• Title/Summary/Keyword: ventilation house

Search Result 302, Processing Time 0.032 seconds

The Characteristic of Decoration in Indonesian Traditional House - Focused Javanese Hous - (인도네시아 전통주택의 의장 특성에 관한연구 - 자바주택을 중심으로 -)

  • Kim, Do-Yeon;Ju, Seo Ryeung;Oh, Hye-Kyung
    • Journal of the Korean housing association
    • /
    • v.25 no.6
    • /
    • pp.111-121
    • /
    • 2014
  • The purpose of the study is to understand the unique characteristics of decoration style in traditional Javanese houses. Reviewing literature and visiting site were applied as the research method. Javanese House can be divided into three parts; roof, wall and floor. First, the roof of the traditional Javanese House is the most unique and important decorative element. The roofs are covered with roof-tiles and have clay carving ornaments on top. Usually there are no ceilings, just exposed to the oblique shape roof, which are made of wood to enable air ventilation. Joglo roof is the outstanding and representative roof type of Javanese houses. There is artistic and constructive roof structure named as tumpang sari in Joglo roof. The decoration on tumpang sari is the most colorful and symbolic ornaments. Secondly, the most unique element in the wall is the gebyok. Gebyok is made of wood and full of carved ornament, which has an artistic appearance, and also important function. The top part of doors are designed as perforated woodcarving, which give both aesthetic and ventilation purposes. Last, the stratified floor is begin with ground yard, then veranda that made from hardened clay, and main room constituted with a wood scaffold to provide air circulation and remove the humidity of the ground. The decorations of the column stand (umpak) are unique, where usually lotus flower is carved into black stone or lime stone. The outside of the buildings in Java Houses is not decorated by colors or symbols, whereas colors are only used in temples, pavilion or in royal housings. Instead they have carvings and decorations on important structural elements such as columns and beams inside. The ornaments and colors of decorations symbolize their god, ancestors and piece.

Effects of the Odor Abatement System in a Naturally Ventilated Growing Finishing Pig House (자연환기식 육성.비육돈사의 악취탈취장치 적용효과)

  • Lee, S.H.;Yun, N.K.;Kim, K.W.;Yum, S.H.;Cho, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2008
  • Ammonia gas is one of the malodorous gases from swine production facilities, such as manure storage tank, manure fermentation facilities, and livestock houses, etc. Ammonia gas from swine house is being emitted at relatively low concentrations throughout the year. Therefore, livestock facilities were continuously ventilated to supply fresh air for respiration of the animals internal the livestock facilities. The swine facilities need very high ventilation rate to control the inside environmental conditions. The deodorization system of the livestock facilities must be developed considering the ventilation rates. The odor abatement system was installed in order to improve the internal environment of the naturally ventilated growing-finishing pig house. The system which distributes the deodorized air into inner space of the swine house by using plastic duct was installed. Since the internal environment, effected by the operation of the odor abatement system, is monitored by closing the winch curtain installed on the side wall of the pig house, the experiment was practiced at the season when the internal environment becomes aggravated, winter. The effects on the improvement in the internal environment of swine house by operating the odor abatement system are as follows ; 1. By re-distributing the air which was deodorized by the odor abatement system installed in the pig house, the result showed that the concentration of ammonia gas is decreased approximately 33.3% compared with that before operating odor abatement system. 2. The effect on the pig house's ammonia gas reduction was found that the ventilation rate was less than $0.5m^3$/min head. The effect of the operation of the odor abatement system showed to be scarce when the ventilation rate increases because of the influx of external fresh air makes the quantity of diluted air more than those of the odor abatement system. 3. The perishment rate of the pigs which were brooded until slaughtering decreased about 3.8% by operating the odor abatement system in the growing-finishing pig house. Also, after operating the odor abatement system, the stinging of the eyes, suspension dust, etc were decreased when going into swine house for management.

  • PDF

환기시스템에 의한 Sick House 대책

  • Kimura, Hiroshi
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.9
    • /
    • pp.46-51
    • /
    • 2003
  • "환기"는 생활용품 등으로부터의 오염물질 및 불특정 물질의 농도 저감이 가능하기 때문에 Sick House 대책으로서의 중요한 대책기술이다. 본 고에서는 집합주택을 대상으로 한 중앙공조 환기방식 및 배기 중앙 환기방식의 사례를 보여주고, 시스템의 구성기술과 오염물질의 농도 저감효과에 대해서 기술한다. 또한, 대표적인 오염물질인 포름알데히드의 건자재로 부터의 발산량은 온습도, 환기량 및 건자재의 표면적 비율 등의 영향인자에 따라 변화하므로, 필요 환기량은 이들의 영향요인을 고려하여야 한다는 것을 기술한다.

