• Title/Summary/Keyword: ventilator

Search Result 568, Processing Time 0.028 seconds

Critical illness neuromyopathy

  • Park, Soo-Hyun;Jeong, Yoon-Jung;Kim, Nam-Hee
    • Annals of Clinical Neurophysiology
    • /
    • v.22 no.2
    • /
    • pp.61-66
    • /
    • 2020
  • Critical illness neuromyopathy (CINM) is a common but frequently underdiagnosed condition in critically ill patients that contributes to ventilator weaning failure and limb weakness in intensive care unit (ICU). CINM is subdivided into critical illness polyneuropathy and critical illness myopathy, and the occurrence of these conditions in the ICU is associated with multiple organ failure due to sepsis or certain medications. CINM survivors might have persistent functional disabilities and a poor quality of life. This situation demonstrates the need for efforts to minimize or prevent CINM in critically ill patients. This article provides a current overview of CINM and the associated clinical strategies.

External Compression of Bronchus by Aneurysm from Divided Major Aortopulmonary Collateral Artery after Unifocalization (단일화수술 후 분리되어 남은 체폐동맥 부행혈관에 의한 기관지 압박)

  • 이현성;박영환;홍유선;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.12
    • /
    • pp.1135-1139
    • /
    • 1999
  • Multistage unifocalization and complete repair have been performed for pulmonary atresia ventricular septal defect and major aortopulmonary collateral arteries. We reported a case that divided major aortopulmonary collateral artery was changed into an aneurysm that compressed the left main bronchus. A 1-year-8-month old boy was operated. The Rastelli operation with left pulmonary artery reconstructuion ligation of patent ductus arteriosus and take-down of right Blalock-Taussing shunt was performed on the patient who had pulmonary atreisia ventricular septal defect patent ductus arteriosus and MAPCA at 1 year and 8 months of his age. He previously underwent the unifocalization and right B-T shunt at 9 months of age,. He repeatedly had difficulty in weaning from the mechanical ventilator, After removing the aneurysm from the divided MAPCA that compressed the left main bronchus externally it was possible to wean him from the mechanical ventilator.

  • PDF

A Study on the Performance of Heat Recovery Ventilators for Apartment Houses (공동주택용 폐열회수형 환기장치의 성능에 관한 측정 연구)

  • Chang, Hyun-Jae;Hong, Seok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.26-34
    • /
    • 2008
  • Heat recovery ventilator(HRV) is recommended to improve indoor air quarlity (IAQ) and energy conservation in apartment houses. Recently, in Korea, HRV is produced from many manufacturers. However, there have been not so many experiences to apply HRV in apartment houses and verification on the performance such as heat exchange efficiency, carry-over rate, internal leakage, etc. have not been carried out sufficiently. So in this study, fan performance, heat exchange efficiency, air leakage, internal exhaust leakage, external leakage and sound level of HRV were examined for selected HRV models under domestic and international standard. Results of performance test, there were need to improve latent heat exchange efficiency and sound level of HRV.

Consideration of Heat Recovery Ventilator from Ventilating Standpoint (환기관점에서 본 열교환 환기유니트)

  • Song, Jun-Won;Kang, Il-Kyung;Kim, Tae-Hee;Shin, Yong-Sup;Park, Jae-Sung;Choi, Won-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.417-422
    • /
    • 2006
  • On trends of 'well-being', heat recovery ventilators(HRV) are recently installed in high rise buildings. HRV is not energy saving instrument but ventilating one. But many people have not been aware of the accurate fact. In this study, performances of HRV are tested under foreign and domestic standards. Especially air-tightness is measured three times by using gas concentration method and pressing equipment. Wet effective ventilating air volume is acquired by solving gas concentration equations. After research air-tightness and effective ventilating air volume must be more focused on than heat transfer efficiency to select the optimal HRV. Heat transfer efficiency must be adjusted by air-tightness results.

