• 제목/요약/키워드: visible diagnosis

검색결과 107건 처리시간 0.034초

형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성 (Characterization of the a-Se Film for Phosphor based X-ray light Modulator)

  • 강상식;박지군;조성호;차병열;신정욱;이건환;문치웅;남상희
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

정상 성인 족부 방사선 사진에서 족근 중족 관절 선열 형성 빈도 및 정상 변이 (Normal Variation and Incidence of Coincided Alignment on Lisfranc Joint on Normal Foot Radiography)

  • 강충남;김종오;고상훈
    • 대한족부족관절학회지
    • /
    • 제1권1호
    • /
    • pp.43-50
    • /
    • 1997
  • The tarsometatarsal joint complex is formed by articulation of the five metatarsal bases with the three cuneiform bones and the cuboid bone. Fracture-dislocation of tarsometatarsal area are difficult to recognize on standard radiographs. The exact diagnosis is occasionally delayed. As a result, improper treatment and late sequelae remains. We decided to make a study of patients with normal foot radiographs on 200 cases. Standard radiographic evaluation was used to study the normal variants of the foot and to evaluate the coincided alignment of the lisfranc joint. Accurate accessment on AP & lateral & $30^{\circ}$ oblique projection of radiographs are very adventageous & important, and next final outcome was detected. : 1. Coincided alignment below 1mm and unfolded lisfranc joint on AP projection was well visalized on 1st cuneiform-metatarsal lateral border and 2nd cuneiform-metatarsal medial border. 2. Coincided alignment below 1mm and unfolded lisfranc joint on oblique projection was well visualized on 2nd cuneiform-metatarsal lateral border and 3rd cuneiform-metatarsal medial border and 3rd cuneform-metatarsal lateral border. 3. More proximal location of 2nd lisfranc joint compared to another joint was 196 cases (98%). It is due to inceleration of 2nd metatarsal base between 3rd & 1st cuneiform. 4. 3rd lisfranc joint was volarward position compared to 2nd listranc on lateral projection at 191 cases (95.5%). It's due to anterior covexity of lisfranc joint. 5. Wide dorsal sided 2nd lisfranc is investigated at 189 cases (94.5%). Because of it. 2nd & 3rd lisfrances are mainly volar dislocated usually. 6. Notching on 5th metatarsal base is visible on 171 cases (85.5%). 7. 4th lisfranc joint had offset normally within $2\sim3mm$ at 98 cases (49%). 8. 5th Lisfranc joint had normally offset within $2\sim3mm$ at 99 cases (49.5%). 9. On lateral projection, slight dorsal location of cuneiform to metatarsal base is investigated at 82 cases (41%).

  • PDF

비디오 흉강경을 이용한 자연성 기흉 수술 (Video Assisted Thoracic Surgery of Spontaneous Pneumothorax)

  • 류지윤;김승우;조광현
    • Journal of Chest Surgery
    • /
    • 제30권5호
    • /
    • pp.512-516
    • /
    • 1997
  • 자연성 기흉은 흉부외과 영역에서 흔히 접하게되는 질환으로 대부분의 경우 폐쇄식 흉강삽관술로 잘 치료 되지만 높은 재발율과 지속적인 공기누출로 인한 폐의 팽창부전등의 이유로 개흉술을 시행해야 하는 경우가 많다. 이러한 경우 개흉술로 인한 수술후 통증, 창상감염, 큰 절개흉터등의 문제가 남게되는데 이러한 문제를 해결하는데 효과적인 비디오 흉강경 수술이 현재 각광을 받고 있다. 본 인제대학교 부산백병원 흉부외과학 교실에서는 최근 3년간 자연성 기흉 환자 66명에 대해 비디오 흉강 경을 이용한 수술을 시행하여 다음과 같은 결과를 얻었다. 남녀 비는 63:3으로 남자가 절대적으로 많았으며 연령별로는 10대후반이 36명으로 전체의 55%를 차지하였다. 발생부위는 우측이 30례, 좌측이 36례 였으며 내원시 임상증상은 흉통, 호흡곤란, 흉부 불쾌감 순이였다. 수술적응증으로는 재발성이 36례로 대부분을 차지하였고 기흉 발생후 흉부 X-선상에서 기포가 보인 경우가 15례 였으며 흉관 삽관후 지속적인 공기 누출로 폐 팽창이 않된 경우가 10례였으며, 환자 본인이 수술을 원 하였던 경우가 5례였다. 기포를 포함한 폐부분 절제술을 시행한 경우\ulcorner 2례였고 폐부분 절제술과 더불어 늑막유착술을 동시에 시 행한 경우가 59례로 대부분을 차지하였다. 명백하게 폐기포를 발견할 수 없었던 5례에서는 늑막유착술만을 시행하였다 슬후 합병증은 4례에서 재발성 기흉이 발생하였고 무기폐와 폐렴 Ifl, 투관침 삽관부위 출혈이 1례 발생하였으나 모두 적절한 치료로 해결되었다. 흉강경을 이용한 자연성 기흉 수술은 여러 가지 장점이 많은 효과적인 수술방법으로 사료되어지며 기타 다른 흉부질환에 있어서도 그 적응증이 더욱 늘어나고 앞으로 더욱 발전될 전망이다.

