• 제목/요약/키워드: variation in 3-D

검색결과 1,922건 처리시간 0.035초

잠제의 배치형상에 따른 연안의 처오름 변화에 관하여 (On Variation Characteristics of Run-up Height over Beach due to Plane Arrangement of Submerged Breakwaters)

  • 허동수;이우동;이현우
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.457-460
    • /
    • 2006
  • This study is to investigate the variation characteristics of run-up height over sandy beach due to the plane distribution of submerged breakwaters. In this study, Three-Dimensional numerical model with Large Eddy Simulation, which is able to simulate directly WAve Structure Seabed interaction (hereafter, LES-WASS-3D) has been newly developed. A comparison between the numerical model and existing experimental results was made to verify accuracy of newly proposed LES-WASS-3D model, and showed fairly nice agreement. In addition, based on the LES-WASS-3D model, the variation characteristics of run-up height over sandy beach are discussed with relation to the offshore distance and opening width of submerged breakwaters.

  • PDF

한국 근해 수온의 주기적 변화(I) 남해의 거문도해역 표면수온 년주변화 및 영년변화 (Periodic Variations of Water Temperature in the Seas Around Korea(I) Annual and Secular Variations of Surface Water Temperature, Kumun-Do Region, Southern Sea of Korea)

  • 한상복
    • 한국해양학회지
    • /
    • 제5권1호
    • /
    • pp.6-13
    • /
    • 1970
  • Ten days and monthly mean temperatures were analysed daily data observed during July, 1916 to March, 1970 statistically. Periodic characters were calculated by Δn, new method of approximate solution of Schuster Method. According to ten days mean temperatures, annual variation function is F($\theta_d$)=16.29-5.27 cos $\theta_d$+0.75 cos2 $\theta_d$-3.14 sin $\theta_d$+1.16 sin2 $\theta_d$-0.63 sin $\3{theta}_d$, where $\theta_d$=$-\frac{\pi}{18}$(d-3), d is the order of ten days period, 1 to 36. Annual mean water temperature is 16.3$^{\circ}C$, minimum in the last ten days of February 10.9$^{\circ}C$, maximum in the last ten days of August 24.5$^{\circ}C$. Periodic character of secular variation shows 11 year and its curve is F($\theta_y$)=16.29+0.53 cos $\theta_y$ -0.16cos $2{\theta}_y$+0.10 cos$3{\theta}_y$-0.10 sin $\theta_y$, where $\theta_y$=2$-\frac{2\pi}{11}$(y-1920), y is calendar year. And the relation between air temperature x and water temprature y is following. y=9.67 1.035$\^x$

  • PDF

흉복부 방사선 치료 시 압력 기반 복부압박장치 적용에 따른 치료 간 재현성 평가 (Reproducibility evaluation of the use of pressure conserving abdominal compressor in lung and liver volumetric modulated arc therapy)

  • 박가연;김주호;신현경;김민수
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.71-78
    • /
    • 2021
  • 목 적: 폐암과 간암 환자에 대해 압력 기반 복부압박장치를 적용하여 입체적 세기변조 회전 방사선치료(VMAT)를 시행하였을 때의 치료 간(interfraction) 위치 재현성과 호흡 재현성을 평가함으로써 그 유용성을 평가하고자 한다. 대상 및 방법: 압력 기반 복부압박장치를 사용해 입체적 세기변조 회전 방사선치료를 받은 6명의 폐암 환자와 3명의 간암 환자를 대상으로 하였다. 치료 간 위치 재현성 평가를 위해 모의치료 CT 영상과 매일 획득한 CBCT 영상 174건을 비교하여 이미지 정합의 이동 값을 비교, 분석하였다. 치료 간 호흡 재현성 평가를 위해 모의치료 4DCT 영상과 매주 획득한 4D CBCT 영상 54건을 비교하여 호흡량 오차를 구하였다. 결 과: 수평수직 세 방향의 3D 벡터값인 전체 위치변화(Overall position variation, Overall VP)값은 폐와 간에서 각각 평균 1.1 ± 1.4 mm, 4.5 ± 2.8 mm로 나타났다. 호흡 변화(respiratory variation, Vr)값은 폐에서 평균 0.7 mm ± 3.4 mm (p=0.195), 간에서 평균 3.6 mm ± 2.6 mm (p<0.05)로 나타났다. 결 론: 흉복부 방사선 치료 시 압력 기반 복부압박장치의 적용은 복부 압박 재현을 통해 치료 간 종양의 호흡 변이뿐만 아니라 위치 변이를 안정적으로 조절하는 데에 유용한 것으로 사료된다. 보다 안정적인 재현성을 위해 치료 계획 시 적절한 PTV 여유가 고려되어야 하고, 매 치료 전 영상 유도에 따른 표적의 위치와 호흡 검증이 필요하다.

