• 제목/요약/키워드: various emission rate

검색결과 332건 처리시간 0.021초

구강 악안면 영역의 암종 진단에 있어서 $[^{18}F]$-Fluorodeoxyglucose를 이용한 양전자방출 단층촬영의 임상적 연구 (CLINICAL STUDY OF POSITRON EMISSION TOMOGRAPHY WITH $[^{18}F]$-FLUORODEOXYGLUCOSE IN MAXILLOFACIAL TUMOR DIAGNOSIS)

  • 김재환;김경욱;김용각
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권5호
    • /
    • pp.462-469
    • /
    • 2000
  • Positron Emission Tomography(PET) is a new diagnostic method that can create functional images of the distribution of positron emitting radionuclides, which when administered intravenously in the body, makes possible anatomical and functional analysis by quantity of biochemical and physiological process. After genetic and biochemical changes in initial stage, malignant tumor undergoes functional changes before undergoing anatomical changes. So, early diagnosis of malignant tumors by functional analysis with PET can be achieved, replacing traditional anatomical analysis, such as computed tomography(CT) and magnetic resonance image(MRI), etc. Similarly, PET can identify malignant tumor without confusion with scar and fibrosis in follow up check. In the Korea Cancer Center Hospital(KCCH) from October 1997 to September 1999, clinical study was performed in 79 cases that underwent 89 times PET evaluation with [18F]-Fluorodeoxyglucose for diagnosis of oral and maxillofacial tumors, and the data was analysed by Bayesian $2{\times}2$ Classification Table. The results were as follows : Evaluation for initial diagnosis with FDG-PET (P<0.005) 1. Agreement rate or accuracy rate is 88.9%. 2. Sensitivity is 95.2%, and specificity 66.7%. 3. Positive predictive rate is 90.9%, and negative predictive rate 80.0%. 4. In consideration of tumor stage, diagnostic rate in less than stage II was 90% and in greater than stage III 100%. 5. In consideration of tumor size, diagnostic rate in less than T2 was 92.3% and in greater than T3 100%. After primary treatment, evaluation for follow up check with FDG-PET (P < 0.001) 1. Agreement rate or accuracy rate is 85.4%. 2. Sensitivity is 87.5%, and specificity 82.4%. 3. Positive predictive rate is 87.5%, and negative predictive rate 82.4%. 4. In 24 recurred cases, 6 had distant metastasis, and 5 of them were diagnosed with FDG-PET, resulting in diagnostic rate of FDG-PET of 83.3%. From the above results, Positron Emission Tomography with [18F]- Fluorodeoxyglucose appears to be more sensitive and accurate for detecting the presence of oral and maxillofacial tumors, and has various clinical applications such as early diagnosis of tumor in initial and follow up check and detection of distant metastasis.

  • PDF

Gas-Jet-assisted Glow Discharge에서 전류, 가스 흐름 속도, 압력에 따른 영향 연구 (Current, flow rate and pressure effects in a Gas-Jet-assisted Glow Discharge source)

  • 이계호;김동수;김은희;강성식;박민춘;송혜란;김하석;김효진
    • 분석과학
    • /
    • 제7권4호
    • /
    • pp.483-492
    • /
    • 1994
  • Glow Discharge를 이용한 고체 시료의 극미량 원소분석은 흡광, 방출, 형광 그리고 질량 분석 방법들이 특히 금속 시료들의 분석을 위해 많이 연구되어지고 있다. 본 연구에서는 자체 제작한 Gas-Jet-assisted Glow Discharge(GJGD)를 이용하여 각 실험변수에 따른 영향을 비교하여 보았다. 제작한 글로우 방전의 특성화 실험에 사용한 실험 변수로는 전류, 방전 가스의 흐름 속도, 압력 등이었고 시료는 황동을 사용하였다. 시료의 주원소인 구리(Cu)와 아연(Zn)의 방출선세기와 방전가스인 아르곤(Ar)의 상대적인 세기를 비교하여 보았는데, 대체적으로 전류의 증가는 튕겨나옴(Sputtering) 현상을 촉진시켜 방출선의 세기가 증가하였고 가스 흐름 속도는 플라즈마 속으로의 수송과 확산에 관여하여 증가될수록 방출선의 세기를 감소시켰다. 글로우 방전 내의 압력의 증가는 튕겨나옴 현상을 감소시킴과 더불어 시료 표면으로의 재부착을 증가시켜 방출선의 세기가 급격히 감소함을 보여 주었다.

