• Title/Summary/Keyword: vibration power

Search Result 2,753, Processing Time 0.031 seconds

The research of vibration power generation to make effective use of ocean wave energy (파도에너지를 효율적으로 이용하기위한 파력진동발전기에 대한 연구)

  • Lee, Hong-Chan;Lee, Jae-Ho;Han, Ki-Bong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.75-75
    • /
    • 2011
  • This paper has been studied that ocean wave vibration power generator is composed of buoy and vibration generator to make effective use of ocean wave energy. We designed buoy to can occur resonance for dominant frequency with ocean wave. And then we fitted the natural frequency of vibration system with vibration power generator to buoy's natural frequency. And we can show that the amplitude of ocean wave up and down motion is decreased, on the other hand, the displacement of vibration system with vibration power generator is increased. Therefore, ocean wave vibration power generator which is proposed in this paper has merits not only securing its stability from surroundings but also producing more electronic power by using ocean wave energy.

  • PDF

A Basic Experimental Study on Vibration Power Generation Using Bridge Vibration (교량의 진동을 이용한 진동력 발전 기초실험연구)

  • Jo, Byung-Wan;Lee, Yun-Sung;Kim, Yung-Ji;Yoon, Kwang-Won
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.121-129
    • /
    • 2010
  • Through this paper, we studied on the basic concept of vibration-induced power generation for urban infrastructures. Since the travelling of automobiles on the bridge cause vibration, it is possible to convert the vibration energy into green-electric energy by utilizing magnetic induction technology. In this paper we define the concept of green-bridge vibration power generation system which contains the concept of magnetic induction technology and propose a vibration power generation device for converting the bridge vibration energy into the electric energy. Also, an experiment was held by applying the vibration power generator on a real bridge. The results showed the applicability and effectiveness of the vibration power generator.

A Basic Experimental Study on Vibration Power Generator for A Green Traffic Network (녹색교통망을 위한 진동력 발전 기초 실험연구)

  • Jo, Byung-Wan;Lee, Yun-Sung;Kim, Young-Ji;Park, Jung-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6D
    • /
    • pp.675-683
    • /
    • 2009
  • A Basic experimental study for the development of vibration-power generation system from the vibration energy of urban infrastructure, such as a railroad, highway, and bridges, was carried out to harvest electricity from moving vehicles. Starting with the proposal of vibration power generator which converts vibration energy to an electric power by using self-induction technology, the research explains the basic concept of self-induction technology and the dynamic characteristics of a ibration power generator. Also, in order to analyze the correlation of an electromotive force from vibration power generator which depends on external force and vibration speeds, many indoor experiments with various variables were achieved. Based on the experimental results, a vibration power generator system's ability were analyzed. With those results, basic data of vibration power generator system to acquire the maximum available power was confirmed.

Regression Analysis of Vibration Phenomenon on the Load Capacity and Elapsed Year of a Power Transformer

  • Kim, Young-Dal
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.3
    • /
    • pp.30-37
    • /
    • 2009
  • The majority of the causes for the failures of power transformers in operation are mechanical defects due to vibration. The vibration phenomenon was measured from the power transformers in operation in the substations. The vibration measurement was performed in a $6{\times}4$ structure on one side of each transformer. The vibrations of the measured points were presented in two and three dimensions and analyzed. The results, according to the elapsed year of the transformer and the load capacity to the transformer, were analyzed. These results could be used as basic data with which to establish vibration standards for power transformers. In addition, the load capacity-vibration phenomenon correlation was examined and regression analysis was performed to derive the estimation function. The vibration phenomenon according to the elapsed yeah was also estimated to derive the function. Then the analysis of the power transformers was used to set vibration standards for them based on the vibration data.

An Experimental Study of T-mode Vibration on the Diesel Power Plant (디젤 발전소의 T-mode 진동에 관한 실험적 고찰)

  • Lee, D.C.;Nam, T.K.;Bae, Y.C.;Kim, Y.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.411-416
    • /
    • 2005
  • Nowadays, diesel power plant using low speed two stroke diesel engine is widely used in islands and restricted areas. Considerations were given to its benefit of high thermal efficiency, reliability and durability compared to the other prime movers. However, various types of engine vibration affect neighboring buildings to their structural vibration. For this, diesel power plant are held liable for the troubles caused by these vibration. These are mainly due to the X- and H-type engine vibrations which we excited by the X- and H- guide force moment. Authors have identified a structural vibration of new pattern called ‘T-mode vibration’ due to the torsional vibration of shafting system. In this paper, T-mode vibration is analyzed through an experimental method based on the global vibration measurement.

