• 제목/요약/키워드: vibrating device

검색결과 67건 처리시간 0.026초

호흡기를 통한 약액 전달을 위한 진세노사이드 초미세입자 분무장치 제작 (Fabrication of an ultra-fine ginsenoside particle atomizer for drug delivery through respiratory tract)

  • 이병철;박진수;양웅모
    • 대한융합한의학회지
    • /
    • 제2권1호
    • /
    • pp.5-12
    • /
    • 2021
  • Objectives: The purpose of this study is to fabricate an ultra-fine ginsenoside particle atomizer that can provide a new treatment method by delivering ginsenoside components that have a therapeutic effect on respiratory diseases directly to the lungs. Methods: We fabricated the AAO vibrating mesh by using the micromachining process. The starting substrate of an AAO wafer has a 350nm pore diameter with 50㎛ thickness. A photomask having several 5㎛ opening holes with a 100㎛ pitch was used to separate each nanopore nozzle. The photoresist structure was optimized to pattern the nozzle area during the lift-off process precisely. The commercial vibrating mesh was removed from OMRON's NE-U100 product, and the fabricated AAO vibrating mesh was installed. A diluted sample of 20mL with 30% red ginseng concentrate was prepared to atomize from the device. Results: As a result of liquid chromatography analysis before spraying the ginsenoside solution, ginsenoside components such as 20S-Rg3, 20R-Rg3, and Rg5 were detected. After spraying through the AAO vibrating mesh, ginsenosides of the same component could be detected. Conclusion: A nutrient solution containing ginsenosides was successfully sprayed through the AAO vibrating mesh with 350 nm selective pores. In particular, during the atomizing experiment of ginsenoside drug solution having excellent efficacy in respiratory diseases, it was confirmed that atomizing through the AAO vibrating mesh while maintaining most of the active ingredients was carried out.

Effectiveness of an extraoral cold and vibrating device in reducing pain perception during deposition of local anesthesia in pediatric patients aged 3-12 years: a split-mouth crossover study

  • Ashveeta Shetty;Shilpa S Naik;Rucha Bhise Patil;Parnaja Sanjay Valke;Sonal Mali;Diksha Patil
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권6호
    • /
    • pp.317-325
    • /
    • 2023
  • Background: Local anesthetic injections may induce pain in children, leading to fear and anxiety during subsequent visits. Among the various approaches recommended to reduce pain, one is the use of a Buzzy BeeTM device that operates on the concept of gate control theory and distraction. The literature regarding its effectiveness during the deposition of local anesthesia remains limited; hence, the aim of the present study was to determine the efficacy of extraoral cold and vibrating devices in reducing pain perception during the deposition of local anesthesia. Methods: A split-mouth crossover study in which 40 children aged 3-12 years requiring maxillary infiltration or inferior alveolar nerve block for extractions or pulp therapy in the maxillary or mandibular posterior teeth were included. The control intervention involved the application of topical anesthetic gel for one minute (5% lignocaine gel), followed by the administration of local anesthetic (2% lignocaine with 1:80,000 adrenaline) at a rate of 1 ml/ minute. Along with the control protocol, the test intervention involved using the Buzzy BeeTM device for 2 minutes before and during the deposition of the local anesthetic injection. The heart rate and face, legs, arms, cry, and consolability revised (FLACC-R) scale scores were recorded by the dentist to assess the child's pain perception. Results: The mean age of the participants in Group A and Group B was 7.050 ± 3.12 years and 7.9 ± 2.65 years respectively. A reduction in the mean heart rate and FLACC-R score was observed during the deposition of local anesthetic solution in the tissues when the Buzzy BeeTM was used in both groups at different visits in the same subjects (P < 0.05) The Buzzy BeeTM device was effective in reducing the heart rate and FLACC-R scores when used during maxillary infiltration and inferior alveolar nerve block local anesthesia techniques (P < 0.05). Conclusion: The use of extraoral cold and vibrating devices significantly reduces pain perception during local anesthetic deposition in pediatric patients. Considering the results of this study, the device may be incorporated as an adjunct in routine dental practice while administering local anesthesia in children.

