파도에너지를 효율적으로 이용하기위한 파력진동발전기에 대한 연구 (The research of vibration power generation to make effective use of ocean wave energy)

  • 이홍찬;이재호;한기봉
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 후기공동학술대회 논문집
    • /
    • pp.75-75
    • /
    • 2011
  • This paper has been studied that ocean wave vibration power generator is composed of buoy and vibration generator to make effective use of ocean wave energy. We designed buoy to can occur resonance for dominant frequency with ocean wave. And then we fitted the natural frequency of vibration system with vibration power generator to buoy's natural frequency. And we can show that the amplitude of ocean wave up and down motion is decreased, on the other hand, the displacement of vibration system with vibration power generator is increased. Therefore, ocean wave vibration power generator which is proposed in this paper has merits not only securing its stability from surroundings but also producing more electronic power by using ocean wave energy.

  • PDF

교량의 진동을 이용한 진동력 발전 기초실험연구 (A Basic Experimental Study on Vibration Power Generation Using Bridge Vibration)

  • 조병완;이윤성;김영지;윤광원
    • 한국도로학회논문집
    • /
    • 제12권4호
    • /
    • pp.121-129
    • /
    • 2010
  • 본 논문에서는 차량주행 시 교량에서 발생하는 진동에너지를 사회기반시설에 활용 가능한 전기에너지로 변환하는 진동력 발전시스템의 기초개념에 대해 연구하였다. 이 논문은 자기유도기술개념의 교량 진동력 발전 시스템에 대한 개념을 정립하고, 교량의 진동에너지를 전기에너지로 변환하는 진동력 발전장치를 제안하였다. 또한, 진동력 발전의 실 교량 적용성을 검토하기 위하여 제안한 진동력 발전장치를 용인신봉구역에 최근 건설된 차도교량에 직접 설치하여 실험함으로써, 본 논문에서 제안된 진동력 발전 장치의 발전성능과 교량의 상시진동을 이용한 진동력 발전의 적용 가능성을 확인하였다.

녹색교통망을 위한 진동력 발전 기초 실험연구 (A Basic Experimental Study on Vibration Power Generator for A Green Traffic Network)

  • 조병완;이윤성;김영지;박정훈
    • 대한토목학회논문집
    • /
    • 제29권6D호
    • /
    • pp.675-683
    • /
    • 2009
  • 본 논문에서는 도로와 철도에서 자동차와 열차주행시에 발생하는 진동에너지를 건축-토목 구조물에 활용 가능한 전기에너지로 변환하는 진동력 발전시스템 인프라 구축을 위한 기초 개념에 대해 연구하였다. 본 연구에서는 자기유도기술을 활용하여 진동에너지를 전기에너지로 변환하는 진동력 발전장치를 제안하고, 자기유도기술의 기본 원리 및 진동력 발전장치의 동적특성에 대해 설명하였다. 마지막으로 외력과 진동속도에 따라 진동력 발전장치에서 발생하는 기전력의 세기와의 상관관계를 분석하기 위해 다양한 변수를 두고 실내실험을 수행하였고, 이러한 실험결과를 토대로 시험용 진동력 발전장치의 적용성과 효용성을 분석하여, 최대 가용 전력을 획득하기 위한 진동력 발전시스템의 최적설계에 대한 기초 자료를 확보하였다.

Regression Analysis of Vibration Phenomenon on the Load Capacity and Elapsed Year of a Power Transformer

  • Kim, Young-Dal
    • 조명전기설비학회논문지
    • /
    • 제23권3호
    • /
    • pp.30-37
    • /
    • 2009
  • The majority of the causes for the failures of power transformers in operation are mechanical defects due to vibration. The vibration phenomenon was measured from the power transformers in operation in the substations. The vibration measurement was performed in a $6{\times}4$ structure on one side of each transformer. The vibrations of the measured points were presented in two and three dimensions and analyzed. The results, according to the elapsed year of the transformer and the load capacity to the transformer, were analyzed. These results could be used as basic data with which to establish vibration standards for power transformers. In addition, the load capacity-vibration phenomenon correlation was examined and regression analysis was performed to derive the estimation function. The vibration phenomenon according to the elapsed yeah was also estimated to derive the function. Then the analysis of the power transformers was used to set vibration standards for them based on the vibration data.

디젤 발전소의 T-mode 진동에 관한 실험적 고찰 (An Experimental Study of T-mode Vibration on the Diesel Power Plant)

  • 이돈출;남택근;배용채;김연환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.411-416
    • /
    • 2005
  • Nowadays, diesel power plant using low speed two stroke diesel engine is widely used in islands and restricted areas. Considerations were given to its benefit of high thermal efficiency, reliability and durability compared to the other prime movers. However, various types of engine vibration affect neighboring buildings to their structural vibration. For this, diesel power plant are held liable for the troubles caused by these vibration. These are mainly due to the X- and H-type engine vibrations which we excited by the X- and H- guide force moment. Authors have identified a structural vibration of new pattern called ‘T-mode vibration’ due to the torsional vibration of shafting system. In this paper, T-mode vibration is analyzed through an experimental method based on the global vibration measurement.

