• Title/Summary/Keyword: visible diagnosis

Search Result 106, Processing Time 0.027 seconds

Normal Variation and Incidence of Coincided Alignment on Lisfranc Joint on Normal Foot Radiography (정상 성인 족부 방사선 사진에서 족근 중족 관절 선열 형성 빈도 및 정상 변이)

  • Kang, Chung-Nam;Kim, Jong-Oh;Ko, Sang-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.1
    • /
    • pp.43-50
    • /
    • 1997
  • The tarsometatarsal joint complex is formed by articulation of the five metatarsal bases with the three cuneiform bones and the cuboid bone. Fracture-dislocation of tarsometatarsal area are difficult to recognize on standard radiographs. The exact diagnosis is occasionally delayed. As a result, improper treatment and late sequelae remains. We decided to make a study of patients with normal foot radiographs on 200 cases. Standard radiographic evaluation was used to study the normal variants of the foot and to evaluate the coincided alignment of the lisfranc joint. Accurate accessment on AP & lateral & $30^{\circ}$ oblique projection of radiographs are very adventageous & important, and next final outcome was detected. : 1. Coincided alignment below 1mm and unfolded lisfranc joint on AP projection was well visalized on 1st cuneiform-metatarsal lateral border and 2nd cuneiform-metatarsal medial border. 2. Coincided alignment below 1mm and unfolded lisfranc joint on oblique projection was well visualized on 2nd cuneiform-metatarsal lateral border and 3rd cuneiform-metatarsal medial border and 3rd cuneform-metatarsal lateral border. 3. More proximal location of 2nd lisfranc joint compared to another joint was 196 cases (98%). It is due to inceleration of 2nd metatarsal base between 3rd & 1st cuneiform. 4. 3rd lisfranc joint was volarward position compared to 2nd listranc on lateral projection at 191 cases (95.5%). It's due to anterior covexity of lisfranc joint. 5. Wide dorsal sided 2nd lisfranc is investigated at 189 cases (94.5%). Because of it. 2nd & 3rd lisfrances are mainly volar dislocated usually. 6. Notching on 5th metatarsal base is visible on 171 cases (85.5%). 7. 4th lisfranc joint had offset normally within $2\sim3mm$ at 98 cases (49%). 8. 5th Lisfranc joint had normally offset within $2\sim3mm$ at 99 cases (49.5%). 9. On lateral projection, slight dorsal location of cuneiform to metatarsal base is investigated at 82 cases (41%).

  • PDF

Video Assisted Thoracic Surgery of Spontaneous Pneumothorax (비디오 흉강경을 이용한 자연성 기흉 수술)

  • Ryu, Ji-Yun;Kim, Seung-U;Jo, Gwang-Hyeon
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.512-516
    • /
    • 1997
  • We have experienced 66 cases of video assisted thoracic surgery(VATS) of spontaneous pneumothorax. The patients ranged in age from 1 Syears to 46years(mean age, 22.3years) and male patients were sixty three. The indications of video assisted thoracic surgery of spontaneous pneumothorax were recurrence, continuous air leakage, visible blabs on the chest X-ray & others. Infraoperative findings were as follows; blabs, pleural adhesion and pleural effusion. The operation was performed under general anesthesia wit double lumen endobronchial tube. Operative procedures included blebectomy and/or wedge resection of lung, vibramycin Pleurodesis with mechanical abrasion. In most cases, postoperative courses were uneventful and patients were discharged without significant complications. VATS provided the benefits of lesser postoperative pain, rapid recovery, short hospitalization, and smaller scar of wound. Conclusively VATS is a new interesting modality of surgical treatment of spontaneous pneumothorax and also can be extensively applicable in the diagnosis and treatment of other intrathoracic disease.