  • PDF

A Study on the Windows and Doors of Jecheon Park Dosu's House and Jeong Wontae's House (제천 박도수가옥 및 정원태가옥의 창호에 관한 연구)

  • Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.5
    • /
    • pp.96-103
    • /
    • 2014
  • This study investigated the windows and doors of Jecheon Park Dosu's House and Jecheon Jeong Wontae's House, designated as a Important Folklore Cultural Heritage in Jecheon. It aimed to contribute to the study of traditional house, and to the conservation policy of architectural Heritage in Jecheon. This study used the research methods of the literature analysis and the field survey, and it was to analyze the spatial characteristics of the windows and doors in each building. The result are as followings. Firstly, the wooden board door(板張門) of a hinged door type is found in the kitchen of An-chae, and the Bongchang(封窓) and Gwangchang(光窓) towards the courtyard is installed for ventilation and lighting. Secondly, the slender-ribbed windows and doors(細箭 窓戶) of double swinging type towards the courtyard is installed in An-bang, and Merum(遠音) is found. Thirdly, the framed panel door(骨板門) of a hinged door type towards the backyard is found in Daechung(大廳). Lastly, the slender-ribbed windows and doors of double swinging type towards the outside is found in Sarang-bang of Sarang-chae, and Merum(遠音) is installed. Especially, double skin windows and doors is installed in Jecheon Park Dosu's House.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (건축물에너지효율등급 기밀시험이 등급에 미치는 영향분석)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Ju, Jung-Kyeong
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.40-45
    • /
    • 2014
  • The ventilation frequency of 0.5 times in residential facilities is applied mandatorily to the housing facilities containing more than 100 house units to improve the indoor air quality and create comfortable interior conditions and pleasantness for residents. The Building Energy Efficiency Rating system requires the implementation of leakage test based on ventilation frequency with the test results being reflected in the efficiency ratings, thereby stimulating the precise construction of the fittings in the periphery of windows and savings of energy that can be lost due to the infiltration air. The inspection results of the Building Energy Efficiency Rating at the site showed that the ventilation frequency was in the range between 0.63 and 0.71 and that the difference was found to have a significant effect on the amount of energy reduction. It is urgent to conduct the study on highly leakage-proof buildings and construction methods, along with the expansion of mandatory leakage-proof diagnosis of non-residential buildings, considering the mandatory ventilation frequency below 0.6 for passive houses under the European standards and the target set by Korea to introduce the passive house, the rigorous standard for energy efficiency in buildings and mitigating their ecological footprint, by 2017 and achieve the zero house by 2025.

A Study on Energy Requirement Variation According to Energy Efficiency Rating Evaluation and Design Variable of Standard Design of Rural Houses (농촌주택표준설계도 에너지효율등급평가 및 설계변수에 따른 에너지소요량 변화에 관한 연구)

  • Park, Mi-Lan;Ryoo, Yeon-Su;Choi, Jeong-Man;Seo, Hye-Won
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.2
    • /
    • pp.9-16
    • /
    • 2017
  • The study analyzed the heat losses and the building energy efficiency grade by the energy simulation using the ENERGY# and ECO2 programs for the three types of Standard design of rural houses. It was calculated the energy efficiency rating by the ECO2 program for the rural housing standard design, and the energy demand and the energy consumption by each factor were compared and analyzed. And it analyzed energy consumption by element of each house by ENERGY # program. As a result, first in the evaluation of the energy efficiency grade of buildings by the ECO2 program, the rating for primary energy requirement for the housing newly built by the standard design of rural house is expected to range from 2 to 4 with 189.3 to $238.7kWh/m^2.a$. Second, the energy loss of each part of standard design of rural housing occurs in the order of ventilation 39%, window 33%, outer wall 14%, roof 9%, bottom 5%, and energy loss through ventilation and window occurs more than 70%. Third, the most beneficial effects on the energy efficiency grade is obtained the lowest grade of all three types by 2 when the lowering of the window and door heat transmission rate and the lowering of the light density, and the heat exchange ventilation device is not installed. Fourth, in the standard design of rural housing, the energy demand is occupied by heating > hot water > lighting order, and the order of the weight is changed in order of heating > lighting > ventilation > hot water. Fifth, building energy efficiency assessment system needs to establish policy for fixing rural housing energy as a practical device to ensure energy performance and quality.

