• 제목/요약/키워드: vertical velocity

검색결과 1,232건 처리시간 0.024초

수직벽 후방박리영역 감소를 위한 맥동제트의 최적화 연구 (Optimization study of pulsating jet for reducing the separation bubble behind the vertical fence)

  • 최영호;강인수;김형범
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.185-188
    • /
    • 2008
  • In this study, we experimentally investigated that the optimization of pulsating jet to reduce the separated flow region behind the vertical fence. The vertical fence was submerged in the turbulent boundary layer in the circulating water channel and we applied phase averaged PIV method to measure the instantaneous velocity fields around the fence. One cycle of pulsating jet is divided into 20 phases and grabbed total 200 instantaneous velocity fields at each phase. The experiments were performed by varying the frequency, maximum jet velocity and the shape of pulsating jet wave. Pulsating jet was precisely made by piston-type pump controlled by the computer. The obtained results were compared with normal fence flow. From this study, we found there is the specific frequency which is effective in reducing the reattachment region.

  • PDF

수직형 풍력터빈 익형의 동특성 분석 (Study for Dynamic Stall Characteristics of Vertical Axis Wind Turbine Airfoil)

  • 김철완;조태환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.478-481
    • /
    • 2009
  • As a first step for aerodynamic analysis of vertical axis wind turbine, dynamic stall characteristics of airfoil was investigated. Dynamic stall of wind turbine airfoil is caused by severe variation of angle of attack and relative velocity of flow around airfoil. Angle of attack and relative velocity can be expressed with tip speed ratio. Variation of angle of attack is strongly dependent on the tip speed ratio. For tip speed ratio, 1.4 and free stream velocity, 15m/s, dynamic stall characteristics of wind turbine airfoil is compared with those of oscillating airfoil having same angle of attack variation.

  • PDF

근접장 발파진동에서 진동속도와 진동레벨 (The Vibration Velocity and Vibration Level of Near-field Blasting Vibration in an Urban Blasting Site)

  • 이연수;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.766-771
    • /
    • 2005
  • To compare blasting vibration at blasting construction field in urban area, the vibration level (dB(V)) and vibration velocity (cm/sec) on the ground and the structure of buildings due to the differences of the measuring sites from the blasting source is investigated and the difference between the measured vertical vibration level and the calculated vibration level by using vibration velocity PVS and the correlation between vibration velocity and vibration level and is studied in the thesis.

  • PDF

수직관 내 순수 증기의 층류 액막 응축 모델 (Laminar Film Condensation Model of Pure Steam in a Vertical Tube)

  • 김동억
    • 한국유체기계학회 논문집
    • /
    • 제17권3호
    • /
    • pp.33-40
    • /
    • 2014
  • In this study, a new model for calculating the liquid film thickness and condensation heat transfer coefficient in a vertical condenser tube is proposed by considering the effects of gravity, liquid viscosity, and vapor flow in the core region of the flow. In order to introduce the radial velocity profile in the liquid film, the liquid film flow was regarded to be in Couette flow dragged by the interfacial velocity at the liquid-vapor interface. For the calculation of the interfacial velocity, an empirical power-law velocity profile had been introduced. The resulting liquid film thickness and heat transfer coefficient obtained from the proposed model were compared with the experimental data from other experimental study and the results obtained from the other condensation models. In conclusion, the proposed model physically explained the liquid film thinning effect by the vapor shear flow and predicted the condensation heat transfer coefficient from experiments reasonably well.

수직벽화재의 수치 시뮬레이션 I. 수직벽 난류자연대류 (Numerical Simulation of Vertical Wall Fires I. Turbulent Natural Convection Along Vertical Wall)

  • 박외철;아노드 트루베
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.181-187
    • /
    • 2008
  • 수직벽 화재의 연구에 사용할 전산유체역학 시뮬레이터를 검증하기 위해 수직벽 자연대류의 수치 시뮬레이션을 수행하였다. 높이 4m의 등온 수직벽에 형성된 난류 경계층에서의 속도 및 온도 분포의 계산치를 측정치와 비교하였다. 시뮬레이터에 포함된 매개변수의 기본 값을 그대로 적용한 경우, 경계층 유동이 층류로 나타남에 따라 난류 자연대류를 예측하는데 실패하였다. 매개변수의 조사를 통해 격자크기 $\Delta$x=5mm, ${\Delta}y={\Delta}z=10mm$와 대와동모사(large eddy simulation)의 스마고린스키 상수(Smagorinsky constant) $C_s$=0.1을 선정하였다. 난류혼합이 미흡하였지만, 벽면근처에서의 속도분포와 최대속도, 그리고 난류 경계층 내 온도분포가 실험과 잘 일치하였다.