PERIOD VARIATION OF EROS ECLIPSING BINARY SYSTEMS IN THE LARGE MAGELLAN CLOUD

  • RITTIPRUK, P.;HONG, K.S.;KANG, Y.W.
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.211-214
    • /
    • 2015
  • We investigated the period variation for 79 eclipsing binary systems using 20 years (1990-2009) of EROS, Macho, and OGLE survey observations. We discovered 9 apsidal motions, 8 mass transfers, 5 period increasing and decreasing systems, 12 light-travel-time effects, 5 eccentric systems and 40 other systems showing no period variations. We select 3 representative eclipsing binary systems; EROS 1052 for apsidal motion, EROS 1056 for mass transfer, and EROS 1037 for the light-travel-time effect. We determine the period variation rate (dP/dt), orbital parameters of the 3rd body (e3, ${\omega}_3$, $f(m_3)$, $P_3$, $T_3$), apsidal motion parameters ($d{\omega}/dt$, U, Ps, Pa, e) and apsidal motion period by analyzing the light curves and O-C diagrams.

지역사회건강조사에서 EQ-5D index의 지역간 변이와 관련 요인: 사회심리적 요인의 중요성 (Regional Variation of EQ-5D Index and Related Factors in Community Health Survey: Major Role of Psychosocial Factors in Korea)

  • 김은수;남해성
    • 농촌의학ㆍ지역보건
    • /
    • 제45권4호
    • /
    • pp.183-193
    • /
    • 2020
  • 이 연구는 생태학적 연구로서 EQ-5D index로 측정되는 건강수준의 시군구 단위 변이를 파악하고 지역사회건강조사 지표에서 이러한 변이를 설명하는 요인을 탐색하고자 하였다. 2017년도 지역사회건강조사자료에서 산출되는 전국 229개 시군구의 EQ-5D index 변이는 EQ(격차비) 1.1배, CV(변이계수) 1.0으로 지역 간 변이는 연구에 포함된 독립변수들에 비해 상대적으로 작았다. EQ-5D index 값이 전국 하위 25%에 속하는 시군구 비중이 높은 광역시도는 전라북도(9개 시군, 64.3%)와 충청남도(7개 시군, 46.7%)이었다. 다중 선형회귀분석 결과 지역 간 변이의 주요요인으로 우울감 경험률, 스트레스 인지율, 자살 생각률, 관절염진단 경험률 등이 도출되었다. 지역 간 건강수준의 격차를 줄이기 위해서는 사회심리적 요인들을 포함한 상기 요인들의 개선에 우선순위를 두어야 할 것으로 사료된다.

A High Current Efficiency CMOS LDO Regulator with Low Power Consumption and Small Output Voltage Variation

  • Rikan, Behnam Samadpoor;Abbasizadeh, Hamed;Kang, Ji-Hun;Lee, Kang-Yoon
    • 전기전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.37-44
    • /
    • 2014
  • In this paper we present an LDO based on an error amplifier. The designed error amplifier has a gain of 89.93dB at low frequencies. This amplifier's Bandwidth is 50.8MHz and its phase margin is $59.2^{\circ}C$. Also we proposed a BGR. This BGR has a low output variation with temperature and its PSRR at 1 KHz is -71.5dB. For a temperature variation from $-40^{\circ}C$ to $125^{\circ}C$ we have just 9.4mV variation in 3.3V LDO output. Also it is stable for a wide range of output load currents [0-200mA] and a $1{\mu}F$ output capacitor and its line regulation and especially load regulation is very small comparing other papers. The PSRR of proposed LDO is -61.16dB at 1 KHz. Also we designed it for several output voltages by using a ladder of resistors, transmission gates and a decoder. Low power consumption is the other superiority of this LDO which is just 1.55mW in full load. The circuit was designed in $0.35{\mu}m$ CMOS process.

두충엽 함유 퀘르세틴배당체의 함량 표준화 및 계절적 변화 (Standardization and Seasonal Variation of Quercetin Glycoside in Eucommiae Folium)

  • 함인혜;이승재;김호현;강인호;진희억;황완균
    • 생약학회지
    • /
    • 제33권3호통권130호
    • /
    • pp.194-199
    • /
    • 2002
  • The radix and folium of Eucommia ulmoides(Eucommiaceae) has been used for backache, atrophy of the leg and knee, enuresis, hypertension. In order to evaluate to quality of folium, we have been isolated a main compound as a standard compound, which was elucidated $quercetin-3-O-{\beta}-D-xylopyranosyl(l{\rightarrow}2)-{\beta}-D-glucopyranoside$ through it's physicochemical data and IR, FAB-Mass, $^{13}C-NMR$ and $^{1}H-NMR$ analysis. It was analyzed by HPLC system using 17% $CH_3CN$ as a solvent system. The amount of $quercetin-3-O-{\beta}-D-xylopyranosyl(l{\rightarrow}2)-{\beta}-D-glucopyranoside$ from Eucommiae folium was in the range of $0.056{\pm}0.022$ mg(n=7) and also from the results of analysis through seasonal variation$(June{\sim}October)$ September and October have been evaluated to be very high in it's content.

