• 제목/요약/키워드: void diameter

검색결과 97건 처리시간 0.037초

2중관형 2상 열사이폰의 한계열유속 특성에 관한 연구 (A Study on Critical Heat Elux Characteristics in a Two-Phase Concentric-Tube Thermosyphon)

  • 김욱
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1419-1426
    • /
    • 2002
  • An experimental study was made to elucidate critical heat flux(CHF) characteristics in a two-phase concentric-tube thermosyphon. The experiment was performed by using saturated water, over the experimental range of configuration: inner diameter of heated outer tube D=12mm, outer diameter of unheated inner tube do=3 to 10mm and heated tube length L=100 to 1000mm. The experiment shows that the CHF is enhanced with increase in the inner tube diameter, and that the CHF decreases beyond a certain diameter of the inner tube. There is an optimum diameter for inner tube that maximizes the CHF, for each tube length and test liquid. The CHF maximum is about two to eight times as large as that without an inner tube. For a large inner tube, the CHF characteristics is similar to that for natural convective boiling in a vertical annular tube.

기-액(氣-液) 2상유동(二相流動)시 항력(抗力)에 관(關)한 연구(硏究) (The Study on the Drag Reduction for Gas/Liquid Two Phase Flow)

  • 차경옥;오율권;김재근
    • 한국분무공학회지
    • /
    • 제1권3호
    • /
    • pp.20-28
    • /
    • 1996
  • It is well known that drag reduction in single phase liquid flow is affected by polymer material, molecular weight, polymer concentration, pipe diameter, and flow velocity. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to present cavitation which occurs in pump impellers. But the research of drag reduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction whether polymer is added in the horizontal two phase system or not. Experiment has been conducted in a test section with 24 m of the inner diameter and 1,500 mm of the length. The used polymer materials are two kinds of polyacrylamide[PAAM] and co-polymer[A611P]. The polymer concentration was varied with 50, 100 and 200 ppm under the same experimental conditions. Experimental results were shown that the drag is higher reduced by co-polymer rather than polyanylamide.

  • PDF

고분자물질(高分子物質) 첨가(添加)에 따른 마찰저항감소(摩擦抵抗減少)에 관한 연구(硏究) (A Study on the Drag Reduction with Polymer Additives)

  • 김재근;차경옥;최형진;김종보
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.198-207
    • /
    • 1996
  • It is well known that drag reduction in single phase liquid flow is affected by polymer material, molecular weight, polymer concentration, pipe diameter, and flow velocity. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to present cavitation which occurs in pump impellers. But the research of drag reduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction, mean liquid velocity, and turbulent intensity whether polymer is added in the horizontal two phase system or not. Experiment has been conducted in a test section with the inner diameter of 24mm and the length of 1,500mm. The polymer materials used are two kinds of polyacrylamide[PAAM] and co-polymer[A611P]. The polymer concentration was varied with 50, 100 and 200 ppm under the same experimental conditions. Experimental results showed that the drag reduction of co-polymer is higher than that of polyacrylamide. Mean liquid velocities increased as polymer was added, and turbulent intensity decreased inversely near the pipe wall.

  • PDF

Improvement of the MARS subcooled boiling model for a vertical upward flow

  • Ha, Tae-Wook;Jeong, Jae Jun;Yun, Byong-Jo
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.977-986
    • /
    • 2019
  • In the thermal-hydraulic system codes, such as MARS and RELAP5/MOD3, the Savannah River Laboratory (SRL) model has been adopted as a subcooled boiling model. It, however, has been shown that the SRL model cannot take into account appropriately the effects of inlet liquid velocity and hydraulic diameter on axial void fraction development. To overcome the problems, Ha et al. (2018) proposed a modified SRL model, which is applicable to low-pressure and low-Pe conditions (P < 9.83 bar and $Pe{\leq}70,000$) only. In this work, the authors extended the modified SRL model by proposing a new net vapor generation (NVG) model and a wall evaporation model so that the new subcooled boiling model can cover a wide range of thermal-hydraulic conditions with pressures ranging from 1.1 to 69 bar, heat fluxes of $97-1186kW/m^2$, Pe of 3600 to 329,000, and hydraulic diameters of 5-25.5 mm. The new model was implemented in the MARS code and has been assessed using various subcooled boiling experimental data. The results of the new model showed better agreements with measured void fraction data, especially at low-pressure conditions.

중공 입자의 제조: 반응 인자가 평균 입자 크기와 고형분 함량에 미치는 영향 (Preparation of Void Latex Particles: Effects of Reaction Parameters on the Mean Particle Diameter and the Solid Content)

  • 이기정;서경원;목영일
    • 공업화학
    • /
    • 제9권5호
    • /
    • pp.758-762
    • /
    • 1998
  • 유화중합을 이용하여 중량 평균입자크기가 $0.3{\mu}m{\sim}1.5{\mu}m$인 중공 라텍스 입자를 제조함에 있어 평균입자크기와 고형분 함량에 영향을 미치는 반응 인자를 조사하였다. 실험결과 유화제 (SDS)의 농도가 증가함에 따라 친수성 코어 폴리머의 크기가 작아졌으며, 친유성 스티렌 단량체 (styrene monomer)와 개시제 (SPS)의 첨가량이 증가함에 따라 중공입자의 크기가 커졌다. 한편, 친수성 아크릴산의 첨가속도가 증가함에 따라 중공입자의 크기가 작아졌다. 또한, 스틸렌 단량체의 첨가량이 증가함에 따라 에멀젼 폴리머의 고형분 함량이 선형적으로 증가하였다.

