• 제목/요약/키워드: voltage record

검색결과 24건 처리시간 0.024초

배전원격관리를 위한 차세대 디지털 적산전력계 개발 (Development of ADWHM(Advanced Digital Watt-Hour Meter) for Remote Management of Distribution Systems)

  • 고윤석;윤상문;서성진;강태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권6호
    • /
    • pp.316-323
    • /
    • 2004
  • This paper develops an ADWHM(Advanced Digital Watt-Hour Meter) which integrates and implements the voltage management data record function and the load management data record function in the electronic watt-hour meter. ADWHM is developed based on PIC16F874 which is 8bit micro-controller of RISK type for the easy of programing and maintenance, and electronic power signal processing module is located at front of it to reduce the computing load of processor. Also, a 16kbyte EEPROM is used to record the voltage management data and load management data for a week as well as watt-hour data and USART communication mode is used to transfer data from ADWHM to PC. The accuracy of the voltage and unt measuring for ADWHM is verified by identifying the LCD display values of the ADWHM after the voltage signals of id levels from digital function generator is applied to PT(Potential Transformer) and CT(Current Transformer) output under state which it is separated from real power line. On the its basic functions such as watt-hour data recording function, voltage management data recording function and load management data recording function was verified by showing data for three days among the collected data to PC by RS232C communication from ADWHM which was connected to real power lines for a week.

Dual-slope A/D 변환을 이용한 배전선 전압관리용 계측기 개발 (Development of the voltage management recorder using o dual-slope A/D converter for power distribution lines)

  • 손수국
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.38-44
    • /
    • 2002
  • 본 논문에서는 배전선의 전압관리를 위한 계측시스템의 개발에 관하여 제안한다. 배전선 전압특성 및 측정상의 문제점이 분석되고, 전압관리를 위한 계측기의 기능에 대하여 제안한다. 노이즈 특성이 좋은 이중기울기(dual-slope) 방식의 A/D 컨버터를 적용하여 전압측정을 하는 알고리즘과 배전선 전압관리계기의 개발에 관하여 제안한다. IEEE 1159기준 분석에 따른 배전선의 정전 및 복귀 와 규정전압 초과 빈도 수 같은 전압변동 특성 등이 데이터베이스 제안에 의하여 분석된다. 실험을 통하여 그 편리성이 증명된다.

틸팅열차 운행 중 가선전압 계측 및 분석연구 (The Service Voltage Measurement and Analysis while TTX Runs)

  • 이수길;강철;허재선;김재철;임재찬
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.58-65
    • /
    • 2009
  • 최근 한국철도기술연구원이 개발한 한국형 틸팅열차(TTX) "한빛 200"은 현재 호남선, 중앙선, 충북선 그리고 태백선에서 시험 운행 중에 있다. 본 논문은 TTX가 기존선로에서 시험 운행하는 동안 TTX에 공급되는 전압을 계측 하여 각 기존선로에서 공급하는 전압의 상태를 분석하였다. TTX에 공급되는 전압을 직접 계측하기 위해 TTX의 판토그래프 밑단인 부분에 PT를 설치하여 변압기 1차측 전압을 계측하였다. 정확한 분석을 위해 계측 시 TTX외의 다른 열차와 교차 상황과 주변상황에 대해 기록하였으며, CBEMA 커브를 이용하여 가선전압 상태에 대한 분석을 하였다. 그 결과 호남선, 중앙선, 태백선 모두 정격전압(25[kV])의 110[%]이상의 전압이 200[s]이상 공급되는 구역도 있었으며 빈번하게 110[%]를 초과하고 있는 것으로 분석됐다. 특히 태백선의 가선전압의 상태가 가장 좋지 않은 것으로 분석됐다. 이렇게 가선전압 분석결과는 앞으로 중앙선 및 태백선에 상용화될 TTX의 동력장치 및 전력변환장치를 안정화하는데 도움이 될 것으로 사료된다.

수도권 전동열차 노선별 소비전력량 분석 (The Power Consumption analysis of the metropolitan Electric Multiple Unit for a Route)

  • 김진우;손경소;장희주;김호순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.619-626
    • /
    • 2011
  • In this paper, while electric multiple unit is moving on the rail, the content of measuring and analysing electric power consumption is mentioned. In order to measure the electric power consumption, we developed the power record analysis equipment and installed it the inside of the converter and inverter system to record the electric power consumption measured by voltage sensor and current sensor. Moving on the rail, we analysed traction power used up and regenerative power by using the measuring instrument. We expect that the measured and analysed data will offer basic research material to devise a energy reduction plan and introduce a new EMU system with high efficiency.

  • PDF

스폿용접기의 용접품질 향상을 위한 동저항 데이터 베이스 구축 (Implementation of Dynamic Resistance Database for Weld Quality Improvement of Spot Welder)

  • 조승진;김재문;원충연;최규하;김규식;목형수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.143-148
    • /
    • 1998
  • A dynamic electrical parameter monitoring device was designed to simultaneously record the instantaneous value of voltage, current, power, and resistance during spot welding. The data obtained using this technique have been analyzed in term of the relationships of these parameters to the phenomena occuring during the formation(surface break-down, nugget formation and mechanical collapse) of spot weld. Finally, a database implementation is undertaken to develop techniques for improving weld quality of the resistance spot welder.

  • PDF

적응 자동 재폐로 및 고장거리 산정을 위한 새로운 1단자 알고리즘 (A New One Terminal Numerical Algorithm for Adaptive Autoreclosure and Fault Distance Calculation)

  • Zoran Radojevic;Joong-Rin Shin
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.438-445
    • /
    • 2004
  • This paper presents a new numerical spectral domain algorithm devoted to blocking unsuccessful automatic reclosing onto permanent faults and fault distance calculation. Arc voltage amplitude and fault distance are calculated from the fundamental and third harmonics of the terminal voltages and currents phasors. From the calculated arc voltage amplitude it can be concluded if the fault is transient arcing fault or permanent arcless fault. If the fault is permanent automatic reclosure should be blocked. The algorithm can be applied for adaptive autoreclosure, distance protection, and fault location. The results of algorithm testing through computer simulation and real field record are given.

