• Title/Summary/Keyword: virus removal

Search Result 70, Processing Time 0.041 seconds

Evaluation of Viral Inactivation Efficacy of a Continuous Flow Ultraviolet-C Reactor (UVivatec) (연속 유동 Ultraviolet-C 반응기(UVivatec)의 바이러스 불활화 효과 평가)

  • Bae, Jung-Eun;Jeong, Eun-Kyo;Lee, Jae-Il;Lee, Jeong-Im;Kim, In-Seop;Kim, Jong-Su
    • Microbiology and Biotechnology Letters
    • /
    • v.37 no.4
    • /
    • pp.377-382
    • /
    • 2009
  • Viral safety is an important prerequisite for clinical preparations of all biopharmaceuticals derived from plasma, cell lines, or tissues of human or animal origin. To ensure the safety, implementation of multiple viral clearance (inactivation and/or removal) steps has been highly recommended for manufacturing of biopharmaceuticals. Of the possible viral clearance strategies, Ultraviolet-C (UVC) irradiation has been known as an effective viral inactivating method. However it has been dismissed by biopharmaceutical industry as a result of the potential for protein damage and the difficulty in delivering uniform doses. Recently a continuous flow UVC reactor (UVivatec) was developed to provide highly efficient mixing and maximize virus exposure to the UV light. In order to investigate the effectiveness of UVivatec to inactivate viruses without causing significant protein damage, the feasibility of the UVC irradiation process was studied with a commercial therapeutic protein. Recovery yield in the optimized condition of $3,000\;J/m^2$ irradiation was more than 98%. The efficacy and robustness of the UVC reactor was evaluated with regard to the inactivation of human immunodeficiency virus (HIV), hepatitis A virus (HAV), bovine herpes virus (BHV), bovine viral diarrhea virus (BVDV), porcine parvovirus (PPV), bovine parvovirus (BPV), minute virus of mice (MVM), reovirus type 3 (REO), and bovine parainfluenza virus type 3 (BPIV). Non enveloped viruses (HAV, PPV, BPV, MVM, and REO) were completely inactivated to undetectable levels by $3,000\;J/m^2$ irradiation. Enveloped viruses such as HIV, BVDV, and BPIV were completely inactivated to undetectable levels. However BHV was incompletely inactivated with slight residual infectivity remaining even after $3,000\;J/m^2$ irradiation. The log reduction factors achieved by UVC irradiation were ${\geq}3.89$ for HIV, ${\geq}5.27$ for HAV, 5.29 for BHV, ${\geq}5.96$ for BVDV, ${\geq}4.37$ for PPV, ${\geq}3.55$ for BPV, ${\geq}3.51$ for MVM, ${\geq}4.20$ for REO, and ${\geq}4.15$ for BPIV. These results indicate that UVC irradiation using UVivatec was very effective and robust in inactivating all the viruses tested.

Studies on Nuclear Transplantation in Mouse Embryos III. Production of Nuclear Transplanted Mice (생쥐배의 핵치환에 관한 연구 III. 핵치환 생쥐의 생산)

  • 박용석;정형민;박세필;이상진;정병현;정길생
    • Korean Journal of Animal Reproduction
    • /
    • v.13 no.2
    • /
    • pp.93-97
    • /
    • 1989
  • These experiments were carried out to develop the technique of nuclear transplantation necessary for elevating utilization efficiency of high quality embryos and the production of clone animals. Embryos of pronucleus stages were obtained from ICR mice. Removal of pronuclei and their transfer to recipient embryos were carried out by micromanipulation and virus mediation. The results obtained in these experiments were summarized as follows ; 1. Total 337 pairs of pronuclear stage embryos were subjected to nuclear transplantatin and 247 pairs(73.3%) of them were successfully transplanted and the number of fused embryos between transplanted nucleus and cytoplasm was 188 pairs(55.8%). 2. Of the 188 fused embryos cultured in vitro, 174(92.4%), 131(69.7%) and 117(62.2%) embryos were developed to 2-cell, morula and blastocyst stages, respectively. 3. When total 104 nuclear transplanted embryos were transferred to uteri of recipient mice on day 2-3 of pseudopregnancy, 4 of 12 recipient mice were pregnant and the number of embryos developed to young was 28(26.9%).

