• 제목/요약/키워드: voltage standard

검색결과 977건 처리시간 0.034초

특별고압 전선로에 대한 인체접근한계의 이론적연구 (A Study on the Theoretical Analysis of Human Body Approximation to Special High Voltage Eletric Lines)

  • 김상렬;김찬오;이재인
    • 한국안전학회지
    • /
    • 제5권3호
    • /
    • pp.44-50
    • /
    • 1990
  • This study is conducted to examine the theoretical background of characteristics for electric shock encountered in special high-voltage electric lines among the accidents of electric shock, and to calculate applied current to human body and field strength over the head by means of numerical anaysis through FEM(Finite Element Method), and to make clear the hazard level to the human body, and to establish the approach limit distance of human body to the electric lines, which could be applied to the safety standard while working in the vicinity of special high-voltage electric lines.

  • PDF

200 kV 용량형 분압기 2대를 이용한 교류 고전압 측정범위 확장 (Measurement Range Extension of AC High Voltage using two 200 kV Capacitive Dividers)

  • 정재갑;이상화;강전홍;김명수;김윤형;한상길;정진혜;한상옥;정종만
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.1-5
    • /
    • 2008
  • The output voltage value of AC high voltage source has been usually obtained by multiplying low voltage value measured at both terminals of low voltage resistor by the dividing ratio of the high voltage capacitive divider. From the dividing ratio determined of each 200 kV capacitive divider, we have developed step-up method for measuring the output voltage up to 400 kV using two same type of 200 kV capacitive dividers connected in series. The theoretical dividing ratio of 400 kV capacitive dividers connected in series coincides with that of manufacturer's certification within measurement uncertainty. Thus, this developed step-up method makes it possible to extend the range of output voltage from 200 kV to 400 kV. Furthermore, The dividing ratio of divider under test obtained using this step-up method is consistent with that obtained using one 200 kV high voltage divider within corresponding uncertainties.

인식거리 향상을 위한 UHF 대역 RFID 태그용 전압체배기 설계 (Design Consideration of the Voltage Multiplier of UHF RFID Tag for Increased Reading Range)

  • 이종욱;이범선
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.587-590
    • /
    • 2005
  • We investigated the input impedance characteristics of UHF-band RFID tag chip for increased reading range. A voltage multiplier designed using 0.4 ${\mu}m$ $zero-V_T$ MOSFET showed that DC output voltage of 2 V can be obtained using standard CMOS process. The input impedance of the voltage multiplier was examined to achieve impedance level for maximum reading distance using analytical and numerical approaches. The input impedance of the voltage multiplier could be varied in a wide range by selecting the size of MOSFET and the number of multiplying stages of the voltage multiplier, and thus, the impedance level required for the tag antenna can be obtained in presence of other tag circuit blocks.

  • PDF

저 소비전력 OLED 구동 IC 응용을 위한 새로운 구조의 Low Voltage Reference 회로 설계에 관한 연구 (A Novel Low Voltage Reference Circuit for Low Power OLED Driver ICs)

  • 김재헌;신홍재;이재선;최성욱;곽계달
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.923-926
    • /
    • 2003
  • This paper presents a novel low voltage reference circuit under the MOS threshold voltage(V$_{th}$) in standard CMOS process. It is based on the weighted difference of the gate-source voltages of an NMOS and a PMOS operating in saturation region. The voltage reference is designed for low power OLED driver ICs. The proposed circuit is designed using 0.35${\mu}{\textrm}{m}$ CMOS technology. The minimum supply voltage is 2V, and the typical temperature coefficient is 99.6ppm/ C.C.

  • PDF

UP/DOWN 변환이 동시에 지원되는 다중 전압 단일 출력 DC/DC 변환기 (A Multiple-Voltage Single-Output DC/DC Up/Down Converter)

  • 조상익;김정열;임신일;민병기
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.207-210
    • /
    • 2002
  • This paper describes a design of multiple-mode single-output DC/DC converter which can be used in both up and down conversion. Proposed up/down converter does not produce a negative voltage which is generated in conventional buck-boost type converter. Three types of operation mode(up/down/bypass) are controlled by the input voltage sense and command signals of target output voltage. PFM(pulse frequency modulation) control is adopted and modified for fast tracking and for precise output voltage level with an aid of output voltage sense. Designed DC/DC converter has the performance of less than 5 % ripple and higher than 80 % efficiency. Chip area is 3.50 mm ${\times}$ 2.05 mm with standard 0.35 $\mu\textrm{m}$ CMOS technology.