  • PDF

발전용 밸브누설 음향 진단 및 감시시스템 (Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves)

  • 이상국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Dynamic Characteristics of a Urea SCR System for NOx Reduction in Diesel Engine

  • Nam, Jeong-Gil;Choi, Jae-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.235-242
    • /
    • 2007
  • This paper discusses dynamic characteristics of a urea-SCR (Selective Catalytic Reduction) system. The urea flow rate to improve NOx conversion efficiency is generally determined by parameters such as catalyst temperature and space velocity. The urea-SCR system was tested in the various engine operating conditions governing the raw NOx emission levels, space velocity. and SCR catalyst temperature. These experiments include cold-transients to determine catalyst light-off temperature and urea flow rate transients. Likewise. ammonia storage dynamics was also investigated. The cold-transient results indicate the light-off temperature of the catalysts used in these experiments was $200-220^{\circ}C$. The ammonia storage and urea flow rate transients all indicate very slow dynamics (on the order of seconds) which presents control challenges for mobile applications. The results presented in this paper should provide an excellent starting point in developing a functional in-vehicle urea-SCR system.

디젤 인젝터의 분사율 측정 기술과 분공수 변화가 분사특성에 미치는 영향에 관한 연구 (A Study on the Measurement Technique for Injection Rate and the Effects of the Nozzle Hole Number on Injection Characteristics)

  • 이기형;정재우;이창식
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.1-7
    • /
    • 2002
  • Recently, many researches for the improvement of DI diesel engines have been performed to reduce the fuel consumption and exhaust emissions. Among the various factors effect on combustion and emission in Dl diesel engines, one of the most important factors is the characteristics of the fuel spray. Accordingly, the investigation on the characteristics of spray is needed to analyze the diesel combustion exactly, In this study, the measurement technique fur injection rate using the Zeuch method was developed. In addition, the effects of nozzle hole number on the spray and flame were investigated by visualization experiment.

단기통 엔진에서 대유량 EGR을 통한 저온 연소 특성 (Characteristics of Low Temperature Combustion in Single Cylinder Engine by High EGR Rate)

  • 조상현;오광철;이춘범
    • 한국자동차공학회논문집
    • /
    • 제17권4호
    • /
    • pp.79-85
    • /
    • 2009
  • Low temperature combustion regime for the simultaneous reduction of nitrogen oxides ($NO_x$) and paticulate matter (PM) is demonstrated in single cylinder engine at various operating parameters, such as EGR rate, injection timing, EGR temperature, amount of fuel and swirl rate. Low temperature combustion is accomplished by high exhaust gas recirculation (EGR) rate in this study. Generally, the emission of $NO_x$ almost completely disappears and PM significantly increases in the first decreasing regime of oxygen concentration but after peaking about 10~12% oxygen concentration, PM then decreases regardless of fuel injection quantity. Low temperature combustion regime was extended by low EGR temperature, high injection pressure and low amount of fuel.

Rate Control for UWB Mobile Radios

  • Reali, Gianluca
    • Journal of Communications and Networks
    • /
    • 제6권2호
    • /
    • pp.173-181
    • /
    • 2004
  • This paper shows a technique for regulating the rate emitted by UWB mobile terminals. This technique is designed to adapt the emission rate to the effects of channel capacity variations. We assume that individual flows are shaped at edge routers by means of dual leaky buckets. The proposal is based on the evaluation of certain parameters, which reflect the channel status, sent to the application layer. This information is generated by the scheduler designed to guarantee appropriate channel sharing for the various traffic components. We describe some results which highlight how performance depends on the specific operating conditions, as well as on the traffic descriptors of the flows, their reciprocal difference, and performance requirements.