  • PDF

육상 디젤 발전소용 저속 2행정 디젤엔진의 종진동에 관한 연구 (A Study of Axial Vibration of Two Stroke Low Speed Diesel Engine on the Diesel Power Plant)

  • 이돈출;남정길;고재용
    • 한국소음진동공학회논문집
    • /
    • 제11권9호
    • /
    • pp.398-405
    • /
    • 2001
  • The maximum and mean indicated pressure of two stroke low speed diesel engine has been continuously increased with a view of increasing engine power and also reducing fuel consumption. As a result, axial excitation has been increased comparing to that of the previous one. So the axial vibration damper in standard one is applied to all two stroke low speed diesel engine at the free end of crankshaft. Though many studies were carried out for marine use, few has been made for diesel power plant because there was little demand for power plant. Nowadays, diesel engine is much to be used for many benefits. In this paper, the optimum design of axial vibration on the 65 kW diesel power plant with tow 9K80MC-S engines of 9 cylinders was carried out. And the axial-torsional coupled vibration of this shafting system is identified by theoretical analysis and vibration measurement.

  • PDF

진동 절연계에서 절연요소 회전강성계수가 고주파수 대역 진동파워 전달에 미치는 영향 (Effects of Rotational Stiffness of Isolators on Vibration Power Transmission in Vibration Isolation Systems over High Frequency Range)

  • 김진성;이호정;김광준
    • 한국소음진동공학회논문집
    • /
    • 제13권5호
    • /
    • pp.375-383
    • /
    • 2003
  • For a performance analysis of vibration isolation systems, the concept of vibration power flow can be employed preferably when noise radiated from the supporting structure with finite impedances is of interest. The idea is basically simple to understand and formulas for precise estimation of the vibration power are easy to derive. However, It is often required to simplify the process of experimentation under several assumptions due to instrumental limitations. For an example, rotational degree of freedom has not been well treated in bending vibrations of beam or plate-like structures. Yet, several recent studies showed that the moments and rotations play an important role in power transmission and should be taken into consideration carefully as the frequency range of interest goes to audibly high. Therefore, it is readily agreed that reduction of the noise radiation over the high frequency range can be effectively accomplished by adjusting the rotational stiffness of the isolator without changing the vibration isolator efficiency in low frequency range relevant to the translational stiffness of the isolator In this paper, the vibration power flow approach is applied to an AC motor installed on a finite plate in order to illustrate the contribution of the rotational vibration power to the total vibration power transmission. The effects of rotational stiffness of the isolator on the vibration power transmission are investigated by inserting various shapes of Isolators with different rotational stiffness but with $ame translational stiffness between the motor and the plate. The resultant noise radiation from the plate is presented to verify the proposed approach.

A Study on the Assignment of the Vibration Classes to the Power Transformers in Operation (154[kV])

  • Kim, Young-Dal
    • 조명전기설비학회논문지
    • /
    • 제23권11호
    • /
    • pp.52-60
    • /
    • 2009
  • High reliability is essential for power transformers, and their fault causes are reportedly more related to mechanical causes than electrical ones. The transformer soundness judgment currently depends only on the electrical insulation characteristic and the chemical test of the insulation oil, so that there are few fundamental measures against the frequent mechanical damages and failures in transformers. The mechanical soundness judgment techniques are conducted through processes that include structural analysis and vibration resistance treatment during the manufacturing process of each manufacturer, but the vibration is not tested during the design, manufacturing, and operating processes since there are no detailed technical standards and procedures on the vibration problem, which are important in terms of maintenance. Therefore, in this study, vibration phenomena were measured from the 32 power transformers in operation in the substations under the Daejeon Power Transmission District Office of the Korean Electric Power Corporation (KEPCO). The vibration was measured at 24 sections ($6{\times}4$) on one side, and only the maximum values were selected from the measured vibration values. This was because the maximum vibration values more significantly affect the soundness of the transformer than the average vibration values. The vibration classes were given considering the maximum vibration based on ISO 10016-1 (2001).

연성된 쉘 구조물의 진동 파워흐름해석 (Vibration Power Flow Analysis of Coupled Shell Structures)

  • Kim, Il-Hwan;Hong, Suk-Yoon;Park, Do-Hyun;Kil, Hyun-Gwon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.352.2-352
    • /
    • 2002
  • In this paper, Power Flow Analysis (PFA) method has been applied to the prediction of vibration energy density and intensity of coupled shell structures in the medium-to-high frequency ranges. To consider the wave transformation at joint between shell elements, power transmission and reflection coefficients are investigated for various joint angles, and here Donnell-Mushtari thin shell theory has been used. (omitted)

  • PDF

다차원 진동/소음 절연을 위한 진동 파워 이용법 (Multi-dimensional vibration/noise isolation by vibration power analysis)

  • 김광준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.33-48
    • /
    • 2000
  • Limitations of the simple single degree of freedom vibration isolation theory in real applications are discussed and a theory of multi-dimensional vibration/noise isolation by power approach is introduced. Illustrations of the application to compressor of an air-conditioner are presented together with problems caused by approximations. Then possible sources of distortions in the vibration power estimation are looked into and some relevant research topics are suggested.

  • PDF