• 제목/요약/키워드: voltage contrast

검색결과 284건 처리시간 0.027초

액정 표시기의 화질 향상을 위한 중첩구동방식의 최적화에 관한 연구 (A Study on the optimization of overlap scanning method for the enhancement of display quality in LC Displays)

  • 최선정;김용득
    • 전자공학회논문지B
    • /
    • 제32B권10호
    • /
    • pp.1280-1285
    • /
    • 1995
  • In this paper the optimized overlap driving scheme for improving the reduction problem of the operating voltage range occured by the overlap driving scheme proposed precedently and increasing the contrast ratio of screen image in the simple matrix LCDs is proposed. The characteristic estimation of the proposed method was performed in a condition that the number of scan electrodes was 120 and the threshold voltage of LC pixel was 2V and the overlap rate of scan signal was varied from 0% to 40% . As a result of estimation compared with the overlap driving scheme proposed precedently, this new method was certified as a method which it could increase the operating voltage range of the LC pixel by 16% in 20% overlap condition and it's operating voltage range was also increased very much with the increase of the overlap rate. Consequently this newly proposed method was certified as a method which it could maintain the improvement effect of the operating characteristics obtained by the overlap driving scheme proposed precedently with the big improvement in the contrast ratio of screen image.

  • PDF

Ultraviolet Photodetection Properties of ZnO/Si Heterojunction Diodes Fabricated by ALD Technique Without Using a Buffer Layer

  • Hazra, Purnima;Singh, S.K.;Jit, S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권1호
    • /
    • pp.117-123
    • /
    • 2014
  • The fabrication and characterization of a Si/ZnO thin film heterojunction ultraviolet photodiode has been presented in this paper. ZnO thin film of ~100 nm thick was deposited on <100> Silicon (Si) wafer by atomic layer deposition (ALD) technique. The Photoluminescence spectroscopy confirms that as-deposited ZnO thin film has excellent visible-blind UV response with almost no defects in the visible region. The room temperature current-voltage characteristics of the n-ZnO thin film/p-Si photodiodes are measured under an UV illumination of $650{\mu}W$ at 365 nm in the applied voltage range of ${\pm}2V$. The current-voltage characteristics demonstrate an excellent UV photoresponse of the device in its reverse bias operation with a contrast ratio of ~ 1115 and responsivity of ~0.075 A/W at 2 V reverse bias voltage.

The improvement of contrast on LCOS system

  • Chen, Hun-Wei;Wu, Shih-Min;Mo, Chi-Neng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.740-743
    • /
    • 2005
  • The discussion of this study is that we proposed a new construction to improve the potency of LCOS projection monitor. We suggest a new construction that uses special optics coating to reduce the green channel and obtains a purer white field. Compared with the voltage method to adjust on the monitor, we can get higher contrast gradient.

  • PDF

흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究) (Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography)

  • 김정민;김동현;임태랑;석전유치;전전미향;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권1호
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

A New Address-While-Display Driving Method using the $\underline{S}hort\;\underline{R}amp\;\underline{R}eset$ Pulse (SRR) for High Contrast ratio and Wide Address Margin

  • Jung, Jae-Chul;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.631-634
    • /
    • 2005
  • We propose a new address-while-display (AWD) driving method to obtain a high contrast ratio and a wide driving margin which is composed of a short ramp reset period, a sustain period and an address period as the basic unit. The short ramp reset (SRR) pulse made it possible to assure the wide operating voltage margin and minimize the background luminance by redistributing the wall charges between address and scan electrode. As a result, a high dark room contrast ratio of 10000 to 1 could be obtained with a wide operating voltage margin of 40V for stable address.

