• 제목/요약/키워드: varying coefficients

검색결과 361건 처리시간 0.025초

Investigation of surface-piercing fixed structures with different shapes for Bragg reflection of water waves

  • Ding, Wei-Wei;Zou, Zao-Jian;Wu, Jing-Ping;Huang, Bai-Gang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권2호
    • /
    • pp.819-827
    • /
    • 2019
  • Bragg reflection of water waves by three kinds of surface-piercing fixed structures with rectangular, cosinoidal and triangular shapes is studied. Boundary element method is used to analyze the wave scattering by these structures based on the linear wave theory. Results of reflection and transmission coefficients are validated by comparing with those available in literature. These structures with proper configurations are proved to be effective in attenuating waves by using Bragg reflection, and the triangular structures are found to be the best choices among the structures with same width and same area. Systematic calculations are then carried out for the triangular structures by varying the number, the draft, the width, the gap and the combination of width and gap of the structures to analyze their influences on the characteristics of Bragg reflection. The results are of reference values for design of the structures to attenuate waves based on the Bragg reflection.

Fabrication of In-needle Microextraction Device Using Nichrome Wire Coated with Poly(ethylene glycol) and Poly(dimethylsiloxane) for Determination of Volatile Compounds in Lavender Oils

  • Lee, Eun Ji;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권1호
    • /
    • pp.211-217
    • /
    • 2014
  • A new needle-based device for headspace wire coated in-needle microextraction (HS-WC-INME) was fabricated using a nichrome wire coated with poly(ethylene glycol) (PEG) and poly(dimethylsiloxane) (PDMS) mixture. The proposed needle device was applied for the determination of volatile compounds in lavender and lavandin essential oils by gas chromatography. Fundamental parameters such as needle design, conditions of extraction and desorption were optimized along with the validation of the extraction and desorption efficiency. The optimal conditions were 30 min extraction at $50^{\circ}C$ and 2 min desorption at $240^{\circ}C$. The calibration curves showed good linearity with the suitable values of the coefficients of determination ($r^2$) greater than 0.99. The limits of detection for linalyl acetate, ${\beta}$-caryophyllene, linalool and (+)-limonene were 7.15, 9.04, 10.79 and 22.26 ng, respectively. Analytical recoveries were acceptable in the test samples, varying from 86.7% to 108.0%. The values of relative standard deviations for run to run showed range less than 0.9% while 3.9% through 7.2% for needle to needle. The proposed PEG-PDMS coating could be more suitable than PDMS coating to extract particular polar groups such as alcohols.

Cu-TiB2 복합재료의 마모거동에 따른 미세조직 관찰 (Observation on the Microstructures of Cu-TiB2 Composites with Wear Behavior)

  • 이태우;강계명
    • 한국재료학회지
    • /
    • 제16권8호
    • /
    • pp.511-515
    • /
    • 2006
  • The dispersion hardened $Cu-TiB_2$ composites are a promising candidate for applications as electrical contact materials. The $Cu-TiB_2$ composites for electrical contact materials can reduce material cost and resource consumption caused by wear, due to their good mechanical and electrical properties. In this study, we investigated the wear phenomenon for $Cu-TiB_2$ composites fabricated with hot extrusion, by varying particle sizes and volume fractions of $TiB_2$. The wear tests were performed under the dry sliding condition with a fixed total sliding distance of 40 m. The contact loads at a constant speed of 3.5 Hz were 20, 40, 60, and 80 N. The friction coefficients and wear losses were measured during wear tests. Worn surfaces and wear debris after wear tests were investigated using the scanning electron microscope and the optical microscope. The microstructures of interface between Cu matrix and $TiB_2$ particle before and after wear tests were studied by the transmission electron microscope.

