• Title/Summary/Keyword: vibration frequency

Search Result 6,200, Processing Time 0.036 seconds

Acoustic resonance by Inserting Anti-noise Baffle in the Tube Bank of Boiler of a Large Fossil Power Plant (대형석탄화력발전용 보일러 관군의 Anti-Noise Baffle 설치에 따른 음향공진)

  • Bang, Kyung-Bo;Kim, Cheol-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.178-183
    • /
    • 2004
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a large fossil power plant. The phenomena of acoustic resonance may arise when the vortex shedding frequency coincides with the acoustic natural frequency. In this system dominant frequency of vibration and noise was 37.5Hz. The $3^{rd}$ acoustic natural frequency calculated was 37.2 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance could occur. If system is the state of acoustic resonance, vibration and noise become large. In order to prevent acoustic resonance, anti-noise baffle should be installed in the tube bank. In the case of installing baffle, we should consider the number of baffle and the effect of acoustic mode due to baffle extension length. To do this, we did acoustic mode analysis. After installing anti-noise baffle, acoustic resonance was disappeared and vibration magnitude and noise level was reduced dramatically.

  • PDF

Vibration Reduction of an Air Cooled Heat Exchanger with Axial Flow Fan (축류송풍기 부착형 공냉식 열교환기의 진동 저감)

  • Jung, Goo-Choong;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.75-81
    • /
    • 2000
  • Vibration problems induced by an air cooled heat exchanger with axial flow fan were investigated during the operation of a petrochemical plant. Two different studies were done; one was experimental field test and the other was theoretical verification. To find main cause of the blade passing frequency of the fan after installing additional blockage board at the air inlet of the axial fan, the frequency spectrum was measured. The vibrations of the blade passing frequency became higher. The natural frequency of driving support of the heat exchanger was theoretically calculated. It was approximately equal to the blade passing frequency. During the normal operation of the plant, it was impossible to modify the structure of the driving support. Instead, the blade number was increased to reduce vibration level. It increased the ratio of the forcing frequency to the natural frequency of the driving support over the resonance region.

  • PDF

JND-based Mobile Phone Optimal Vibration Frequency (JND를 이용한 휴대폰의 최적 진동 주파수 설계)

  • Lee, Bongwang;Park, Hyunho;Myung, Rohae
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.30 no.1
    • /
    • pp.27-35
    • /
    • 2004
  • A study was conducted to investigate an optimal vibration frequency for mobile phones with just noticeable difference(JND). The just noticeable difference, Weber's law, is the minimum amount by which stimulus intensity must be changed in order to produce a noticeable variation in sensory experience. In order to find the optimal vibration frequency, sixteen frequencies ranged from 24Hz to 603Hz were selected. Subjects then wereasked to differentiate a pair of vibration frequencies. For the analysis, the psychometric function to determine the optimal vibration frequency and the logistic regression to validate the determined frequency were used. The results show that the 2nd order polynomial equations were best fitted for the JND psychometric function and the optimal mobile phone vibrations were determined at 140Hz, 151 Hz, and 160Hz. With the ogive-shaped psychometric function developed by the logistic regression, the results of this study was validated that the determined vibration frequencies (140Hz, 151 Hz, and 160Hz) were optimal mobile phone vibration frequencies.

Vibration Characteristics of the Pears in Corrugated Fiberboard Container for Packaging be stacked at Simulated Transportation Environment (모의 수송환경에서의 적재된 골판지 포장화물 내 배의 진동특성)

  • Jung, Hyun-Mo;Park, In-Sig;Kim, Man-Soo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.11 no.1
    • /
    • pp.11-16
    • /
    • 2005
  • Fruits are subjected to complex dynamic stresses in the transportation environment. During a long journey form the production area to markets, there is always some degree of vibration present. Vibration inputs are transmitted from the vehicle through the packaging to the fruit. Inside, these cause sustained bouncing of fruits against each other and container wall. These steady state vibration input may cause serious fruit injury, and this damage is particularly severe whenever the fruit inside the package is free to bounce, and is vibrated at its resonance frequency. The determination of the resonant frequencies of the fruit may help the packaging designer to determine the proper packaging system providing adequate protection for the fruit, and to understand the complex interaction between the components of fruit when they relate to expected transportation vibration inputs. The first frequency of the pear in packaged freight be stacked in resonance frequency band of the pear packaged freight was increased from the bottom to the top of the stack but the second frequency of that in resonance frequency band of the pear was decreased. This indicated that the high damage score of the pear in bottom tier in vibration test was due to higher acceleration level in resonance frequency band of the pear.

  • PDF

Experimental Study On Power Flow Analysis of Vibration of a Coupled Plate (연성 평판 진동에 대한 파워흐름해석법의 실험적 연구)

  • Lee, G.H.;Kil, H.G.;Hwang, S.G.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.797-800
    • /
    • 2006
  • The power flow analysis(PFA) can be effectively used to predict structural vibration in medium-to-high frequency ranges. In this paper, vibration experiment has been performed to observe the analytical characteristics of the power flow analysis of the vibration of a plate. In the experiment, the loss factor of the plate and the input mobility at a source point have been measured. The data for the loss factor has been used as the input data to predict the vibration of the plate with PFA. The frequency response functions have been measured over the surface of the plate. The comparison between the experimental results and the predicted results for the frequency responsefunctionshasbeenperformed.