  • PDF

MRI 영상의 PSNR 평가 (PSNR Appraisal of MRI Image)

  • 강광수;이준행
    • 한국방사선학회논문지
    • /
    • 제3권4호
    • /
    • pp.13-21
    • /
    • 2009
  • MRI System은 각종 여러 가지 Parameter들로 구성되어 있다. 그중 MRI 영상의 화질을 빼놓고 MRI를 논한다는 것은 어려운 일이다. 각종 Parameter들이 개발되고 발전되어오면서 MRI영상에서도 예전 System에서 보여지는 영상과는 비교 할 수 없을 정도의 고화질을 출력하고 있다. 그리고 방사선 영상 System이 고식적인 Film방식에서 digital방식으로 전환되어가고 있고 그에 따른 병원의 모든 시스템이 전산화가 되어가고 있다. 방사선 영상의 관리에 있어서 저장 이라는 부분이 아주 중요한 ��을 차지하고 있다. 그 방대한 자료를 Server에 저장하는 방법으로는 압축을 이용 하여 저장하는 방법을 사용하게 된다. 이 때 발생한 문제점은 원본 영상에 비해 압축시 영상의 화질 저하가 발생한다는 것이다. 의료 영상에서는 조그마한 화질저하도 오진의 우려가 있으므로 각별히 주의해야할 사항이다. 본 논문에서는 병원에서 진료중인 영상을 대상으로 각각의 파일 변환과 원본과의 비교, 원본 영상과 진료에 사용되어지는 모니터에서의 MRI 영상의 화질을 PSNR을 이용한 평가와 영상 평가방법에 의한 평가를 하였다. 실험결과 원본과 각종 영상 압축방법을 이용하여 압축한 영상을 비교 분석 하였는데 화질저하가 거의 나타나지 않았다. 하지만 원본영상을 display하는 모니터의 화질 에서 상당한 문제점이 드러났다. 판독용 모니터 와 의료용 모니터에서는 손색없는 고해상도의 영상을 출력해 냈는가 반면 일반 CRT, LCD 모니터에서는 각종 노이즈, 영상왜곡등 많은 문제점들이 나타났다.

  • PDF

Contrast reference values in panoramic radiographic images using an arch-form phantom stand

  • Shin, Jae-Myung;Lee, Chena;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • 제46권3호
    • /
    • pp.203-210
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate appropriate contrast reference values (CRVs) by comparing the contrast in phantom and clinical images. Materials and Methods: Phantom contrast was measured using two methods: (1) counting the number of visible pits of different depths in an aluminum plate, and (2) obtaining the contrast-to-noise ratio (CNR) for 5 tissue-equivalent materials (porcelain, aluminum, polytetrafluoroethylene [PTFE], polyoxymethylene [POM], and polymethylmethacrylate [PMMA]). Four panoramic radiographs of the contrast phantom, embedded in the 4 different regions of the arch-form stand, and 1 real skull phantom image were obtained, post-processed, and compared. The clinical image quality evaluation chart was used to obtain the cut-off values of the phantom CRV corresponding to the criterion of being adequate for diagnosis. Results: The CRVs were obtained using 4 aluminum pits in the incisor and premolar region, 5 aluminum pits in the molar region, and 2 aluminum pits in the temporomandibular joint (TMJ) region. The CRVs obtained based on the CNR measured in the anterior region were: porcelain, 13.95; aluminum, 9.68; PTFE, 6.71; and POM, 1.79. The corresponding values in the premolar region were: porcelain, 14.22; aluminum, 8.82; PTFE, 5.95; and POM, 2.30. In the molar region, the following values were obtained: porcelain, 7.40; aluminum, 3.68; PTFE, 1.27; and POM, - 0.18. The CRVs for the TMJ region were: porcelain, 3.60; aluminum, 2.04; PTFE, 0.48; and POM, - 0.43. Conclusion: CRVs were determined for each part of the jaw using the CNR value and the number of pits observed in phantom images.

