• Title/Summary/Keyword: variation of rays

Search Result 70, Processing Time 0.031 seconds

Ontogenetic Color Variation of Abudefduf notatus (Pomacentridae: Perciformes) Revealed by 16S rRNA Sequences Analysis (미토콘드리아 16S rRNA 염기서열 분석에 의해 밝혀진 동갈자돔 치어의 성장에 따른 체색변이)

  • Song, Young Sun;Kim, Jin-Koo
    • Korean Journal of Ichthyology
    • /
    • v.25 no.2
    • /
    • pp.53-58
    • /
    • 2013
  • Seven individuals (16.1~29.1 mm in length) which were estimated with fishes of genus Abudefduf were collected in Seogwipo, Jeju Island in the summer of 2011 and 2012. Among them, five individuals (20.8~29.1 mm SL) are similar to Abudefduf notatus, based on morphological characters such as yellow transverse band on the body, one small black spot on the base of the pectoral fin, and yellow caudal fin. On the other hand, two individuals (16.1 mm, 17.0 mm SL) differ from them in several light transverse bands and transparent rays of all fins except for pelvic fin, and anterior transparent head with only one (16.1 mm). According to the results of molecular analyses of 578 base pairs of mtDNA 16S rRNA sequences, these individuals correspond to A. notatus adult, with a high bootstrap value of 95% (genetic distance, d=0.002). Therefore, this study shows that the individuals more than 20.8 mm similar to adult body color but the 16.1 mm individual differs to that of adult. We confirm that this species changes to body color during their early life stages. This result regards as a survival strategy to protect themselves against their predator during their early life stages.

The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom (근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Cho, Sam-Ju;Lee, Suk;Shin, Dong-Oh;Kwon, Soo-Il;Kim, Hun-Jung;Kim, Woo-Chul;K. Loh John-J.
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2005
  • Purpose: In this work we designed and made MPBP(Multi Purpose Brachytherapy Phantom). The MPBP enables one to reproduce the same patient set-up in MPBP as the treatment of the patient and we tried to get an exact analysis of rectal doses in the phantom without need of in-vivo dosimetry. Materials and Methods: Dose measurements were tried at a point of rectum 1, the reference point of rectum, with a diode detector for 4 patients treated with tandem and ovoid for a brachytherapy of a cervix cancer. Total 20 times of rectal dose measurements were made with 5 times a patient. The set-up variation of the diode detector was analyzed. The same patient set-ups were reproduced in self-made MPBP and then rectal doses were measured with TLD. Results: The measurement results of the diode detector showed that the set-up variation of the diode detector was the maximum $11.25{\pm}0.95mm$ in the y-direction for Patient 1 and the maximum $9.90{\pm}4.50mm,\;20.85{\pm}4.50mm,\;and\;19.15{\pm}3.33mm$ in the z-direction for Patient 2, 3, and 4, respectively. Un analyzing the degree of variation in 3 directions the more variation was showed in the z-direction than x- and y-direction except Patient 1. The results of TLD measurements in MPBP showed the relative maximum error of 8.6% and 7.7% at a point of rectum 1 for Patient 1 and 4, respectively and 1.7% and 1.2% for Patient 2 and 3, respectively. The doses measured at R1 and R2 were higher than those calculated except R point of Patient 2. this can be thought to related to the algorithm of dose calculation, whcih corrects for air and water but is guessed not to consider the correction for the scattered rays, but by considering the self-error (${\pm}5%$) TLD has the relative error of values measured and calculated was analyzed to be in a good agreement within 15%. Conclusion: The reproducibility of dose measurements under the same condition as the treatment could be achieved owing to the self-made MPMP and the dose at the point of interest could be analyzed accurately. If a treatment is peformed after achieving dose optimization using the data obtained in the phantom, dose will be able to be minimized to important organs.

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF

Morphological Variation and Karyotype of the Korean Species of Sticklebacks, (Pisces, Gasterosteridae) in Korea (한국산 큰가시고기과 어류의 형태변이와 핵형)

  • Kim, Ik-Soo;Yoon, Chang-Ho;Lee, Ji-Hyun
    • Animal Systematics, Evolution and Diversity
    • /
    • v.5 no.2
    • /
    • pp.107-119
    • /
    • 1989
  • Three species of Korean sticklebacks family Gasterosteidae were reviewed based on the specimens of several populations for the study of their morphological variations and taxonomical positions. All specimens of Gasterosteus aculeatus observed have a complte row of lateral plates ranging from thirty-two to thirty-five in number. The low-plate morph regarded as landlocked type is virtually absent. And no difference was recognized among six populations of G. aculeatus in the meristic chracters, i.e. number of vertebrae, gill rakers and finrays. The Pungitius sinensis and P.kaibarae ssp. shown local variations have scutes ranging from 31 to 35, but not clinal in the morphometric characters. But P.sinensis was statistically different from P.kaibarae ssp. in some characters such as the number of dorsal spine rays and vertebrae, and body depth, although their ranges overlapped. No significant taxonomic difference was detected between white from and black from in dorsal spinous membrane of P.kailbarae ssp. Although these three species of Korean sticklebacks have the same diploid chromosome number (2N=42), G. aculeatus is obviously different from the two species of genus Pungitius in their karyotype ; G. aculeatus consists of six metacentrics, six submetacentrics, and thiry subtelo-acrocentrics, and both P.sinensis and P.kaibarae ssp. have four metacentrics, six submetacentrics, and thirty-four subtelo-acrocentrics.

