• 제목/요약/키워드: vertical illuminance

검색결과 25건 처리시간 0.026초

VBA(Visual Basic for Applications)를 활용한 실외 수직면 조도 간이계산법에 관한 연구 (A Study of Simplified Calculation Methods for Outside Vertical Illuminance using VBA)

  • 윤수인;김강수
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.65-72
    • /
    • 2018
  • The purpose of this study is to predict vertical illuminance accurately at the design stage of a building without the help of simulation tools. Comparing two well-known vertical illuminance prediction algorithms with measured values, it is verified that the Igawa model is more consistent with the measured values than the Perez model. Using the DIVA program, we simulated the vertical illuminance at 30-degree intervals from south to north, compared with the vertical illuminance calculated with the Igawa model. The result of calculation values were verified from 120 degrees east to 120 degrees west. The vertical illuminance values with each of three shade devices were calculated using the Igawa model, and compared with the vertical illuminance simulated by DIVA program. As a result, all the errors when installing horizontal / vertical / grid shade divices were included in the error standard specified by ASHRAE.

일사의 발광효율을 이용한 수직면 주광조도 예측에 관한 연구 (Predicting Daylight Illuminances on Vertical Surfaces Using Luminous Efficacy of SolarIr radiance)

  • 윤갑천;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.19-27
    • /
    • 2014
  • Exterior vertical illuminance is an important factor for lighting control. But, there are not many researches about the exterior illuminance on a vertical surface. In this study, we predicted the exterior illuminance on a vertical surface using vertical luminous efficacy. First, we calculated the vertical luminous efficacy according to the sky clearness category. And we performed the statistical analysis of the measured and the calculated illuminance with luminous efficacy. The MBE and RMSE of the predicted exterior illuminance were-1.2% and 15.5%, respectively. Second, the annual illuminance on a vertical surface calculated with the luminous efficacy and the short-term measured solar irradiance was suggested in this study.

An Experimental Study to Determine Proper Lighting Conditions in Powder Rooms

  • Kim, Hyun-Ji;Lim, Jang-Hyeon;Kim, Hoon
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.54-62
    • /
    • 2013
  • In this study, a mock powder room was installed with variable LED lighting environments in order to conduct the experiments. The experimental conditions include luminaire type, illuminance ratio, vertical illuminance and color temperatures. The evaluation methods used were the Semantic Differential Method and a subjective evaluation on activities through observation. The SD evaluation result factor analysis categorizes ideas into three factors: brightness, emotion, and glare. The vertical bracket or the combined luminaire (luminous panel+ Vertical bracket) has better brightness than luminous panel. A vertical illuminance of 500lx is not significantly difference as compared to 600lx, allowing 500lx to be considered standard. The emotional atmosphere is evaluated as being better at lower color temperature. The luminous panel is the best for reducing glare while the vertical bracket is the worst. The best conditions differ according to the illuminance ratio of the luminous panel and vertical bracket. In the subjective evaluation (satisfaction with lighting environment, suitability to activity) the combined luminaire and 4000K received the best evaluation.

소규모 사무실에 적용된 조광제어 시스템의 최적제어를 위한 주광변화 분석 (Analyses on Daylight Variations for Optimum Controls of Daylight Dimming Systems in a Small Office)

  • 윤연주;백용규;김수영
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.433-442
    • /
    • 2012
  • The influence of outdoor sky conditions on photosensor signals were examined to determine an appropriate index that is effectively used for optimum illuminance fluctuation when a daylight dimming system is used for a small office. Field measurements were conducted under various sky conditions. Results indicate that the outdoor global and vertical illuminance fluctuated within narrow ranges under clear and overcast sky conditions. The fluctuation of sky ratio under partly-cloudy sky caused wide ranges of illumnance fluctuation. A partially-shielded photosensor at backwall produced 56% of light output from fixtures controlled by a photosensor at ceiling. This implies that the photosensor at backwall does not always guarantee target illuminance due to the less output. The fluctuation of light output from fixtures were insignificant under clear and overcast sky. The fluctuation range of photosensor illuminance under partly-cloudy sky caused wide fluctuation ranges of light output. Regression result implies that the outdoor vertical illuminance was recommended for an effective index that is used for control of light output.

광속법을 이용한 등배치 설계에 관한 연구 (A Study On the Design of Balaced Illuminance Using Lumen Flux Method)

  • 최홍규;최병숙;정성윤;김진성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.175-180
    • /
    • 1999
  • This paper presents the effective design of the change of average illuminance and the arrangement of lamps by changing the form of working area and adjusting the distance between the wall and light. This study is intended to simplify the complex calculation of illuminance through the development of application program. It's plan to study application programs that can attain the value of advanced uniformly-distributed illuminance and average illuminance by changing the distance between the horizontal/vertical wall and lamp and between the horizontal/vertical lamp and lamp.