조건이 다른 수직 평형 평판에서 혼합대류 열전달 (Mixed Convection Heat Transfer from Two Vertical Parallel Plates with Different Conditions)

  • 김상영;정한식;권순석
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.243-252
    • /
    • 1992
  • A mixed convection heat transfer from two vertical parallel plates has been studied numerically by the finite difference method. Effects of the Grashof number, the relative length, $L_2/L_1$. the dimensionless temperature ratio, ${\Phi}_2/{\Phi}_1$ and the dimensionless plate spacing, $b/L_1$ are examined for the heat transfer. Independent of the Grashof numbers and $L_2/L_1$, the dimensionless vertical velocity distributions skewed on the left plate as ${\Phi}_2/{\Phi}_1$ decreased. The dimensionless vertical velocity distribution for $Gr/Re^2=1$ and ${\Phi}_2/{\Phi}_1=1.0$ is skewed to the right plate $L_2/L_1=0.5$, symmetric at $L_2/L_1=1.0$ and skewed to the left plate at $L_2/L_1=1.5$. But for $Gr/Re_2=10.0$ and ${\Phi}_2/{\Phi}_1=1.0$ reversed velocity patterns are obtained. Regardless of the Grashof numbers and $L_2/L_1$, the mean Nusselt nembers on the inside surface of the left plate decreases and those of the right inside surface increases as ${\Phi}_2/{\Phi}_1$ increases. Temperature, velocity and mean Nusselt number distributions are apparently not affected by $L_2/L_1$.

  • PDF

종방향대류 및 고액밀도차가 고려된 접촉융해에 대한 해석해 (An analytical solution for the close-contact melting with vertical convection and solid-liquid density difference)

  • 유호선;홍희기;김찬중
    • 대한기계학회논문집B
    • /
    • 제21권9호
    • /
    • pp.1165-1173
    • /
    • 1997
  • The steady state close-contact melting phenomenon occurring between a phase change material and an isothermally heated flat plate with relative motion is investigated analytically, in which the effects of vertical convection in the liquid film and solid-liquid density difference are incorporated simultaneously. Not only the scale analysis is conducted to estimate a priori qualitative dependence of system variables on characteristic parameters, but also an analytical solution to a set of simplified model equations is obtained to specify the effects under consideration. These two results are consistent with each other, in that the vertical convection affects both the solid descending velocity and the film thickness, and that the density difference alters only the solid descending velocity. While the effect of vertical convection can be characterized conveniently by a newly introduced temperature gradient factor which asymptotically approaches the unity/zero with decreasing/increasing the Stefan number, that of density difference is represented by the liquid-to-solid density ratio. It is shown that the solid descending velocity depends linearly on the density ratio, and that the ratios of solid descending velocity, film thickness and friction coefficient to the conduction solution are proportional to 3/4, 1/4 and -1/4 powers of the temperature gradient factor, respectively. Also, established is the fact that the effect of convection can be legitimately neglected in the analysis for the range of the Stefan number less than 0.1.

달리기 시 발의 인체측정학적 변인과 운동역학적 변인의 관계 (The Relationship between Anthropometric Parameters of the Foot and Kinetic Variables during Running)