Zigbee 무선통신 네트워크 기반 변형측정 시스템 설계 및 개발 (Design and Development of Strain Measurement System Based on Zigbee Wireless Network)

  • 김상석;박장식;고석조;노희종
    • 한국전자통신학회논문지
    • /
    • 제7권3호
    • /
    • pp.585-590
    • /
    • 2012
  • 본 논문에서는 구조물의 안전한 관리를 위하여 진동현방식 센서를 이용하여 변형을 측정하고 Zigbee 무선 네트워크를 통하여 원격 모니터링할 수 있는 시스템을 구현하였다. 구현한 변형측정기는 진동현방식 센서를 구동하여 출력되는 신호의 주파수를 측정하여 변형을 계산하고, 변형 측정에 있어 요구되는 온도 보상을 위한 온도를 측정한다. 2축 가속도센서를 이용하여 변형의 방향을 측정할 수 있다. 개발한 변형측정기에는 보다 효율적인 모니터링을 위하여 유무선 통신 기능이 있다. 실험을 통하여 개발한 진동현방식 변형측정 시스템이 원격모니터링에 효과적임을 확인한다.

차분 진동형 가속도계 전기적 모델링 및 실험적 검증 (Electromechanical Modeling and Experimental Verification of Differential Vibrating Accelerometer)

  • 이정신;임재욱
    • 한국항공우주학회지
    • /
    • 제39권6호
    • /
    • pp.517-525
    • /
    • 2011
  • 차분 진동형 가속도계는 입력 가속도에 따른 공진 주파수의 변화를 감지하는 공진형 센서이다. 이 때 가속도계 전기적 동역학의 수학적 모델링 및 구조 특성의 실험적 검증이 정밀한 제어기 및 높은 양질계수를 가지는 구조 설계에 앞서 필요하게 된다. 본 논문에서는 차분 진동형 가속도계의 공진자, 전극 모듈 및 전치증폭기 등의 전기적 모델링을 제시한다. 이러한 모델링 기법은 공진 주파수, 유효 질량, 유효 강성, 양질 계수 등을 측정함으로써 실험적으로 검증된다. 또한 모델링을 통해 예측된 진폭과 측정된 전치증폭기 출력의 직접적인 비교는 본 연구의 유효성을 보여준다.

스트레인 게이지 변위 추정기를 사용한 유동공진 가진기 개발 (The Development of Vibration Exciter Using Strain Displacement Estimator for Flow Resonance)

  • 최재혁;남윤수
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.125-132
    • /
    • 2001
  • Heat dissipation technology using flow resonant phenomenon is a kind of new concept in heat transfer area. A vibration exciter is needed to generate air turbulence which has the natural shedding frequency of heat system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator. An analytical dynamic model for this mechanical vibration exciter is presented and its' validity is verified by the comparison with experimental data. Values of some unknown system parameters in the analytic model are estimated through the system identification approach. Based on this mathematical model, the vibration exciter using strain displacement estimator is developed. And in the experiment, the feedback control is used. During the experimental verification phase, it turns out the high modal resonant characteristics of vibrating plate are the major barrier against obtaining a high bandwidth vibration exciter.

  • PDF

유동공진을 위한 가진기 설계 및 평가 (Design and Evaluation of a Vibration Exciter for the Flow Resonance)

  • 남윤수;최재혁
    • 한국정밀공학회지
    • /
    • 제18권6호
    • /
    • pp.141-147
    • /
    • 2001
  • A heat dissipation technology using flow resonant phenomenon is a kind of new concept in heat transfer area. A vibration exciter is needed to generate an air turbulence which has the natural shedding frequency of a heat system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator. An analytical dynamic model for this mechanical vibration exciter is presented and its validity is verified by the comparison with experimental data. Values of some unko주 system parameters in the analytic model are estimated through the system identification approach. based on this mathematical model, a high bandwidth vibration exciter is designed using feedback control. During the experimental verification phased, it turns out the high frequency modal resonant characteristics of vibrating plate are the major barrier against obtaining a high bandwidth vibration exciter.

  • PDF

유동공진을 위한 가진기 설계 (Vibration Exciter Design for Flow Resonance)

  • 남윤수;최재혁
    • 산업기술연구
    • /
    • 제20권B호
    • /
    • pp.125-130
    • /
    • 2000
  • Heat dissipation technology using flow resonant phenomenon is a kind of new concept in heat transfer area. A vibration exciter is needed to generate air turbulence which has the natural shedding frequency of heat system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator. An analytical dynamic model for this mechanical vibration exciter is presented and its validity is verified by the comparison with experimental data. Values of some unknown system parameters in the analytic model are estimated through the system identification approach. Based on this mathematical model, a high bandwidth vibration phase, it turns out the high modal resonant characteristics of vibrating plate are the major barrier against obtaining a high bandwidth vibration exciter.