  • PDF

Numerical Analysis for Characteristic of Flow and Disinfection Performance with Variation of Guide Wall in Clearwell (도류벽 형태에 따른 정수지 내 유동 특성과 소독능 변화에 대한 수치 해석적 연구)

  • Lee, Suk-Won;Park, Jun-Jung;Rhee, Gwang-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.767-772
    • /
    • 2006
  • The SWTR(Surface Water Treatment Rule) requires achieving removal 99.9% Giardia and 99.99% Virus. To remove Giardia and Virus, disinfection process is essential process. CT is important index for Disinfection performance. CT value is expressed by CXT. C is represented by disinfection concentration and T is represented by $T_{10}$ which means 90% contact time in clearwell. To improve Disinfection performance, it is desirable to increase $T_{10}$. Primary factor affected $T_{10}$ is flow Pattern. Because guide wall change that flow pattern is uniform, we have installed guide wall to increase $T_{10}$. In this paper, we have performed numerical analysis for clearwell installed symmetric guide wall and center divided guide wall using CFD. We have analyzed flow pattern and $T_{10}$ in each clearwell. And. we compare symmetric guide wall with center divided guide wall in flow pattern and $T_{10}$.

  • PDF

Treatment of Secondary Municipal Wastewater by Submerged Hollow Fiber MF Membranes for Water Reuse (침지형 MF 중공사막을 이용한 하수 2차 처리수의 재이용 연구)

  • Hyun, Seunghoon;Kim, Eung Do;Hong, Seungkwan;Ahn, Wonyoung;Yim, Seongkeun;Kim, Geontae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.47-52
    • /
    • 2005
  • This study was conducted to evaluate the performance of submerged hollow fiber MF processes to treat secondary wastewater for water reuse. Specifically, membrane productivity and filtrate water quality were investigated under various operating conditions (i.e. flux, recovery, and backwash rate) at pilot-scale. Membrane fouling became more severe with increasing flux and recovery, suggesting that low flux operation (< 25 LMH) was desirable. At high flux operating(> 37.5 LMH), increasing backwash rate showed only limited success. The biofouling, quantified by PEPA and BFHPC, was also significant in wastewater reclamation, and biogrowth control by chlorine, were necessary to improve membrane productivity. Filtrate water qualities are in good compliance with water reuse regulations regardless of operating conditions (flux, recovery and backwash rate). Particle (e.g. turbidity) removal ranged from 89 to 98%, while only 11 to 21% of organics (e.g. NPDOC) were removed by MF membrane. Only small improvement in biostability (e.g. AOC) was achieved by MF system, and thus, without post disinfection, significant microorganisms might be present in the filtrate due to regrowth. Lastly, in order to further investigate pathogen removal, controlled microbial challenge tests were performed by monitoring Giardia, Cryptosporidium, bacteria and virus, and showed relatively good microbial removal.

Efficiency of the Hybrid-type Air Purifier on Reducing Physical and Biological Aerosol (복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과)

  • Kim, Ki-Youn;Kim, Chi-Nyon;Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.478-484
    • /
    • 2006
  • There was no significant difference in the CADR (Clean Air Delivery Rate) between physical aerosols, NaCl and smoke, and biological aerosols, airborne MS2 virus and P. fluorescens, which implicate that the hybrid-type of air purifier, applying the unipolar ion emission and the radiant catalytic ionization, imposed identical reduction effect on both physical aerosol and bioaerosol. Ventilation decreases the efficiency of air cleaning by unipolar ionization because high ventilation diminishes the particle concentration reduction effect. The particle removal efficiency decreases with increase in the chamber volume because of the augmented ion diffusion and higher ion wall loss rate. Particle size affects the efficiency of air ionization. The efficiency is high for particles with very small diameter because reduction of charge increases with particle size. If there is no increasing supply of ions, the efficiency of air cleaning by unipolar ionization increases with respect to initial concentration of particles because of the large space charge effect at high particle concentration and amplified electric field.

