• Title/Summary/Keyword: voltage record

Search Result 24, Processing Time 0.021 seconds

Introduction of Data Analysis Method for Ageing Diagnosis of Polymer Insulator (복합 고분자 애자의 열화 진단 데이터 분석 기법)

  • Choi, Nam-Ho;Lee, Byoung-Sung;Cho, Sung-Soo;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1611-1613
    • /
    • 1999
  • This paper introduces the data processing method and the measurement of the leakage current flowing through polymer insulators. For ageing diagnosis of polymer insulator, data aquisition system was developed to record the leakage current of insulator being tested. Hence, we have gained information for life time from its leakage current. the DAS is protected against over-voltage which would develop in the event of a flashover of the test sample.

  • PDF

Low-impedance Tetrodes using Carbon Nanotube-Polypyrrole Composite Deposition

  • Kim, Minseo;Shin, Jung Hwal;Lim, Geunbae
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.73-78
    • /
    • 2017
  • A tetrode is one of the neural electrodes, and it is widely used to record neural signals in the brain of a freely moving animal. The impedance of a neural electrode is an important parameter because it determines the signal-to-noise ratio of the recorded neural signals. Here, we developed a modification technique using carbon nanotube-polypyrrole composite nanostructures to decrease the impedances of tetrodes. The synthesis of the carbon nanotube and polypyrrole nanostructures was performed in two steps. In the first step, randomly dispersed carbon nanotubes and pyrrole monomers were gathered and aligned on the tetrode electrode. Next, they were electro-polymerized on the electrode surface. As the applied time (step-1 and step-2) and the offset voltage increased, the impedances of the tetrodes decreased. The modification technique is, therefore, an important and useful of lowering the impedances of tetrodes.

Fabrication and Characterization of InP JFET's for OEIC's (광전자집적회로를 위한 InP JFET의 제작 및 특성 분석)

  • 박철우;정창오;김성준
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.10
    • /
    • pp.29-34
    • /
    • 1992
  • JFET's with gate lengths ranging from 1$\mu$m to 8.3$\mu$m are successfully fabricated on InP substrate where the long haul (1.3$\mu$m~8.3$\mu$m) OEIC's(OptoElectronic Integrated Circuits) have been made. The pn junction of InP JFET's is made by co-implantation and RTA process. JFET's have etched-mesa-gate structure and the maximum gm larger than 90mS/mm was measured and this is the highest record in JFET's of such structure without S/D n$^{+}$ ion implantation. To maintain maximum g$_m$ should be well controlled the overetch of n-layer which inevitably occurs during etching off the unused p-layer. The I-V characteristic is checked during p-layer etch, for this purpose. A dc voltage gain of 11 is obtained from a preamplifier circuit thus fabricated.

  • PDF

Tree aging observation of XLPE by image processing (화상처리에 의한 XLPE의 트리열화관측)

  • 임장섭;김태성;길촌승
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.551-557
    • /
    • 1995
  • For the observation of treeing, a visual measurement with an optical microscope has been used to explain breakdown mechanism in high-voltage systems. The conventional directed visual method of tree aging observation is difficult to measure in short time processing, and it is impossible to analyze on tree degradation area, progressed direction, tree pattern, etc. By using an image processing technique, the tree features which appear immediately after the tree initiation as well as changes in the configuration of the tree can be easily measured and observed than using the conventional visual methods. In this paper, we have developed a tree observating system by using image processing for tree growth, degradation area and other treeing progress. As an experimental result, it can be concluded that the image processing method is a more effective alternative than directed visual observation method. As a matter of fact, it is possible to record the image of tree propagation immediately after its first appearance and explain the characteristics of tree growth froth the computer processing image.

  • PDF

Development of a High-Performance Bipolar EEG Amplifier for CSA System (CSA 시스템을 위한 양극 뇌파증폭기의 개발)

  • 유선국;김창현;김선호;김동준
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.205-212
    • /
    • 1999
  • When we want to observe and record a patient's EEG in an operating room, the operation of electrosurgical unit(ESU) causes undesirable artifacts with high frequency and high voltage. These artifacts make the amplifiers of the conventional EEG system saturated and prevent the system from measuring the EEG signal. This paper describes a high-performance bipolar EEG amplifier for a CSA (compressed spectral array ) system with reduced ESU artifacts. The designed EEG amplifier uses a balanced filter to reduce the ESU artifacts, and isolates the power supply and the signal source of the preamplifier from the ground to cut off the current from the ESU to the amplifier ground. To cancel the common mode noise in high frequency, a high CMRR(common mode rejection ratio) diffferential amplifier is used. Since the developed bipolar EEG amplifier shows high gain, low noise, high CMRR, high input impedance, and low thermal drift, it is possible to observe and record more clean EEG signals in spite of ESU operation. Therefore the amplifier may be applicable to a high-fidelity CSA system.