  • PDF

PSNR Appraisal of MRI Image (MRI 영상의 PSNR 평가)

  • Kang, Kwang-Soo;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.13-21
    • /
    • 2009
  • The Magnetic Resonance Imaging (MRI) systems consist of various parameters. Among them, the image quality can be arguably the most important part of the systems. As the other components in MRI systems have been developed and evolved, the MRI image quality has been advanced remarkably. And, the radiation imaging system is being converted from the Film to the digital method, which drives the computerization of many hospitals. The management of the tremendous radiation images becomes more critical. The data compression is used to store such large data in a network server. When the image files are compressed, the image quality degrades comparing to its original images. Even slight quality degradation of a medical image could cause an erroneous diagnosis, so the images must be handled carefully. This thesis studied the image assessment methods of comparing the quality of the compressed image to its original, and the quality of the original and the displayed images of the MRI systems via PSNR with actual medical images used in hospitals. As a result, no noticeable quality degradation was found comparing the compressed images with various digital compression methods and the original images. However, it was a different story comparing the original images and the displayed images on MRI monitors. Some noise or image distortion was visible using any regular CRT or LCD monitors were used while the special monitors designed for the MRI imaging and medical images displayed high definition images.

  • PDF

Contrast reference values in panoramic radiographic images using an arch-form phantom stand

  • Shin, Jae-Myung;Lee, Chena;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.46 no.3
    • /
    • pp.203-210
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate appropriate contrast reference values (CRVs) by comparing the contrast in phantom and clinical images. Materials and Methods: Phantom contrast was measured using two methods: (1) counting the number of visible pits of different depths in an aluminum plate, and (2) obtaining the contrast-to-noise ratio (CNR) for 5 tissue-equivalent materials (porcelain, aluminum, polytetrafluoroethylene [PTFE], polyoxymethylene [POM], and polymethylmethacrylate [PMMA]). Four panoramic radiographs of the contrast phantom, embedded in the 4 different regions of the arch-form stand, and 1 real skull phantom image were obtained, post-processed, and compared. The clinical image quality evaluation chart was used to obtain the cut-off values of the phantom CRV corresponding to the criterion of being adequate for diagnosis. Results: The CRVs were obtained using 4 aluminum pits in the incisor and premolar region, 5 aluminum pits in the molar region, and 2 aluminum pits in the temporomandibular joint (TMJ) region. The CRVs obtained based on the CNR measured in the anterior region were: porcelain, 13.95; aluminum, 9.68; PTFE, 6.71; and POM, 1.79. The corresponding values in the premolar region were: porcelain, 14.22; aluminum, 8.82; PTFE, 5.95; and POM, 2.30. In the molar region, the following values were obtained: porcelain, 7.40; aluminum, 3.68; PTFE, 1.27; and POM, - 0.18. The CRVs for the TMJ region were: porcelain, 3.60; aluminum, 2.04; PTFE, 0.48; and POM, - 0.43. Conclusion: CRVs were determined for each part of the jaw using the CNR value and the number of pits observed in phantom images.

Recent Trends in Photodynamic Therapy Using Upconversion Nanoparticles (업컨버전 나노입자를 이용한 광역학치료 연구 동향)

  • Im, Se Jin;Lee, Song Yeul;Park, Yong Il
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.138-146
    • /
    • 2018
  • Photodynamic therapy (PDT) is a great potential approach for the localized tumor removal with fewer metastatic potentials and side effects in treating the disease. In the treatment process, a photosensitizer (PS) that absorbs a light energy to generate reactive oxygen is essential. In general, a visible light is used as a light source of PDT, so that side effects from the light source are inevitable. For this reason, upconversion nanoparticles (UCNPs) using near-infrared (NIR) as an excitation source are attracting attention in the field of disease diagnosis and treatment. UCNPs have the low cytotoxicity and phototoxicity, and also advantages such as deep tissue penetration and low background autofluorescence. For PDT, UCNPs should be combined with a PS which absorbs the light energy from UCNPs and transfers it to the surrounding oxygen to produce reactive oxygen. In addition, the therapeutic efficacy can be improved by modifying nanoparticle surfaces, adding anti-cancer drugs, or combining with photothermal therapy (PTT). In this review, we summarize the recent research to improve the efficiency of PDT using UCNPs.

