• 제목/요약/키워드: vertical thermal distribution

검색결과 111건 처리시간 0.029초

Improvement of Condensation Performance in Corridor Type Apartment Door

  • Lee, Sungbok;Hwang, Hajin
    • Architectural research
    • /
    • 제10권1호
    • /
    • pp.33-39
    • /
    • 2008
  • Condensation has mainly occurred in corridor type apartment door which is exposed to the outside air and is made of steel, which has high thermal conductivity. As a result, the total costs of repair have increased with the number of disputes with residents. In this study, therefore, we investigate materials and construction methods used in apartment door, perform a computer simulation to find out possible improvements, and then suggest the dew point to prevent the occurrence of condensation throughout simulation. The results indicate that the temperature that condensation does not occur is $15.4^{\circ}C$, and the optimum method of achieving this dew point is shown to be a door frame system including a large vertical slot to decrease the area of thermal conduction between the outer and inner portions of the door frame. Mock-up tests show that the surface temperature of the door frame was higher than the dew point, and the system can withstand severe cold conditions of $-20^{\circ}C$. In application test, the surface temperature of door frame with vertical slots is $5.9^{\circ}C$in average, which is higher than the existing door frame. Furthermore, in the temperature distribution of the surrounding door measured with infrared ray camera, the existing door shows the high temperature distribution indicating lack of insulation, but the improved door shows the low temperature distribution indicating higher insulation.

유한요소법에 의한 열전달 연구 -4각열원 주위- (A study of Heat Transfer by the Finite Element Method - Around Square Heat Source -)

  • 장재은
    • 한국안전학회지
    • /
    • 제13권1호
    • /
    • pp.26-33
    • /
    • 1998
  • This paper subdivided the interior solid into triangular shape of equal size to calculate the temperature distribution around the square heat source of it, and compared calculated values with measured ones. The result obtained are as follows. 1) It was found that we can calculate the temperature distribution around the square heat source of interior solid by the variational method of the finite element method as the calculated values were almost accord with the measured ones. 2) The temperature distributed were higher when the distances between heat source were farther and lower when those nearer. 3) Vertical surface temperature distribution is remarkably efficient by thermal conductivities.

  • PDF

수치해석을 통한 수직 밀폐형 지중열 교환기의 열전달 거동 연구 (Thermal Behavior of Vertical Ground Heat Exchanger by Numerical Simulation)

  • 길후정;이철호;김주영;최항석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1638-1646
    • /
    • 2008
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 2-D finite element analysis, ANSYS, was employed to evaluate the temperature distribution on the borehole cross section involving HDPE pipe/grout/soil formation to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system which is equipped with a thermally insulating latice in order to reduce thermal interference between the inflow and outflow pipes. In addition, a 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of grout's thermal properties, rate of circulation pump, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

CFD를 활용한 바닥공조시스템 디퓨저의 성층화 모델 예측 (Prediction of Stratification Model for Diffusers in Underfloor Air Distribution System using the CFD)

  • 손정은;유병호;방승기;이광호
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.105-110
    • /
    • 2017
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings. UFAD systems use the underfloor plenum beneath a raised access floor to provide conditioned air through floor diffusers that create a vertical thermal stratification during cooling operations. Thermal stratification has significant effects on energy, indoor air quality, and thermal comfort performance. The purpose of this study was to characterize the influence of a linear bar grille diffuser on thermal stratification in both interior and perimeter zones by developing Gamma-Phi based prediction models. Forty-eight simulations were carried out using a Computational Fluid Dynamics (CFD) technique. The number of diffusers, the air flow supply, internal heat gains, and solar radiations varied among the different cases. Models to predict temperature stratification for the tested linear bar grille diffuser have been developed, which can be directly implemented into dynamic whole-building simulation software such as EnergyPlus.

급기구 형상에 따른 겨울철 실내 온열환경의 비교 (Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations)

  • 한화택;정영균
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

공작기계 스핀들 부위의 열분포 분석 및 오차 보정 (Analysis of Thermal Distribution and Compensation of Error for Spindle of Machining Center)

  • 고한서;박광희;서형렬;하종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1352-1357
    • /
    • 2004
  • Thermal error compensation has been developed for CNC (Computer Numerical Control) machining center with moving heat sources. The thermal error in CNC machining center has an effect on machining accuracy more than the geometric error does. Thus, temperature distributions of a spindle unit have been analyzed numerically by a Finite Differential Method and experimentally by an infrared (IR) camera in this study. A multiple variable method has been derived to estimate the thermal deformation of the machine origin stably and effectively after measuring deformation and temperature data. The experimental results for a vertical machining center have shown that the thermal errors of the machine origins were reduced more than 30% by the developed method.

