A Study on the noise & vibration properities of Fan Filter Unit and evaluation of effect to Clean Room (Fan Filter Unit 소음ㆍ진동 특성과 청정실에 미치는 영향성 평가에 관한 연구)

  • 백재호;손성완
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.778-784
    • /
    • 2002
  • FFU are used increasingly by the microeleceronics industry to provide clean recirculating air for the fabrication of integrated circuits and laminar flow air. There may be several hundred ffu in a large cleanroom, covering 100% of the ceiling area. Hence, there is of often knowledge in the inside and outside of the country the flu give rise to noise & vibration trouble to microelectronics industry. Noise & Vibration control for satisfication about noise & vibration criteria in TFT-LCD factory cleanroom be in need of exact noise & vibration data of accurence from utility & equipment that can be exert a bad influence upon cleanroom. In this pater, hence we found out noise and vibration properities of ffu by using experimental method. And, we performed noise & vibration analysis about noise it vibration level in cleanroom using semiempirical method for quantative approach about noise & vibration level in cleanroom.

  • PDF

Vibration Response Analysis of the Military Vehicle by Road Test (군용차량 주행 진동응답 분석)

  • Shin, Dong-Jun;Lee, Jong-Hak;Kang, Young-Sik;Choi, Ji-Ho;Kang, Dong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.262-266
    • /
    • 2014
  • Military vehicle equipped with an antenna and a shelter for operating radar has a vibration exposure during driving time. This vibration would have influence on structure of military vehicle critically. In this paper, driving stability of the military vehicle is obtained through the vibration response analysis. And, vibration level of the military vehicle satisfied the military vibration specification through analysis and comparing the MIL-STD-810G. PSD and Grms data obtained by road test can be used for vibration test specification of cabinets and electronic equipment in shelter.

  • PDF

A study on the vibration durability test for the energy harvesting part of vehicle (에너지 활용 부품의 진동내구 평가기법 연구)

  • Ju, Hyung-Jun;Kim, Chan-Jung;Lee, Gee-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.587-588
    • /
    • 2014
  • Studies that the vehicle exhaust system applied by the TEG(thermal electric generator) are actively in progress in order to improve the fuel efficiency of the vehicle. Vehicle exhaust system is on a poor vibration condition, it is susceptible to TEG. This paper is about the development of vibration durability test of TEG mounted on a vehicle exhaust system. Vehicle driving tests are performed to measure the vibration condition of the vehicle exhaust system. The vibration durability test mode of TEG is evaluated using equivalent vibration energy method. The vibration durability tests of TEG are performed using the multi-axial vibration simulation table.

  • PDF

Evaluation of idle vibration beated by cooling fan imbalance (팬 작동에 따른 비팅성 아이들 진동 평가)

  • Park, Jinhan;Ahn, Sejin;Jeong, Weuibong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.247-249
    • /
    • 2014
  • The beating phenomenon occurs because of various causes, when idle vibration was happened. In this study, the beating phenomenon was divided into several parameters and controlled by the parameter. It was hypothesized that the beating parameter is related to discomfort of idle vibration. The three-down one-up method was performed for evaluating discomfort of controlled vibrations, which is widely used in the field of psychophysics. As a result in pilot test, a subject responds beating vibration more discomfort than normal idle vibration. In the future, the study will be implemented to know how much the parameters of beating signal affect to the discomfort at idle vibration in passenger vehicle.

  • PDF

A evaluation and countermeasure for blast-induced vibration of micro electronic production facility based on experimental method (실험적 방법에 의한 발파작업으로 기인하는 인접 초정밀 생산장비 FAB에 미치는 진동 영향성 평가 및 제어대책)

  • Son, Sung-Wan;Park, Sang-Gon;Lee, Hong-Ki;Chun, Jong-Kun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.875-878
    • /
    • 2006
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function, therefore, it is very important to predict precisely vibration environment of microelectronics production facility due to adjacent blast work. However, it is not easy to evaluate a quantitative vibration response of structure due blast because it can be determined by the characteristics of vibration sources, propagation through rock and soil and dynamic properties of building. In this paper, vibration influence evaluation of micro-electronic Production building induced from adjacent blast activity was performed by real measurement data obtained on ground and structure at same time. And blast vibration allowable limit on ground was supposed by measurement data analysis in order to avoid operation error of precision equipments

  • PDF

An Experimental Study of Tridirectional Vibration of Helical Gears with Different Contact Ratios (물림률이 다른 헬리컬 기어들의 3방향 진동의 실험적 연구)

  • Park, Chan-Il;Jeon, Don-Hyuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.2 s.119
    • /
    • pp.177-184
    • /
    • 2007
  • The purpose of this study is to investigate experimentally the characteristics of rotational, radial, and axial vibration for helical gears with different contact ratios. For this purpose, the gear box is specially designed and manufactured. Two helical gears with different face widths and reduction ratios are investigated. The gear vibration in each direction is measured by accelerometers attached to the gear body. Rotational vibration is the highest and radial vibration is the lowest in the gear frequencies. While the increase of rotational speed increases gear vibration, it does not always increase with torque. It is not also linearly related to the contact ratio. In addition, axial vibration is not proportional to rotational vibration.

