012
  • When typical Z-source DC/AC inverter(ZSI) is operated in high voltage gain area, because of its high duty ratio, voltage and current stress in Z-network of typical ZSI are increased. This paper proposes a new switched trans ZSI(STZSI) with two switched trans cells which consist of one trans and two diodes. To confirm the operation performance of the proposed system, the PSIM simulation is performed for typical ZSI, switched inductor ZSI and the proposed STZSI. Voltage / current stress and transient state characteristics of each method are compared under the condition of DC input voltage 100[V] and output phase voltage 66[Vrms]. As a result, we confirmed that transient state of the proposed STZSI is short compared with the conventional ZSI because the high voltage gain is obtained using the same duty ratio, also a low duty ratio is required for the same output voltage. Finally, we could know the proposed system have low voltage and current stress in Z-network compared with the conventional ZSI.

Analysis the Reliability of Multilayer Ceramic Capacitor with inner Ni Electrode under highly Accelerated Life Test Conditions

  • Yoon, Jung-Rag;Lee, Kyung-Min;Lee, Serk-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권1호
    • /
    • pp.5-8
    • /
    • 2009
  • The reliability of multilayer ceramic capacitor with active thin dielectric layer was investigated by highly accelerated life test at various stress condition. The distribution of multilayer ceramic capacitor failure times is plotted as a function of time from Weibull distribution function. According to the test result, voltage acceleration factor is obtained from 2.24 to 2.96. The acceleration by temperature is much higher than other values of active thick dielectric layer. It is clear that median time to failure is affected by the stress voltage for high volumetric efficiency ceramic capacitors with active thin dielectric layer. The degradation under stress of voltage involves electromigration and accumulation of oxygen vacancy at Ni electrode interface of cathode.

New Zero-Current-Transition (ZCT) Circuit Cell Without Additional Current Stress

  • Kim, C.E.;Park, E.S.;G.W. Moon
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.215-223
    • /
    • 2003
  • In this paper, a new zero-current-transition (ZCT) circuit cell is proposed. The main switch is turned-off under the zero current and zero voltage condition, and there is no additional current stress and voltage stress in the main switch and the main diode, respectively. The auxiliary switch is turned-off under the zero voltage condition, and the main diode is turned-on under the zero voltage condition. The resonant current required to obtain the ZCT condition is relatively small and regenerated to the input voltage source. The operational principles of a boost converter integrated with the proposed ZCT circuit cell are analyzed and verified by the simulation and experimental results.

불평형 전압 동작시 전력 커패시터 특성 분석 (Characteristics Analysis of Power Capacitor with Unbalanced Voltage Operation)

  • 김종겸;박영진;이은웅
    • 조명전기설비학회논문지
    • /
    • 제22권5호
    • /
    • pp.64-72
    • /
    • 2008
  • 3상 4선식 전원공급에서 부하의 불평형 운전에 의한 전압 불평형은 전류 불평형을 일으켜 기기의 손실증가에 따른 출력 감소로 전원용량을 증가시키는 것은 물론이고 전기 품질에도 나쁜 영향을 미치고 있다. 전력용 커패시터는 유도성 부하의 역률 보상과 전원을 안정시키기 위해 사용되며, 유도전동기의 여자에 필요한 자화성분을 전원을 대신하여 제공하기도 한다. 전압 불평형이 지속될 경우 커패시터에 전압 스트레스로 작용하여 절연 고장을 일으킬 수 있다. 본 논문에서는 역률 개선용 커패시터가 전압 불평형 증가에 의해 받는 영향을 해석한 결과 전압 및 전류의 크기가 함께 증가하여 스트레스는 점차적으로 높아진다는 것을 확인할 수 있었다.

선택적 주파수 변환방식에 의한 단상 역률보상회로의 캐패시터전압 및 입력전류 고조파왜곡의 감소 (REDUCTION OF VOLTAGE STRESS AND INPUT CURRENT HARMONIC DISTORTION IN SINGLE STAGE PFC CONVERTER BY SELECTIVE VARIABLE FREQUENCY CONTROL)

  • 최항석;이규찬;조보형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.1999-2001
    • /
    • 1997
  • The main two drawbacks of the Sin91e Stage PFC (SS-PFC) converters employing a DCM Boost PFC cell are relatively high voltage stress on the bulk capacitor and the input current harmonic distortion. The high voltage stress on bulk capacitor makes the SS-PFC converter impractical in a universal input application and the input current harmonic distortion lowers power factor. In this paper a selective variable frequency control that reduces the voltage stress on the bulk capacitor and the input current harmonic distortion is proposed. Computer simulation results of the proposed control method are presented.

  • PDF

고압 유도전동기 역률 보상설비의 특성 해석 (A Characteristic Study on the Power Factor Compensation Application of High Voltage Induction Motor)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.225-230
    • /
    • 2008
  • Reactor starting method has the advantage of simplicity and closed transition in spite of lower starting torque per kVA. This method allows a smooth start with almost no observable disturbance on transition and is suitable for applications such as centrifugal pumps or fans. Reactive power doesn't contribute to work but needs to sustain the electromagnetic field required for the induction motor to operate. Starting power factor of induction motor is specially lower than running power factor. Power factor application is needed to compensate for the lower power factor of induction motor. This power factor compensation systems is occasionally being hit by the effects of the starting reactor connection position at the starting, stopping of high-voltage induction motor. This paper describes voltage and current stress affected by the installation position of power factor compensation application at the reactor starting method.