  • PDF

A Study of Design of Hollow Fiber Membrane Modules for using in Artificial Lung by the PZT Actuator

  • Kim, Gi-Beum;Kim, Seong-Jong;Hong, Chul-Un;Lee, Yong-Chul;Kim, Min-Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권4호
    • /
    • pp.143-153
    • /
    • 2006
  • The purpose of this work was to assess and quantify the beneficial effects of gas exchange, while testingto the various frequencies of the sinusoidal wave that was excited by the PZT actuator, for patients suffering from acute respiratory distress syndrome (ARDS) or chronic respiratory problems. Also, this paper considered a simulator to design a hollow type artificial lung, and a mathematical model was used to predict a behavior of blood. This simulation was carried out according to the Montecarno's simulation method, anda fourth order Runge-Kutta method was used to solve the equation. The experimental design and procedure are then applied to the construction of a new device to assess the effectiveness of the membrane vibrations. As a result, the vibration method is very effective in the increase of gas transport. The gas exchange efficiency for the vibrating intravascular lung assist device can be increased by emphasizing the following design features: consistent and reproducible fiber geometry, and most importantly, an active means of enhancing convective mixing of water around the hollow fiber membranes. The experimental results showed the effective performance of the vibrating intravascular lung assist device. Also, we concluded that important design parameters were blood flow rates, fiber outer diameter and oxygen pressure drop. Based on the present results, it was believed that the optimal level of blood flow rates was 200$cm^3$/min.

Comparative evaluation of efficacy of external vibrating device and counterstimulation on child's dental anxiety and pain perception during local anesthetic administration: a clinical trial

  • Sahithi, Varada;Saikiran, Kanamarlapudi Venkata;Nunna, Mahesh;Elicherla, Sainath Reddy;Challa, Ramasubba Reddy;Nuvvula, Sivakumar
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제21권4호
    • /
    • pp.345-355
    • /
    • 2021
  • Background: This study aimed to evaluate the efficacy of external vibrating devices and counterstimulation on a child's dental anxiety, apprehension, and pain perception during local anesthetic administration. Methods: This was a prospective, randomized, parallel-arm, single-blinded interventional, clinical trial. One hundred children aged 4-11 years, requiring pulp therapy or extraction under local anesthesia (LA), were recruited and allocated equally into two groups (1:1) based on the interventions used: Group BD (n = 50) received vibration using a Buzzy® device {MMJ Labs, Atlanta, GE, USA} as a behavior guidance technique; Group CS (n = 50) received counterstimulation for the same technique. Anxiety levels [Venham's Clinical Anxiety Rating Scale (VCARS), Venham Picture Test (VPT), Pulse oximeter {Gibson, Fingertip Pulse Oximeter}, Beijing, China)] were assessed before, during, and after LA administration, while pain perception [Wong-Baker Faces Pain Rating Scale (WBFPS), Visual Analogue Scale (VAS)] was evaluated immediately after injection. Statistical analysis was performed using the Student's t-test to assess the mean difference between the two groups and the repeated measures ANOVA for testing the mean difference in the pulse rates. Statistical significance was set at P < 0.05. Results: Significant differences in mean pulse rate values were observed in both groups. In contrast, the children in the BD group had higher diminution (P < 0.05), whereas the mean VCARS and VPT scores were conspicuous (P < 0.05). Based on the mean WBFPS and VAS scores, delayed pain perception after LA injection was more prominent in the BD group than in the CS group. Conclusion: External vibration using a Buzzy® device is comparatively better than counterstimulation in alleviating needle-associated anxiety in children requiring extraction and pulpectomy.

마늘파종기 개발에 관한 연구 (II) - 마늘파종기의 설계요인 - (Development of a Garlic Clove Planter (II) - Design factors for a garlic clove planter -)

  • 박원규;최덕규;김영근
    • Journal of Biosystems Engineering
    • /
    • 제27권6호
    • /
    • pp.547-556
    • /
    • 2002
  • Upright positioning of garlic cloves in mechanical planting has been considered as an essential process because pose of garlic affects not only initial budding and rooting of garlics but quality and yield. Due to the geometrical uniqueness and irregularity of garlic cloves in shape, manual planting operation has been conducted. The overall objective of this research was to determine design factors for designing a garlic clove planter The results are summarized as follows : 1. A vibrating-type clove-metering device was designed and tested. Effects of tilted angle of metering plate and magnitude of vibration on metering performance were investigated. The successful planting rates of the metering device were 96.7% for Hanji varieties. 2. Clove upright-positioning device, posture inducer was designed and tested. When the clearance between the hoppers was set at 4mm, the rates of upright positioning of the device were 92.2% for with Hanji varieties. 3. Optimum metering performance was observed at the plate tilted angle of 80。 with the posture type positioning device.