  • PDF

Analysis of the Physical Properties of Ground before and after Low Flowing Grouting (저유동성 그라우팅 시공전후 지반의 물성변화 분석)

  • Seo, Seok-Hyun;Lee, Jung-Sang;Kang, Won-Dong;Jung, Euiyoup
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.115-127
    • /
    • 2019
  • The low-flow grouting injection technique, the target construction method for this study, is a method of pouring mortar into the ground by non-emission replacement principle, which can be expected to increase the density of the ground, and, in some cases, be used as a base file using the strength of the high injection solids, along with low noise, low pollution, and high durability. To verify that the dynamic characteristics of the ground are improved by the low-flow injection technique, the test work was conducted on the site and physical tests were performed, and the quality of the improvement formed in the ground was verified through the indoor test on the core and core recovery rate was analyzed. The density logs test layer calculated the volume density of the ground layer by using the Compton scattering of gamma-rays, and the sonic logs was tested on the ground around the drill hole using a detector consisting of sonar and receiver devices inside the drill hole. As a result of the measurement of the change in physical properties (density and sonic logs) before and after grouting, both properties were basically increased after infusion of grout agent. However, the variation in density increase was greater than the increase in speed after grouting, and the ground density measurement method was thought to be effective in measuring the fill effect of the filler. Strength and core recovery rates were measured from specimens taken after the age of 28 days, and the results of the test results of the diffusion and strength test of the improved products were verified to satisfy the design criteria, thereby satisfying the seismic performance reinforcement.

Changes in lip and periornl soft tissue after bracket removal (브라켓 제거에 따른 입술과 주위 연조직의 변화)

  • Lee, Jeong-Sub;Choy, Kwang-Chul;Park, Young-Chel;Kim, Kyung-Ho
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.125-136
    • /
    • 2007
  • Objective: Soft tissue changes due to orthodontic treatment has large individual variation. Therefore continuous evaluation during treatment is required. Patients with fixed orthodontic appliances often wonder if their lip positions will change after the removal of brackets, but only a few studies exist on this topic. The objective of this study was to evaluate the changes of the lips and perioral soft tissue after bracket removal. Methods: The sample used in this study was 19 males and 33 females. Cephalometric X-rays were taken at 3 stages - T1 (before debonding), T2 (just after debonding), T3 (1.5 months after debonding). Results: The lower lip was retruded immediately after debonding (T2-T1), and 1.5 months after debonding (T3-T2). The mean amounts of retrusion from the vertical reference plane (sG perpendicular line) were about 0.38 mm for the upper lip and 0.88 mm for the lower lip. Immediately after debonding, lip retrusion of females was greater than that of males. During the post-debonding period, lower lip of males was retruded more than that of females. Conclusion: Lips are retruded after bracket removal, and there is no gender difference 1.5 months after debonding.

Species and Hybrid Identification of Genus Coreoleuciscus Species in Hwnag-ji Stream, Nakdong River Basin in Korea (낙동강 상류 황지천에 서식하는 쉬리속(genus Coreoleuciscus) 어류 집단의 종 동정 및 잡종 판별)

  • Song, Ha-Yoon;Kim, Jae-Hun;Seo, In-Young;Bang, In-Chul
    • Korean Journal of Ichthyology
    • /
    • v.29 no.1
    • /
    • pp.1-12
    • /
    • 2017
  • A natural hybrid of interspecific between the Coreoleuciscus splendidus and C. aeruginos (Cypriniformes: Cyprinidae) was captured in the Hwang-ji Stream, a tributary of the Nakdong River basin in Korea. An interspecific hybrid between C. splendidus and C. aeruginos was genetically identified based on morphological characteristics and the sequence analysis of nuclear recombination activating gene 1 (RAG1) gene (1,334 bp) and mitochondrial cytochrome c oxidase subunit 1 (CO1) gene (1,551 bp). As a result of morphological variations, the natural hybrid appeared to have an intermediate character between two parental species (C. splendidus and C. aeruginos) in three variations of black array (s) on dorsal, caudal and anal fin rays. Phylogenetic analysis inferred from RAG1 and CO1 sequence data revealed that Coreoleuciscus populations from Hwang-ji stream consist of two pure Coreoleuciscus species and a hybrid individual group. The individuals were clearly identified the cross and reciprocal hybrid by CO1 gene analysis. In RAG1 gene, 13 nucleotide variation loci were detected and the hybrid individuals displayed the double peaks of sequence chromatograms at the 9 diagnostic positions. In this study, molecular data and morphological variations were clearly demonstrated that hybridization did occur between C. splendidus and C. aeruginos. However, F2 hybrid generation and reproductive capacity of F1 hybrid individuals were not demonstrated.