Computed Tomography Manifestations of Histologic Subtypes of Retroperitoneal Liposarcoma

  • Lu, Jing;Qin, Qin;Zhan, Liang-Liang;Yang, Xi;Xu, Qing;Yu, Jing;Dou, Li-Na;Zhang, Hao;Yang, Yan;Chen, Xiao-Chen;Yang, Yue-Hua;Cheng, Hong-Yan;Sun, Xin-Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6041-6046
    • /
    • 2014
  • Objective: Liposarcoma (LPS) is the most common soft tissue sarcoma and accounts for approximately 20% of all mesenchymal malignancies, often occurring in deep soft tissue of retroperitoneal space. Accurate preoperative diagnosis is therefore necessary. We explored whether computed tomography (CT) could be used to differentiate between the various types of retroperitoneal liposarcoma (RPLS). Method: Forty-seven cases of RPLS, diagnosed surgically and histologically, were analyzed retrospectively. CT features were correlated with postoperative pathological appearance. Results: The study radiologist identified 29, 11, 2, 2 and 3 RPLS as atypical lipomatous tumor/well-differentiated liposarcoma (ALT/WDL), dedifferentiated liposarcoma (DDL), myxoid/round cell liposarcoma (ML/RCL), pleomorphic liposarcoma (PL) and mixed-type liposarcoma. Analysis of CT scans revealed the following typical findings of the different subtypes of RPLS: ALT/WDL was mainly visible as a well-delineated fatty hypodense tumor with uniform density and integrity margin; DDL was marked by the combination of focal nodular density and hypervascularity. ML/RCL, PL and mixed liposarcoma showed malignant biological behaviour and CT findings need further studies. Conclusions: CT scanning can reveal important details including internal components, margins and surrounding tissues. Based on CT findings, tumor type can be roughly evaluated and biopsy location and therapeutic scheme guided.

Endobronchial Metastasis of Extrapulmonary Malignancies (폐외 악성 종양의 기관지내 전이)

  • Kim, Do-Hoon;Park, Moo-Suk;Chung, Jae-Ho;Cheong, Jae-Hee;Kim, Se-Kyu;Chang, Joon;Kim, Sung-Kyu;Kim, Young-Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.3
    • /
    • pp.285-293
    • /
    • 2002
  • Background : The lung is the most common site for a metastasis of extrapulmonary malignant tumors. however, reports on an endobronchial metastasis are rare. An endobronchial metastasis is defined as a documented extrapulmonary neoplasms metastatic to the segmental or more proximal central bronchus within a bronchoscopically visible range. The purpose of this study was to define the clinical characteristics of an endobronchial metastasis of extrapulmonary malignancies. Materials and Methods : The clinical features and treatment outcomes of 27 endobronchial metastatic cancer cases were reviewed from June, 1991 to May, 2001 in the Severance Hospital. Results : The patients' age ranged from 18 to 75. There were 17 men and 10 women. The primary tumors included the colorectum in 7, the uterine cervix in 4, the stomach and the breast in 3 patients each, and an osteosarcoma in 2 patients. The main complaint of most patients was coughing and a chest X-ray revealed a hilar mass, a parenchymal, and an atelectasis. The mean recurrence interval time was 45.5 months. The median and mean survival times were 10 and 12.3 months, respectively. Conclusion : An endobronchial metastasis is an ominous finding, and is associated with advanced-stage diseases. It requires differential diagnosis with a primary bronchogenic carcinoma. If atypical clinical features are present or an atypical cell type is discovered by a biopsy of the lesion in the lung mass, the appropriate diagnostic studies should be undertaken.

Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor ($BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교)

  • Choi, Jang-Yong;Park, Ji-Koon;Gong, Hyun-Gi;Ahn, Sang-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

Sonographic Appearance of Steatocystoma: An Analysis of 14 Pathologically Confirmed Lesions (지선낭종의 초음파 소견: 조직학적으로 진단된 14개 병변의 분석)

  • Hyeyoung Yoon;Yusuhn Kang;Hwiryong Park;Joong Mo Ahn;Eugene Lee;Joon Woo Lee;Heung Sik Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.382-392
    • /
    • 2021
  • Purpose To evaluate the ultrasonographic characteristics of steatocystomas focusing on the features that aid in differentiating them from epidermal inclusion cysts and lipomas. Materials and Methods The ultrasonographic findings of 14 histologically proven steatocystomas in 10 patients were retrospectively reviewed. The following features were assessed: the layer of involvement, shape, margin, echogenicity, posterior acoustic features, and the presence of a visible wall or intralesional striations. The findings were compared with those of subcutaneous lipomas and epidermal inclusion cysts to identify those findings that aid in the differential diagnosis of steatocystomas. Results The majority of steatocystomas appeared as a subcutaneous mass (n = 6, 42.9%) or a mass involving both the dermal and subcutaneous layers (n = 6, 42.9%). Steatocystomas exhibited a well-defined smooth margin (n = 12, 85.7%) and homogeneous echogenicity (n = 9, 64.3%), and showed no specific posterior acoustic features (n = 9, 64.3%). The most important features that differentiated steatocystomas from epidermal inclusion cysts were a homogeneous internal echotexture (p = 0.009) and absent or less prominent posterior acoustic enhancement (p < 0.001). The features that distinguished steatocystomas from lipomas were the margin (p < 0.001), echogenicity (p = 0.034), internal echotexture (p = 0.004), and the absence of intralesional striations (p < 0.001). Conclusion Steatocystomas appeared as well-defined homogeneous masses with mild or absent posterior acoustic enhancement.

Expression of MAGE in the Induced Sputum of Lung Cancer Patients (폐암환자의 유도 객담에서 MAGE의 발현)

  • Yook, Dong-Seung;Shin, Ho-Sik;Choi, Paul;Kim, Ji-Hae;Shin, Seong-Hoon;Ok, Chul-Ho;Cho, Hyun-Myung;Jang, Tae-Won;Jung, Maan-Hong;Park, Jong-Wook;Jeon, Chang-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.3
    • /
    • pp.265-274
    • /
    • 2002
  • Background : Tumor associated antigens, which are produced specifically by tumor cells, are promising targets for the early diagnosis and immunotherapy. Among the tumor associated antigens, MAGE (a melanoma antigen), BAGE, GAGE, PRAME and NY-ESO were named as cancer/testis specific antigens they are detected exclusively in the testis or cancer cells If MAGE is easily detectable in the sputum, it would become a convenient method for diagnosing lung cancer. This study was undertaken to investigate MAGE expression in the induced sputum obtained from lung cancer patients. Materials and Methods : In 14 control patients and 30 lung cancer patients, the induced sputum was collected after inhaling 3% saline(5 cc) delivered by nebulizer for approximately 5 minutes after a mouth rinse and bronchodilator inhalation. The induced sputum was placed in a conservative-mixed solution (guanidinium isothiocyanate, Triton X-100). The total cellular mRNA was extracted from the cells and RT PCR and nested PCR were run in 30 and 35 cycles respectively, with two different types of primers specially designed to detect six subtypes of MAGE DNA simultaneously. Results : MAGE expression was not detected in the 14 controls, but in the 30 cancer patients, MAGE was found in 24 patients (80%, p=0.001). In the cancer patients, there were no differences in the expression level according to the tissue types (squamous cell cancer 13/17, adenocarcinoma 7/9, and small cell cancer 4/4, p-0.56). Among the 24 MAGE-positive patients, the tumor was not visible on a bronchoscopy in 11 patients (45.8%). Conclusion : A study of MAGE in induced sputum appears to be a useful and complementary method in the diagnosis of lung cancer. A further prospective study with more patients is recommended.