Removal Efficiency in Water Treatment Process and Characteristic of Cell Sensitivity of Waterborne Enteric Viruses (수계 바이러스의 정수처리공정별 제거율 및 세포주별 감염특성 조사)

  • Jung, Eun-Young;Park, Hong-Gi;Cha, Dong-Jin;Jung, Mi-Eun;You, Pyung-Jong
    • Journal of Life Science
    • /
    • v.19 no.3
    • /
    • pp.373-377
    • /
    • 2009
  • Poliovirus, coxsackievirus, and ecovirus isolates from environmental sources were compared with laboratory strains to determine their removal rate in the water treatment process. The recovery efficiencies of poliovirus, coxsackievirus and echovirus using positive strains ranged from $72{\sim}108%$. Regarding virus removal efficiency in water treatment of pilot-plants, about 99% of all of the viruses were removed in the sedimentation step and 100% of viruses were clearly removed through post-ozonation and BAC filteration. Using six cell lines tested viral sensitivity in cell line and showed different sensitivity as viruses. Polioviruses showed higher sensitivity in the BGMK cell line than other cells, and coxsackieviruses were detected in higher level in the BGMK and Vero cell lines. On the other hand, the RD cell line was useful in the isolation of ecoviruses.

Pattern of the Occurrence of Tomato spotted wilt virus in Jeonnam Province (전남 지역의 토마토반점위조바이러스병 발생 양상)

  • Ko, Sug-Ju;Kang, Beom-Ryong;Choi, Duck-Soo;Kim, Do-Ik;Lee, Gwan-Seok;Kim, Chang-Seok;Choi, Hong-Soo
    • Research in Plant Disease
    • /
    • v.19 no.4
    • /
    • pp.273-280
    • /
    • 2013
  • Tomato spotted wilt virus (TSWV) was occurred at 8 areas including Naju, Suncheon, Younggwang, Youngam, and Shinan in Jeonnam province and the crops of Younggwang were severely damaged by TSWV. The hot pepper (Capsicum annuum), bell pepper (Capsicum annuum v ar. angulosum) and tomato (Solanum lycopersicon) in greenhouse and hot pepper in open field were infected by TSWV. Especially, hot pepper was severely damaged by TSWV infection. The survey data indicated that 1.1-30% in the nursery field at Naju, Suncheon, and Jangheung were infected by TSWV. Plants were infected by TSWV from early June to August. However, TSWV-infected seedlings from nursery fields showed the disease symptoms from May after transplanting. In pepper greenhouses, Frankliniella occidentalis was more dominant insect vector than Frankliniella intonsa. But in open field, the population of insect vector was opposed to greenhouse. In addition, the removal of weeds was able to delay the incidence of TSWV via side-window of greenhouse in Winter. Taken together, the control of weed and insect vector nearby side-window of greenhouse is important to prevent TSWV infection of plants.

Prevention and Adjuvant Therapy of Recurrent Respiratory Papillomatosis (재발성 호흡기 유두종증의 예방과 보조 요법)

  • Lee, Dong Kun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.31 no.1
    • /
    • pp.7-12
    • /
    • 2020
  • Recurrent respiratory papillomatosis (RRP) is characterized by repeated recurrence in the respiratory system, such as the pharynx, larynx, and trachea, caused by the human papilloma virus. The main treatment is surgical removal of the papilloma. However repeated recurrence of RRP in multiple areas is burdened for the surgeon. In addition to the surgery, various adjuvant therapies have been studied to reduce the recurrence. Literature review was conducted with a focus on the adjuvant treatments for RRP.

