• Title/Summary/Keyword: voltage standard

Search Result 977, Processing Time 0.032 seconds

CMOS on-chip voltage and current reference circuits for low-voltage applications (저전압용 CMOS 온-칩 기준 전압 및 전류 회로)

  • 김민정;이승훈
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.4
    • /
    • pp.1-15
    • /
    • 1997
  • This paper proposes CMOS on-chip voltage and current reference circuits that operate at supply voltages between 2.5V and 5.5V without using a vonventional bandgap voltage structure. The proposed reference circuits based on enhancement-type MOS transistors show low cost, compatibility with other on-chip MOS circuits, low-power consumption, and small-chip size. The prototype was implemented in a 0.6 um n-well single-poly double-metal CMOS process and occupies an active die area of $710 um \times 190 um$. The proposed voltage reference realizes a mean value of 0.97 V with a standard deviation of $\pm0.39 mV$, and a temperature coefficient of $8.2 ppm/^{\circ}C$ over an extended temeprature range from TEX>$-25^{\circ}C$ to $75^{\circ}C$. A measured PSRR (power supply rejection ratio) is about -67 dB at 50kHz.

  • PDF

VLSI Design of Low Voltage DC/DC Converter using Zero Voltage Switching Technique (Zero Voltage Switching을 이용한 저전압 DC/DC 컨버터의 고집적회로 설계)

  • 전재훈;김종태;홍병유
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.564-571
    • /
    • 2001
  • This paper presents the VLSI design of highly efficient low voltage DC/DC converter for portable devices. All active devices are integrated on a single chip using a standard 0.65$\mu\textrm{m}$ CMOS process. The converter operates at the switching frequency of 1MHz for reducing the size of passive elements and uses a ZVS for minimizing the switching loss at high frequency. Simulation results show that the circuit can achieve a 95% efficiency when the output voltage is controlled to be 2V with the load of lW.

  • PDF

Dynamic Voltage Restorer Applied to Real Power System using Voltage Sag Detection (전압강하 검출을 이용한 동적전압보상기의 실계통 적용)

  • Lee, Hyun-Woo;Park, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.203-204
    • /
    • 2015
  • 본 논문은 실제 전력계통을 모의한 A계통에서 3상 지락 사고가 발생하였을 때, 순시 전압강하를 보상하기 위한 동적전압보상기(Dynamic Voltage Restorer)의 동작에 따른 해당 부하의 영향성을 연구하였다. 동적전압보상기의 동작을 위한 전압강하 검출은 RMS Detection 기법을 통해 구현하였으며, IEEE Standard 1159-1995의 기술된 Voltage Sag의 정의에 따라 동적전압보상기의 on/off 제어를 수행하였다. A계통 모델링을 포함한 모든 시뮬레이션은 PSCAD/EMTDC 상에서 구현하였으며, RMS 전압 측정 및 Voltage Sag 검출 신호, 그리고 동적전압보상기의 동작 전 후에 따른 순시 부하전압 파형을 결과로 다룰 것이다.

  • PDF

A Review of Methods for Calculation of Induced Voltage to a Communication Line from Distribution Power Line (배전선로가 초고속통신망에 미치는 유도장해 요소 분석)

  • Lim, Yong-Hun;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1956-1958
    • /
    • 2002
  • This paper reviews the calculation of induced voltage to a communication line from Power Transmission Line. Power lines, both overhead and underground, often run parallel to weak current lines, such as telecommunication, signal or data transmission systems or protection circuits. The coexistence of both systems in parallel over long lengths is accompanied by the possible induction of significant longitudinal voltage in the weak current line. In order to evaluate a precise induced voltage, this paper indicated problem about coefficient and numerical formula and present some induced voltage production technology standard application.

  • PDF

Fabrication and Characterization of the Silicon Vertical Hall Devices (실리콘 종형 홀 소자의 제조 및 그 특성)

  • 류지구;최세곤
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.3
    • /
    • pp.72-78
    • /
    • 1992
  • The Silicon vertical Hall devices are fabricated using standard bipolar process and characterized in terms of the Hall voltage, sensitivities, and offset voltage. The Hall voltage and sensitivity of the devices showed good linearity with respect to the magnetic flux density and reverse supply voltage Vr. The sensitivity of device with P$^{+}$ isolation dam has been increased up to 1.2 times compared to that of device without the dam. With the condition of V$_{r}$=-5.0[V], B=0.4[T] and I$_{sup}$=1.0[mA], the Hall voltage and sensitivity of the device with P$^{+}$ isolation dam were about 29[mV] and 74[V/AT], respectively. These vertical Hall devices can be used as the adjustable magnetic fields sensor.