  • PDF

철심 코어형 전자식 전압 변성기 개발 (Development of the iron-cored electronic voltage transformer)

  • 강용철;박종민;장성일;김연희;최정환;김용균;송인준;안용호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.138-139
    • /
    • 2008
  • An iron-cored voltage transformer(VT) is usually used to obtain the standard low voltage signal for protection and measurement. Generally, the iron-cored transformers have errors due to the hysteresis characteristics of the iron-core. An error compensating algorithm for iron-cored instrument transformer can improve the accuracy of conventional voltage transformers. This paper describes the iron-cored electronic voltage transformer having the error compensating algorithm. The innovative product composes an iron-cored VT and an intelligent electronic device(IED) having the error compensating algorithm. The test results of the iron-cored electronic voltage transformers in Korea Electro-technology Research Institute(KERI) are presented.

  • PDF

장간유리애자 파손시 절연파괴 특성 (The Electrical Breakdown Characteristics of Broken Toughened Glass Stem Insulator)

  • 정종욱;정진수;김영석
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1398-1406
    • /
    • 2008
  • This paper describes the electrical breakdown characteristics of broken toughened glass stem insulators by comparing with those of sound ones. The broken toughened glass stem insulators were taken from the electric railway field. According to the international standards, the sound and broken toughened glass stem insulators were tested in electrical strength. In the test, the power frequency voltage and the impulse voltage with a standard waveform were applied to the insulators. The power frequency voltage tests were carried out under both dry and wet condition and the impulse voltage tests under only dry condition. The acquired results were compared one another and discussed in electrical breakdown characteristic by analyzing the flashover progress pictures. As a result, the electrical strength of the broken toughened glass insulators was acquired and the processes of the surface breakdown on the toughened glass insulators were confirmed.

척추경 나사못 삽입술 CT검사의 영상평가 분석 (Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion)

  • 황형석;임인철
    • 한국방사선학회논문지
    • /
    • 제16권2호
    • /
    • pp.131-139
    • /
    • 2022
  • 본 연구는 척추경 나사못(Pedicle screw)을 돼지 흉추에 삽입하여 일반적인 CT검사(Non MAR)와 인공물을 줄이기 위한 금속성 인공물 감소기법(Metallic Artifact Reduction for Orthopedic Implants, O-MAR)으로 얻어진 흉추 Axial영상을 4개의 알고리즘(Standard, Soft, Bone, Detail)에 재구성하였다. 이에 얻은 영상을 image J 프로그램을 이용하여 신호대잡음비(Signal Noise Ratio, SNR)와 대조도대잡음비(Contrast to Noise Ratio, CNR)를 주어진 식에 의거하여 측정값을 구하고 흉추 척추경 나사못 삽입술 CT검사에 맞는 관전압과 알고리즘을 알아보고자 하였다. 결과적으로 Non MAR 사용한 경우에는 80, 100, 120, 140 kVp에서 soft 알고리즘이 SNR, CNR이 가장 높게 나타났다. 반면에 MAR를 사용한 경우 80 kVp에서는 Standard 알고리즘이 가장 높게 나타났고 100 kVp에서는 Standard, Soft 알고리즘이 비슷한 값으로 높게 나타났다. 120 kVp에서는 Soft, Standard 알고리즘이 비슷한 값으로 나타났고 140 kVp에서는 Soft 알고리즘에서 SNR, CNR이 가장 높게 나타났다. 따라서 Non MAR와 MAR를 비교했을 경우 MAR를 사용한다고 하더라도 관전압 변화에 따라 모든 알고리즘에서 SNR과 CNR이 증가하는 것은 아니었다. 본 연구는 이후 척추경 나사못 CT검사 영상 평가에 도움이 되는 기초자료로써 선택적인 관전압과 알고리즘 사용으로 영상의 질을 더 높일 수 있는 계기가 될 것으로 사료된다.

Optimal Algorithms for Voltage Management in Distribution Systems Interconnected with New Dispersed Sources

  • Rho, Dae-Seok;Kook, Kyung-Soo;Wang, Yong-Peel
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.192-201
    • /
    • 2011
  • The optimal evaluation algorithms for voltage regulation in the case where new dispersed sources are operated in distribution systems are studied. Handling the interconnection issues for proper voltage managements are often difficult and complicated because professional skills and enormous amounts of data during evaluations are needed. Typical evaluation algorithms mainly depend on human ability and quality of data acquired, which inevitably cause the different results for the same issue. Thus, unfair and subjective evaluations are unavoidable. In order to overcome these problems, we propose reasonable and general algorithms based on the standard model system and proper criterion, which offers fair and objective evaluation in any case. The proposed algorithms are divided into two main themes. One is an optimal algorithm for the voltage control of multiple voltage regulators in order to deliver suitable voltage to as many customers as possible, and the other is a proper evaluation algorithm for the voltage management at normal and emergency conditions. Results from a case study show that proposed methods can be a practical tool for the voltage management in distribution systems including dispersed sources.