Investigations and Analyses of Duck Breeding Facilities in Jeollanam-do Province, Korea (전남지역 오리 사육시설 실태 조사 및 분석)

  • Kwon, Kyeong-seok;Yang, Kayoung;Kim, Jong-bok;Kim, Jung-kon;Jang, Donghwa;Choi, Sungmin;Lee, Sang-yeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Number of duck and its breeding facilities have been steadily decreasing for financial and social issues in Korea. Therefore, the 'turning point' for duck industry is strongly demanded. In this study, the questionary survey was carried out to provide backgrounds for developing policy and technology for duck breeding farms. The questionary survey aimed to investigate the information of operation strategy of farm, ventilation, cooling and heating. The total number of survey respondents was 74. In case of facility type, 55.4% of respondents stated they used greenhouse type, 31.3% for winch-curtain type, and 2.7% for windowless type (mechanically ventilated facility). More than 85% of the facilities were using 'natural ventilation', it meant that these situation can restrict the not only environmental control but also the supply policy for 'smart farm' of the Government. 44.6% used the combination of the cross-ventilation method and roof-ventilation method for ventilation operation in summer season, and 31.1% followed only the cross-ventilation method. In case of winter season, 36.5% used the cross-ventilation method, and 33.3% used the combination of cross and roof-ventilation, method. For the ventilation strategy, about 86.5% depended on farmer's experience. In case of heating and cooling, 79.7% were using kerosene heater for winter season, and 43.2% were using mist-spray for summer season, respectively. More than 75% stated that cooling and heating strategies were based on farmer's experience. From the analyses of the survey results, a few proposals for developing policy and technology for duck breeding farm was suggested.

A Study on the Ventilation Performance and Fire Characteristics with Different Types of Openings in External Wall of One Side Corridor Type Apartment (편복도형 아파트의 복도 외벽체 개구부 형태에 따른 환기성능 및 화재특성에 관한 연구)

  • Ko, Myeong Jin;Choi, Do Sung;Do, Jin Seok
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • The objective of this study is to verify the safety in case of fire and change of residential environment for different wall construction approaches in a stairways apartment house. In order to confirm that case_1, which is current case that most of wall is opened and the case 2, which upper part of wall is limitedly opened are compared and analyzed based on simulations of fire, escape and natural ventilation performance. The analysis reveals that possible escape time for case 1 was more than 600 seconds and for case 2 was 195 seconds. Since the escape times for both cases were over 128 seconds, it would be reasonable to assume that every resident would escape. The simulation results on natural ventilation performance shows the air change per hour of case 1 and case 2 were .19n/h and .16n/h and there was 1.2 times difference. However, the difference was too insignificant and it could be seen as that different approaches on wall construction would not significantly influence on natural ventilation performance.

Residents' Responses and Consciousness on Sick House Syndrome of Newly Built Apartments - Focusing on Cheongju - (신축 아파트 거주자의 새집증후군 반응 및 의식 조사 - 청주시를 중심으로 -)

  • Choi, Yoon-Jung
    • Journal of the Korean Home Economics Association
    • /
    • v.44 no.3 s.217
    • /
    • pp.103-113
    • /
    • 2006
  • The purpose of this study was to determine the present condition of sick house syndrome of newly built apartments a mid-sized city. The questionnaire survey was carried out from $19^{th}\;to\;22^{nd}$ of May 2004, with respondents consisting of 160 households living in two apartment complexes of Cheongju. Their residency periods after moving in were within $six{\sim}ten$ months. From the survey results of the respondents, sick house syndrome items revealed high percentages with the highest value of 49.3%. The respondents answered that they knew relatively well about sick house syndrome but they had no knowledge about 'bake-out'. The response percentages of sick house syndrome items in E complex, consisting of $106m^2$ (32 pyeong) size units, were significantly higher than those in A complex, consisting of $76m^2$ (23 pyeong) size units. This result suggests that the pollution levels emitted from interior materials in larger sized apartment units are higher than those in small sized units. The response percentages of sick house syndrome items in houses with fulfilled ventilation which had been ventilated before or after moving in were lower than in houses not ventilated.

Effect of a Resident and Indoor Environmental Characteristics on the House Dust Mites Allergen (주거환경 특성에 따른 집먼지진드기 항원량에 관한 조사)

  • Kim, Yong-Soon;Park, Jee-Won;Song, Young-Shin
    • Research in Community and Public Health Nursing
    • /
    • v.13 no.1
    • /
    • pp.79-88
    • /
    • 2002
  • Purpose: The purpose of this study was to identify the indoor environment i.e. house type and age, ventilation method, use of bed & sofa, cockroach, ants, etc. on HDM (House dust mites), especially Der fI allergen. Method: Samples of dust from mattresses, pillows and the floor were collected by using a vacuum cleaner from April. 2000. The amount of Group I allergen(Der. fI) of HDM (house dust mites) were measured by two-site ELISA. Indoor Environmental characteristics were accessed by using questionnaires on 178 house wives living in the Seoul area. Results: The amount of HDM allergen (Der fI) was higher in sofa using house. There were higher concentrations of HDM allergen (Der fI) in sofas made from quilt material than for those that were made from leather. Homes that had pets like dogs living in them had higher concentrations of HDM allergen (Der fI) than without dogs. Conclusion: The photophobic mites thrive in dark. warm and humid environments; Items such as pillows. mattresses, box springs, blankets. carpets. and upholstered furniture should be considered ideal environments for the mite. Therefore, an indoor environmental control program should be carried out to avoid the HDM allergen.

  • PDF