A Study on Active Vibration Isolation Using Electro-Magnetic Actuator (전자기력을 이용한 능동제진에 관한 연구)

  • 손태규;김규용;박영필
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1169-1181
    • /
    • 1994
  • Vibration isolation of mechanical systems, in general, is achieved through passive or active vibration isolators. Passive vibration isolator has an inherenrt performance limitation. Whereas, active vibration isolator provides significantly superior vibration-isolation performance at the cost of energy sources and sensors. Recently, in many cases, such as suspension system, precision machinery ... etc, active isolation system outweighs its limitation. Therefore, many studies, researches, and applications are carried out in this field. In this study, vibration-isolation characteristics of an active vibration control system using electromagnetic force actuator are investigated. Several control algorithms including optimal, feedforward are used for active vibration isolation. From the experimental results of each algorithm, effective control algorithms for this active vibration-isolation system are proposed.

The Study of Muscle Contraction Effect of Vibration Exercise Device Using Surface Electromyography (표면근전도를 이용한 진동운동기의 근수축 효과에 관한 연구)

  • Baik, Sung-Kook;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.55-63
    • /
    • 2006
  • The purpose of this study was to investigate the effects of vibration exercise using surface electromyography. Seven male collegiate wrestlers were participated in this study. Each subject stood on the platform and the vibration was induced for 1min. WEMG8 EMG system was used to record muscle activity from Vastus lateralis, Biceps Femoris, Tibialis Anterior, and Gastrocnemius. The EMG data were sampled for 30 sec. during non-vibration and vibration half squat position, respectively. The raw data were band pass filtered to remove noise and full wave rectified Paired sample t-test were performed to see the differences of maximum and average EMG between non-vibration and vibration trials. The results indicated that vibration produced much more muscle contraction than that of non-vibration trial for all selected muscles even though the significant difference was found only from Biceps Femoris. This phenomenon was due to the individual differences so care must be taken to evaluate vibration intensity and position before personal training.

A Study on Measurement and Assessment of Local Vibration by Walking-type Cultivator (보행형 관리기의 국소진동 측정과 평가에 관한 연구)

  • Noh, Kyoung-Kyu;Park, Peom
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.1
    • /
    • pp.67-73
    • /
    • 2009
  • The goal of this study was to assess the level of vibration in an walking-type cultivator, and to provide a basic information to manage the vibration exposure for farmers. The latent periods of vibration-induced white finger (VWF) were assessed through analyzing the vibration levels and frequency characteristics. Also, vibration acceleration levels based on the daily vibration exposure duration was suggested. The latent periods of vibration-induced white finger were assessed by ISO 5349 method. The latent periods were 4.5 and 10.1 years at 10% and 50% of farmer group, respectively. Also, under ACGIH (American Conference of Governmental Industrial Hygienists) standard, daily vibration exposure duration at 6.7 m/s2 of vibration acceleration has to be less than 4 hours. Therefore, education that maximum working hours should be less than 4 continuous hours is necessary for the operators of walking-type cultivators.

Vibration Characteristics and Prediction of Railroad Track Supporting Structures (궤도지지구조물의 진동특성과 예측)

  • 황선근;엄기영;고태훈
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.2
    • /
    • pp.51-61
    • /
    • 2000
  • In this study, field measurements of vibration on the structures supporting railroad track were performed. The vibration data obtained were analyzed to find out any correlation between its magnitude and several factors such as type of bridges, distance from the track, type of train, frequency characteristics, etc. As a result, the magnitude of vibration turned out to be the highest in the steel bridge, the concrete bridge and steel-concrete combined bridge were the next in descending order. It was also found that the dynamic characteristics of ground were the most important factors among several affecting vibration near by the railroad track. And the empirical ground vibration estimation equation for estimating ground vibration was developed. The proposed equation with respect to distances from the railroad could be easily used for the estimation of ground vibration at the residential areas nearby the track.

  • PDF