• Title/Summary/Keyword: voltage record

Search Result 25, Processing Time 0.063 seconds

Development of ADWHM(Advanced Digital Watt-Hour Meter) for Remote Management of Distribution Systems (배전원격관리를 위한 차세대 디지털 적산전력계 개발)

  • 고윤석;윤상문;서성진;강태규
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.6
    • /
    • pp.316-323
    • /
    • 2004
  • This paper develops an ADWHM(Advanced Digital Watt-Hour Meter) which integrates and implements the voltage management data record function and the load management data record function in the electronic watt-hour meter. ADWHM is developed based on PIC16F874 which is 8bit micro-controller of RISK type for the easy of programing and maintenance, and electronic power signal processing module is located at front of it to reduce the computing load of processor. Also, a 16kbyte EEPROM is used to record the voltage management data and load management data for a week as well as watt-hour data and USART communication mode is used to transfer data from ADWHM to PC. The accuracy of the voltage and unt measuring for ADWHM is verified by identifying the LCD display values of the ADWHM after the voltage signals of id levels from digital function generator is applied to PT(Potential Transformer) and CT(Current Transformer) output under state which it is separated from real power line. On the its basic functions such as watt-hour data recording function, voltage management data recording function and load management data recording function was verified by showing data for three days among the collected data to PC by RS232C communication from ADWHM which was connected to real power lines for a week.

Development of the voltage management recorder using o dual-slope A/D converter for power distribution lines (Dual-slope A/D 변환을 이용한 배전선 전압관리용 계측기 개발)

  • 손수국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.38-44
    • /
    • 2002
  • This paper describes the development of a new voltage recorder for the voltage management of power distribution lines. The voltage characteristics and measurement problems for the power distribution lines are analyzed and the functions required for the recorder are discussed. Applying a dual-slope A/D converter with low noise characteristics the voltage measurement algorithm, design and implementation for the recorder are discussed. Finally, the voltage variations of long-duration over-voltages or under-voltages, and short-duration temporary interruption based on IEEE 1159 are analyzed. It is verified with the experiment.

The Service Voltage Measurement and Analysis while TTX Runs (틸팅열차 운행 중 가선전압 계측 및 분석연구)

  • Lee, Su-Gil;Kang, Chul;Her, Jae-Sern;Kim, Jae-Chul;Lim, Jae-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.58-65
    • /
    • 2009
  • Recently, the Korea Tilting Express(TTX), "HANVIT 200", KRRI(Korea Railroad Research Institute) developed runs for test on the conventional railroad, Honam line, Center line, Chunk-buk line and Tae-baek line. In this paper, we measured the service voltage while TTX ran on the conventional railroad and analyzed the condition of voltage. For measuring voltage directly, we installed PT under the pantograph and measured the voltage of the primary winding. In addition, we record situations that other trains pass by TTX and environments while TTX ran. And then we analyzed the condition of voltage using the records and CBEMA curve. In result, over 110[%] voltage of rated voltage(25[kV]) often occurred and the voltage of some place continued over 110[%] for about 200[s]. Especially, the voltage condition of Tae-baek line is the worst. The results in this paper can help to stabilize the power device and power converter of TTX.

The Power Consumption analysis of the metropolitan Electric Multiple Unit for a Route (수도권 전동열차 노선별 소비전력량 분석)

  • Kim, Jin-Woo;Son, Kyong-So;Jang, Hee-Ju;Kim, Ho-Soon
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.619-626
    • /
    • 2011
  • In this paper, while electric multiple unit is moving on the rail, the content of measuring and analysing electric power consumption is mentioned. In order to measure the electric power consumption, we developed the power record analysis equipment and installed it the inside of the converter and inverter system to record the electric power consumption measured by voltage sensor and current sensor. Moving on the rail, we analysed traction power used up and regenerative power by using the measuring instrument. We expect that the measured and analysed data will offer basic research material to devise a energy reduction plan and introduce a new EMU system with high efficiency.

  • PDF

Implementation of Dynamic Resistance Database for Weld Quality Improvement of Spot Welder (스폿용접기의 용접품질 향상을 위한 동저항 데이터 베이스 구축)

  • 조승진;김재문;원충연;최규하;김규식;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.143-148
    • /
    • 1998
  • A dynamic electrical parameter monitoring device was designed to simultaneously record the instantaneous value of voltage, current, power, and resistance during spot welding. The data obtained using this technique have been analyzed in term of the relationships of these parameters to the phenomena occuring during the formation(surface break-down, nugget formation and mechanical collapse) of spot weld. Finally, a database implementation is undertaken to develop techniques for improving weld quality of the resistance spot welder.

  • PDF

A New One Terminal Numerical Algorithm for Adaptive Autoreclosure and Fault Distance Calculation (적응 자동 재폐로 및 고장거리 산정을 위한 새로운 1단자 알고리즘)

  • Zoran Radojevic;Joong-Rin Shin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.8
    • /
    • pp.438-445
    • /
    • 2004
  • This paper presents a new numerical spectral domain algorithm devoted to blocking unsuccessful automatic reclosing onto permanent faults and fault distance calculation. Arc voltage amplitude and fault distance are calculated from the fundamental and third harmonics of the terminal voltages and currents phasors. From the calculated arc voltage amplitude it can be concluded if the fault is transient arcing fault or permanent arcless fault. If the fault is permanent automatic reclosure should be blocked. The algorithm can be applied for adaptive autoreclosure, distance protection, and fault location. The results of algorithm testing through computer simulation and real field record are given.