업컨버전 나노입자를 이용한 광역학치료 연구 동향 (Recent Trends in Photodynamic Therapy Using Upconversion Nanoparticles)

  • 임세진;이송렬;박용일
    • 공업화학
    • /
    • 제29권2호
    • /
    • pp.138-146
    • /
    • 2018
  • 광역학치료는 질병을 치료함에 있어 전이가능성과 부작용이 매우 적고 국부적인 종양의 제거가 가능하다는 장점을 갖는 치료방법이다. 광역학치료에서는 빛 에너지를 흡수하여 세포 독성을 띠는 활성산소를 생성하는 감광제가 필수적이다. 하지만 일반적인 감광제는 가시광선을 광원으로 사용하므로 이에 따른 부작용 및 치료효과의 한계가 존재한다. 이러한 이유로 가시광선 대신 근적외선을 광원으로 사용할 수 있는 업컨버전 나노입자가 질병진단 및 치료 분야에서 주목을 받고 있다. 업컨버전 나노입자는 세포 독성 및 광원에 의한 부작용이 적고, 광원의 조직 내 높은 투과율 및 낮은 자가형광 등의 장점을 가지고 있다. 근적외선 업컨버전을 광역학치료에 활용하기 위해서는 근적외선을 흡수하는 업컨버전 나노입자를 활성산소를 생성시키는 감광제와 결합시켜야 한다. 나노입자에 결합된 감광제는 나노입자로부터 빛 에너지를 흡수하고 이를 주위의 산소에 전이시켜 활성산소를 생성한다. 뿐만 아니라 질병의 치료 효율은 업컨버전 나노입자의 표면을 개질하거나 항암 약물의 첨가, 또는 광열치료와의 결합을 통해 더욱 향상시킬 수 있다. 본 총설은 업컨버전 나노입자를 이용한 광역학치료와 이를 이용한 질병 치료 효과 향상에 대한 최근의 연구결과를 바탕으로 서술하였다.

Computed Tomography Manifestations of Histologic Subtypes of Retroperitoneal Liposarcoma

  • Lu, Jing;Qin, Qin;Zhan, Liang-Liang;Yang, Xi;Xu, Qing;Yu, Jing;Dou, Li-Na;Zhang, Hao;Yang, Yan;Chen, Xiao-Chen;Yang, Yue-Hua;Cheng, Hong-Yan;Sun, Xin-Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권15호
    • /
    • pp.6041-6046
    • /
    • 2014
  • Objective: Liposarcoma (LPS) is the most common soft tissue sarcoma and accounts for approximately 20% of all mesenchymal malignancies, often occurring in deep soft tissue of retroperitoneal space. Accurate preoperative diagnosis is therefore necessary. We explored whether computed tomography (CT) could be used to differentiate between the various types of retroperitoneal liposarcoma (RPLS). Method: Forty-seven cases of RPLS, diagnosed surgically and histologically, were analyzed retrospectively. CT features were correlated with postoperative pathological appearance. Results: The study radiologist identified 29, 11, 2, 2 and 3 RPLS as atypical lipomatous tumor/well-differentiated liposarcoma (ALT/WDL), dedifferentiated liposarcoma (DDL), myxoid/round cell liposarcoma (ML/RCL), pleomorphic liposarcoma (PL) and mixed-type liposarcoma. Analysis of CT scans revealed the following typical findings of the different subtypes of RPLS: ALT/WDL was mainly visible as a well-delineated fatty hypodense tumor with uniform density and integrity margin; DDL was marked by the combination of focal nodular density and hypervascularity. ML/RCL, PL and mixed liposarcoma showed malignant biological behaviour and CT findings need further studies. Conclusions: CT scanning can reveal important details including internal components, margins and surrounding tissues. Based on CT findings, tumor type can be roughly evaluated and biopsy location and therapeutic scheme guided.

