• Title/Summary/Keyword: visual measurement

Search Result 930, Processing Time 0.028 seconds

Analysis of changes in ocular function according to beats per minute (BPM) (분당비트수(BPM)에 따른 안기능 변화 분석)

  • Bong-Hwan Kim;Sun-Hee Han;Chan-heum Kang;Hyeon-seok Lee;Dong-uk Kwon;Chae-won Park;Hyung-Soo Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1639-1643
    • /
    • 2023
  • Purpose. We wanted to find out how the changes in brain function affected by the beats per minute (BPM) of music affected visual function. Methods. The subjects were 40 people in their 20s (30 men, 10 women) with no eye disease, strabismus, amblyopia and a corrected visual acuity of 1.0 or higher. Wearing headphones while excluding surrounding noise as much as possible, we played music while adjusting the beat rate at 40 BPM intervals from 80 to 200 BPM. Then, pupil size measurement, lag of accommodation test, and minus lens addition method maximum accommodation test were performed and analyzed. Results. As a result of analyzing changes in visual function according to beats per minute [BPM], it was found that although sound can be consciously affected, it does not directly affect visual function significantly in terms of accommodative lag and changes in pupil size. It was confirmed that the effect was limited to the maximum accommodation. Conclusions. In clinical practice, it is necessary to conduct a refraction test while keeping in mind that there are changes in visual function depending on the BPM of surrounding sounds.

Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device (방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발)

  • Dong-Sik Jin;Kyeong-Ryeong Kim;Jae-Geun Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

The Relationship between Visual Analogue Scale and R(III) Nociceptive Flexion Reflex (Visual Analogue Scale과 R(III) Nociceptive Flexion Reflex와의 상관관계)

  • Kim, Yong-Ik;Kim, Sang-Hyun;Lee, Ju-Chul;Jeon, Jae-Soo;Hwang, Kyung-Ho;Park, Wook
    • The Korean Journal of Pain
    • /
    • v.13 no.2
    • /
    • pp.175-181
    • /
    • 2000
  • Background: Pain is often measured using psychophysical scaling techniques. However, all of these methods found their limits, since they were based on the subjective sensations reported by the subjects. It is, therefore, desirable to validate psychophysical pain measures by simultaneously measuring some physiological correlate of nociception. We studied an objective method for measuring pain in human volunteer using R(III) nociceptive flexion reflex. Methods: Four different intensity of electrical stimuli between perception and 1.4 times the R(III) nociceptive flexion threshold were delivered to the sole of the feet in 8 normal volunteers. We measured the flexion reflex activity in the skin over the ipsilateral tibialis anterior muscle and subjects rated each stimulus on a visual analog scale (VAS) Results: Both R(III) nociceptive flexion reflex activity and VAS ratings showed a linear relationship with stimulus intensity and with each other in all volunteers. Conclusions: R(III) nociceptive flexion reflex elicited through electrical stimulation may used as an objective pain measurement, previsionary based on our study paradigm.

  • PDF

A Study on Development of Visual Navigational Aids to improve Maritime Situation Awareness (해상상황인식 개선을 위한 시각적 항해보조장비 개발에 관한 연구)

  • Kim, Eun-Kyung;Im, Nam-Kyun;Han, Song-Hee;Jeong, Jung-Sik
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.379-385
    • /
    • 2012
  • This paper developes the navigation visual aid supporting a watch officer's situation awareness and analyzes its performance test result. Developing the equipment made from composite video sensor which transfer video signal, ranger laser measurement model which search out distance, Pan/ Tilt, center control device. The developed equipment with Pan/Tilt was made from high performance video sensor and ranger laser measurement. To make a real ship test, we carried on setting the developed equipment on ship, observed a danger factor and analyzed a image, and from that we can evaluate marine environment awareness. Through this result, the developed equipment can show effective ability of the awareness of the clearer check and resolution situation when compare with the binocular.

Convergence Study on Usability of Music Streaming App UX Design (음악 스트리밍 앱 UX디자인의 사용성에 대한 연구 -멜론, 유튜브 뮤직, 지니, FLO앱을 중심으로)

  • Chun, Seung-Jae;Park, Jin-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.2
    • /
    • pp.135-146
    • /
    • 2021
  • In this study, in order to provide an app with improved usability to users in the trend of gradually increasing the number of users of music streaming services, usability tests were conducted by conducting interviews before and after the execution of the screen test technique and the performance measurement method and contextual. Usability test was conducted using the Inquiry method. Usability tests were conducted by one user each from their teens to their 50s, and were conducted on Melon, YouTube Music, Genie, and FLO apps with many service users. As a result of the usability test, the icon does not sufficiently represent the function and is not recognized as an interactive button, which is overlooked by the user, the problem that the user does not recognize due to lack of visual effect when the function is activated, The problem was derived. In this regard, suggestions for improving the user screen, such as intuitively changing the icon for each app, adding a visual effect of the screen when the function is activated, and adjusting the position so that the function has continuity, were presented along with the visual data.