  • PDF

A Study of New Operation Mode for High Contrast Ratio and Fast Switching Time in Antiferroelectric Liquid Crystal(AFLC)

  • Lim, Tong-Kun;Baek, Do-Hyeon;Shin, Sung-Tae
    • Journal of the Optical Society of Korea
    • /
    • 제5권2호
    • /
    • pp.39-42
    • /
    • 2001
  • A new method of switching mode in AFLC cell is proposed for faster switching time and higher contrast ratio. In this mode the ″dark″ state is obtained by applying negative full voltage while the ″bright″ state is achieved by applying positive full voltage to the cell. The switching time is reduced to 100 $mutextrm{s}$ for the cell whose switching time is 22 ms when operated in conventional mode. The contrast ratio is also improved vastly with this method. The possibility of achieving gray scale was shown in this mode of operation.

Mechanism and Application of NMOS Leakage with Intra-Well Isolation Breakdown by Voltage Contrast Detection

  • Chen, Hunglin;Fan, Rongwei;Lou, Hsiaochi;Kuo, Mingsheng;Huang, Yiping
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권4호
    • /
    • pp.402-409
    • /
    • 2013
  • An innovative application of voltage-contrast (VC) inspection allowed inline detection of NMOS leakage in dense SRAM cells is presented. Cell sizes of SRAM are continual to do the shrinkage with bit density promotion as semiconductor technology advanced, but the resulting challenges include not only development of smaller-scale devices, but also intra-devices isolation. The NMOS leakage caused by the underneath n+/P-well shorted to the adjacent PMOS/N-well was inspected by the proposed electron-beam (e-beam) scan in which VC images were compared during the in-line process step of post contact tungsten (W) CMP (Chemical Mechanical Planarization) instead of end-of-line electrical test, which has a long response time. A series of experiments based on the mechanism for improving the intra-well isolation was performed and verified by the inline VC inspection. An optimal process-integration condition involved to the tradeoff between the implant dosage and photo CD was carried out.

전폴리머 조성에 따른 고분자 분산형 액정의 전기 광학 특성 평가 (Electro-Optical Characterization of Polymer Dispersed Liquid Crystals for Various Concentrations of Prepolymer)

  • 양기정;윤도영
    • 한국전기전자재료학회논문지
    • /
    • 제23권11호
    • /
    • pp.891-895
    • /
    • 2010
  • Polymer dispersed liquid crystal (PDLC) films were prepared by the phase separation method using the liquid crystal (E7) and prepolymers. This work investigated the electro-optical characteristics of various PDLC films. In order to have good contrast ratio, the polymer refractive index must be adjusted to the ordinary refractive index of the liquid crystal. The driving voltage of PDLC films were mainly affected by elastic deformation. E7-Ebecryl810-IOA-TMPTA-HMPPO system had good threshold voltage and driving voltage and E7-Ebecryl810-EHA-PEGDA-HMPPO system had good contrast ratio.

액정표시 장치에서 영상에 따른 콘트라스트 제어 방법 (A Method for Contrast Enhancement according to Video image in Liquid Crystal Display)

  • 박행원;전병우;이승우;김영기
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.477-480
    • /
    • 2003
  • This paper describes a novel method for image contrast enhancement by controlling gamma curve in AMLCD. The key idea is to automatically manipulate gamma voltage in accordance with the image data distribution. This method is applied to 17" SXGA LCD monitor module. The contrast ratio and the brightness are enhanced respectively by about 3 times and 1.7 times, by using the proposed method.

  • PDF

증감지에 따른 피사체 대조도의 변화 (Effect of Intensifying Screens to Subject Contrast)

  • 이인자;허준;강홍석;윤철호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제13권2호
    • /
    • pp.27-30
    • /
    • 1990
  • It is an experimental report about object contrast according to the Kinds of screen and obtained results as follows : 1. In the same object radiography, use acquired the difference of the object contrast between LT-II ($CaWO_{4}\;system$) and G4 (Gd system) screens. 2. object contrast more decreased in Gd system screen than $CaWO_{4}$, and object contrast controlled by X-ray tube voltage. 3. The difference of object contrast seen clearly in 80 kVp.

  • PDF