• Title/Summary/Keyword: vertical illuminance

Search Result 25, Processing Time 0.025 seconds

A Study on the Illuminance Distribution on the Pedestrian Road at the Central Business District for Classifying lighting Environments (조명환경구역 구분을 위한 도심상업지역 보행자 도로의 조도분포 실태조사)

  • Lee, Jong-Sik;Park, Jin-Chul;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.1-13
    • /
    • 2009
  • The purpose of this study is to investigate the applicability of the CIE standard on lighting environments to Korea. In the field study, horizontal and the vertical illuminance was measured at the pedestrian road in the central business district of a city, and the questionnaires were conducted to get information regarding pedestrian's satisfaction with lighting environment. Four areas were selected for this survey. That areas have different type of pedestrian roads concerning the lighting conditions and the number of walkers. From the results of the measurements, It is known that the illuminance of pedestrian roads is different according to the lighting conditions and the number of poot passengers. Also the results of questionnaires show that the illuminance of the pedestrian roads affect to the pedestrian's satisfaction. Lastly, the CIE standard on lighting environments is applicable to the central business district of the cities in Korea.

A Study on the Luminous Environments of Architectural Building for Improvement of Night-Scape in Coastal Resort - Focused on the Gyengpo Park - (해안 휴양지의 야간경관 개선을 위한 건축물의 조명환경 연구 - 경포도립공원을 중심으로 -)

  • Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.3
    • /
    • pp.27-34
    • /
    • 2008
  • Recently, the outdoor lighting of architectural Facade has increased for the improvement of night-scape in urban and coastal resort. The purpose of this research is to analyze lighting characteristics; Luminance, Illuminance, Color Temperature, Chromaticity in Gyengpo Park of Eastern famous coastal resort. The result of this paper is as follows: 1) The Luminance ratio was measured that compare to the 1:10 criterion(IESNA) was in excess to the most building except "K". Because of these condition, Luminance environments was injurious to visual health the overuse of the outdoor lighting or glare to the eyes. 2) The level of vertical Illuminance value was insufficient 33.3% among the cases of survey with 4Lux standard of CIE. 3) The kinds of outdoor lighting of BLDG were increased lighting emitting diode(LED), metal halide(MH) instead of reduction trend of neon, fluorescent light, halogen. As the crisis of Energy resources we will be investigate adapt method of outdoor lighting, which design is based on economical efficiency by the use of optimum lighting.

  • PDF

The Design Of A Reflector For Blackboard Lighting (칠판등용 반사판의 광학적 형상 개발)

  • Park, Hye-Jin;Kim, Dong-Jo;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.13-19
    • /
    • 2003
  • Giving teachers and students the clean visual environment, the classroom lighting is an important part that prevents the decrease of the visual acuity and improves the studying environment. In order to improve the classroom lighting, a proper blackboard luminaire is to be developed. This paper explains how to design the optical form of the high efficient reflector which offers the uniform illuminance at the vertical surface of the blackboard and, after all, the problem of a large source in reflector design process is explained.

In Lighting Design, Space Accessibility of Vertical Elements of the Light (조명디자인에서 빛의 수직적 요소의 공간접근성)

  • Cha, In-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.4
    • /
    • pp.43-50
    • /
    • 2015
  • In lighting design and lighting in the light of how the physical space rather than the amount of light metering is implemented in the same space as horizontal illuminance and luminance study of the spatial analysis as a basis for improving the quality of scientific and cognitive aspects analyzed the vertical component of the light. Vertical component of the light and the ability to interpret the information space can be secured more easily sense the brightness of a small area compared to the horizontal components of electrical energy, due to the contrast between the dark and the surrounding induce customers to public facilities or commercial space The pedestrian aids to facilitate the determination of the copper. In addition, to secure the brightness of the overall sense of space allows to have a sense of comfort to lower the tension of the space. The vertical component of light also has a deep relationship to improving the quality of light in electrical energy savings increase the accessibility of space, space, nightscape in the humanities also contribute to environmental and looking for one trillion people in the city in terms of cultural development and identity There.