Development of Eyes Inspection Questionnaire(EIQ) and Regression Analysis between EIQ Items and deficiency or excess patterns of Eyes Inspection (안진(眼診) 설문지 개발 및 안진(眼診) 설문의 허실(虛實) 연관성 연구)

  • Seo, Jae-Ho;Choi, Jin-Yong;Oh, Whan-Sup;Park, Young-Bae;Park, Young-Jae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.18 no.2
    • /
    • pp.75-84
    • /
    • 2014
  • Objectives Eyes, one of visual inspection regions, present important clues to pathological patterns including deficiency and excess patterns to the clinicians. The purpose of this study was to develop Eyes Inspection Questionnaire (EIQ) and to examine which items among the EIQ were more predictive of clinicians' determination for the deficiency and excess patterns. Methods Nine questionnaire items for Visual Inspection of Eyes were extracted through the literature review. These items were presented to the 4 Korean medical doctors who are specialized in visual inspection to conduct the Delphi method. The Korean medical doctors were asked to rate the importance of each items for the corresponding Visual Inspection of Eyes, using a Likert 5-point scale(the 3 points of importance as a cut-off point). Then, out of 75 photographs submitted to the Society of HyungSang Medicine in 2009, 30 portrait pictures were selected as samples. The samples were copied to make 60 sample pictures, and then randomly assigned to 4 clinicians. The 4 clinicians evaluated the 60 samples for excess and deficiency of the eyes and were asked to check the 6 questionnaire items. The results were recorded as 5-points-scale, and their average and standard deviations were calculated. Intra- class reliability test and multi regression test were performed using SPSS 13. Results Intra-class correlation coefficient (ICC) was between 0.750 to 0.841 (P<0.05). Indices for visual inspection of the eyes were: endowment of the bone structure around the eyes; brightness of the eyes; upward deviation of the eyes; eye shapes; and definition of iris. 76.92% of deficiency symptom patterns and 86.42% of the excess symptom patterns matched the patterns predicted by the visual inspection of the eyes, according to the frequency analysis. According to the multiple regression analysis, were significantly related to the excessive symptoms, and to the deficiency symptoms. Conclusion This study is the first attempt of development for checklist of excess and deficiency of Visual Inspection of Eyes and quantitative measurement of excess and deficiency using the Visual Inspection of Eyes by the visual inspection experts. Still, additional studies are needed regarding the relationship visual inspection methods have with existing standards of diagnosis.

Landscape Value Analysis of Hallyǒ Haesang Sea National Park (한려해상국립공원(閑麗海上國立公園)의 경관자원(景觀資源) 가치분석(價値分析))

  • Kim, Sei-Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.145-160
    • /
    • 2000
  • This study is focused to the national park of Korean typical Sea Hally$\check{o}$ Haesang, and its visual resources and practiced inspect course by the way of suppositions and tests, to show the visual resource management objectively, and that of qualitative basic data. Accordingly by measuring the physical amount spatial structure with the visual amount originated from the Mesh Analyzing Method and the Visual Preference from the Scenic Beauty Estimation(S.B.E.) method and analyzed the valuation of the visual resource by Iverson method. Spatial image structure measured by Semantic Differential(S.D.) Scale was shown through the factor analysis algorithm for the analyzing psychological amount and examined the flowing out of decisive factor and the objective importance related to the mutual factors by appling the measurement of the visual quality. As a national Park, the visual factors that have natural landscape harmonized with forest, sky, surface of the water, curious stones and rocks, and temples should be escalated their values affirmatively so as to be the scenery of pointed direction and enjoyable, and it is of more needed for visual resource and its' controlling technique to make artificial structures more intentional planning and systemical setting. When we are viewing the improvement for the national park along with the visual resource management, reasonable level of development is needed, because when men interference surpass plantations and leasts will be damaged and the quality of natural landscape can be lowered, so it is needed to set up a management end, tangibly or clearly; and it is permitted limit coming and going ablably by accounting the suitable number for availing. But the controling end should be set in every level, positive management, very actively within the permissive varcability. It is the main business for the national park to prevent the damage from human for their gay life or to prevent the damage of a land carpet, and to restorate for the visual resource management.

  • PDF

Excellent Moving Picture Resolution of PDP, Proved by the New Measurement System Developed by the APDC

  • Kawahara, I.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1685-1687
    • /
    • 2007
  • Excellent moving picture performance of plasma TV has been confirmed through the study and measurement using the method proposed by the APDC (Advanced PDP Development Center Corporation). Full-HD Plasma TVs with pixels of $1920{\times}1080[1]-[2]$, showed more than 900 TV-lines of resolution out of maximum scale of 1080, while typical LCD of the same pixel count showed only 1/3 of the plasma's performance. Moreover, even the latest 120Hz models of $1920{\times}1080$ LCD do not much PDPs with pixels of $1024{\times}768$, or $1366{\times}786$ in moving picture resolution. The measurement system proposed by the APDC showed very good agreement with subjective tests.

  • PDF

A study on measurement of curvature radius by the using of laser Interferometer (레이저 간섭계를 이용한 곡률반경 측정에 관한 연구)

  • 김수용;이승수;박재덕;송영철;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.920-924
    • /
    • 2003
  • This paper on measurement of curvature radius by the using of laser interferometer and prove. Mean value compared of ball and bearing It is developed program for date creation, and the verification using program. Measurement object center and curvature radius taking of LSC. when it is compared bearing prove with ball prove, the bearing prove can not proper by reason of big uncertainty and If laser setting error decrease, curvature radius get precision radius 10$\^$-5/.

  • PDF

The Merging Method of Point Data with Point Pattern Matching in 3D Measurement (3차원 형상측정에서 점 패턴매칭을 이용한 점 데이터의 결합방법)

  • 조택동;이호영;양상민
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.714-719
    • /
    • 2003
  • We propose a measuring method of large object using the pattern matching. It is hard and expensive to get the complete 3D data when the object is large and exceeds the limit of measuring devices. The large object is divided into several smaller areas and is scanned several times to get the data of all the pieces. These data are aligned to get the complete 3D data using the pattern matching method such as point pattern matching method and transform matrix algorithm. The laser slit beam and CCD camera are applied for the experimental measurement. Visual C++ on Windows 98 is implemented in processing the algorithm.