이륜자동차의 대기오염물질 배출계수 산정을 위한 연구 (Estimation of Air Pollutant Emission Factors for Motorcycle)

  • 임재현;김현민;이상문;강희준;임윤성;서충열;김종춘
    • 한국대기환경학회지
    • /
    • 제26권1호
    • /
    • pp.69-76
    • /
    • 2010
  • While increased use of motor cycles in the recent years for various demands could worsen air quality, only few studies have been conducted on estimation of emission factors and characterization of emissions from motorcycle. In this study, emissions from selected six models of motorcycle based on largest market share and production rate were investigated. To investigate gaseous and carbonaceous air pollutants, such as carbon monoxide (CO), total hydrocarbon (THC), nitrogen oxide ($NO_x$), elemental carbon (EC) and organic carbon (OC), total 124 motorcycles between 2003 and 2007 model year were tested with regulatory driving conditions, such as CVS-40 and CVS-47 mode. These motorcycles were further sub-categorized based on their displacement (< 50 cc, 50~150 cc, and $\geq$ 150 cc), type of stroke (2- and 4 strokes) and model year (2003~2005 and 2006~2007). Tested motorcycles with recent model year (2006~2007) exhibited less emissions of regulatory gaseous and carbonaceous air pollutants compared to old model year (2003~2005). Chemical analysis showed that CO present in highest concentration followed by THC and $NO_x$ for all tested motorcycles. Interestingly, two strokes motorcycle produced higher THC emission but less CO and $NO_x$ than those of four strokes. For all types of displacement and stroke, emission factors (gram per kilometer) of THC and CO except $NO_x$ with recent model year (2006~2007) showed decreased trend compared to old model year (2003~2005). In addition to this, due to mixed combustion between gasoline fuel and lubricant, two strokes motorcycle showed OC > EC emission trend.

반도체 제조용 CVD 및 Etcher 장비의 탄소배출량과 에너지 소비량 모니터링 (Monitoring of the Carbon Emission and Energy Consumption of CVD and Etcher for Semiconductor Manufacturing)

  • 고동국;배성우;김광선;임익태
    • 반도체디스플레이기술학회지
    • /
    • 제12권3호
    • /
    • pp.19-22
    • /
    • 2013
  • The purpose of this study is to develop a system that can monitor the amounts of energy consumption during CVD and etching process for semiconductor manufacturing. Specifically, this system is designed to measure the $CO_2$ emission amounts quantitatively by measuring the flow rate of gas used and amount of power consumed during the processes. The processes of CVD equipment can be classified generally into processing step and cleaning step and all the two steps were monitored. In CVD and etcher equipments, various gases including Ar and $O_2$ are used, but Ar, $O_2$ and He were monitored with the use of the LCI data of Korea Environmental Industry & Technology Institute and carbon emission coefficients of EcoInvent. As a result, it was found that the carbon emission amounts of CVD equipment for Ar, $O_2$ and He were $0.030kgCO_2/min$, $4.580{\times}10^{-3}kgCO_2/min$ and $6.817{\times}10^{-4}kgCO_2/min$, respectively and those of etcher equipment for Ar and $O_2$ are $5.111{\times}10^{-3}kgCO_2/min$ and $7.172kgCO_2/min$, respectively.

분자수준 시뮬레이션을 이용한 응력확대계수 및 전위이동에 관한 연구 (A Study on Stress Intensity Factors and Dislocation Emission via Molecular Dynamics)

  • 최덕기;김지운
    • 대한기계학회논문집A
    • /
    • 제24권4호
    • /
    • pp.830-838
    • /
    • 2000
  • The paper addresses an application of molecular dynamics technique for fracture mechanics. Molecular dynamics simulation is an atomistic approach, while typical numerical methods such as finite element methods are macroscopic. Using the potential functions, which express the energy of a molecular system, a virtual specimen with molecules is set up and the trajectory of every molecule can be calculated by Newton's equation of motion. Several three-dimensional models with various types of cracks are considered. The stress intensity factors, the sizes of plastic zone as well as the dislocation emission are sought to be compared with the analytical solutions, which result in good agreement.