  • PDF

Investigation of Transmission Characteristics of Tractor Seat Vibrations Using Vibration Path Analysis Method (VPA를 이용한 트랙터 좌석 진동의 전달 특성 구명)

  • 이주완;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.26 no.3
    • /
    • pp.237-244
    • /
    • 2001
  • This work was intended to investigate the effect of vibration transmission paths on the ride vibration of tractor during the rotavating and transporting operations by applying the vibration path analysis method. Accelerations at the cab mounts were measured during the rotavating and transporting operations. Ride vibrations at the sear were than calculated using the measured accelerations at the cab mounts, and the frequency response functions and inertances between the seat and cab mounts, which were derived experimentally by the impact hammer test in static condition. The human sensitivity to vibration frequency was also taken into consideration for the calculation of ride vibrations at the 1/3 octave center frequencies in the frequency domain. Vibrations transmitted through rear cab mounts affected more significantly the ride vibration of tractor. The peak accelerations at the seat occurred at the frequencies of the engine and crank speed, and the frequency induced by tire lugs on the road transportation. It was found that the rear cab mounts should be improved in order to reduce the ride vibrations more effectively.

  • PDF

Effects of hand vibration on involuntary muscle contraction

  • 박희석
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1994.04a
    • /
    • pp.394-398
    • /
    • 1994
  • The aim of the present study was to determine the influence of vibration frequency and muscle contraction level at constant vibration displacement amplitudes on a commonly observed motor response elicited by local vibratory stimulation, i.e., the Tonic Vibration Reflex (TVR). Vibration was applied to the distal tendons of the hand flexor muscles. Changes in activity of the hand flexor and extensor muscles were analyzed as a function of the vibration frequency (40-200 Hz), displacement amplitude(200.mu.m and 300.mu.m peak-to-peak), and the initial contraction level of the flexor muscles (0%, 10%, and 20% of the maximal voluntary contraction: MVC). The main results indicate that the TVR increases with vibration frequency up to 100-150 Hz and decreases beyond, and the TVR attains its maximum at 10% MVC. It appears that high frequency vibration tends to induce less muscle/tendon stress. Such a result is of particular importance for the design of handheld vibrating tools.

Idle Vibration Development Procedure of 4WD SUV (SUV차량의 Idle 성능 개발)

  • 최승우;이남영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.120-124
    • /
    • 2003
  • NVH issue at idle condition is one of the major concerns of Passenger and Commercial Vehicle including Sports Utility Vehicle Especially steering wheel vibration at idle condition is a very complex problem and affected by firing frequency of the engine, stiffness of a steering wheel system and the body to which the steering wheel system is attached. To avoid vibration mode coupling between each system of a vehicle, experimental and analytical method has been used at the pre-prototype stage. The resonance frequency of the body and the frame has been decoupled by CAE and the resonance frequency of steering wheel system has been set in between the 1st bending frequency of body and frame. These Results has been used as design guidelines tot the prototype drawing stage. The experimental verification of tile modified pre-prototype vehicle shows good results of the vibration mode decouple. Modal test of prototype vehicle also confirms the vibration mode decouple between each system.

  • PDF

A Study on the Control of the Floor Vibration in a Research Building (연구소(硏究所) 건물(建物)의 슬래브 진동(振動) 성능개선(性能改善) 연구(硏究))

  • Baik, In-Whee;Kang, Ho-Sub;Sohn, Young-Kyoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.3
    • /
    • pp.75-82
    • /
    • 2007
  • A vibration in the building occurs by influences of the facility equipment and the structural system. As the building recently becomes higher and bigger, the vibration in the floor slab is issued. Specially, the vibration with $4{\sim}8Hz$ frequency is harder to control than any other range of frequency. This vibration easily affects human sensibility and often makes the resonance phenomenon by corresponding with the floor slab's natural frequency when people and heavy equipments move. Moreover, the permission regulations for the vibration of the building are established by building's purposes. However, it is not subdivided in detail and sometimes ambiguous to each client. Even though the vibration could cause negative influences in a research building, there is not the vibration criterion for a research building. Therefore, it is necessary to set up its own vibration criterion with the client before building and to keep checking this vibration criterion under the construction. This study proposes the reasonable control methods and the vibration criterion for floor slab's vibration which are adapted to the R4-project. The R4-project is a research building and a high-rise building also. Accordingly, this study could help to the next similar project in the design and the construction phase.

Development of a Low Frequency Vibration Shaker Using Force Frequency Shifting (가진주파수 이동현상을 이용한 저주파 가진기의 개발)

  • ;L. L. Koss
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.4
    • /
    • pp.274-280
    • /
    • 2003
  • If a sinusoidal excitation force moves back and forth along a structure with a certain frequency, the structure will be excited with the difference frequency of these two frequencies. A low frequency vibration shaker has been developed using this force frequency shifting without actually moving a shaker The shaker consists of an ordinary eccentric mass shaker, a plate, constant springs, and time varying dampers. The dampers are turned on and off in a sequential manner to simulate a traveling slide of an excitation force. The operation of the shaker is simulated by solving the equations of motion of the shaker. Characteristics of the shaker have been found and they can be utilized to design efficient low frequency shakers.