Numerical Analysis for Characteristic of Flow and Disinfection Performance with Variation of Guide Wall in Clearwell

도류벽 형태에 따른 정수지 내 유동 특성과 소독능 변화에 대한 수치 해석적 연구

  • Lee, Suk-Won (Graduated School of Mechanical Information Engineering University of Seoul) ;
  • Park, Jun-Jung (Graduated School of Mechanical Information Engineering University of Seoul) ;
  • Rhee, Gwang-Hoon (Department of Mechanical and Information Engineering, University of Seoul)
  • 이석원 (서울시립대학교 대학원 기계정보공학과) ;
  • 박준정 (서울시립대학교 대학원 기계정보공학과) ;
  • 리광훈 (서울시립대학교 기계정보공학과)
  • Published : 2006.06.21

Abstract

The SWTR(Surface Water Treatment Rule) requires achieving removal 99.9% Giardia and 99.99% Virus. To remove Giardia and Virus, disinfection process is essential process. CT is important index for Disinfection performance. CT value is expressed by CXT. C is represented by disinfection concentration and T is represented by $T_{10}$ which means 90% contact time in clearwell. To improve Disinfection performance, it is desirable to increase $T_{10}$. Primary factor affected $T_{10}$ is flow Pattern. Because guide wall change that flow pattern is uniform, we have installed guide wall to increase $T_{10}$. In this paper, we have performed numerical analysis for clearwell installed symmetric guide wall and center divided guide wall using CFD. We have analyzed flow pattern and $T_{10}$ in each clearwell. And. we compare symmetric guide wall with center divided guide wall in flow pattern and $T_{10}$.

Keywords