폐외 악성 종양의 기관지내 전이 (Endobronchial Metastasis of Extrapulmonary Malignancies)

  • 김도훈;박무석;정재호;정재희;김세규;장준;김성규;김영삼
    • Tuberculosis and Respiratory Diseases
    • /
    • 제53권3호
    • /
    • pp.285-293
    • /
    • 2002
  • 배 경 : 폐는 악성 종양이 흔히 전이되는 장소로 흔히 폐실질, 흉막, 혹은 임파선으로 주로 전이되며, 기관지내 전이는 흔하지 않아 악성 종양의 기관지내 발생율은 2%정도로 알려져 있다. 저자들은 굴곡성 기관지경 검사로 확인된 증례들을 대상으로 기관지내 전이암에 대한 임상적 특징을 알아보고자 하였다. 연구방법 : 1991년 6월부터 2001년 5월까지 10년 동안 연세대학교 의과대학 세브란스병원에서 굴곡성 기관지경 검사로 폐외 악성 종양의 기관지내 전이가 확인된 27예를 대상으로 임상 양상, 치료, 경과 등을 조사하였다. 연구결과 : 평균연령은 53세이고, 남자가 17예, 여자가 10예이었다. 원발 종양은 대장암이 가장 많았으며, 자궁경부암, 위암, 유방암의 순서이었다. 원발 종양의 진단에서부터 기관지내 전이를 발견할 때까지의 기간은 평균 45.5개월이었으며, 유방암이 85.3개월로 다른 종양들에 비해 길었다. 임상 증상은 기침이 가장 많았고, 흉부 X-선 소견은 폐문부 종괴음영, 단일결절, 무기폐가 많았다. 치료는 수술, 항암 화학요법, 방사선치료 등을 시행하였고, 생존기은 평균 12.3개월이었다. 결 론 : 기관지내 전이암은 임상에서 흔한 질환이 아니며, 증상, 방사선 소견, 기관지경 소견 등이 원발성 폐암과 유사하다. 따라서 악성 종양의 병력이 있으면서 지속적인 증상이 있거나 비전형적인 병리소견을 보일 때에는 기관지내 전이암의 가능성을 염두에 두고 접근하여야 한다.

$BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교 (Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor)

  • 최장용;박지군;공현기;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

지선낭종의 초음파 소견: 조직학적으로 진단된 14개 병변의 분석 (Sonographic Appearance of Steatocystoma: An Analysis of 14 Pathologically Confirmed Lesions)

  • 윤혜영;강유선;박휘룡;안중모;이영준;이준우;강흥식
    • 대한영상의학회지
    • /
    • 제82권2호
    • /
    • pp.382-392
    • /
    • 2021
  • 목적 지선낭종의 초음파 소견을 분석하고, 표피낭종 및 지방종과의 감별진단에 도움이 되는 소견을 알아보고자 하였다. 대상과 방법 10명의 환자에서 14개의 조직학적으로 확진된 지선낭종의 초음파 소견을 후향적으로 검토하였다. 병변의 위치, 모양, 경계, 에코 발생 정도, 후방 음향 특징 및 테두리 벽 또는 병변 내 줄무늬의 존재 여부를 평가하였다. 지선낭종의 초음파 소견을 분석하고, 표피낭종 및 지방종과의 감별진단에 도움이 되는 소견을 알아보고자 하였다. 결과 지선낭종의 대부분은 피하 종괴(n = 6, 42.9%) 또는 피부층과 피하층을 함께 침범한 종괴로(n = 6, 42.9%) 나타났다. 병변은 대부분 경계가 잘 지어지고(n = 12, 85.7%) 균질한 에코 발생을 보였으며(n = 9, 64.3%), 후방 음향 특징을 나타내지 않았다(n = 9, 64.3%). 표피낭종을 지선낭종과 구별하는 가장 중요한 소견은 균질한 내부 에코 발생과(p = 0.009), 현저하지 않은 후방 음향 향상이다(p < 0.001). 지선낭종과 지방종의 구별되는 특징은 경계(p < 0.001), 에코 발생성(p = 0.034), 내부 에코 성상(p = 0.004) 및 병변 내 줄무늬의 부재였다(p < 0.001). 결론 지선낭종은 초음파 검사상 경계가 좋고 균질하며, 후방 음향 향상이 경도로 있거나 없는 종괴로 관찰되었다.