Light Intensity and Spectral Characteristics of Fluorescent Lamps as Artificial Light Source for Close illumination in Transplant Production Factory (식물묘공장의 근접조명용 인공광원으로서 형광등의 광강도 및 분광 특성)

  • 김용현;이종호
    • Journal of Biosystems Engineering
    • /
    • v.23 no.6
    • /
    • pp.591-598
    • /
    • 1998
  • Light intensity and spectral characteristics of different types of fluorescent lamps were tested to investigate their possibility as the artificial lighting sources for the close illumination applied in the transplant production factory. Photosynthetic photon flux densitiy(PPF), illuminance and irradiance for all lamps decreased logarithmically with an increase of the vertical distance from the lighting source. The fluorescent lamp specially designed plant growth (PG lamp) showed a maximum spectral irradiance at the wavelength of 660nm. However, it showed lower irradiance than that of a standard fluorescent lamp at the range of wavelength between 500 and 600nm. On the other hand, PG lamp showed higher PPF and lower illuminance than those of the standard fluorescent lamp. The maximum peak of spectral characteristics for both of the single and twin three-bind fluorescent lamps was shorn at the wavelength of 545m and the next peaks were shown at the wavelength of 610nm and 435nm, respectively. Since the red fluorescent lamp has a narrower peak at the wavelength of 660nm, it may be useful for the supplementary red lighting. For three of standard, single three-band and twin three-band fluorescent lamps, the values of conversion factor for converting illuminance to PPF fell within the narrow range from 76 to 791x/$\mu$molㆍm$^{-2}$ ㆍs$^{-l}$ . However, for PG lamp, it was 29.71x/$\mu$molㆍm$^{-2}$ ㆍs$^{-1}$. Also, the values of conversion factor for converting PPF to irradiance of fluorescent lamp used in this study ranged between 4.85 and 5.34$\mu$molㆍm$^{-2}$ ㆍs$^{-1}$/Wㆍm$^{-2}$ .

  • PDF

Optical Design of LED module for Street Light Applications

  • Aung, Aye Thida;Yang, Jong-Kyung;Lee, Seung-Min;Lee, Jong-Chan;Park, Dae-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.11
    • /
    • pp.1-8
    • /
    • 2008
  • In this paper, the optical properties of the 54[W] LED module have confirmed by changing the angles of LED modules for street light applications. The angle of LED module changed from the $0[^{\circ}]$ to $60[^{\circ}]$ varying by $20[^{\circ}]$ as horizontal direction ${\ominus}_1$. Morever, the angle of LED module changed from the $0[^{\circ}]$ to $15[^{\circ}]$ varying by $5[^{\circ}]$ as vertical direction ${\ominus}_2$. As a result of simulation, the average illumination was about 17[lux] and the overall illuminance uniformity was 0.29 for a 10.39[m] long and 6[m] wide illuminance area at height of 6[m], which is acceptable for street lighting illumination in the Illuminating Engineering Society(IES) standard.

Subjective Evaluation of Glare for Blinking and Colors of Vertical LED Lighting (수직형 LED 조명의 색상 및 점멸에 따른 눈부심 주관평가)

  • Jung, Hyun-Ji;Kim, In-Tae;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.22-30
    • /
    • 2015
  • Currently, in South Korea, 'Light Pollution Prevention Act by Artificial Lighting' has been enforced. For advertising lighting, it is limited based on only the light-emitting luminance. Luminance is a concept related to the glare. Not only the luminance of the light source, but also glare is affected depending on some situations like blinking, luminance contrast, background illuminance. This study conducted glare subjective evaluation with brightness, color, and blinking by looking at the LED lighting box. The results showed that the glare indexes were higher about 2 times in a decrease of background illuminance from 100lx to 0lx. The glare index of R, G, B light was higher than that of white light. The average glare index of the blue light was higher about 8 times compared to 2,700K. And the blink rate had little effect on the glare, but it affected the irritation. Therefore, the glare effect of light color and blinking needs to be considered for the standard of luminous environment.