  • Lee, Young Seong;Ryu, Jiseon
    • 한국운동역학회지
    • /
    • 제29권3호
    • /
    • pp.173-183
    • /
    • 2019
  • Objective: The aim of this study was to investigate the correlation coefficients between anthropometric parameters of the foot and kinetic variables during running. Method: This study was conducted on 21 healthy young adults (age: $24.8{\pm}2.1yes$, height: $177.2{\pm}5.8cm$, body mass: $73.3{\pm}7.3kg$, foot length: $256.5{\pm}12.3mm$) with normal foot type and heel strike running. To measure the anthropometric parameters, radiographs were taken on the frontal and sagittal planes, and determined the length and width of each segment and the navicular height. Barefoot running was performed at a preferred velocity ($3.0{\pm}0.2m/s$) and a fixed velocity (4.0 m/s) on treadmill (Bertec, USA) in order to measure the kinetic variables. The vertical impact peak force, the vertical active peak force, the braking peak force, the propulsion peak force, the vertical force at mid-stance (vertical ground reaction when the foot is fully landed in mid-stance or at the point where the weight was uniformly distributed on the foot) and the impact loading rate were calculated. Pearson's correlation coefficient was used to investigate the relationship between anthropometric variables and kinetical variables. The significance level was set to ${\alpha}=.05$. Results: At the preferred velocity running, the runner with longer forefoot had lower active force (r=-.448, p=.041) than the runner with short forefoot. At the fixed velocity, as the navicular height increases, the vertical force at full landing moment increases (r= .671, p= .001) and as the rearfoot length increases, the impact loading rate decreases (r=- .469, p= .032). Conclusion: There was a statistically significant difference in the length of fore-foot and rearfoot, and navicular height. Therefore it was conclude that anthropometric properties need to be considered in the foot study. It was expected that the relationship between anthropometric parameters and kinetical variables of foot during running can be used as scientific criteria and data in various fields including performance, injury and equipment development.

사범계 체육전공 대학생 물구나무서기 동작의 운동학적 분석 (A Kinematics Analysis of Handstand of University Students Majoring in Physical Education)

  • 김윤지;소재무;여홍철
    • 한국운동역학회지
    • /
    • 제16권4호
    • /
    • pp.21-30
    • /
    • 2006
  • The purpose of the study is to search for the possibility of the application of kinematics analysis to physical education at schools and expand its scope of application. This study chose 9 college students majoring in physical education and classified them into type A group who can make the straight, vertical handstand, type B group whose waist is bent, type C group who cannot handstand completely. The center of mass, distance between hand and leg, and the angle and angular velocity of each joint were obtained. The result of this study is this. 1. The time for CM showed 6:4 for A group and 5:5 for B and C groups. The distance between hand and foot in the event 3 was 44% of the height for A group, and 41% for B and C groups. A Group showed the higher CM positional significant difference, it was vertically direction below the hip joint at front. For significant difference of the B Group showed horizontal and vertical velocity of the CM, the highest vertical was obtained in phase 3. The difference of angle of shoulder join in the flexion/extension was showed gradually extension event 2 and the height angular velocity was at phase 3 in the A group. 2 The analysis of the handstand motion revealed that the phase 3, but the maintenance of posture start part the handstand is also very important. Through these results, this study confirmed that the time for phase of the CM, horizontal and vertical positions, velocity, the distance between hands and foot, and the difference of the angle and angular velocity of hip joint and shoulder joint can be set as the variables of analysis. It was also definite cause that the handstand motions of college students majoring in physical education had many difference in performance.

수직 배연구의 자연배연 성능에 관한 수치해석연구 (A Numerical Study for the Performance of Natural Smoke-venting of a Vertical Vent)

  • 전흥균;최영상;추홍록
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.1-10
    • /
    • 2008
  • 본 연구에서는 미국 NFPA 204 기준에 의해 설계된 수직 배연구에 대하여 배연구의 위치, 외기 온도, 풍속 및 화재크기가 자연배연 성능에 미치는 영향과 화재특성을 CFAST 프로그램을 사용하여 수치 해석적으로 조사하였다. 배연구는 외벽의 최고 상부에 위치한 경우와 외기온도가 낮은 경우 및 풍속이 작은 경우 배연성능기준을 만족하였다. 또 화재크기가 클수록 배출량은 증가하나 연기층 높이는 낮아져 배연성능기준을 만족하지 못하였다. 직접 외기와 통하는 수직 자연배연구의 설계시 해당지역의 최고 온도와 최대 풍속을 고려하고, 설계화재를 정확히 결정하여 배연성능기준이 만족되도록 주의가 요망된다.