Necessity of Mandatory Records on Radiological Examination (방사선검사에 관한 기록 의무화의 필요성)

  • Hong, Dong-Hee;Lim, Cheong-Hwan;Kim, Yon-Min;Kim, Eun-Hye;Yoo, Se-Jong;Yoon, Yong-Su;Lim, Woo-Taek;Jung, Young-Jin;Jung, Hong-Ryang;Joo, Young-Cheol;Choi, Ji-Won;Kang, Byung-Sam;Park, Myeong-Hwan;Back, Geum-Mun;Yang, Oh-Nam;Rhim, Jae-Dong;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.399-407
    • /
    • 2021
  • This study discussed the validity and necessity of compulsory recording of radiographic examination performed by radiological technologist on patients in medical institutions related to radiation exposure. Also, this study provided reasonable evidence of radiographic examination related medical records can contribute to the improvement of public health. Based on overseas cases of implementing a radiographic examination record system, the essential items to be included in medical record are the exposure date, exposure time, exposure method, exposure conditions that is tube voltage, tube current. Name and license number of the radiological technologist who performed the examination should be include in medical record. It is expected that the medical record of the total amount of radiation exposure per year would be in giving the maximum benefit with the minimum exposure to the medical radiation examination of the patient. In addition, interventional radiography medical record should also include exposure time, type and dose of the contrast medium.

Fundamental Study of the Behavior of Thermoelectric Module on Concrete Structure (콘크리트 구조물에서의 열전모듈 거동에 관한 기초연구)

  • Lim, Chisu;Lee, Jaejun
    • International Journal of Highway Engineering
    • /
    • v.17 no.5
    • /
    • pp.33-38
    • /
    • 2015
  • PURPOSES : The purpose of this paper is to investigate the application of thermoelectric technology to concrete structures for harvesting solar energy that would otherwise be wasted. In various fields of research, thermoelectric technology using a thermoelectric module is being investigated for utilizing solar energy. METHODS: In our experiment, a halogen lamp was used to produce heat energy instead of the solar heat. A data logger was used to record the generated voltage over time from the thermoelectric module mounted on a concrete specimen. In order to increase the efficiency of energy harvesting, various factors such as color, architecture, and the ability to prevent heat absorption by the concrete surface were investigated for the placement of the thermoelectric module. RESULTS : The thermoelectric module produced a voltage using the temperature difference between the lower and upper sides of the module. When the concrete specimen was coated with an aluminum foil, a high electric power was measured. In addition, for the power generated at low temperatures, it was confirmed that the voltage was generated steadily. CONCLUSIONS: Thermoelectric technology for energy harvesting can be applied to concrete structures for generating electric power. The generated electricity can be used to power sensors used in structure monitoring in the future.

Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging Camera (Microphone Array와 열화상 카메라를 이용한 고압설비 고장검출)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • The paper proposes a hierarchical fault detection method for the high voltage equipment using a microphone array which detects the location of fault and the thermal imaging and CCD cameras which verifies the fault and stores the image, respectively. There are partial arc discharges on the faulty insulators, which generates a specific pattern of sound. Detecting the signal using the microphone array, the location of the faulty insulator can be estimated. The 6th band-pass filter was applied to remove noise signal from wind or external influence. When the mobile robot carries the thermal and CCD cameras to the possible place of the fault insulator, the fault insulators or power transmission wires can be detected by the thermal images, which are caused by the aging or natural erosion. Finally, the CCD camera captures the image of the fault insulator for the record. The detection scheme of fault location using the microphone array and the thermal images have been proved to be effective through the real experiments. As a result of this research, it becomes possible to use a mobile robot with the integrated sensors to detect the fault insulators instead of a human being.

AN INTEGRATED EMG STUDY OF THE RELATIONSHIP OF STERNOCLEIDOMASTOID AND MASSETER MUSCLES DURING OCCLUSAL FUNCTION (교합기능시 흉쇄유돌근과 교근의 관계에 대한 근전도학적 연구)

  • Kim, Kyo-Chul;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.37-52
    • /
    • 1989
  • The purpose of this study was to investigate the relationship between sternocleidomastoid (SCM) and masseter muscles during occlusal functions by means of EMG recordings of examined muscles. For the study, eighteen normal subjects were selected and the Bio-electric Processor EM2 (Myo-tronics Research, Inc., U.S.A.) with the surface electrodes was used to record the EMG activity from the right and left middle of masseter and insertion of SCM of each subject during right and left gum-chewing and isometric contraction by changing the biting force at right eccentric position of jaw. The amount of biting force ranged from 5 to 70kg during isometric contraction were measured by use of Jaw Force Meter. (Nihon Koden Kogyo, Japan.) The results were as follows: 1. The activity onset of SCM and masseter on the same side was almost at the same time, and integrated EMG values of two muscles on the chewing side were higher than the same named muscles on the non-chewing side during gum-chewing. (p<0.01) 2. The regression correlation was not present between both masseters (p>0.05), but between both SCM muscles or muscles of two kinds on the chewing or non-chewing side. ($p{\leqq}0.05$) 3. The integrated EMG value of SCM on chewing or non-chewing side were about 10 percent of that of ipsilateral masseter. 4. Mean voltage of each examined muscles were almost proportional to biting force during isometric contraction and the slope of voltage/biting force line was steepest at the ipsilateral masseter, followed by contalateral masseter, ipsi- and contra-lateral SCM muscles. 5. Mean voltage of ipsilateral masseter was highest during isometric contraction, followed by ipsilateral masseter, contra- and ipsi-lateral SCM muscles.

  • PDF