사각채널에서 거친 벽면의 수가 압력강하와 열전달에 미치는 효과 (Effect of Number of Rough Walls on Pressure Drop and Heat Transfer in Square Channel)

  • 배성택;김명호;진용수;김성태;안수환
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.340-348
    • /
    • 2005
  • Repeated ribs are used on heat exchange surfaces to promote turbulence and enhance convective heat transfer. Applications include fuel rods of gas-cooled nuclear reactors, inside cavities of turbine blades, and internal surfaces pipes used in heat exchangers. Despite the great number of literature papers, only few experimental data concern detailed distributions of friction factors and heat transfer coefficients in square channels varying the number of rough walls. This issue is tackled by investigating effects of different number of ribbed walls on heat transfer and friction characteristics in square channel. The rough wall have a $45{\circ}C$ inclined square rib. Uniform heat flux is maintained on whole inner heat transfer channel area. The heat transfer coefficient and friction factor values increase with increasing the number of rough walls.

유공방파제의 반사특성에 관한 수리실험 (Hydraulic Experiments for the Reflection Characteristics of Perforated Breakwaters)

  • 박우선;전인식;이달수
    • 한국해안해양공학회지
    • /
    • 제5권3호
    • /
    • pp.198-203
    • /
    • 1993
  • 유공방파제의 반사특성을 규명하기 위하여 파고 및 주기가 다른 여러 규칙파를 대상으로 유수실의 폭과 유공벽의 형태를 변화시키며 수리실험을 수행하였다. 실험결과, 유공방파제의 반사특성은 유수실 폭과 유수실내 파장의 비(B/L$_{c}$)에 민감하게 반응하며, B/L$_{c}$가 0.2인 부근에서 최소의 반사율을 보임을 알 수 있었다. 이러한 현상은 주로 유수실내에서의 공진현상에 기인한 것으로 판단된다. 유공벽형태(종슬리트, 횡슬리트 또는 원형 구멍)의 변화는 반사율면에 있어서 약간의 변화를 초래할 수는 있어도, 전반적인 반사특성 변화에는 영향을 주지 못함을 확인하였다.하였다.

  • PDF

Comparison of simulated platform dynamics in steady/dynamic winds and irregular waves for OC4 semi-submersible 5MW wind-turbine against DeepCwind model-test results

  • Kim, H.C.;Kim, M.H.
    • Ocean Systems Engineering
    • /
    • 제6권1호
    • /
    • pp.1-21
    • /
    • 2016
  • The global performance of the 5 MW OC4 semisubmersible floating wind turbine in random waves with or without steady/dynamic winds is numerically simulated by using the turbine-floater-mooring fully coupled dynamic analysis program FAST-CHARM3D in time domain. The numerical simulations are based on the complete second-order diffraction/radiation potential formulations along with nonlinear viscous-drag force estimations at the body's instantaneous position. The sensitivity of hull motions and mooring dynamics with varying wave-kinematics extrapolation methods above MWL(mean-water level) and column drag coefficients is investigated. The effects of steady and dynamic winds are also illustrated. When dynamic wind is added to the irregular waves, it additionally introduces low-frequency wind loading and aerodynamic damping. The numerically simulated results for the 5 MW OC4 semisubmersible floating wind turbine by FAST-CHARM3D are also extensively compared with the DeepCWind model-test results by Technip/NREL/UMaine. Those numerical-simulation results have good correlation with experimental results for all the cases considered.

Modeling the Properties of the PECVD Silicon Dioxide Films Using Polynomial Neural Networks

  • Han, Seung-Soo;Song, Kyung-Bin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.195-200
    • /
    • 1998
  • Since the neural network was introduced, significant progress has been made on data handling and learning algorithms. Currently, the most popular learning algorithm in neural network training is feed forward error back-propagation (FFEBP) algorithm. Aside from the success of the FFEBP algorithm, polynomial neural networks (PNN) learning has been proposed as a new learning method. The PNN learning is a self-organizing process designed to determine an appropriate set of Ivakhnenko polynomials that allow the activation of many neurons to achieve a desired state of activation that mimics a given set of sampled patterns. These neurons are interconnected in such a way that the knowledge is stored in Ivakhnenko coefficients. In this paper, the PNN model has been developed using the plasma enhanced chemical vapor deposition (PECVD) experimental data. To characterize the PECVD process using PNN, SiO$_2$films deposited under varying conditions were analyzed using fractional factorial experimental design with three center points. Parameters varied in these experiments included substrate temperature, pressure, RF power, silane flow rate and nitrous oxide flow rate. Approximately five microns of SiO$_2$were deposited on (100) silicon wafers in a Plasma-Therm 700 series PECVD system at 13.56 MHz.