  • PDF

Active Infrared Thermography for Visualizing Subsurface Micro Voids in an Epoxy Molding Compound

  • Yang, Jinyeol;Hwang, Soonkyu;Choi, Jaemook;Sohn, Hoon
    • 비파괴검사학회지
    • /
    • 제37권2호
    • /
    • pp.106-114
    • /
    • 2017
  • This paper presents an automated subsurface micro void detection technique based on pulsed infrared thermography for inspecting epoxy molding compounds (EMC) used in electronic device packaging. Subsurface micro voids are first detected and visualized by extracting a lock-in amplitude image from raw thermal images. Binary imaging follows to achieve better visualization of subsurface micro voids. A median filter is then applied for removing sparse noise components. The performance of the proposed technique is tested using 36 EMC samples, which have subsurface (below $150{\mu}m{\sim}300{\mu}m$ from the inspection surface) micro voids ($150{\mu}m{\sim}300{\mu}m$ in diameter). The experimental results show that the subsurface micro voids can be successfully detected without causing any damage to the EMC samples, making it suitable for automated online inspection.

VOID DEFECTS IN COBALT-DISILICIDE FOR LOGIC DEVICES

  • Song, Ohsung;Ahn, Youngsook
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.389-392
    • /
    • 1999
  • We employed cobalt-disilicide for high-speed logic devices. We prepared stable and low resistant $CoSi_2$ through typical fabrication process including wet cleaning and rapid thermal process (RTP). We sputtered 15nm thick cobalt on the wafer and performed RTP annealing 2 times to obtain 60nm thick $CoSi_2$. We observed spherical shape voids with diameter of 40nm in the surface and inside $CoSi_2$ layers. The voids resulted in taking over abnormal junction leakage current and contact resistance values. We report that the voids in $CoSi_2$ layers are resulted from surface pits during the ion implantation previous to deposit cobalt layer. Silicide reaction rate around pits was enhanced due to Gibbs-Thompson effects and the volume expansion of the silicidation of the flat active regime trapped dimples. We confirmed that keeping the buffer oxide layer during ion implantation and annealing the silicon surface after ion implantation were required to prevent void defects in CoSi$_2$ layers.

  • PDF

Experimental investigation on bubble behaviors in a water pool using the venturi scrubbing nozzle

  • Choi, Yu Jung;Kam, Dong Hoon;Papadopoulos, Petros;Lind, Terttaliisa;Jeong, Yong Hoon
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1756-1768
    • /
    • 2021
  • The containment filtered venting system (CFVS) filters the atmosphere of the containment building and discharges a part of it to the outside environment to prevent containment overpressure during severe accidents. The Korean CFVS has a tank that filters fission products from the containment atmosphere by pool scrubbing, which is the primary decontamination process; however, prediction of its performance has been done based on researches conducted under mild conditions than those of severe accidents. Bubble behavior in a pool is a key parameter of pool scrubbing. Therefore, the bubble behavior in the pool was analyzed under various injection flow rates observed at the venturi nozzles used in the Korean CFVS using a wire-mesh sensor. Based on the experimental results, void fraction model was modified using the existing correlation, and a new bubble size prediction model was developed. The modified void fraction model agreed well with the obtained experimental data. However, the newly developed bubble size prediction model showed different results to those established in previous studies because the venturi nozzle diameter considered in this study was larger than those in previous studies. Therefore, this is the first model that reflects actual design of a venturi scrubbing nozzle.

입자층(粒子層)을 이용한 열교환기(熱交換器) 개발(開發)에 관한 연구(硏究)(III) -고정층(固定層) 열교환기(熱交換器) 내(內)에서의 압력손실(壓力損失)에 관(關)한 연구(硏究) (Development of a Particle Bed Heat Exchanger (III) -An Experimental Study on Pressure Drop in Fixed Bed Heat Exchanger)

  • 양한주;서정윤
    • 설비공학논문집
    • /
    • 제2권3호
    • /
    • pp.226-233
    • /
    • 1990
  • Fixed bed is known to be an effective heat transfer augmentation device which could be applied to heat exchangers. In this study, pressure drop in vertical cylindrical and annular fixed beds with air flowing through was experimentally investigated. Based on the experimental data and some analytical considerations, the demensionless correlation of pressure drop has been determined and shown in empirical forms. In particular, the experimental equation for the pressure drop was derived using the particle diameter and the bed diameter as variables, which would be more practical and useful in the design of heat transfer devices, instead of void fraction which had been used previously as the major variables by others. The present empirical equation obtained for the cylindrical fixed bed were found to be applicable also to an annular fixed bed when the concept of effective diameter was introduced.

  • PDF

A Mechanistic Critical Heat Flux Model for High-Subcooling, High-Mass-Flux, and Small-Tube-Diameter Conditions

  • Kwon, Young-Min;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.17-33
    • /
    • 2000
  • A mechanistic model based on wall-attached bubble coalescence, previously developed by the authors, was extended to predict a vow high critical heat flux (CHF)in highly subcooled flow boiling, especially for high mass flux and small tube diameter conditions. In order to take into account the enhanced condensation due to high subcooling and high mass velocity in small diameter tubes, a mechanistic approach was adopted to evaluate the non-equilibrium flow quality and void fraction in the subcooled water flow boiling, with preserving the structure of the previous CHF model. Comparison of the model predictions against highly subcooled water CHF data showed relatively good agreement over a wide range of parameters. The significance of the proposed CHF model lies in its generality in applying over the entire subcooled flow boiling regime including the operating conditions of fission and fusion reactors.

  • PDF