방사선검사에 관한 기록 의무화의 필요성 (Necessity of Mandatory Records on Radiological Examination)

  • 홍동희;임청환;김연민;김은혜;유세종;윤용수;임우택;정영진;정홍량;주영철;최지원;강병삼;박명환;백금문;양오남;임재동;정봉재
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.399-407
    • /
    • 2021
  • This study discussed the validity and necessity of compulsory recording of radiographic examination performed by radiological technologist on patients in medical institutions related to radiation exposure. Also, this study provided reasonable evidence of radiographic examination related medical records can contribute to the improvement of public health. Based on overseas cases of implementing a radiographic examination record system, the essential items to be included in medical record are the exposure date, exposure time, exposure method, exposure conditions that is tube voltage, tube current. Name and license number of the radiological technologist who performed the examination should be include in medical record. It is expected that the medical record of the total amount of radiation exposure per year would be in giving the maximum benefit with the minimum exposure to the medical radiation examination of the patient. In addition, interventional radiography medical record should also include exposure time, type and dose of the contrast medium.

콘크리트 구조물에서의 열전모듈 거동에 관한 기초연구 (Fundamental Study of the Behavior of Thermoelectric Module on Concrete Structure)

  • 임치수;이재준
    • 한국도로학회논문집
    • /
    • 제17권5호
    • /
    • pp.33-38
    • /
    • 2015
  • PURPOSES : The purpose of this paper is to investigate the application of thermoelectric technology to concrete structures for harvesting solar energy that would otherwise be wasted. In various fields of research, thermoelectric technology using a thermoelectric module is being investigated for utilizing solar energy. METHODS: In our experiment, a halogen lamp was used to produce heat energy instead of the solar heat. A data logger was used to record the generated voltage over time from the thermoelectric module mounted on a concrete specimen. In order to increase the efficiency of energy harvesting, various factors such as color, architecture, and the ability to prevent heat absorption by the concrete surface were investigated for the placement of the thermoelectric module. RESULTS : The thermoelectric module produced a voltage using the temperature difference between the lower and upper sides of the module. When the concrete specimen was coated with an aluminum foil, a high electric power was measured. In addition, for the power generated at low temperatures, it was confirmed that the voltage was generated steadily. CONCLUSIONS: Thermoelectric technology for energy harvesting can be applied to concrete structures for generating electric power. The generated electricity can be used to power sensors used in structure monitoring in the future.

Microphone Array와 열화상 카메라를 이용한 고압설비 고장검출 (Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging Camera)

  • 한순신;최재영;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제16권1호
    • /
    • pp.25-32
    • /
    • 2010
  • The paper proposes a hierarchical fault detection method for the high voltage equipment using a microphone array which detects the location of fault and the thermal imaging and CCD cameras which verifies the fault and stores the image, respectively. There are partial arc discharges on the faulty insulators, which generates a specific pattern of sound. Detecting the signal using the microphone array, the location of the faulty insulator can be estimated. The 6th band-pass filter was applied to remove noise signal from wind or external influence. When the mobile robot carries the thermal and CCD cameras to the possible place of the fault insulator, the fault insulators or power transmission wires can be detected by the thermal images, which are caused by the aging or natural erosion. Finally, the CCD camera captures the image of the fault insulator for the record. The detection scheme of fault location using the microphone array and the thermal images have been proved to be effective through the real experiments. As a result of this research, it becomes possible to use a mobile robot with the integrated sensors to detect the fault insulators instead of a human being.

교합기능시 흉쇄유돌근과 교근의 관계에 대한 근전도학적 연구 (AN INTEGRATED EMG STUDY OF THE RELATIONSHIP OF STERNOCLEIDOMASTOID AND MASSETER MUSCLES DURING OCCLUSAL FUNCTION)

  • 김교철;최부병
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.37-52
    • /
    • 1989
  • The purpose of this study was to investigate the relationship between sternocleidomastoid (SCM) and masseter muscles during occlusal functions by means of EMG recordings of examined muscles. For the study, eighteen normal subjects were selected and the Bio-electric Processor EM2 (Myo-tronics Research, Inc., U.S.A.) with the surface electrodes was used to record the EMG activity from the right and left middle of masseter and insertion of SCM of each subject during right and left gum-chewing and isometric contraction by changing the biting force at right eccentric position of jaw. The amount of biting force ranged from 5 to 70kg during isometric contraction were measured by use of Jaw Force Meter. (Nihon Koden Kogyo, Japan.) The results were as follows: 1. The activity onset of SCM and masseter on the same side was almost at the same time, and integrated EMG values of two muscles on the chewing side were higher than the same named muscles on the non-chewing side during gum-chewing. (p<0.01) 2. The regression correlation was not present between both masseters (p>0.05), but between both SCM muscles or muscles of two kinds on the chewing or non-chewing side. ($p{\leqq}0.05$) 3. The integrated EMG value of SCM on chewing or non-chewing side were about 10 percent of that of ipsilateral masseter. 4. Mean voltage of each examined muscles were almost proportional to biting force during isometric contraction and the slope of voltage/biting force line was steepest at the ipsilateral masseter, followed by contalateral masseter, ipsi- and contra-lateral SCM muscles. 5. Mean voltage of ipsilateral masseter was highest during isometric contraction, followed by ipsilateral masseter, contra- and ipsi-lateral SCM muscles.

  • PDF