• Title/Summary/Keyword: vertical distribution

Search Result 2,014, Processing Time 0.028 seconds

Analysis of the stress distribution under a driving lugged wheel by photoelastic method (광탄성법(光彈性法)에 의(依)한 러그달린 구동륜하(駆動輪下)의 응력분포(應力分布)에 관(關)한 해석(解析))

  • Kim, Jin Hyun;Choi, Sang In
    • Journal of Biosystems Engineering
    • /
    • v.8 no.2
    • /
    • pp.11-17
    • /
    • 1983
  • Stress distribution under a driving lugged wheel was obtained by photoelastic method. The distribution showed two distinct parts, one part is due to sinkage and other due to compression. Results of the study are summarized as follows. 1. The tangential reactions of sinkage as well as compressing parts were directly proportional to tangential load to the driving wheel, that's appeared to be thrust of the driving wheel. The normal reactions of both sinkage and compressing parts were directly proportional to the vertical load to the driving wheel, that's appeared to be resistance against wheel motion. 2. When the tangential load was constant, changing the vertical load did not show any significant thrust variation of the driving wheel. 3. Under the condition of this experiment, the ratio of vertical load to tangential load (T.L/V.L) must be greater than 1.0 in order for the wheel to roll.

  • PDF

Spatial Distribution of Fine Roots in Quercus mongolica and Quercus acutissima Stands (신갈나무와 상수리나무 숲에서 細根의 空間分布)

  • Kwak, Young-Se;Kim, Joon-Ho
    • The Korean Journal of Ecology
    • /
    • v.17 no.2
    • /
    • pp.113-119
    • /
    • 1994
  • Vertical and horizontal distribution and seasonal changes of fine roots as well as inorganic nitrogen content in soil were determined in Quercus mongolica and Quercus acutissima stands in Mt. Taemosan, Seoul. The vertical distribution of fine rooth phytomass showed a power-functional decrease as descending soil depth. Fine root phytomass was 170 g $DM/m^2$(46%) and 225 g $DM/m^2$(47%) in top soil of 5 cm depth, and 370 g $DM/m^2$ and 480 g $DM/m^2$ from soil surface to 50 cm depth in Q. mongolica and Q. acutissima stands, respectively. Fine roots in relation to the distance from the nearest tree were evenly distributed horizontally in both stands. Fine roots phytomass in top soil of 5 cm depth reached a peak in June, and thereafter decreased gradually in both stands. Patterns of seasonal changes in fine root phytomass were closely related to inorganic nitrogen and moisture content.

  • PDF

Seasonal fluctuation and vertical distribution of Paraphysomonas(Chrysophyceae) off the coast near Syowa Station, East Ongul Island, Antarctica: -(Preliminary report)

  • TAKAHASHI Eiji
    • 한국생태학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.55-62
    • /
    • 1999
  • Four species of Paraphysomonas collected from the fast- ice covered area Syowa Station, East Ongul Island ($69^{\circ}00'S,\;39^{\circ}35'$) ,Antarctica occurred in the seawater throughout the year and occasionally in the sea ice. P.. antarctica is distributed to a water depth of 35m at 51.3 during the period from August 1983 to January 1984 and also down to 600m St. 5 in September 1983 at cell concentrations of 300-350 cells/ml. The Paraphysomonas spp. were dominant during the period from July to November 1983 in the area studied. The mode of the occurrence and vertical distribution of Paraphysomonas apparently coresponds to those of the bacteria and orgarnic debris-like matter in the seawater. The main components of the plankton population in the area studied, under ice-covered conditions, are Paraphysomonas, Choanoflagellates and bacteria. This work clarified that Paraphysomonas is one o f the most important bacterivores in the microbial loop of the Antarctic marine ecosystem.

