• 제목/요약/키워드: vertical fin

검색결과 77건 처리시간 0.023초

단일수직(單一垂直)한 축방향(軸方向)의 핀을 가진 수평전도관(水平傳導管)으로 부터의 자연대류(自然對流) (Natural Convection from a Horisontal Conducting Tube with One Vertical Axial Fin.)

  • 정한식;권순석
    • 태양에너지
    • /
    • 제6권1호
    • /
    • pp.60-69
    • /
    • 1986
  • Two-dimensional finite difference numerical analysis is used to study conjugate natural convection heat transfer from a horizontal conducting tube with one vertical axial fin. By increasing dimensionless fin length ($L_F$), the mean total Nusselt number of the upward fin is slightly less than that of the downward fin at $L_F\;{\le}\;0.18$ and is higher than that of the downward fin at $L_F\;>\;0.18$. However comparing the upward fin and the downward fin with the no fin, the mean total Nusselt numbers of downward fin and upward fin at $L_F=0.30$ are increased approximately 4.01% and 5.51%, respectively. As Rayleigh number, Prandtl number and Biot number increase, the mean total and the mean tube Nusselt numbers are increased, but as wall thickness increases, the mean total and the mean tube Nusselt numbers are decreased. As the fin conduction parameter increases, the mean total Nusselt number is slightly increased because of increasing the mean fin Nusselt number.

  • PDF

동종 접합 InGaAs 수직형 Fin TFET의 온도 의존 DC 특성에 대한 연구 (Temperature-dependent DC Characteristics of Homojunction InGaAs vertical Fin TFETs)

  • 백지민;김대현
    • 센서학회지
    • /
    • 제29권4호
    • /
    • pp.275-278
    • /
    • 2020
  • In this study, we evaluated the temperature-dependent characteristics of homojunction InGaAs vertical Fin-shaped Tunnel Field-Effect Transistors (Fin TFETs), which were fabricated using a novel nano-fin patterning technique in which the Au electroplating and the high-temperature InGaAs dry-etching processes were combined. The fabricated homojunction InGaAs vertical Fin TFETs, with a fin width and gate length of 60 nm and 100 nm, respectively, exhibited excellent device characteristics, such as a minimum subthreshold swing of 80 mV/decade for drain voltage (VDS) = 0.3 V at 300 K. We also analyzed the temperature-dependent characteristics of the fabricated TFETs and confirmed that the on-state characteristics were insensitive to temperature variations. From 77 K to 300 K, the subthreshold swing at gate voltage (VGS) = threshold voltage (VT), and it was constant at 115 mV/decade, thereby indicating that the conduction mechanism through band-to-band tunneling influenced the on-state characteristics of the devices.

수직 평판휜으로부터의 복합자연대류에 미치는 복사효과 (Effects of Radiation on Conjugate Natural Convection from a Vertical Plate Fin)

  • 김경훈;김세웅
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.382-390
    • /
    • 1992
  • The problem of natural convection from a vertical fin is solved by coupling the thermal diffusion equation in the fin to the constitutive equations of the ambient medium involving the radiation of the medium. The analysis is accomplished by employing an integral method. The governing equations for the problem are solved by shooting method based on the Runge-Kutta Scheme at Pr= 0.7. For the range of values of the fin parameter and the radiation-conduction parameter in the analysis, the numerical results show that the radiation effects play an important role in the heat transfer and enhance the heat transfer.

수직평판(垂直平板)에 부착(附着)된 수평(水平)핀에서의 자연대류(自然對流) (Natural Convection from a Vertical Flat Plate with Horizontal Rectangular Fins)

  • 김선정;이정철;서리수;권순석
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.448-455
    • /
    • 1988
  • A study has been conducted experimentally on natural convection heat transfer characteristics of a vertical flat plate with horizontal rectangular fins in air. The effects of fin heights and Rayleigh numbers are mainly investigated. The experimental results are as follows; 1. The mean fin, plate and total Nusselt numbers decrease as dimensionless fin heights H/S increase at $0.50{\leq}H/S{\leq}2.00$. 2. The mean fin surface Nusselt number in case of H/S = 0.50 and $Ra_c=4.33{\times}10^3$ shows its maximum at $X_1$, surface where there is no interference with other fins. 3. Owing to the interference of fins the mean plate Nusselt numbers at H/S=0.50 and 2.00 for $Ra_S=6.57{\times}10^3$ are 35% and 80% respectively less than the mean fin Nusselt numbers. 4. The mean fin, plate and total Nusselt numbers of horizontal rectangular fins show higher values at short fins, but lower values at long fins than those of upward vertical fins.

  • PDF

2개의 수직휜이 부착된 내관으로부터 환상공간내의 자연대류 열전달 (Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins)

  • 정태현;정한식;권순석
    • 대한기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.654-660
    • /
    • 1991
  • Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins has been studied for the effects of dimensionless fin length and Rayleigh number. The maximum local Nusselt number of inner tube was obtained at .theta. = 145.deg. and that of outer cylinder at .theta. = 0.deg. for the case of $l_{F}$=0.3 Local Nusselt number distributions for the lower fins show higher values than that of the upper fins. The mean Nusselt number of inner tube was increased with the values of dimensionless fin length. The mean Nusselt number can be represented in an exponential function of Grashof number at various fin lengths. As compared with experimental and numerical results, isotherms and local Nusselt number show good agreement.t.