Empirical Evaluation of Optimal User-Centered LED Lighting Environments in Residential Bathrooms

  • Lee, Jeongmin;Choi, Kyungah;Suk, Hyeon-Jeong
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.305-310
    • /
    • 2013
  • This user-centered research aims to empirically evaluate color temperature (K) and illuminance (lx) of residential bathroom lightings to determine the most optimal lighting conditions for productive task performance as well as for satisfying users' emotional needs. Using 3 LED lighting fixtures, 4 types of lighting contexts were investigated; main lighting, task lighting, shower lighting, and bath lighting. Two lightings were installed parallel to the vertical edges of the main bathroom mirror to be used as main and task lighting, while another fixture was installed above the bathtub to be used for shower and bathing. For each lighting context, subjects (N=54) were instructed to perform a few tasks during which time the users were exposed to different lighting conditions with color temperature ranging from 2700 K ~ 6500 K and illuminance ranging from 100 lx ~ 700 lx. Upon completing the given tasks, subjects were asked to evaluate the lighting conditions and their applicability for performing the given tasks. Based on the user evaluations, the most optimal lighting conditions for the different lighting scenarios are as follow: 1) 3500 K ~ 4300 K and 150 lx for main lighting, 2) 3500 K ~ 4300 K and 500 lx ~ 700 lx for task lighting, and 3) 2700 K ~ 3500 K and 100 lx ~ 150 lx for shower/bath lighting. These results can be used to adjust the lighting standards suggested by KS, as well as be utilized by both engineers and designers in designing new types of user-centered bathroom lightings.

  • PDF

Light Pollution Survey of Outdoor Lighting in Shopping Complex (쇼핑용 복합빌딩의 옥외조명으로 인한 광공해발생 실태조사)

  • Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.16-26
    • /
    • 2004
  • As the importance of outdoor lighting become more widely recognized, outdoor lighting has been installed in many buildings, plazas, landscape, and historical monuments in Korea, Outdoor lighting on showing complex, in particular, express its values as local landmarks. However, the excessive outdoor lighting in the large-scale shopping complex tends to cause light pollution. Many advanced countries are trying to create a comfortable lighting environment by the guidlines and regulations on outdoor lighting to prevent light pollution. For this research backgrounds, the light pollution of three showing complexes in Seoul have been investigated. For the purpose, luminance of building facade, horizontal illuminance, and vertical illuminance were measured with proper measurement instruments and compared the results with the CIE recommendations. The results of the study are as follows. As no cut-off luminaries are currently installed on pedestrian walks, some glare were occured partially. It also shows that the luminance of building facades are high to improve the degree of public awareness of buildings and advertisements. In other words, the luminance of the building facade, when compared with that of the CIE recommendations, is twice as high and the vatical illuminance of pedestrian walks is far higher than that of the CIE recommendations, which proves the existence of light pollution. As Korea has not yet provided proper regulations or guidelines for the control of light pollution, it is necessary to make appropriate codes for it.

Effects of Security Lighting Lamps on Discomfort Glare to Indoor Occupants

  • Lee, Yoon Jeong;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: Although security lights are used to secure pedestrian visibility and safety at nighttime, they can generate light trespass in the neighboring residential space. To prevent this, standards for acceptance limits on vertical illuminance and light pollution by the windows of residential buildings are presented. Method: This study thus representatively selected three types of lamps and, through an evaluation and analysis of the physical and subjective discomfort glare per lamp, proposed a discomfort glare index for each lamp. The evaluation and analysis according to the lamps were conducted through experiments. The variables were the security lights' lamps (NH 100W, MH 70W, LED 50W), installation angles ($0^{\circ}$, $20^{\circ}$), and installation distances (3m, 5m, 7m, 9m). Result: According to the results of the discomfort glare evaluation depending on the angles and distances of the security lights, the following minimum standards are proposed: for NH 100W, a discomfort glare index of 30 and an installation distance of 4m; for MH 70W, a discomfort glare index of 32 and an installation distance of 4m; and, for LED 50W, a discomfort glare index of 31 and an installation distance of 6m, respectively. In addition, this paper recommends the use of MH 70W, when the road width is 4m-6m, and LED 50W, when the road width is over 6m, respectively.