• 제목/요약/키워드: vertical alignment

검색결과 335건 처리시간 0.021초

PDT-VA 셀을 이용한 전기광학 특성 (Electro-optical performance using a PDT-VA cell)

  • 김형규;황정연;서대식;한은주;김재형
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 추계학술대회논문집
    • /
    • pp.133-136
    • /
    • 2000
  • We investigated the improvement of viewing angle using a patterned double twisted (PDT) vertical-alignment (VA) cell mode on a homeotropic alignment layer. Good voltage-transmittance curves for negative dielectric anisotropic nematic liquid crystal (NLC) using the PDT-VA cell without a negative compensation film were obtained. The viewing angle of the PDT-VA cell without a negative compensation film was wider than that of a conventional VA cell.

  • PDF

PDT-VA 셀을 이용한 전기광학 특성 (Electro-optical performance using a PDT-VA cell)

  • 김형규;황정연;서대식;한은주;김재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.133-136
    • /
    • 2000
  • We investigated the improvement of viewing angle using a patterned double twisted (PDT) vertical-alignment (VA) cell mode on a homeotropic alignment layer. Good voltage-transmittance curves for negative dielectric anisotropic nematic liquid crystal (NLC) using the PDT-VA cell without a negative compensation film were obtained. The viewing angle of the PDT-VA cell without a negative compensation film was wider than that of a conventional VA cell.

  • PDF

인공위성 정렬 측정 정확도 향상을 위한 연구 (A Study on Satellite Alignment Measurements Accuracy Improvement)

  • 최정수;김인걸
    • 한국항공우주학회지
    • /
    • 제48권12호
    • /
    • pp.987-995
    • /
    • 2020
  • 고성능 탑재체들과 자세제어 센서들 간의 정밀정렬은 인공위성의 정확한 자세지향 및 높은 지향 안정성을 위해 필수적이다. 위성 개발사들은 조립 및 시험기간 동안 위성 정렬을 위해 데오드라이트 측정 시스템을 주로 사용한다. 데오드라이트 측정 시 시선 방향 오차, 수평축의 오차, 수직방향 인덱스 오차 그리고 수직축 오차로 인해 측정오차가 발생할 수 있다. 이러한 오차들 뿐 아니라 다수의 데오드라이트를 사용한 측정 시 발생할 수 있는 오차들을 정렬큐브 측정실험을 통해 분석하였다. 정렬큐브 측정실험을 기반으로 정렬측정 정확도를 향상시킬 수 있는 방법이 제안되었고, 측정 결과 위성의 설계 요구조건도 만족시킬 수 있었다.

PDP용 수직형 구조의 근접 노광장치 개발 (Development of Proximity Exposure System with Vertical Structure for Plasama Display Panel)

  • 박정규;정수화;이항부
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2371-2380
    • /
    • 2000
  • In this paper, we developed the proximity exposure system with the vertical structure of glass and mask stage to minimize the mask's warp caused by the pull of gravity. This system, which canirradiate the ultra violet through 1440 H 850 $\textrm{mm}^2$ and 1330X 1015 $\textrm{mm}^2$ exposure area, has the followingcharacteristics. The glass stage can be inclined by 80 degrees at vertical structure to load substrate withsafety on it. When the glass stage is the vertical state, the gap control, alignment control and exposureof ultra violet are executed. So, it enhances the pattern uniformity by minimizing the mask's warp. Theglass stage can also control the gap between the mask and the substrate by the coarse and fine motioncontrol. The mask stage can adjust the posture of photomask to the position of substrate by imageprecessing method. The galss stage for the gap control and the mask stage for the alignment aredesigned independently for each function.

수직배향 네마틱 액정셀에서의 주입속도에 미치는 전기장 효과 (Effect of Electric field on an Injection Velocity in a Vertically Aligned Nematic Liquid Crystal)

  • 전연문;김상균;김연식;안명환;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제19권7호
    • /
    • pp.695-699
    • /
    • 2006
  • Injection time of liquid crystal (LC) by capillary action in a vertically aligned (VA) nematic LC cell takes longer than that in a homogeneously aligned (HA) LC cell because Miesowicz viscosity in the former is bigger than that in the latter. To reduce liquid crystal injection time in the VA cell, we applied vertical electric field while injecting so that the orientation of LC molecules is changed from vertical alignment to homogeneous alignment. Consequently, the injection speed is improved by 25 % when compared with the cell without an applied field.