  • PDF

A Study of Axial Vibration of Two Stroke Low Speed Diesel Engine on the Diesel Power Plant (육상 디젤 발전소용 저속 2행정 디젤엔진의 종진동에 관한 연구)

  • 이돈출;남정길;고재용
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.9
    • /
    • pp.398-405
    • /
    • 2001
  • The maximum and mean indicated pressure of two stroke low speed diesel engine has been continuously increased with a view of increasing engine power and also reducing fuel consumption. As a result, axial excitation has been increased comparing to that of the previous one. So the axial vibration damper in standard one is applied to all two stroke low speed diesel engine at the free end of crankshaft. Though many studies were carried out for marine use, few has been made for diesel power plant because there was little demand for power plant. Nowadays, diesel engine is much to be used for many benefits. In this paper, the optimum design of axial vibration on the 65 kW diesel power plant with tow 9K80MC-S engines of 9 cylinders was carried out. And the axial-torsional coupled vibration of this shafting system is identified by theoretical analysis and vibration measurement.

  • PDF

Effects of Rotational Stiffness of Isolators on Vibration Power Transmission in Vibration Isolation Systems over High Frequency Range (진동 절연계에서 절연요소 회전강성계수가 고주파수 대역 진동파워 전달에 미치는 영향)

  • 김진성;이호정;김광준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.5
    • /
    • pp.375-383
    • /
    • 2003
  • For a performance analysis of vibration isolation systems, the concept of vibration power flow can be employed preferably when noise radiated from the supporting structure with finite impedances is of interest. The idea is basically simple to understand and formulas for precise estimation of the vibration power are easy to derive. However, It is often required to simplify the process of experimentation under several assumptions due to instrumental limitations. For an example, rotational degree of freedom has not been well treated in bending vibrations of beam or plate-like structures. Yet, several recent studies showed that the moments and rotations play an important role in power transmission and should be taken into consideration carefully as the frequency range of interest goes to audibly high. Therefore, it is readily agreed that reduction of the noise radiation over the high frequency range can be effectively accomplished by adjusting the rotational stiffness of the isolator without changing the vibration isolator efficiency in low frequency range relevant to the translational stiffness of the isolator In this paper, the vibration power flow approach is applied to an AC motor installed on a finite plate in order to illustrate the contribution of the rotational vibration power to the total vibration power transmission. The effects of rotational stiffness of the isolator on the vibration power transmission are investigated by inserting various shapes of Isolators with different rotational stiffness but with $ame translational stiffness between the motor and the plate. The resultant noise radiation from the plate is presented to verify the proposed approach.

A Study on the Assignment of the Vibration Classes to the Power Transformers in Operation (154[kV])

  • Kim, Young-Dal
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.52-60
    • /
    • 2009
  • High reliability is essential for power transformers, and their fault causes are reportedly more related to mechanical causes than electrical ones. The transformer soundness judgment currently depends only on the electrical insulation characteristic and the chemical test of the insulation oil, so that there are few fundamental measures against the frequent mechanical damages and failures in transformers. The mechanical soundness judgment techniques are conducted through processes that include structural analysis and vibration resistance treatment during the manufacturing process of each manufacturer, but the vibration is not tested during the design, manufacturing, and operating processes since there are no detailed technical standards and procedures on the vibration problem, which are important in terms of maintenance. Therefore, in this study, vibration phenomena were measured from the 32 power transformers in operation in the substations under the Daejeon Power Transmission District Office of the Korean Electric Power Corporation (KEPCO). The vibration was measured at 24 sections ($6{\times}4$) on one side, and only the maximum values were selected from the measured vibration values. This was because the maximum vibration values more significantly affect the soundness of the transformer than the average vibration values. The vibration classes were given considering the maximum vibration based on ISO 10016-1 (2001).

Vibration Power Flow Analysis of Coupled Shell Structures (연성된 쉘 구조물의 진동 파워흐름해석)

  • Kim, Il-Hwan;Hong, Suk-Yoon;Park, Do-Hyun;Kil, Hyun-Gwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.352.2-352
    • /
    • 2002
  • In this paper, Power Flow Analysis (PFA) method has been applied to the prediction of vibration energy density and intensity of coupled shell structures in the medium-to-high frequency ranges. To consider the wave transformation at joint between shell elements, power transmission and reflection coefficients are investigated for various joint angles, and here Donnell-Mushtari thin shell theory has been used. (omitted)

  • PDF

Multi-dimensional vibration/noise isolation by vibration power analysis (다차원 진동/소음 절연을 위한 진동 파워 이용법)

  • Kim, Gwang-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.33-48
    • /
    • 2000
  • Limitations of the simple single degree of freedom vibration isolation theory in real applications are discussed and a theory of multi-dimensional vibration/noise isolation by power approach is introduced. Illustrations of the application to compressor of an air-conditioner are presented together with problems caused by approximations. Then possible sources of distortions in the vibration power estimation are looked into and some relevant research topics are suggested.

  • PDF