  • PDF

비정상 시변신호의 AR모델 파라메터 인식을 위한 최적의 웨이브렛 선택 (Optimal Wavelet Selection for AR Model Parameter Identification of Nonstationary Time-Varying Signal)

  • 신동환;김성환
    • 한국음향학회지
    • /
    • 제15권4호
    • /
    • pp.50-57
    • /
    • 1996
  • 본 논문에서는 최적의 웨이브렛 선택방법과 이 선택된 웨이브렛으로 F-검정을 이용하여 AR파라메터를 전개시키는 방법을 제안하였으며 웨이브렛 선택 방법으로서 평가함수를 도입하였다. 이 평가함수를 이용하여 웨이브렛들(D4-D20)을 합성신호에 대해서 시험하였다. 이때 선택된 웨이브렛을 이용하여 합성신호와 실제 음성신호에 대해서 AR파라메터들을 웨이브렛 전개 했을때의 웨이브렛 계수를 구하였다. 제안된 방법을 평가하기 위해서 칼만필터 알고리즘과 비교하였다. 그 결과 제안된 알고리즘이 칼만필터보다 약5-10dB정도 더 우수한 성능을 나타내었다.

  • PDF

Design optimization of vibration isolation system through minimization of vibration power flow

  • Xie, Shilin;Or, Siu Wing;Chan, Helen Lai Wa;Choy, Ping Kong;Liu, Peter Chou Kee
    • Structural Engineering and Mechanics
    • /
    • 제28권6호
    • /
    • pp.677-694
    • /
    • 2008
  • A vibration power minimization model is developed, based on the mobility matrix method, for a vibration isolation system consisting of a vibrating source placed on an elastic support structure through multiple resilient mounts. This model is applied to investigate the design optimization of an X-Y motion stage-based vibration isolation system used in semiconductor wire-bonding equipment. By varying the stiffness coefficients of the resilient mounts while constraining the dynamic displacement amplitudes of the X-Y motion stage, the total power flow from the X-Y motion stage (the vibrating source) to the equipment table (the elastic support structure) is minimized at each frequency interval in the concerned frequency range for different stiffnesses of the equipment table. The results show that when the equipment table is relatively flexible, the optimal design based on the proposed vibration power inimization model gives significantly little power flow than that obtained using a conventional vibration force minimization model at some critical frequencies. When the equipment table is rigid enough, both models provide almost the same predictions on the total power flow.

Performance Comparison of Liquid-Cooling with Air-Cooling Heat Exchangers Designed for Telecommunication Equipment

  • Jeon, Jong-Ug;Choi, Jong-Min;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권2호
    • /
    • pp.64-69
    • /
    • 2008
  • Electronic and telecommunication industries are constantly striving towards miniaturization of electronic devices. Miniaturization of chips creates extra space on PCBs that can be populated with additional components, which decreases the heat transfer surface area and generates very high heat flux. Even though an air-cooling technology for telecommunication equipment has been developed in accordance with rapid growth in electrical industry, it is confronted with the limitation of cooling capacity due to the rapid increase of heat density. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, air-cooling heat exchangers were tested to provide performance data for the comparison with the liquid-cooling heat exchangers. The liquid-cooling heat exchangers had twelve rectangular channels with different flow paths of 1, 2, and 12. Silicon rubber heaters were used to control the heat load to the heat exchangers. Heat input ranged from 293 to 800W, and inlet temperatures of working fluid varied from 15 to $27^{\circ}C$. The heat transfer coefficients were strongly affected by flow conditions. All liquid-cooling heat exchangers showed higher cooling performance than the air-cooling heat exchanger. The heat exchanger with 2-paths could provide more controllability on the maximum temperature than the others.