  • PDF

Characteristics of Organic Thin Film Transistors with Organic and Organic-inorganic Hybrid Polymer Gate Dielectric (유기물과 유무기 혼합 폴리머 게이트 절연체를 사용한 유기 박막 트랜지스터의 특성)

  • Bae, In-Seob;Lim, Ha-Young;Cho, Su-Heon;Moon, Song-Hee;Choi, Won-Seok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1009-1013
    • /
    • 2009
  • In this study, we have been synthesized the dielectric layer using pure organic and organic-inorganic hybrid precursor on flexible substrate for improving of the organic thin film transistors (OTFTs) and, design and fabrication of organic thin-film transistors (OTFTs) using small-molecule organic semiconductors with pentacene as the active layer with record device performance. In this work OTFT test structures fabricated on polymerized substrates were utilized to provide a convenient substrate, gate contact, and gate insulator for the processing and characterization of organic materials and their transistors. By an adhesion development between gate metal and PI substrate, a PI film was treated using $O_2$ and $N_2$ gas. The best peel strength of PI film is 109.07 gf/mm. Also, we have studied the electric characteristics of pentacene field-effect transistors with the polymer gate-dielectrics such as cyclohexane and hybrid (cyclohexane+TEOS). The transistors with cyclohexane gate-dielectric has higher field-effect mobility, $\mu_{FET}=0.84\;cm^2/v_s$, and smaller threshold voltage, $V_T=-6.8\;V$, compared with the transistor with hybrid gate-dielectric.

Effect of Capsaicin on Delayed Rectifier $K^+$ Current in Adult Rat Dorsal Root Ganglion Neurons

  • Hahn, Jung-Hyun;Chung, Sung-Kwon;Bang, Hyo-Weon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 2000
  • $K^+$ currents play multiple roles in the excitability of dorsal root ganglion (DRG) neurons. Influences on these currents change the shape of the action potential, its firing threshold and the resting membrane potential. In this study, whole cell configuration of patch clamp technique had been applied to record the blocking effect of capsaicin, a lipophilic alkaloid, on the delayed rectifier $K^+$ current in cultured small diameter DRG neurons of adult rat. Capsaicin reduced the amplitude of $K^+$ current in dose dependent manner, and the concentration-dependence curve was well described by the Hill equation with $K_D$ value of $19.1{\mu}M.$ The blocking effect of capsaicin was reversible. Capsaicin $(10 {\mu}M)$ shifted the steady-state inactivation curve in the hyperpolarizing direction by about 15 mV and increased the rate of inactivation. The voltage dependence of activation was not affected by capsaicin. These multiple effects of capsaicin may suggest that capsaicin bind to the region of $K^+$ channel, participating in inactivation process.

  • PDF

Implementation of on Expert System to Supervise GIS Arrester Facilities (GIS 피뢰설비 관리를 위한 전문가 시스템 구현)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Il-Kwon;Moon, Seung-Bo;Kwon, Jang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.75-81
    • /
    • 2007
  • This paper dealt with the design and implementation of an expert system to monitor and diagnose the lightning arresters in GIS substations. The expert system consists of a data acquisition module(DAM) based on microprocessor and diagnostic algorithms. The DAM measures and analyzes several parameters necessary for the arrester diagnosis such as system voltages, leakage current components, and temperatures. Also, it includes an intelligent surge counter which can record the date and tin, the polarity, and the amplitude of surge currents. All the data acquired is transmitted to a remote computer by a low rate wireless network specified in IEEE 802.15.4 to avoid electromagnetic intereference under high voltage and large current environments. The decision-making for the arrester diagnosis completes with a Java Expert System Shell(JESS) which is composed of a knowledge base, an inference engine and a graphic user interface(GUI).