초고주파 집적회로의 수율향상을 위한 새로운 바이어스 안정화 회로 (A Newly Proposed Bias Stability Circuit for MMIC율s Yield Improvement)

  • 권태운;신상문;최재하
    • 한국전자파학회논문지
    • /
    • 제13권9호
    • /
    • pp.882-888
    • /
    • 2002
  • 본 논문에서는 공정변화와 온도변화에 의한 MMIC의 성능저하를 보상할 수 있는 바이어스 안정화 회로를 제안하였다. 제안된 바이어스 안정화 회로는 기존의 정전류원을 사용하는 바이어스 회로와의 비교를 통하여 그 효과를 검증하였다. 두 구조를 동일한 조건으로 비교하기 위해 하나의 레이아웃에 두 구조를 채택한 증폭기를 동시에 설계 및 제작을 하였다. 공정오차는 세가지 경우 NOM, MIM, MAX로 구분하고 각각에 대해 고주파 특성을 측정하였다. 측정 결과로 정전류원을 가지는 바이어스회로를 채택한 증폭기 의 1.8 GHz에서의 이득변화는 6.4 dB, Ids 변화 7 mA이지만 제안된 바이어스회로를 채택한 증폭기는 이득변화는 2.1 dB, Ids 변화 3 mA로 우수한 특성을 보임을 확인하였다. 따라서, 제안된 바이어스 회로를 적용한 MMIC는 공정상의 변화와 온도 등에 의한 동작점의 변화를 보상하여 고주파특성의 감쇠를 보상할 수 있고 궁극적으로 회로의 수율을 개선할 수 있다. 제작된 회로의 전체크기는 1.2 mm $\times$ 1.4 mm이다.

파라볼릭 반사기 체적 축소용 프린트 리플렉트어레이 안테나 설계 (Printed Reflectarray Antenna Design for Parabolic Reflector Volume Reduction)

  • 문상만;김인규
    • 항공우주기술
    • /
    • 제12권2호
    • /
    • pp.140-146
    • /
    • 2013
  • 본 연구는 파라볼릭 반사기의 체적을 줄일 수 있는 프린트 리플렉터어레이 안테나 설계에 대한 연구이다. 이를 위해 시뮬레이션과 제작된 도파관 시뮬레이터 측정을 통해 리플렉트어레이 안테나 단일소자의 위상변위 특성을 확인하였다. 그 결과, 10GHz에서 시뮬레이션시 최대 $298^{\circ}$의 위상 변위를 나타내었으며, 제작 측정시 $309^{\circ}$의 평균 위상변위 특성이 나타남을 확인하였다. 또한, 프린트 리플렉트어레이 안테나 이득은 28.3dBi, 3dB 빔폭은 E-plane $5.1^{\circ}$, H-plane $5.2^{\circ}$, 부엽은 E-plane -11.4dB, H-plane -17.6dB를 나타내었다.

Thyrogen 투여 후 측정된 Thyroglobulin 농도변화 (The Variation of Serum Thyroglobulin Measured after Thyrogen Administration)

  • 김지나;안재석;원우재
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.80-83
    • /
    • 2018
  • Purpose Assessment of Serum Thyroglobulin (sTg) value in total thyroidectomy patients having an ablation dose of radioactive iodine indicates remaining cancer or metastasis. Especially, sTg in patients on withdrawal thyroxine or thyrogen administration for radioiodine ablation is an important indicator to determine the direction of further treatment and prognosis. Current guidelines suggest measurement of sTg is performed at 72 hours after the last injection of thyrogen. and assumes that sTg reaches maximum serum levels at that time. The purpose of this study is to evaluate the variation of sTg measured after thyrogen administration. Materials and Methods We compared with sTg performed at 24hours(D0) and 72hours(D2) after the last injection of thyrogen. We reviewed D0 and D2 from 276 patients were divided them into three groups according to ablation dose of radioactive iodine, 5mCi(A group), 30~80mCi(B group) and 100~200mCi(C group). We used T-test for comparison between D0 and D2. sTg was measured in serum using immunoradiometric assay (Tg-plus RIA; BRAHMS, Berlin, Germany). Results There is no critical variation between D0 and D2 in A group(n=100)(P=0.32), The case of increase(D2>D0) is 45, no change(D2=D0) is 23, decrease(D2D0 is 91, D2=D0 is 28, D2D0 is 19, D2=D0 is 2. The biggest increase is 143.6 ng/mL from 98.4 to 242. Conclusion There was a significant difference in the group over 30mCi. and the case of D2>D0 is 45%, 58.7%, 90.5% for each group. therefore, D2 increased as the dose of radioactive iodine increased. Furthermore, the most sTg values of D0 and D2 are variation under 2.0 ng/mL, so reproducibility as well as sensitivity of sTg will be important at values below 2ng/mL.