  • PDF

Home mechanical ventilation in children with chronic respiratory failure: a narrative review

  • Soyoung Kwak
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.2
    • /
    • pp.123-135
    • /
    • 2023
  • Advances in perinatal and pediatric intensive care and recent advances in mechanical ventilation during the last two decades have resulted in an exponential increase in the number of children undergoing home mechanical ventilation (HMV) treatment. Although its efficacy in chronic respiratory failure is well established, HMV in children is more complex than that in adults, and there are more considerations. This review outlines clinical considerations for HMV in children. The goal of HMV in children is not only to correct alveolar hypoventilation but also to maximize development as much as possible. The modes of ventilation and ventilator settings, including ventilation masks, tubing, circuits, humidification, and ventilator parameters, should be tailored to the patient's individual characteristics. To ensure effective HMV, education for the parent and caregiver is important. HMV continues to change the scope of treatment for chronic respiratory failure in children in that it decreases respiratory morbidity and prolongs life spans. Further studies on this topic with larger scale and systemic approach are required to ensure the better outcomes in this population.

Survey on Self Care, Respiratory Difficulty, Sleep Impediment, Anxiety and Depression among Patients with Neuromuscular Disease dependent on Home Mechanical Ventilator (재가 가정용인공호흡기 적용 신경근육계 질환자의 호흡곤란, 수면장애, 불안 및 우울에 관한 연구)

  • Hwang, Moon Sook;Lee, Mi Kyung;Song, Jong Rye
    • Korean Journal of Adult Nursing
    • /
    • v.28 no.5
    • /
    • pp.595-606
    • /
    • 2016
  • Purpose: This study aimed to investigate the influencing factors on self care, respiratory difficulty, sleep impediment, anxiety and depression among patients with neuromuscular disease who are dependent on Home Mechanical Ventilator (HMV). Methods: 157 patients were recruited through hospital based home nursing care departments and HMV rental centers. Data were collected by questionnaires. The analytic methods were n(%)/$M{\pm}SD$, $x^2$/t-test or ANOVA and multiple linear regression. Results: Patients with Amyotrophic lateral sclerosis were more likely to utilize HMV, had shorter periods of morbidity and the most extended daily use of HMV. As for medical equipment, they had ambu-bag (87.2%) and oxygenator (15.4%). Reports of respiratory difficulty and sleep impediment were low. There were no significant difference. In contrast, reported anxiety and depression were high and showed significant difference between non invasive HMV and invasive HMV. Anxiety contributes to respiratory difficulty (t=3.62, p=.002), sleep impediment (t=2.06, p=.042), and depression (t=7.24, p<.001). However, home nursing care exerts a positive influence in reducing anxiety (t=-2.73, p=.008). Conclusion: Anxiety contributes to respiratory difficulty, sleep impediment, and depression. However, those who use home nursing care reported less anxiety. Home nursing care positively impacts patients dependent on HMV as a practical service and available resource.

Efficacy and Safety of Aerosolized Colistin in the Treatment of Ventilator-Associated Pneumonia: A Systematic Review and Meta-analysis (기계환기관련 폐렴치료 시 Aerosolized Colistin의 효과 및 안전성에 대한 체계적 문헌 고찰 및 메타분석)

  • Paik, Minwoo;Jeung, Kyeonghye;Kim, Eun Young
    • Korean Journal of Clinical Pharmacy
    • /
    • v.27 no.4
    • /
    • pp.207-213
    • /
    • 2017
  • Background: It is recommended to use aerosolized (AS) colistin in patients undergoing mechanical ventilation therapy as an adjunctive in the latest guidelines, in spite of high nephrotoxicity and limited studies. In this study, systematic reviews and meta-analyzes were conducted to evaluate the safety and efficacy of AS colistin in patients with ventilator-associated pneumonia Methods: Two authors independently searched related literature published from Pubmed and EMBASE until July 2016 and included a study comparing adjunctive AS colistin with intravenous (IV) colistin monotherapy. The primary outcome was the clinical response rate, the secondary outcome was the overall mortality, and nephrotoxicity. The publication bias was evaluated using the Egger's test. Results: Of the total 279 articles, nine were finally included in the final analysis. There was a significant difference between the adjunctive AS colistin group and the IV colistin monotherapy group for the treatment-response rate (odds ratio (OR), 1.56; 95% CI, 1.14-2.14; p = 0.005; $I^2=36%$), although there was no significant difference in overall mortality (OR, 0.77; 95% CI, 0.57-1.04; p = 0.09; $I^2=20%$). However, there was no significant difference between the two groups in nephrotoxicity (OR, 1.13; 95% CI, 0.74-1.74; p = 0.57; $I^2=4%$). Conclusion: The addition of aerosolized colistin to IV colistin monotherapy showed better results in terms of efficacy than IV colistin monotherapy and did not show any significant difference in terms of total mortality and nephrotoxicity. Additional large-scale studies of this need to be verified.