Changes of Optically Stimulated Luminescence Dosimeter Sensitivity with High Dose (고선량에 대한 광자극발광선량계의 방사선 민감도 변화 연구)

  • Han, Su Chul;Kim, Kum Bae;Choi, Sang Hyoun;Park, Seungwoo;Jung, Haijo;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.98-104
    • /
    • 2016
  • We investigated the effect of high dose on the sensitivity of optically stimulated luminance dosimeters (OSLDs) on Co-60 gamma rays and used a commercial OLSD (Landauer, Inc., Glenwood, IL). New OSLDs were chosen arbitrarily and were irradiated with 1 Gy repeatedly. We confirmed the change in the radiation sensitivity after repeated irradiation. The OSLD sensitivity increased up to 3% after irradiating for seven times and decreased continuously after the eighth time. It dropped by approximately 0.35 Gy per irradiation. Finally, after irradiating for 30 times, the OSLD sensitivity decreased by approximately 7%. When the OSLDs were irradiated 10 times with 1 Gy after their irradiation using a high dose of 15 Gy and 30 Gy, their sensitivity decreased by 6% and 12%, respectively, compared to that before high-dose irradiation. The change in the OSLD sensitivity with a high dose could be modeled by an exponential equation. We confirmed the radiation sensitivity variation caused by a high dose, and the irradiation history of dosimeters was considered to reuse OSLDs irradiated with a high dose.

Analysis of 226Ra in the Groundwater Using the Gamma-ray Spectroscopy (감마선 분광법을 이용한 지하수 중의 226Ra 분석)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.39-47
    • /
    • 2003
  • The measurement of radium ($^{226}Ra$) in the groundwater was established using ${\gamma}$-ray spectroscopy without sample preparation. The background interference by air borne radon daughter nuclides was reduced by $N_2$ gas flow into the counting chamber. Leakage of radon gas produced in the radioactive equilibrium with radium and its daughter nuclides was prevented by use of the air-tighted aluminium container. We investigated the effect of air layer in the counting container. Radioactivity variation due to emanation of radon into the air layer was within the counting error range 5%. When the nitrogen gas was flowed around the detector, peak counts of ${\gamma}$-rays from the daughters of airborne radon was decreased and detection limit was decreased to 0.02 Bq/L. The detection limit of detector was lower than 0.74 Bq/L, the $^{226}Ra$ Maximum Contaminant Level (MCL) in the groundwater proposed by US Environmental Protection Agency (EPA). It was confirmed that $^{226}Ra$ radioactivity in the groundwater could be determined by the ${\gamma}$-ray spectroscopy.

Feasibility of Ocean Survey by using Ocean Acoustic Tomography in southwestern part of the East Sea (동해 남서해역에서 해양음향 토모그래피 운용에 의한 해양탐사 가능성)

  • Han, Sang-Kyu;Na, Jung-Yul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.75-82
    • /
    • 1994
  • The ray paths and travel times of sound wave in the ocean depend on the physical properties of the propagating media. Ocean Acoustic Tomography(OAT), which is inversely estimate the travel time variations between fixed sources and receivers the physical properties of the corresponding media can he understood. To apply ocean survey technology by using the OAT, the tomographic procedure requires forward problem that variation of the travel times be identified with the variability of the medium. Also, received signals must be satisfied the necessary conditions of ray path stability, identification and resolution in order for OAT to work. The canonical ocean has been determined based on the historical data and its travel time and ray path are used as reference values. The sound speed of canonical ocean in the East Sea is about 1523 m/s at the surface and 1458 m/s at the sound channel axis(400m). Sound speeds in the East Sea are perturbed by warm eddy whose horizontal extension is more than 100 km with deeper than 200 m in depth scale. In this study, an acoustic source and receiver are placed at the depth above the sound channel axis, 350 m, and are separated by 200 km range. Ray paths are identified by the ray theory methed in a range dependent medium whose sound speeds are functions of a range and depth. The eigenray information obtained from interpolation between the rays bracketing the receiver are used to simulate the received signal by convolution of source signal with the eigenray informations. The source signal is taken as a 400 Hz rectangular pulse signal, bandwidth is 16 Hz and pulse length is 64 ms. According to the analysis of the received signal and identified ray path by using numerical model of underwater sound propagation, simulated signals satisfy the necessary conditions of OAT, applied in the East Sea.

  • PDF