  • PDF

소규모 사무공간의 조명에너지 절감율 평가에 관한 연구 (Evaluation of Lighting Energy Saving Rate in a Small Office Space)

  • 김한용;윤경;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.50-58
    • /
    • 2012
  • The objective of this study is to evaluate the lighting dimming rates with various parameters of the building skin in a small office. We compared to simulated workplane illuminance and measured workplane illuminance for the base model. After that, the five veriables(the presence of vertical wall in double skin facade, the presence of windowsill, window to wall ratio(WWR), window visible transmittance, the width of double skin facade) were applied to base model, and we analyzed the simulated lighting energy saving rates. The results are listed as below. The simulated workplane illuminance results are similar to the measurement. Simulated illuminance was smaller than measured illuminance by 16.5%(60 lx). In accordance with applicable building skin parameters, lighting energy saving rate results are summarized as follows. Lighting energy saving rate of case1(windowsill height 0.7m) is higher than that of base case(windowsill and vertical wall) by 7.3% and the lighting energy saving rate of case2(no vertical wall) is higher than that of base case by 7.6% and the lighting energy saving rate of case3(no windowsill and vertical wall) is higher than that of base case by 12.4%. The lighting energy saving rate is increased by 2.3%, when window visible transmittance is increased from 70% to 86%. The lighting energy saving rate is increased by 4.6%, when we changed the WWR 70% to 90%. lighting energy savings rate is increased by 6.5%, when the width of double skin facade is reduced from 1m to 0.3m.

축구 경기장의 조명타워 위치에 따른 조도분포 해석 (Illuminance Distribution Analysis by Lighting Tower Position of o Soccer Stadium)

  • 김길영;최홍규;최병숙
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2004
  • 오늘날 축구는 세계적인 주목을 받는 스포츠가 되었다. 특히, 2002 KOREA-JAPAN 월드컵은 한국에 대한 깊은 인상을 심어 주었다. 축구경기장의 조명시스템 설계에 있어서 가장 주요한 기술적 목적은 경기장의 어디에서나 최적의 분포를 나타내도록 하는 것이다. 이렇듯, FIFA는 경기장의 어디에서나 선수, 청중, 방송관계자등에게 일정한 수준의 조도를 제공할 수 있도록 규정하고 있다. 본 논문에서는 경기장의 조명타워의 위치선정에 따른 최적의 수평면 조도와 수직면 조도를 찾기 위한 알고리즘을 제시하였다. 본 논문에서는 Philip's Calculux 프로그램을 이용하여 조명타워의 위치에 따라 수평면 조도, 수직면 조도, 균제도, 글레어 등을 계산하였다.

조광제어 시스템 적용시 실내조도의 변동예측을 위한 포토센서의 주광조도 분석 (Analyses on Photosensor Illuminance for Prediction of Fluctuating Illuminance by Daylight Dimming Control Systems)

  • 김수영
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.788-797
    • /
    • 2010
  • This study examines the influence of fluctuating daylight illuminance on daylight dimming control systems. Field measurements were performed for a full-scale mocked-up model under various daylight conditions in winter. Fluctuating ranges for a partially-shielded photosensor were great when the variation of sky ratio was great. When solar altitude was lower the illuminance and fluctuating range of illuminance were great due to the influence of direct components of daylight and the interrefelction between surfaces in rear area of space. It implies that daylight dimming system would not function effectively, unless the desktop illuminance by daylight is enough. Fluctuation ranges of photosensor illuminance were lower than 50 lx under clear sky conditions, but they were greater than 100 lx under partly-cloudy sky conditions. It means that the fluctuation range of electric light output of lighting fixture would greater under the partly-cloudy conditions and cause potential visual annoyance to occupants. Outdoor vertical illuminance reaching the windows would be an effective factor that can be used to predict the fluctuation of photosensor signals for effective controls of daylight dimming system.

미술관의 조명환경 변화에 따른 시각적 반응 및 피로감각 변화분석 (Influence of Luminous Environments on Visual Responses and Fatigue Sensation in Art Galleries)

  • 박윤혜;김수영
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.61-72
    • /
    • 2011
  • The influences of luminous environment on visual responses and fatigue sensation in art galleries were examined in this study. Field measurements and survey were performed in three galleries under various illuminance and luminous conditions. Result implies that vertical illuminance on art paintings needed to be somewhere between 200 lx and 300 lx to avoid visual discomfort. The vertical illuminance difference between consecutive paintings should not exceed 100 lx to keep visually comfortable environment. Visual comfort sensations were related to glare, visual stimulus, reflection from paintings, illuminance variation, and the sensation that subjects can clearly see the paintings. The sensation of fatigue was significantly influenced by the changes of luminous element that caused visual stimulus and discomfort. The sensation of eye fatigue among physical fatigue was primarily influenced by the glare, visual stimulus and comfort. The psychological fatigue was also influenced by eye fatigue, visual comfort, brightness and satisfaction with color of light.

CIE 권장가이드를 이용한 자연채광 기후요소 측정시스템의 유효성 검증 (Validation of a Daylight Measurement System Using the CIE Guide of Recommended Practice of Daylight Measurement)

  • 공효주;이종수;김곤;윤근영;김정태
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.41-46
    • /
    • 2010
  • This study is to validate the K University daylight measurement system according to the CIE guide of recommended practice of daylight measurement. In this study global irradiance, illuminance, direct normal illuminance, diffuse irradiance, illuminance and vertical illuminances(North, West, South, East) were measured and compared in accordance with the CIE quality control test. Field monitoring was conducted from 1st August to 15th August 2010. Results for the CIE tests 1 to 4 showed an accuracy of 100%. This indicates that the K University daylight measurement system is reliable and the measurement data would be useful for further daylight researches.