AN INTEGRATED EMG STUDY OF RELATIONSHIPS BETWEEN PREFERRED CHEWING AND SIDE OF INITIAL MUSCLE PAINS (습관적(習慣的) 저작(咀嚼)과 저작근(咀嚼筋)의 동통유발(疼痛誘發)과의 관계에 대한 근전도학적(筋電圖學的) 연구(硏究))

  • Lee, Sung-Bok;Choi, Dae-Gyun;Choi, Boo-Byung;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.165-176
    • /
    • 1986
  • The purpose of this study was to investigate electromyographically the relationship between preferred chewing side and side of initial muscle pains. In this study, 20 normal healthy subjects were selected , and each subject chewed randomly chewing gum for 20 minutes to establish preferred chewing side. To induce initial muscle pains, biting force of 10Kg on the gnathodynamometer was maintained by the subjects. And the Bioelectric processor EM2(Myo-Ironies Research, Inc. U.S.A.) with the surface electrodes was used to record the EMG activity during all experimental procedures. The results were as follows; 1. A majority of the present subjects (60%) had a preferred chewing side, but with few exceptions, subjects were unable to explain why a given side was preferred; explanations were only 'comfort' and 'habit' 2. The chewing, or working side was determined largely by the mean voltage of the surface electromyogram (EMG); in comparison with EMG from the non-wlring (contralateral) side, the working (ipsilateral) side showed a higher amplitude. 3. After the effort, the right masseter muscle is the most frequent site of pains, followed by the left masseter muscle, the anterior part of the right temporalis muscle and tile anterior part of the left temporalis muscle. 4. After the effort, mean voltages of masseter muscles were slightly increased, but mean voltages of temporalis anterior were slightly decreased at physiologic rest position. 5. No relationships could be established between preferred chewing side and side of initial muscle pains.

  • PDF

Electrical Stimulation Parameters in Normal and Degenerate Rabbit Retina (정상 망막과 변성 망막을 위한 전기자극 파라미터)

  • Jin, Gye-Hwan;Goo, Yong-Sook
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • Retinal prosthesis is regarded as the most feasible method for the blind caused by retinal diseases such as retinitis pigmentosa (RP) or age related macular degeneration (AMD). Recently Korean consortium launched for developing retinal prosthesis. One of the prerequisites for the success of retinal prosthesis is the optimization of the electrical stimuli applied through the prosthesis. Since electrical characteristics of degenerate retina are expected to differ from those of normal retina, we performed voltage stimulation experiment both in normal and degenerate retina to provide a guideline for the optimization of electrical stimulation for the upcoming prosthesis. After isolation of retina, retinal patch was attached with the ganglion cell side facing the surface of microelectrode arrays (MEA). $8{\times}8$ grid layout MEA (electrode diameter: $30{\mu}m$, electrode spacing: $200{\mu}m$, and impedance: $50k{\Omega}$ at 1 kHz) was used to record in-vitro retinal ganglion cell activity. Mono-polar electrical stimulation was applied through one of the 60 MEA channel, and the remaining channels were used for recording. The electrical stimulus was a constant voltage, charge-balanced biphasic, anodic-first square wave pulse without interphase delay, and 50 trains of pulse was applied with a period of 2 sec. Different electrical stimuli were applied. First, pulse amplitude was varied (voltage: $0.5{\sim}3.0V$). Second, pulse duration was varied $(100{\sim}1,200{\mu}s)$. Evoked responses were analyzed by PSTH from averaged data with 50 trials. Charge density was calculated with Ohm's and Coulomb's law. In normal retina, by varying the pulse amplitude from 0.5 to 3V with fixed duration of $500{\mu}s$, the threshold level for reliable ganglion cell response was found at 1.5V. The calculated threshold of charge density was $2.123mC/cm^2$. By varying the pulse duration from 100 to $1,200{\mu}s$ with fixed amplitude of 2V, the threshold level was found at $300{\mu}s$. The calculated threhold of charge density was $1.698mC/cm^2$. Even after the block of ON-pathway with L-(1)-2-amino-4-phosphonobutyric acid (APB), electrical stimulus evoked ganglion cell activities. In this APB-induced degenerate retina, by varying the pulse duration from 100 to $1200{\mu}s$ with fixed voltage of 2 V, the threshold level was found at $300{\mu}s$, which is the same with normal retina. More experiment with APB-induced degenerate retina is needed to make a clear comparison of threshold of charge density between normal and degenerate retina.

  • PDF