Cation exchange membrane and anion exchange membrane aided electrolysis processes for hypochlorite generation

  • Seong K. Kim;Dong-Min Shin;Ji Won Rhim
    • Membrane and Water Treatment
    • /
    • v.14 no.2
    • /
    • pp.55-63
    • /
    • 2023
  • In this study, the influence of different IEMs (ion exchange membranes) to performance of the hypochlorite electrolysis unit with Cl2 recovery stream was investigated. More specifically, Nafion 117-a representative cation exchange membrane (CEM)-and aminated polypheylene oxide (APPO)-an anion exchange membrane (AEM)-were installed in the hypochlorite electrolysis unit, and the performance and the energy efficiency of the units were evaluated and compared. Regardless of whether CEM (Nafion 117) or AEM (APPO) was installed, the rate of hypochlorite generation was increased (by up to 24.3% and 22.2% for Nafion 117 and APPO, respectively) compared with the unit without an IEM. On the other hand, the power efficiency and the optimum operation condition of hypochlorite production units seem to depend on the conductivity and stability of the installed IEM. As the result, between Nafion 117 and APPO, higher performance and efficiency were achieved with Nafion 117, due to excellent conductivity and stability of the membrane.

Guidelines for dental clinic infection prevention during COVID-19 pandemic (코로나 바이러스 대유행에 따른 치과 의료 관리 가이드라인)

  • Kim, Jin
    • Journal of Korean Academy of Dental Administration
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Dental settings have unique characteristics that warrant specific infection control considerations, including (1) prioritizing the most critical dental services and provide care in a way that minimizes harm to patients due to delayed care, or harm to personnel from potential exposure to persons infected with the COVID-19 disease, and (2) proactively communicate to both personnel and patients the need for them to stay at home if sick. For health care, an interim infection prevention and control recommendation (COVID-19) is recommended for patients suspected of having coronavirus or those whose status has been confirmed. SARS-CoV-2, which is the virus that causes COVID-19, is thought to be spread primarily between people who are in close contact with one another (within 6 feet) through respiratory droplets that are produced when an infected person coughs, sneezes, or talks. Airborne transmission from person-to-person over long distances is unlikely. However, COVID-19 is a new disease, and there remain uncertainties about its mode of spreads and the severity of illness it causes. The virus has been shown to persist in aerosols for several hours, and on some surfaces for days under laboratory conditions. COVID-19 may also be spread by people who are asymptomatic. The practice of dentistry involves the use of rotary dental and surgical instruments, such as handpieces or ultrasonic scalers, and air-water syringes. These instruments create a visible spray that can contain particle droplets of water, saliva, blood, microorganisms, and other debris. While KF 94 masks protect the mucous membranes of the mouth and nose from droplet spatter, they do not provide complete protection against the inhalation of airborne infectious agents. If the patient is afebrile (temperature <100.4°F)* and otherwise without symptoms consistent with COVID-19, then dental care may be provided using appropriate engineering and administrative controls, work practices, and infection control considerations. It is necessary to provide supplies for respiratory hygiene and cough etiquette, including alcohol-based hand rub (ABHR) with 60%~95% alcohol, tissues, and no-touch receptacles for disposal, at healthcare facility entrances, waiting rooms, and patient check-ins. There is also the need to install physical barriers (e.g., glass or plastic windows) in reception areas to limit close contact between triage personnel and potentially infectious patients. Ideally, dental treatment should be provided in individual rooms whenever possible, with a spacing of at least 6 feet between the patient chairs. Further, the use of easy-to-clean floor-to-ceiling barriers will enhance the effectiveness of portable HEPA air filtration systems. Before and after all patient contact, contact with potentially infectious material, and before putting on and after removing personal protective equipment, including gloves, hand hygiene after removal is particularly important to remove any pathogens that may have been transferred to the bare hands during the removal process. ABHR with 60~95% alcohol is to be used, or hands should be washed with soap and water for at least 20 s.