수직 광폴리머 표면을 이용한 VA-IPS 셀의 전기 광학 특성 (EO Characteristics in the Vertical-Alignment (VA)-In Plane Swiching (IPS) Cell on a Homeotropic Photopolymer Surface)

  • 정은아;황정연;김재형;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.945-948
    • /
    • 2002
  • We studied electro-optical (EO) performances of a vertical-alignment (VA)-in plane switching (IPS) cell on a photopolymer surfaces. The VA-IPS cell, dark in voltage-off state, reveals bright uniformity in all directions due to the dual domainlike dierector configuration in the voltage-on state. For voltage-transmittance (V-T) measurement, the transmittance characteristics of the VA-IPS cell on the photopolymer surface was better than that of the VA-IPS cell on a polyimide(PI) surface.

  • PDF

수직배향 액정 디스플레이의 시야각 스위칭 (Viewing Angle Switching of Vertical Alignment Liquid Crystal Display)

  • 임영진;정은;최민오;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.49-50
    • /
    • 2006
  • We have developed vertical alignment liquid crystal display (VA-LCD), of which the viewing angle can be controlled. The VA-LCD has the function of switching between the wide viewing mode and narrow viewing angle mode using one homogeneous aligned (HA) LC layer and one compensation film with a negative C-plate. The retardation of the HA layer at off axis can be controlled by applying an electric field while keeping the retardation value to be zero at normal direction. Consequently, the device exhibits a viewing mode over $170^{\circ}$ in terms of CR = 10 in wide viewing mode and about $60^{\circ}$ in terms of CR = 2 in narrow viewing angle mode m horizontal direction.

  • PDF

PVA모드에서 공통 전극 패턴을 통한 전기장 간섭의 감소 효과 (Reducing of cross-talk by patterning of common electrode in the patterned vertical alignment (PVA) mode)

  • 전연문;김연식;황성진;이승희;류재진;김경현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.43-44
    • /
    • 2006
  • We have studied electro-optical characteristics and stability of liquid crystal director depending on electrode patterning of common electrode on top substrate in patterned vertical alignment (PVA) mode. In the present studies, new type of common electrode pattern was suggested to enhance a dark state by reducing interference area due to data signal. According to the simulation result, PVA device with new common electrode pattern contributed to Improvement of an aperture ratio.

  • PDF

An Optical Configuration for Vertical Alignment Liquid Crystal cell with Wide Viewing Angle

  • Ji, Seung-Hoon;Lee, Gi-Dong
    • Journal of Information Display
    • /
    • 제9권2호
    • /
    • pp.22-27
    • /
    • 2008
  • We propose an optical configuration of a vertical alignment (VA) liquid crystal (LC) cell to eliminate the light leakage in the diagonal direction. VA LC cell has an excellent contrast ratio in the normal direction due to the no phase-retardation. However, change of the phase-retardation occurs in all directions, which causes the light leakage and deteriorates the characteristics of the dark state. We designed the LC cell structure composed of multiple combinations with two A-plates and two C-plates in order to achieve wide viewing property on the Poincare sphere. From calculations, we show that the proposed structure can improve the viewing angle characteristics by compensating for the light leakage in all directions.

틸팅열차의 주행안전성과 고저틀림의 상관성 분석 (Characteristics of the Running behavior and Safety for Tilting train due to Vertical Alignment)

  • 최일윤;엄주환;임윤식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1937-1942
    • /
    • 2010
  • Vehicle dynamic behavior should be investigated to establish the track irregularity criteria because they have an impact on vehicle dynamic behavior. The tilting train which have been developed in Korea will be operated on the conventional line. Therefore, it should be checked that the track irregularity criteria of conventional line is still available for the new vehicle. In this paper, the influence of vertical alignment on running behavior and safety for tilting train was instigated by numerical analysis. The wavelength and amplitude of vertical alignment were considered in scenario of this numerical analysis. This research is based on just numerical analysis and the final result which include measurement will be published in the future.

  • PDF