  • PDF

대공간내 인체발열 미고려시의 하계 온열환경 조사 (A Study on the Indoor Thermal Environment of the Large Enclosure Without Cooling Loads from Occupancy in Summer)

  • 정성진;최동호;양정훈;석호태
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.3-8
    • /
    • 2008
  • 본 연구에서는 기존 대공간의 냉방시에 발생될 수 있는 분포상의 문제점을 실측실험을 통해 확인하여, 궁극적으로는 대공간의 열환경 개선과 효율적인 냉방설계를 위한 기초데이터를 제시하고자 하였다. 본 연구에서는 인체부하 미고려시의 하계 대공간의 실내온열환경 실측실험을 실시하여 공간내 수평 및 상하온도분포특성, 취출기류의 거동특성, 실내쾌적온열환경 특성, 환기량 평가 등 대공간의 하계 실내온열환경을 포괄적으로 검토하였다.

  • PDF

대규모 실내경기장의 하계 온열환경 특성 실측조사 - 인체부하 미고려 조건 - (A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Summer - Without Cooling Loads from Occupancy -)

  • 정성진;최동호;양정훈;석호태
    • 한국공간구조학회논문집
    • /
    • 제7권6호
    • /
    • pp.91-101
    • /
    • 2007
  • 본 연구에서는 기존 대규모 실내경기장의 냉방시에 발생될 수 있는 분포상의 문제점을 실측실험을 통해 확인함으로서 궁극적으로는 대공간의 열환경 개선과 효율적인 냉방설계를 위한 데이터를 제시하고자 하였다. 본 연구에서는 인체부하 미고려시의 하절기 대공간의 실내온열환경 실측실험을 비냉방시와 냉방시로 구분하여 실시하였으며 공간내 수평 및 상하온도분포특성, 취출기류의 거동특성, 실내쾌적온열환경 특성, 환기량 평가 등 대공간의 실내온열환경을 포괄적으로 검토하였다.

  • PDF

지중 유효 열전도도의 지역별 분포 (A Study on Regional Distribution of the Ground Effective Thermal Conductivity)

  • 공형진;권순기;지승규
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.43-47
    • /
    • 2016
  • 지열 히트펌프 시스템은 환경 친화적이고 에너지 절감 시스템으로 알려져 있다. 특히 지중 열교환기는 초기투자비와 시스템 성능을 결정하는 매우 중요한 요소다. 수직형 지열 시스템 설계를 위해서는 현장 열응답 테스트를 통해 지중 유효 열저항을 고려해야 한다. 본 연구에서는 지열이용검토서를 통해 접수된 전국의 지중 열전도도를 지역별로 분석하였다. 전국 평균 지중 열전도도는 2.56 W/mK로 분석되었다. 지중 열전도도가 가장 높은 지역은 서울로 평균 2.68 W/mK이고, 가장 낮은 지역은 부산으로 2.28 W/mK다. 또한 해안을 접하고 있는 지역의 열전도도는 전국 평균에 비해 약 30% 낮다.

인체부하를 고려한 대규모 실내경기장의 동계 온열환경 특성 실측조사 (Measurement Examination of Indoor Thermal Environment Characteristic in accordance with Heat Loads from Occupant for Large Enclosure in Winter)

  • 석호태;채문병;최동호
    • 한국공간구조학회논문집
    • /
    • 제7권3호
    • /
    • pp.97-107
    • /
    • 2007
  • 본 연구에서는 대공간의 동계시 인체발열에 따른 실내온열환경의 변화를 실측하고 난방조건 및 외부환경과 관련하여 대공간에서 형성되는 실내온열환경의 특성을 파악하는 것을 목적으로 한다. 본 논문에서는 대공간의 실내수직 및 수평온도분포, 객석의 온도분포, 실내표면온도분포, 객석의 풍속분포, 실내온열쾌적성 등의 실내온열환경을 검토한다.

  • PDF