  • PDF

Control of PCC Voltage Variation by Reactive Power Compensation of Distributed Source (분산전원의 무효전력 보상을 통한 PCC 전압 변동 제어)

  • Han, Sanghun;Lim, Jong-ung;Han, Yu;Cho, Younghoon;Choe, Gyu-ha
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.180-181
    • /
    • 2017
  • Recently as distributed source has increased, the distribution system has changed from unidirectional power flow to bi-directional power flow. This power flow causes the PCC voltage variation, which can adversely affect voltage sensitive loads. In this paper, the relation between the active power, reactive power and PCC voltage of the distributed source is analyzed, and the PCC voltage control scheme by reactive power compensation is proposed in the distributed source itself. In addition, limitations and conditions according to the standard for interconnecting distributed resources are specified and verified through simulation.

  • PDF

Transport of SVS from Sudagu to Yangju and Study about harmonic wave, feature of control (서대구S/S SVC의 양주S/S 이설관련 고조파 및 제어특성 검토)

  • Jang, Suk-Han;Shin, Soon-Young;Choi, Man-Sik;Youn, Jong-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.633-635
    • /
    • 2007
  • To cope with increasing power demand in metropolitan area, the power system in Korea has equipped with unit generator of large capacity, high density and uneven distribution, and transmission line of long distance, large capacity and high voltage. As the power system growing up enormous, it has become difficult to maintain the standard voltage in case of radical fluctuation of load or severe change of voltage by power system fault for its weakness of responsive characteristics although the power condenser has been installed to solve the unstability by lack of reactive power. Consequently, we review harmonic wave production and control characteristics to solve unstability problem of voltage in northern metropolitan, to reduce transmission restriction cost and to minimize load shedding by relocation of SVC (Static Var Compensator), which is highly effective for improvement of responsive characteristics for radical voltage fluctuation.

  • PDF

Voltage Unbalance Evaluation in Autotransformer-Fed Electric Railway Systems using Circuit Analysis (회로해석을 이용한 전기철도 급전시스템의 전압불평형 평가)

  • 오광해;차준민
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.20-28
    • /
    • 1998
  • This study proposes a new method to estimate voltage unbalance more exactly using Thevenin's equivalent circuit. The conventional simple formula were easily applied to evaluate voltage unbalance. Because the formula was derived on the assumption that traction load would be directly connected to the secondary windings of the main transformer, they could not consider the detailed characteristics of traction power supply system, for example, self and mutual impedances of rail, catenary and return feeder. So, the ac쳐racy of the results could not be guaranteed. The proposed algorithm is applied to a standard autotransformer-fed test system to analyze unbalance phenomena. Through simulations, we could evaluate voltage and current unbalance factors and compare the voltage unbalance of the three transformer connection schemes : single phase, V- and Scott-connections which are required for suitable train operation schedules. Additionally, we could determine the combinations of trains which can be operated under the unbalance factor limits.

  • PDF

An examination on proper voltage operation standard for 154kV power system through demand analysis (수요분석을 통한 154kV 계통전압 유지기준 설정)

  • Lee, Ik-Jong;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.428-431
    • /
    • 2009
  • KPX sets up the voltage standards according to the voltage level to supply a good quality of electricity to customers. Supply voltages are divided into 4 levels - 345kV, 154kV, 22.9kV, and distribution voltage consisting of 110, 220 and 380V. In this research, we examine the optimal voltage operating level focused on 154kV system that mostly affects electricity quality, through analysing the system demand.

  • PDF

Voltage source multilevel module converter valve test circuit research (전압원 멀티레벨 컨버터 밸브 시험회로 연구)

  • Yuan, Zhen;Lee, Jinhee;Jung, Teagsun;Baek, Seungtaek
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.79-80
    • /
    • 2014
  • Voltage source multilevel module converter attracts more and more attention recently. The core component of the voltage source multilevel module converter is the valve based on IGBT. So the test circuit for the valve is very important, reliable test method can guarantee the converter valve design meet the operation requirement. This paper analyzes the valve voltage and current stress during the operation, and according to IEC standard test requirement, object, condition, introduces a kind of test circuit. Finally, through the simulation model, to verify the test circuit can provide the proper test condition for the voltage source multilevel module converter valve.

  • PDF