  • PDF

Comparison of the effects of physico-chemical factors on the zonation and vertical distribution of benthic microalgal communities in the tidal flats of south-west Korea (한국 남서부 갯벌의 저서성 미세조류의 대상분포와 수직분포에 미치는 이화학적 요인의 효과에 관한 비교)

  • 이학영
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.529-535
    • /
    • 2002
  • Efffcts of physico-chemical factors on the zonation and vertical distribution of benthic microalgal communities in the tidal flats of Youngkwang and Canaiin, Korea, were studied. Concentrations of nutrients were low throughout the study period. A 38 species of benthic microaigae was identified. Most of the algae were pennate diatoms with small size. Cell numbers at silty sediments were higher than sandy sediments, and showed high patchy distribution. Zonal distributions of benthic microalgae showed higher variation from silty sediment than sandy sediments. Benthic microalgae showed vertical migration within the upper few mm of sediment with periodicity closely related to tidal cycles. Maximum cells were observed from 0 mm depth both sandy and silty sediments. Cells of benthic microalgae in the 1 - 2 mm depth decreased after desiccation of sediments. The variation of cells was higher at sandy sediments than silty sediments. Cell numbers of benthic microalgae showed no positive relationships with pH and nutrinets except NH$_4$-N.

Composition of Marine Algal Community at the Intertidal Zone in Gwangyang Bay, South Sea, Korea (한국 남해안 중부에 위치한 광양만 조간대의 해조상과 군집)

  • Choi, Chang-Geun;Huh, Sung-Hoi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.3
    • /
    • pp.201-207
    • /
    • 2008
  • The seasonal variation and vertical distribution of the marine algal community were investigated using the quadrat method from February 2006 to January 2007 at 10 sites in Gwangyang Bay, Korea. In total, 48 red, 17 brown, and 13 green algal taxa were identified. The algal vertical distribution in the intertidal zone was characterized by Ulva pertusa, while the upper tidal zone was dominated by Gelidium divaricatum. The middle zone was primarily composed of Enteromorpha linza, Sargassum thunbergii, and Chondracanthus intermedia, whereas Hizikia fusiformis, Sargassum thunbergii, Gelidium amansii, and Corallina pilulifera characterized the low tidal zone. Results of cluster analysis indicated that algal composition fell into two groups, which were composed of species in the inland and open sea. In conclusion, the number of species, diversity, and abundance of vegetation in this area were remarkably reduced compared to previous studies in Gwangyang Bay.

Vacuum distribution with depth in vertical drains and soil during preloading

  • Khan, Abdul Qudoos;Mesri, G.
    • Geomechanics and Engineering
    • /
    • v.6 no.4
    • /
    • pp.377-389
    • /
    • 2014
  • The vacuum consolidation method which was proposed by Kjellman in 1952 has been studied extensively and used successfully since early 1980 throughout the world, especially in East and Southeast Asia. Despite the increased successful use, different opinions still exist, especially in connection to distribution of vacuum with depth and time in vertical drains and in soil during preloading of soft ground. Porewater pressure measurements from actual cases of field vacuum and vacuum-fill preloading as well as laboratory studies have been examined. It is concluded that (a) a vacuum magnitude equal to that in the drainage blanket remains constant with depth and time within the vertical drains, (b) as expected, vacuum does not develop at the same rate within the soil at different depths; however, under ideal conditions vacuum is expected to become constant with depth in soil after the end of primary consolidation, and (c) there exists a possibility of internal leakage in vacuum intensity at some sublayers of a soft clay and silt deposit. A case history of vacuum loading with sufficient subsurface information is analyzed using the ILLICON procedure.

Air Distribution Performance According to the Gap Opening of a Temperature Controlled Diffuser (냉난방 온도감지 디퓨져의 간극변화에 따른 기류분포 특성)

  • Han Hwataik;Shin Min-Woo;Yom Chol-Min;Choi Sun-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.180-185
    • /
    • 2006
  • This study has been conducted in order to develop a temperature-controlled round pan diffuser with variable-openings. Flow visualization was performed to investigate the airflow patterns according to gap openings. The velocity profiles were measured using an omni-directional anemometer for two cases, i.e. a horizontal and a vertical discharge conditions. Numerical simulation also confirms there is a narrow range of gap openings where a horizontal discharge shifts to a vertical discharge. The air distribution performance index increases abruptly when the air discharge shifts from vertical to horizontal direction.