외경 5mm 수직 평활관 및 마이크로핀관 내의 이산화탄소/프로판 혼합냉매의 증발열전달 특성에 관한 실험적 연구 (An Experimental Study on the Evaporative Heat Transfer Characteristics of $CO_2$/Propane Mixtures Flowing Upward in Vertical Smooth and Micro-fin Tubes with an Outer Diameter of 5 mm)

  • 조진민;김민수
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.243-251
    • /
    • 2009
  • Refrigerant mixtures provide an opportunity to adjust their properties to fit design criteria and a possibility to create new blends that can improve heat transfer characteristics. Therefore, mixture of $CO_2$ and propane is chosen which may be a promising refrigerant and has good environmental compatibility. This paper presents measured heat transfer coefficient data during evaporation process of $CO_2$/propane mixtures flowing upward in vertical smooth and. micro-fin tubes. Smooth and micro-fin tubes with outer diameters of 5 mm and length of 1.44in were selected as test tubes. The tests were conducted at mass fluxes of 212 to $656kg/m^{2}s$, inlet temperatures of -10 to $30^{\circ}C$, heat fluxes of 15 to $60\;kW/m^2$ and for several compositions (75/25, 50/50, 25/75 wt%). Among $CO_2$/propane refrigerant mixtures, the heat transfer characteristics are much better than that of any compositions when the composition is 75/25 (wt%).

2개(個)의 수직(垂直) 평판(平板)핀을 가진 전도관(傳導管)으로 부터의 자연대류(自然對流) 열전달(熱傳達) (Natural Convection Heat Transfer from a Conducting Tube with Two Vertical Axial Fins)

  • 정한식;이철재;권순석
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.222-230
    • /
    • 1991
  • Conjugate heat transfer by steady laminar natural convection from a conducting tube with two vertical axial fins has been studied by a finite difference numerical procedure under basic conditions; $Ra=10_6$, Pr = 5 and $L_F=0.15$. The maximum local tube Nusselt number appears at ${\theta}=140^{\circ}$ for $L_F=0.06$, at ${\theta}=130^{\circ}$ for $L_F=0.30$ and at ${\theta}=120^{\circ}$ for $L_F=0.30$, $L_F=0.06$, respectively. The maximum mean Nusselt number shows at $L_F=0.18$ for the downward fin and at $L_F=0.12$ for the upward fin. Therefore the optimized fin length is $L_F{\approx}0.15$ under these conditions. At $L_F=0.15$, the mean Nusselt number by increasing Rayleigh number is remarkably increased for downward fin and then is slowly increased except for downward fin, it by increasing Prandtl number is apparently increased at $Pr{\leq}2$, and slightly increased at Pr>2.

  • PDF

수직 휜을 갖는 아래 평판 위에서 등속 운동을 하는 위 평판에 의한 유동 (Flow Induced by the Uniform Motion of Top Plate over the Bottom Plate with Vertical Fin)

  • 박준상
    • 대한기계학회논문집B
    • /
    • 제25권7호
    • /
    • pp.877-884
    • /
    • 2001
  • A theoretical analysis is conducted on the Stokes flow in a narrow channel. A vertical fin is mounted on the bottom plate and the flow is induced by uniformly sliding top plate. The governing harmonic equation was solved in the transformed ζ-plane, which is obtained by applying conformal mappings to the physical plane. By using well-known transformation technique, closed-form expressions for velocity and skin frictional stress on the top and bottom plates were obtained.

차량용 열교환기의 주름진 루터 휜에 대한 3차원 성능해석 (Three Dimensional Analysis for the Performance of the Corrugated Louver Fin for a Vehicle Heat Exchanger)

  • 박봉수;조재헌;한창섭
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.116-126
    • /
    • 2002
  • A three dimensional numerical analysis of the corrugated louver fin for a vehicle heat exchanger was performed. The heat transfer rate and the air pressure drop of the corrugated louver fins for a slim heater were compared with experimental results at the same operating conditions. As for the slim heater fin, we found an optimum fin pitch at certain operating conditions. As the fin pitch increased, the air pressure drop decreased. The vertical or flat top fin was superior to the common declined fin in the aspect of heat transfer performance. As the louver length increased, both the heat transfer rate and the air pressure drop increased.

이산화탄소의 마이크로 핀관 내 상향유동 증발열전달 특성에 관한 연구 (An experimental study on heat transfer characteristics in a vertical micro-fin tube during evaporation process of carbon dioxide flowing upward)

  • 김용진;조진민;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.247-251
    • /
    • 2007
  • Because of the ozone layer depletion and global warming, new alternative refrigerants are being developed. In this study, evaporation heat transfer characteristics of carbon dioxide flowing upward in a vertical micro-fin tube have been investigated by experiment. Before a test section, a pre-heater is installed to adjust the inlet quality of the refrigerant to a desired value. The micro-fin tube with outer diameter of 5 mm and length of 1.44 m was selected as the test section. The test was conducted at mass fluxes of 318 to $530\;kg/m^2s$, saturation temperature of -5 to $5^{\circ}C$, and heat fluxes of 15 to $30\;kW/m^2$. As the vapor quality increases, the heat transfer coefficients of carbon dioxide are increased, and the heat transfer coefficients increase when the heat fluxes and saturation temperatures increase, and there was not much of influence of mass flux on the heat transfer coefficients.

  • PDF