The Effects of Private Guanxi and Organizational Relationship Type on Quality of Relationship and Performance of Distribution Channel -Focused on Apparel Manufactures and Distribution in China- (중국의류산업에서 제조업체와 유통업체간 개인 Guanxi(관계, 關係)와 조직관계가 조직관계의 질 및 유통경로성과에 미치는 영향)

  • Moon, Young-Ok;Park, Na-Ri;Park, Jae-Ok
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.11
    • /
    • pp.1760-1770
    • /
    • 2008
  • The purpose of this study was 1) to find effects of private Guanxi and organizational relationship on quality of organizational relationship, 2) to find effects of private Guanxi and organizational relationship on performance of distribution channel, and 3) to also find effects of quality of organizational relationship on performance of distribution channel. Apparel manufacturers and distributors in China participated in the study. Random sampling method was used to collect the data. Data from 173 questionnaires were used for the statistical analysis. Factor analysis, Cronbach's alpha coefficient, and regression analysis was conducted. Two factors of private Guanxi were classified(i.e., affective Guanxi, instrumental Guanxi). Three factors of organizational relationship type were identified(i.e., opportunistic relationship, cooperative relationship, vertical relationship). The result indicated that affective Guanxi in terms of private Guanxi positively affected on quality of organizational relationship. Cooperative relationship and vertical relationship in terms of organizational relationship positively affected on quality of organizational relationship. Affective Guanxi positively affected on non-financial performance and financial performance in terms of performance of distribution channel. Instrumental Guanxi in terms of private Guanxi positively affected on financial performance only. Cooperative relationship in terms of organizational relationship positively affected on non-financial performance and vertical relationship positively affected on financial performance. Quality of organizational relationship positively affected on non-financial performance and vertical relationship positively affected on financial performance.

Fiber orientation distribution of reinforced cemented Toyoura sand

  • Safdar, Muhammad;Newson, Tim;Waseem, Muhammad
    • Geomechanics and Engineering
    • /
    • v.30 no.1
    • /
    • pp.67-73
    • /
    • 2022
  • In this study, the fiber orientation distribution (FOD) is investigated using both micro-CT (computerized tomography) and image analysis of physically cut specimens prepared from Polyvinyl Alcohol (PVA) fiber reinforced cemented Toyoura sand. The micro-CT images of the fiber reinforced cemented sand specimens were visualized in horizontal and vertical sections. Scans were obtained using a frame rate of two frames and an exposure time of 500 milliseconds. The number of images was set to optimize and typically resulted in approximately 3000 images. Then, the angles of the fibers for horizontal sections and in vertical section were calculated using the VGStudio MAX software. The number of fibers intersecting horizontal and vertical sections are counted using these images. A similar approach was used for physically cut specimens. The variation of results of fiber orientation between micro-CT scans and visual count were approximately 4-8%. The micro-CT scans were able to precisely investigate the fiber orientation distribution of fibers in these samples. The results show that 85-90% of the PVA fibers are oriented between ±30° of horizontal, and approximately 95% of fibers have an orientation that lies within ±45° of the horizontal plane. Finally, a comparison of experimental results with the generalized fiber orientation distribution function 𝜌(θ) is presented for isotropic and anisotropic distribution in fiber reinforced cemented Toyoura sand specimens. Experimentally, it can be seen that the average ratio of the number of fibers intersecting the finite area on a vertical plane to number of fibers intersecting the finite area on a horizontal plane (NVtot/NHtot) cut through a sample varies from 2.08 to 2.12 (an average ratio of 2.10 is obtained in this study). Based up on the analytical predictions, it can be seen that the average NVtot/NHtot ratio varies from 2.13 to 2.17 for varying n values (an average ratio of 2.15).

The Effect of Header and Channel Angle Variation on Two-Phase Flow Distribution at Multiple Junctions (헤더-채널 분기관의 각도변화가 2상 유동 분배에 미치는 영향에 대한 연구)

  • Lee, Jun Kyoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.559-566
    • /
    • 2015
  • The main objective of this work is to experimentally investigate the effect of angle variation on the distribution of two-phase flow at header-channel junctions. The cross-sections of the header and the channels were fixed at $16mm{\times}16mm$ and $12mm{\times}1.8mm$, respectively. Air and water were used as the test fluids. Four different header-channel positions were tested : Vertical header with Horizontal channels (case VM-HC), Horizontal header with Horizontal channels (case HM-HC), Horizontal header with Vertical Downward channels (case HM-VDC), and Horizontal header with Vertical Upward channels (case HM-VUC). In all cases, liquid flow distribution tended to decrease gradually in the upstream header region. However, in the downstream region, different trends could be seen. The reason for these different tendencies were identified by flow visualization in each case. The standard deviations for the liquid and gas flow distribution in each case were calculated, and the case of VM-HC had the lowest values compared to other cases because of the symmetrically distributed liquid film and strong flow recirculation near the end plate.